- All
- Favorite
- Popular
- Most rated
| Brand | TLS |
|---|---|
| Origin | Spain |
| Model | T-5333 |
| Application | Burst strength testing of paper and paperboard |
| Category | Physical property testing instrument / Tribological tester (burst-specific) |
| Import status | Imported |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | F47900 (2 L) / F48000 (5.8 L) |
| Temperature Range | 100–1200 °C |
| Chamber Volume | 2 L or 5.8 L |
| Heating Element Layout | Dual-side mounted |
| Max. Operating Temperature | 1200 °C |
| Rear Port Diameter | 9.5 mm |
| Control Options | A1 (single-setpoint), B1 (delayed ramp), C1 (8-segment single program), D1 (16-segment × 4 programs, RS232 interface) |
| Venting | Integrated exhaust port |
| Construction | Heat-treated ceramic chamber lining |
| Compliance | Designed for GLP-compliant thermal processing in analytical and materials laboratories |
| Brand | WEISS |
|---|---|
| Origin | Germany |
| Model | WK |
| Chamber Volume Options | 4–41 m³ |
| Temperature Range | +20 °C to +45 °C |
| Temperature Uniformity | ≤ ±1 °C |
| Humidity Range | 20–80 % RH |
| Humidity Stability (over time) | ≤ ±3 % RH |
| Insulation | CFC-free polyurethane (PU) |
| Control System | Microprocessor-based, compliant with GAMP 5 and FDA 21 CFR Part 11 |
| Humidification | Ultrasonic |
| Dehumidification | Refrigerant-based |
| Heating | Electric |
| Cooling | Air-cooled refrigeration |
| Safety Features | Dual independent temperature safety cut-offs, sample temperature monitoring, emergency door release |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | F6000-60 / F30400-60 |
| Temperature Range | 100–975 °C |
| Chamber Volume | 15 L or 45 L |
| Air Flow Control | 0–80 L/min (adjustable via front-mounted flowmeter) |
| Temperature Stability at 750 °C | ±3 °C |
| Heating Rate | 8 °C/min (≤500 °C), 6 °C/min (500–750 °C) |
| Compliance | ASTM D3174 |
| Gas Inlet Ports | 1 × 0.95 cm thermocouple port, 1 × 0.635 cm or 0.876 cm soft-hose barb for inert gas supply |
| Control Options | B1 (single-setpoint), C1 (8-segment single program), D1 (16-segment × 4 programs, RS232 interface) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | F1600 / F1700 / F1800 |
| Temperature Range | 150–1360 °C |
| Chamber Volume | 5.7–41.4 L |
| Construction | Heavy-duty refractory brick lining + reinforced steel cabinet |
| Heating Element Configuration | Four-wall embedded in refractory cement |
| Standard Floor Protection | Ceramic hearth plate |
| Power Supply | Requires external hardwiring |
| Controller | Sold separately |
| Safety Design | Top-hinged door with heat-shielded orientation (hot surface directed away from operator) |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | Sievers 900 |
| Detection Range | 0.03 ppb to 50 ppm |
| Accuracy | ±2% |
| Precision | <1% RSD |
| Oxidation Method | UV/Persulfate |
| Detection Method | Membrane Conductivity |
| Sample Pressure | up to 250 psi |
| Flow Rate | 30–300 mL/min |
| Sample Temperature | 1–95 °C |
| Analysis Time | 4 min (standard), 4 s (rapid module) |
| IP Rating | IP65 |
| Compliance | US EPA Method 5310C, US EPA 415.3, ASTM D7573 |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | Sievers 500RL |
| Detection Range | 0.03–2,500 ppb as C |
| Accuracy | ±5% |
| Precision | ≤0.03 ppb (for <3 ppb) or ≤1% RSD (for ≥3 ppb) |
| Conductivity Measurement Range | 0.01–35 µS/cm |
| Conductivity Accuracy | ±0.005 µS/cm (≤0.25 µS/cm) or ±2% (>0.25 µS/cm) |
| Conductivity Precision | <0.25% RSD |
| Max Acceptable Sample Conductivity | 25 µS/cm at 25°C (neutral pH) |
| Ozone Tolerance | 200 ppb |
| Operating Temperature Range | 1–95°C (steam-tolerant for short durations) |
| Key | Origin: Germany |
|---|---|
| Model | MD 1C |
| Max. Pumping Speed | 1.3 m³/h |
| Ultimate Vacuum (absolute) | 2 mbar |
| Ultimate Vacuum with Gas Ballast | 4 mbar |
| Dimensions (L×W×H) | 316 × 143 × 175 mm |
| Weight | 6.9 kg |
| Order No. | 696600 |
| Brand | WEISS |
|---|---|
| Origin | Germany |
| Model | WK-Series |
| Chamber Volume Options | 4 m³, 10 m³, 15 m³, 25 m³, 32 m³, 41 m³ |
| Temperature Range | +20 °C to +45 °C |
| Temperature Uniformity | ≤ ±1 °C |
| Humidity Range | 20 % r.H. to 80 % r.H. |
| Humidity Stability (over time) | ≤ ±3 % r.H. |
| Insulation | CFC-free polyurethane (PU) foam |
| Control System | Microprocessor-based, compliant with GAMP 5 and FDA 21 CFR Part 11 |
| Humidification | Ultrasonic |
| Dehumidification | Refrigerant-based |
| Safety Features | Dual independent temperature safety cut-offs, sample temperature monitoring, emergency door release mechanism |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | FD1500 |
| Temperature Range | 100–1200 °C |
| Chamber Volume | 2.2 L |
| Heating Elements | 4 independent embedded in refractory cement |
| Safety Features | Door-activated power cutoff, dual overtemperature protection (mechanical relay + thermocouple fault detection), adjustable audible alarm |
| Interface Options | B1 (single-setpoint digital controller with ramp delay) or C1 (8-segment programmable digital controller) |
| Rear Port | 0.95 cm diameter for external temperature monitoring |
| Construction | Refractory brick-lined chamber with firebrick door seal |
| Power Cord | Included |
| Compliance | Designed for GLP-compliant weight loss and ashing workflows per ASTM E1868, ISO 1171, and USP <281> |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | SER158 |
| Application Category | Fully Automated Protein and Fat Determination Instrument |
| Extraction Principle | Randall Continuous Extraction Technology |
| Compliance Standards | AOAC 920.39, ISO 1443, ISO 6496, EPA 3541, APHA 5520E, UNI EN ISO 1443 |
| Safety Certification | CE, IEC 61010-1 |
| Brand | LWLI |
|---|---|
| Origin | Fujian, China |
| Model | D-Series |
| Instrument Type | LC-AFS Hyphenated System |
| Sample Introduction | Peristaltic Pump |
| Waste Disposal | Peristaltic Pump Extraction |
| Hydride/Vapor Generation Mode | On-line UV Digestion + Chemical Reduction |
| Target Elements (Total) | Hg, As, Se, Sb, Bi, Pb, Cd, Ge, Sn, Te, Zn, Au |
| Target Species (Speciation) | As(III), As(V), MMA, DMA, monomethylmercury (MMHg), ethylmercury (EtHg), Se(IV), Se(VI), selenomethionine, antimony species, etc. (≥12 species) |
| RSD | <0.6% |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits (ng/L) | Hg ≤ 0.001 |
| PMT Wavelength Range | 160–320 nm |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | BD/BF |
| Temperature Range | +5 °C to 99.9 °C (above ambient) |
| Temperature Accuracy | ±0.1 °C |
| Control System | Microprocessor-based PID controller with LED display |
| Timer Function | 0–99:59 h |
| Safety Device | Class 3.1 temperature safety device (DIN 12880) |
| Communication Interface | RS422 for APT-COM software integration |
| Interior Door | Smooth tempered glass |
| Air Circulation | Forced convection (BF series) |
| Sterilization Capability | Dry-heat decontamination at 99 °C |
| Preconditioning Technology | APT-Line® preheating chamber |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model Series | MKF / MK / MKT |
| Internal Volume Options | 53 L, 115 L, 240 L, 400 L, 720 L |
| Temperature Range | MK/MKF: −40 °C to +180 °C |
| MKT | −70 °C to +180 °C |
| M-Series | +5 °C above ambient to +300 °C |
| Humidity Range (MKF only) | 10–98 % rH |
| Control System | MB1 4-channel touchscreen controller (25 programs × 100 segments) |
| Cooling Technology | DCT® Direct Cooling Technology |
| Preconditioning Chamber | APT-Line® |
| Air Circulation | Digitally adjustable high-power turbine |
| Compliance | DIN EN 60068-3-5, IEC 60068-3-6, ISO 16750-4, ASTM D4329, USP <1151> (environmental stress testing), GLP-compliant data logging via APT-COM software |
| Interface | RS422 for APT-COM v3.x integration |
| Insulation | High-efficiency vacuum-insulated door & polyurethane foam walls |
| Brand | TLS |
|---|---|
| Origin | Spain |
| Model | T-2911 |
| Type | Import |
| Distributor Type | Authorized General Distributor |
| Pricing | Available Upon Request |
| Brand | TLS |
|---|---|
| Origin | Spain |
| Model | Validator™ |
| Type | Compression Testing Machine for Physical Property Evaluation |
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | F60 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Temperature Control Range | 6°C to 400°C |
| Maximum Ramp Rate | 120°C/min |
| Cooling Time | <7.0 min (from 350°C to 50°C) |
| Carrier Gas Flow Control | Electronic Flow Display |
| Carrier Gas Pressure Control | Electronic Pressure Display |
| Injector Maximum Operating Temperature | 400°C |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | F70 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 6 °C to 400 °C |
| Maximum Ramp Rate | 120 °C/min |
| Cooling Rate | <7.0 min from 350 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–450 mL/min |
| Carrier Gas Pressure Range & Control | 0–100 psi |
| Electronic Pressure Control (EPC), pressure setting resolution | 0.01 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–100 psi |
| Injector Total Flow Setting Range | 0–450 mL/min |
| Brand | Parker |
|---|---|
| Origin | USA |
| Model Series | NitroFlow Lab, N2-04 / N2-14 / N2-22 / N2-35 / N2-45 / N2-80 / N2-135 |
| Flow Rate Range | 4–467 L/min |
| Nitrogen Purity | ≥99.5% (standard models), up to 99.999% (LCMS-SF series) |
| Technology | Hollow-Fiber Membrane Separation |
| Power Requirement | None (for air-fed split-system configurations) |
| Compliance | Phthalate-free, VOC-free, MS-compatible design |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM 850DL-12 |
| Instrument Type | Online Dissolution Tester |
| Vessel Positions | 8 or 12 |
| Temperature Range | Ambient to 45 °C ±0.1 °C |
| Rotation Speed Range | 25–250 rpm ±0.1 rpm |
| Pump Configuration | 12-channel syringe pump (12 × 10 mL) |
| Compliance | USP <711>, <724>, <723>, <725>, <731> |
| Integrated Modules | UDT-812A-12 dissolution apparatus, SCR-160L sample collector, SYP-6L 12-channel syringe pump, DSC-800D sampling controller |
| Brand | Parker |
|---|---|
| Origin | USA |
| Model | UHPN2-1100UK / HPN2-2000UK |
| Flow Rate | 1.1 L/min (UHPN2-1100UK), 2.0 L/min (HPN2-2000UK) |
| Purity | 99.9999% (UHPN2-1100UK), 99.99% (HPN2-2000UK) |
| Input | Compressed Air |
| Certification | CE, UKCA, ISO 9001-compliant design |
| Dimensions | Compact benchtop footprint (<450 mm W × 400 mm D × 500 mm H) |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | F30400 |
| Temperature Range | 100–1093 °C (up to 1200 °C short-term) |
| Chamber Volume | 45 L |
| Heating Element Layout | Top, Bottom, Left & Right Walls |
| Safety | 35 A Circuit Breaker + Interlocked Door Switch |
| Control Options | B1 (Single-Setpoint), C1 (8-Step Single Program), D1 (16-Step × 4 Programs, RS232) |
| Brand | ESCO |
|---|---|
| Origin | Singapore |
| Model | SPD-3A1 |
| External Dimensions (W×D×H) | 840 × 697 × 1110 mm |
| Airflow Capacity | 234 m³/h (138 CFM) |
| Inlet Face Velocity | 0.5 m/s (100 fpm) at work surface |
| Filter Configuration | Primary activated carbon filter bed (7-stage configurable adsorption media) + washable polyester pre-filter (20% coarse particle capture efficiency) |
| Noise Level | <55 dBA at operator position |
| Illumination | >800 lux at work surface |
| Construction | 1.2 mm electrogalvanized steel with white thermoset epoxy powder coating |
| Viewing Panel | 6 mm acrylic (frameless, front and side) |
| Work Surface Angle | 13° forward tilt |
| Control System | Sentinel™ microprocessor-based monitoring system |
| Brand | Colloidal Dynamics |
|---|---|
| Origin | USA |
| Model | ZetaProbe |
| Sample Concentration Range | 0.5–60 vol% |
| Zeta Potential Measurement Range | ±500 mV (typical) |
| Particle Size Range for Zeta Measurement | 1 nm – 50 µm |
| pH Range | 0.5–13.5 |
| Conductivity Range | 0–5 S/m |
| Sample Volume | 20–250 mL |
| Measurement Time | <30 s per reading |
| Titration Resolution | 1 µL |
| IEP Detection | Automated via Multi-Point Titration |
| Data Export Format | Native CSV and Excel-Compatible .xls |
Show next