- All
- Favorite
- Popular
- Most rated
| Brand | WEISS |
|---|---|
| Origin | Germany |
| Model | WK |
| Chamber Volume Options | 4–41 m³ |
| Temperature Range | +20 °C to +45 °C |
| Temperature Uniformity | ≤ ±1 °C |
| Humidity Range | 20–80 % RH |
| Humidity Stability (over time) | ≤ ±3 % RH |
| Insulation | CFC-free polyurethane (PU) |
| Control System | Microprocessor-based, compliant with GAMP 5 and FDA 21 CFR Part 11 |
| Humidification | Ultrasonic |
| Dehumidification | Refrigerant-based |
| Heating | Electric |
| Cooling | Air-cooled refrigeration |
| Safety Features | Dual independent temperature safety cut-offs, sample temperature monitoring, emergency door release |
| Brand | WEISS |
|---|---|
| Origin | Germany |
| Model | WK-Series |
| Chamber Volume Options | 4 m³, 10 m³, 15 m³, 25 m³, 32 m³, 41 m³ |
| Temperature Range | +20 °C to +45 °C |
| Temperature Uniformity | ≤ ±1 °C |
| Humidity Range | 20 % r.H. to 80 % r.H. |
| Humidity Stability (over time) | ≤ ±3 % r.H. |
| Insulation | CFC-free polyurethane (PU) foam |
| Control System | Microprocessor-based, compliant with GAMP 5 and FDA 21 CFR Part 11 |
| Humidification | Ultrasonic |
| Dehumidification | Refrigerant-based |
| Safety Features | Dual independent temperature safety cut-offs, sample temperature monitoring, emergency door release mechanism |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model Series | MKF / MK / MKT |
| Internal Volume Options | 53 L, 115 L, 240 L, 400 L, 720 L |
| Temperature Range | MK/MKF: −40 °C to +180 °C |
| MKT | −70 °C to +180 °C |
| M-Series | +5 °C above ambient to +300 °C |
| Humidity Range (MKF only) | 10–98 % rH |
| Control System | MB1 4-channel touchscreen controller (25 programs × 100 segments) |
| Cooling Technology | DCT® Direct Cooling Technology |
| Preconditioning Chamber | APT-Line® |
| Air Circulation | Digitally adjustable high-power turbine |
| Compliance | DIN EN 60068-3-5, IEC 60068-3-6, ISO 16750-4, ASTM D4329, USP <1151> (environmental stress testing), GLP-compliant data logging via APT-COM software |
| Interface | RS422 for APT-COM v3.x integration |
| Insulation | High-efficiency vacuum-insulated door & polyurethane foam walls |
| Brand | WEISS |
|---|---|
| Origin | Germany |
| Model | WK |
| Chamber Volume Options | 4, 10, 15, 25, 32, 41 m³ |
| Temperature Range | +20 to +45 °C |
| Temperature Uniformity | ≤ ±1 °C |
| Humidity Range | 20–80 %RH |
| Humidity Stability (over time) | ≤ ±3 %RH |
| Insulation | CFC-free polyurethane (PU) |
| Control System | Microprocessor-based, compliant with GAMP 5 and FDA 21 CFR Part 11 |
| Humidification | Ultrasonic |
| Dehumidification | Refrigerated |
| Heating | Electric |
| Cooling | Air-cooled refrigeration |
| Safety Features | Dual temperature safety cutoffs, sample temperature monitoring, emergency door release |
| Brand | WEISS |
|---|---|
| Origin | Germany |
| Model | WK |
| Chamber Volume Options | 4, 10, 15, 25, 32, 41 m³ |
| Temperature Range | +20 to +45 °C |
| Temperature Uniformity | ≤ ±1 °C |
| Humidity Range | 20–80 %RH |
| Humidity Stability (over time) | ≤ ±3 %RH |
| Insulation | CFC-free polyurethane (PU) |
| Control System | Microprocessor-based, compliant with GAMP 5 and FDA 21 CFR Part 11 |
| Humidification | Ultrasonic |
| Dehumidification | Refrigerant-based |
| Heating | Electric |
| Cooling | Air-cooled refrigeration |
| Safety Features | Dual temperature monitoring, sample temperature protection, emergency door release |
Show next