BrandLWLI
OriginFujian, China
ModelD-Series
Instrument TypeLC-AFS Hyphenated System
Sample IntroductionPeristaltic Pump
Waste DisposalPeristaltic Pump Extraction
Hydride/Vapor Generation ModeOn-line UV Digestion + Chemical Reduction
Target Elements (Total)Hg, As, Se, Sb, Bi, Pb, Cd, Ge, Sn, Te, Zn, Au
Target Species (Speciation)As(III), As(V), MMA, DMA, monomethylmercury (MMHg), ethylmercury (EtHg), Se(IV), Se(VI), selenomethionine, antimony species, etc. (≥12 species)
RSD<0.6%
Linear Dynamic Range>3 orders of magnitude
Detection Limits (ng/L)Hg ≤ 0.001
PMT Wavelength Range160–320 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFulit
OriginZhejiang, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelF60
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Temperature Control Range6°C to 400°C
Maximum Ramp Rate120°C/min
Cooling Time<7.0 min (from 350°C to 50°C)
Carrier Gas Flow ControlElectronic Flow Display
Carrier Gas Pressure ControlElectronic Pressure Display
Injector Maximum Operating Temperature400°C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFuli
OriginZhejiang, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelF70
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Oven Temperature Range6 °C to 400 °C
Maximum Ramp Rate120 °C/min
Cooling Rate<7.0 min from 350 °C to 50 °C
Carrier Gas Flow Range & Control0–450 mL/min
Carrier Gas Pressure Range & Control0–100 psi
Electronic Pressure Control (EPC), pressure setting resolution0.01 psi
Injector Maximum Operating Temperature400 °C
Injector Pressure Setting Range0–100 psi
Injector Total Flow Setting Range0–450 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFulit
OriginZhejiang, China
ModelF70pro
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-purpose
Oven Temperature Range6 °C to 400 °C
Maximum Ramp Rate120 °C/min
Cooling Rate<3.0 min from 200 °C to 100 °C
Carrier Gas Flow Range & Control0–450 mL/min with Electronic Pressure Control (EPC) for carrier gas and Automatic Flow Control (AFC) for auxiliary gases
Carrier Gas Pressure Range & Control0–100 psi with EPC
pressure control resolution0.001 psi
Injector Maximum Operating Temperature400 °C
Injector Pressure Setting Range0–100 psi
Injector Total Flow Setting Range0–450 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLouis LWL
OriginFujian, China
Manufacturer TypeAuthorized Distributor
Instrument TypeSingle-Channel Atomic Fluorescence Spectrometer
Sample IntroductionPeristaltic Pump
Waste DisposalPeristaltic Pump Extraction
Hydride Generation ModeVapor Generation / Hydride Generation
Detectable ElementsHg, As, Se, Sb, Bi, Pb, Cd, Ge, Sn, Te, Zn, Au
Relative Standard Deviation (RSD)< 0.6%
Linear Dynamic Range> 3 orders of magnitude
Detection LimitsHg ≤ 0.001 µg/L
Photomultiplier Tube Wavelength Range160–320 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFulit
OriginZhejiang, China
ModelF80
Instrument TypeBenchtop Laboratory Gas Chromatograph
Application ScopeGeneral-Purpose GC Analysis
Oven Temperature Range4 °C to 450 °C
Maximum Ramp Rate250 °C/min
Cooling Rate<5.0 min from 450 °C to 50 °C
Carrier Gas Flow Range & Control0–1250 mL/min (H₂ or He), 0–500 mL/min (N₂)
Carrier Gas Pressure Range & Control0–100 psi (standard), optional 0–150 psi
Injector Maximum Operating Temperature450 °C
Injector Pressure Setting Range0–100 psi (standard), optional 0–150 psi
Injector Total Flow Setting Range0–1250 mL/min (H₂/He), 0–500 mL/min (N₂)
Control SystemIntegrated high-resolution touchscreen interface with embedded real-time GC control firmware
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelXGT-7200WR
Detection PrincipleEnergy Dispersive X-Ray Fluorescence (ED-XRF)
Spot Size Range10 µm to 1.2 mm
Detector TypeSilicon Drift Detector (SDD), Liquid-Nitrogen-Free
Maximum Scan Area10 cm × 10 cm
Optical-Element Image Co-RegistrationYes
Elemental Mapping Resolution≤10 µm
ComplianceASTM E1621, ISO 8256, IEC 62321-5 (RoHS), USP <232>/<233>, GLP/GMP-ready data audit trail
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelXGT-5200WR
Sample EnvironmentAir (Atmospheric)
Elemental RangeNa to U
Quantification Range1 ppm – 99.99%
Operating Conditions50 kV / 1 mA
Repeatability±0.1% RSD
Spot SizeStandard 400 µm, Optional 10 µm
DetectorSilicon Drift Detector (SDD), LN2-free
GeometryCoaxial Optical Microscope Integration
Analysis ModeNon-destructive, No Vacuum Required, No Sample Preparation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelMESA-50
Detector TypeSilicon Drift Detector (SDD)
Excitation SourceMicro-focus X-ray Tube
Analytical Spot Sizes0.1 mm, 0.3 mm, and 1.2 mm
Minimum Detection Limit (MDL)≤2 ppm for Pb, Cd, Hg, Cr, Br
Measurement TimeTypically 60–300 s per point
Sample ViewingIntegrated High-Resolution CCD Camera with 30× Optical Zoom
Operating EnvironmentAmbient air (no vacuum or helium required)
Software InterfaceMultilingual (English/Chinese), Excel-compatible data export
Compliance SupportRoHS Directive 2011/65/EU, WEEE Directive 2012/19/EU, ELV Directive 2000/53/EC, China RoHS II (SJ/T 11364-2014), JEITA EG0201, ASTM F2617-23
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnalytik Jena
OriginGermany
ModelPlasmaQuant MS
Instrument TypeFull-Spectrum Direct-Reading ICP-MS
Detection LimitsBe ≤ 0.1 ppt, Co ≤ 0.2 ppt, In ≤ 0.05 ppt, Bi ≤ 0.05 ppt, U ≤ 0.01 ppt
Precision (RSD)< 3%
Short-Term Stability< 3%, Long-Term Stability: < 4%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLouyi SmartLink (LWL)
OriginFujian, China
ModelFL-200
Instrument TypeDual-Channel Hydride Generation Atomic Fluorescence Spectrometer (HG-AFS)
Sample IntroductionPeristaltic Pump
Waste DisposalPeristaltic Pump Extraction
Sample Introduction ModeVapor Generation / Hydride Generation
Detectable ElementsHg, As, Se, Sb, Bi, Pb, Cd, Ge, Sn, Te, Zn, Au
Relative Standard Deviation (RSD)< 0.6%
Linear Dynamic Range> 3 orders of magnitude
Detection LimitsHg ≤ 0.001 µg/L
Photomultiplier Tube Wavelength Range160–320 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFrontier
OriginJapan
ModelEGA/PY3030D
Pyrolyzer TypeMicrofurnace-based Tubular Pyrolyzer
Temperature Range10 °C above ambient to 1050 °C (0.1 °C resolution)
Heating RateProgrammable up to 600 °C/min (8-step temperature program)
Hold Time & Pyrolysis Time0.1–999.9 min (0.1 min step)
CoolingLiquid nitrogen or liquid air
Interface Temperature Control (ITF)40–450 °C (1 °C step)
ReproducibilityRSD < 2% (GC-FID, certified per ASTM D7260 and ISO 17253)
Application ModesEGA, TD, Single-shot Py, TD/PY Double-shot, Heart-cut Release Gas Analysis
Sample Introduction OptionsLiquid injector, Dual-shot injector, Thermal Desorption (TD) module, Derivatization reactor, UV-assisted pyrolysis injector