BrandTLS
OriginSpain
ModelT-5333
ApplicationBurst strength testing of paper and paperboard
CategoryPhysical property testing instrument / Tribological tester (burst-specific)
Import statusImported
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
ModelF47900 (2 L) / F48000 (5.8 L)
Temperature Range100–1200 °C
Chamber Volume2 L or 5.8 L
Heating Element LayoutDual-side mounted
Max. Operating Temperature1200 °C
Rear Port Diameter9.5 mm
Control OptionsA1 (single-setpoint), B1 (delayed ramp), C1 (8-segment single program), D1 (16-segment × 4 programs, RS232 interface)
VentingIntegrated exhaust port
ConstructionHeat-treated ceramic chamber lining
ComplianceDesigned for GLP-compliant thermal processing in analytical and materials laboratories
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWEISS
OriginGermany
ModelWK
Chamber Volume Options4–41 m³
Temperature Range+20 °C to +45 °C
Temperature Uniformity≤ ±1 °C
Humidity Range20–80 % RH
Humidity Stability (over time)≤ ±3 % RH
InsulationCFC-free polyurethane (PU)
Control SystemMicroprocessor-based, compliant with GAMP 5 and FDA 21 CFR Part 11
HumidificationUltrasonic
DehumidificationRefrigerant-based
HeatingElectric
CoolingAir-cooled refrigeration
Safety FeaturesDual independent temperature safety cut-offs, sample temperature monitoring, emergency door release
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ModelF6000-60 / F30400-60
Temperature Range100–975 °C
Chamber Volume15 L or 45 L
Air Flow Control0–80 L/min (adjustable via front-mounted flowmeter)
Temperature Stability at 750 °C±3 °C
Heating Rate8 °C/min (≤500 °C), 6 °C/min (500–750 °C)
ComplianceASTM D3174
Gas Inlet Ports1 × 0.95 cm thermocouple port, 1 × 0.635 cm or 0.876 cm soft-hose barb for inert gas supply
Control OptionsB1 (single-setpoint), C1 (8-segment single program), D1 (16-segment × 4 programs, RS232 interface)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
ModelF1600 / F1700 / F1800
Temperature Range150–1360 °C
Chamber Volume5.7–41.4 L
ConstructionHeavy-duty refractory brick lining + reinforced steel cabinet
Heating Element ConfigurationFour-wall embedded in refractory cement
Standard Floor ProtectionCeramic hearth plate
Power SupplyRequires external hardwiring
ControllerSold separately
Safety DesignTop-hinged door with heat-shielded orientation (hot surface directed away from operator)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSievers (Veolia)
OriginUSA
ModelSievers 900
Detection Range0.03 ppb to 50 ppm
Accuracy±2%
Precision<1% RSD
Oxidation MethodUV/Persulfate
Detection MethodMembrane Conductivity
Sample Pressureup to 250 psi
Flow Rate30–300 mL/min
Sample Temperature1–95 °C
Analysis Time4 min (standard), 4 s (rapid module)
IP RatingIP65
ComplianceUS EPA Method 5310C, US EPA 415.3, ASTM D7573
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSievers (Veolia)
OriginUSA
ModelSievers 500RL
Detection Range0.03–2,500 ppb as C
Accuracy±5%
Precision≤0.03 ppb (for <3 ppb) or ≤1% RSD (for ≥3 ppb)
Conductivity Measurement Range0.01–35 µS/cm
Conductivity Accuracy±0.005 µS/cm (≤0.25 µS/cm) or ±2% (>0.25 µS/cm)
Conductivity Precision<0.25% RSD
Max Acceptable Sample Conductivity25 µS/cm at 25°C (neutral pH)
Ozone Tolerance200 ppb
Operating Temperature Range1–95°C (steam-tolerant for short durations)
Added to wishlistRemoved from wishlist 0
Add to compare
KeyOrigin: Germany
ModelMD 1C
Max. Pumping Speed1.3 m³/h
Ultimate Vacuum (absolute)2 mbar
Ultimate Vacuum with Gas Ballast4 mbar
Dimensions (L×W×H)316 × 143 × 175 mm
Weight6.9 kg
Order No.696600
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWEISS
OriginGermany
ModelWK-Series
Chamber Volume Options4 m³, 10 m³, 15 m³, 25 m³, 32 m³, 41 m³
Temperature Range+20 °C to +45 °C
Temperature Uniformity≤ ±1 °C
Humidity Range20 % r.H. to 80 % r.H.
Humidity Stability (over time)≤ ±3 % r.H.
InsulationCFC-free polyurethane (PU) foam
Control SystemMicroprocessor-based, compliant with GAMP 5 and FDA 21 CFR Part 11
HumidificationUltrasonic
DehumidificationRefrigerant-based
Safety FeaturesDual independent temperature safety cut-offs, sample temperature monitoring, emergency door release mechanism
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
ModelFD1500
Temperature Range100–1200 °C
Chamber Volume2.2 L
Heating Elements4 independent embedded in refractory cement
Safety FeaturesDoor-activated power cutoff, dual overtemperature protection (mechanical relay + thermocouple fault detection), adjustable audible alarm
Interface OptionsB1 (single-setpoint digital controller with ramp delay) or C1 (8-segment programmable digital controller)
Rear Port0.95 cm diameter for external temperature monitoring
ConstructionRefractory brick-lined chamber with firebrick door seal
Power CordIncluded
ComplianceDesigned for GLP-compliant weight loss and ashing workflows per ASTM E1868, ISO 1171, and USP <281>
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelSER158
Application CategoryFully Automated Protein and Fat Determination Instrument
Extraction PrincipleRandall Continuous Extraction Technology
Compliance StandardsAOAC 920.39, ISO 1443, ISO 6496, EPA 3541, APHA 5520E, UNI EN ISO 1443
Safety CertificationCE, IEC 61010-1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLWLI
OriginFujian, China
ModelD-Series
Instrument TypeLC-AFS Hyphenated System
Sample IntroductionPeristaltic Pump
Waste DisposalPeristaltic Pump Extraction
Hydride/Vapor Generation ModeOn-line UV Digestion + Chemical Reduction
Target Elements (Total)Hg, As, Se, Sb, Bi, Pb, Cd, Ge, Sn, Te, Zn, Au
Target Species (Speciation)As(III), As(V), MMA, DMA, monomethylmercury (MMHg), ethylmercury (EtHg), Se(IV), Se(VI), selenomethionine, antimony species, etc. (≥12 species)
RSD<0.6%
Linear Dynamic Range>3 orders of magnitude
Detection Limits (ng/L)Hg ≤ 0.001
PMT Wavelength Range160–320 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBINDER
OriginGermany
ModelBD/BF
Temperature Range+5 °C to 99.9 °C (above ambient)
Temperature Accuracy±0.1 °C
Control SystemMicroprocessor-based PID controller with LED display
Timer Function0–99:59 h
Safety DeviceClass 3.1 temperature safety device (DIN 12880)
Communication InterfaceRS422 for APT-COM software integration
Interior DoorSmooth tempered glass
Air CirculationForced convection (BF series)
Sterilization CapabilityDry-heat decontamination at 99 °C
Preconditioning TechnologyAPT-Line® preheating chamber
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBINDER
OriginGermany
Model SeriesMKF / MK / MKT
Internal Volume Options53 L, 115 L, 240 L, 400 L, 720 L
Temperature RangeMK/MKF: −40 °C to +180 °C
MKT−70 °C to +180 °C
M-Series+5 °C above ambient to +300 °C
Humidity Range (MKF only)10–98 % rH
Control SystemMB1 4-channel touchscreen controller (25 programs × 100 segments)
Cooling TechnologyDCT® Direct Cooling Technology
Preconditioning ChamberAPT-Line®
Air CirculationDigitally adjustable high-power turbine
ComplianceDIN EN 60068-3-5, IEC 60068-3-6, ISO 16750-4, ASTM D4329, USP <1151> (environmental stress testing), GLP-compliant data logging via APT-COM software
InterfaceRS422 for APT-COM v3.x integration
InsulationHigh-efficiency vacuum-insulated door & polyurethane foam walls
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTLS
OriginSpain
ModelT-2911
TypeImport
Distributor TypeAuthorized General Distributor
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTLS
OriginSpain
ModelValidator™
TypeCompression Testing Machine for Physical Property Evaluation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFulit
OriginZhejiang, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelF60
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Temperature Control Range6°C to 400°C
Maximum Ramp Rate120°C/min
Cooling Time<7.0 min (from 350°C to 50°C)
Carrier Gas Flow ControlElectronic Flow Display
Carrier Gas Pressure ControlElectronic Pressure Display
Injector Maximum Operating Temperature400°C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFuli
OriginZhejiang, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelF70
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Oven Temperature Range6 °C to 400 °C
Maximum Ramp Rate120 °C/min
Cooling Rate<7.0 min from 350 °C to 50 °C
Carrier Gas Flow Range & Control0–450 mL/min
Carrier Gas Pressure Range & Control0–100 psi
Electronic Pressure Control (EPC), pressure setting resolution0.01 psi
Injector Maximum Operating Temperature400 °C
Injector Pressure Setting Range0–100 psi
Injector Total Flow Setting Range0–450 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandParker
OriginUSA
Model SeriesNitroFlow Lab, N2-04 / N2-14 / N2-22 / N2-35 / N2-45 / N2-80 / N2-135
Flow Rate Range4–467 L/min
Nitrogen Purity≥99.5% (standard models), up to 99.999% (LCMS-SF series)
TechnologyHollow-Fiber Membrane Separation
Power RequirementNone (for air-fed split-system configurations)
CompliancePhthalate-free, VOC-free, MS-compatible design
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLOGAN
OriginUSA
ModelSYSTEM 850DL-12
Instrument TypeOnline Dissolution Tester
Vessel Positions8 or 12
Temperature RangeAmbient to 45 °C ±0.1 °C
Rotation Speed Range25–250 rpm ±0.1 rpm
Pump Configuration12-channel syringe pump (12 × 10 mL)
ComplianceUSP <711>, <724>, <723>, <725>, <731>
Integrated ModulesUDT-812A-12 dissolution apparatus, SCR-160L sample collector, SYP-6L 12-channel syringe pump, DSC-800D sampling controller
Added to wishlistRemoved from wishlist 0
Add to compare
BrandParker
OriginUSA
ModelUHPN2-1100UK / HPN2-2000UK
Flow Rate1.1 L/min (UHPN2-1100UK), 2.0 L/min (HPN2-2000UK)
Purity99.9999% (UHPN2-1100UK), 99.99% (HPN2-2000UK)
InputCompressed Air
CertificationCE, UKCA, ISO 9001-compliant design
DimensionsCompact benchtop footprint (<450 mm W × 400 mm D × 500 mm H)
Power Supply100–240 VAC, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
ModelF30400
Temperature Range100–1093 °C (up to 1200 °C short-term)
Chamber Volume45 L
Heating Element LayoutTop, Bottom, Left & Right Walls
Safety35 A Circuit Breaker + Interlocked Door Switch
Control OptionsB1 (Single-Setpoint), C1 (8-Step Single Program), D1 (16-Step × 4 Programs, RS232)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandESCO
OriginSingapore
ModelSPD-3A1
External Dimensions (W×D×H)840 × 697 × 1110 mm
Airflow Capacity234 m³/h (138 CFM)
Inlet Face Velocity0.5 m/s (100 fpm) at work surface
Filter ConfigurationPrimary activated carbon filter bed (7-stage configurable adsorption media) + washable polyester pre-filter (20% coarse particle capture efficiency)
Noise Level<55 dBA at operator position
Illumination>800 lux at work surface
Construction1.2 mm electrogalvanized steel with white thermoset epoxy powder coating
Viewing Panel6 mm acrylic (frameless, front and side)
Work Surface Angle13° forward tilt
Control SystemSentinel™ microprocessor-based monitoring system
Added to wishlistRemoved from wishlist 0
Add to compare
BrandColloidal Dynamics
OriginUSA
ModelZetaProbe
Sample Concentration Range0.5–60 vol%
Zeta Potential Measurement Range±500 mV (typical)
Particle Size Range for Zeta Measurement1 nm – 50 µm
pH Range0.5–13.5
Conductivity Range0–5 S/m
Sample Volume20–250 mL
Measurement Time<30 s per reading
Titration Resolution1 µL
IEP DetectionAutomated via Multi-Point Titration
Data Export FormatNative CSV and Excel-Compatible .xls