- All
- Favorite
- Popular
- Most rated
| Brand | LWLI |
|---|---|
| Origin | Fujian, China |
| Model | D-Series |
| Instrument Type | LC-AFS Hyphenated System |
| Sample Introduction | Peristaltic Pump |
| Waste Disposal | Peristaltic Pump Extraction |
| Hydride/Vapor Generation Mode | On-line UV Digestion + Chemical Reduction |
| Target Elements (Total) | Hg, As, Se, Sb, Bi, Pb, Cd, Ge, Sn, Te, Zn, Au |
| Target Species (Speciation) | As(III), As(V), MMA, DMA, monomethylmercury (MMHg), ethylmercury (EtHg), Se(IV), Se(VI), selenomethionine, antimony species, etc. (≥12 species) |
| RSD | <0.6% |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits (ng/L) | Hg ≤ 0.001 |
| PMT Wavelength Range | 160–320 nm |
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | F60 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Temperature Control Range | 6°C to 400°C |
| Maximum Ramp Rate | 120°C/min |
| Cooling Time | <7.0 min (from 350°C to 50°C) |
| Carrier Gas Flow Control | Electronic Flow Display |
| Carrier Gas Pressure Control | Electronic Pressure Display |
| Injector Maximum Operating Temperature | 400°C |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | F70 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 6 °C to 400 °C |
| Maximum Ramp Rate | 120 °C/min |
| Cooling Rate | <7.0 min from 350 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–450 mL/min |
| Carrier Gas Pressure Range & Control | 0–100 psi |
| Electronic Pressure Control (EPC), pressure setting resolution | 0.01 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–100 psi |
| Injector Total Flow Setting Range | 0–450 mL/min |
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Model | F70pro |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | 6 °C to 400 °C |
| Maximum Ramp Rate | 120 °C/min |
| Cooling Rate | <3.0 min from 200 °C to 100 °C |
| Carrier Gas Flow Range & Control | 0–450 mL/min with Electronic Pressure Control (EPC) for carrier gas and Automatic Flow Control (AFC) for auxiliary gases |
| Carrier Gas Pressure Range & Control | 0–100 psi with EPC |
| pressure control resolution | 0.001 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–100 psi |
| Injector Total Flow Setting Range | 0–450 mL/min |
| Brand | Louis LWL |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Single-Channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Peristaltic Pump |
| Waste Disposal | Peristaltic Pump Extraction |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Detectable Elements | Hg, As, Se, Sb, Bi, Pb, Cd, Ge, Sn, Te, Zn, Au |
| Relative Standard Deviation (RSD) | < 0.6% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits | Hg ≤ 0.001 µg/L |
| Photomultiplier Tube Wavelength Range | 160–320 nm |
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Model | F80 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose GC Analysis |
| Oven Temperature Range | 4 °C to 450 °C |
| Maximum Ramp Rate | 250 °C/min |
| Cooling Rate | <5.0 min from 450 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–1250 mL/min (H₂ or He), 0–500 mL/min (N₂) |
| Carrier Gas Pressure Range & Control | 0–100 psi (standard), optional 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–100 psi (standard), optional 0–150 psi |
| Injector Total Flow Setting Range | 0–1250 mL/min (H₂/He), 0–500 mL/min (N₂) |
| Control System | Integrated high-resolution touchscreen interface with embedded real-time GC control firmware |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | XGT-7200WR |
| Detection Principle | Energy Dispersive X-Ray Fluorescence (ED-XRF) |
| Spot Size Range | 10 µm to 1.2 mm |
| Detector Type | Silicon Drift Detector (SDD), Liquid-Nitrogen-Free |
| Maximum Scan Area | 10 cm × 10 cm |
| Optical-Element Image Co-Registration | Yes |
| Elemental Mapping Resolution | ≤10 µm |
| Compliance | ASTM E1621, ISO 8256, IEC 62321-5 (RoHS), USP <232>/<233>, GLP/GMP-ready data audit trail |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | XGT-5200WR |
| Sample Environment | Air (Atmospheric) |
| Elemental Range | Na to U |
| Quantification Range | 1 ppm – 99.99% |
| Operating Conditions | 50 kV / 1 mA |
| Repeatability | ±0.1% RSD |
| Spot Size | Standard 400 µm, Optional 10 µm |
| Detector | Silicon Drift Detector (SDD), LN2-free |
| Geometry | Coaxial Optical Microscope Integration |
| Analysis Mode | Non-destructive, No Vacuum Required, No Sample Preparation |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | MESA-50 |
| Detector Type | Silicon Drift Detector (SDD) |
| Excitation Source | Micro-focus X-ray Tube |
| Analytical Spot Sizes | 0.1 mm, 0.3 mm, and 1.2 mm |
| Minimum Detection Limit (MDL) | ≤2 ppm for Pb, Cd, Hg, Cr, Br |
| Measurement Time | Typically 60–300 s per point |
| Sample Viewing | Integrated High-Resolution CCD Camera with 30× Optical Zoom |
| Operating Environment | Ambient air (no vacuum or helium required) |
| Software Interface | Multilingual (English/Chinese), Excel-compatible data export |
| Compliance Support | RoHS Directive 2011/65/EU, WEEE Directive 2012/19/EU, ELV Directive 2000/53/EC, China RoHS II (SJ/T 11364-2014), JEITA EG0201, ASTM F2617-23 |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | PlasmaQuant MS |
| Instrument Type | Full-Spectrum Direct-Reading ICP-MS |
| Detection Limits | Be ≤ 0.1 ppt, Co ≤ 0.2 ppt, In ≤ 0.05 ppt, Bi ≤ 0.05 ppt, U ≤ 0.01 ppt |
| Precision (RSD) | < 3% |
| Short-Term Stability | < 3%, Long-Term Stability: < 4% |
| Brand | Louyi SmartLink (LWL) |
|---|---|
| Origin | Fujian, China |
| Model | FL-200 |
| Instrument Type | Dual-Channel Hydride Generation Atomic Fluorescence Spectrometer (HG-AFS) |
| Sample Introduction | Peristaltic Pump |
| Waste Disposal | Peristaltic Pump Extraction |
| Sample Introduction Mode | Vapor Generation / Hydride Generation |
| Detectable Elements | Hg, As, Se, Sb, Bi, Pb, Cd, Ge, Sn, Te, Zn, Au |
| Relative Standard Deviation (RSD) | < 0.6% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits | Hg ≤ 0.001 µg/L |
| Photomultiplier Tube Wavelength Range | 160–320 nm |
| Brand | Frontier |
|---|---|
| Origin | Japan |
| Model | EGA/PY3030D |
| Pyrolyzer Type | Microfurnace-based Tubular Pyrolyzer |
| Temperature Range | 10 °C above ambient to 1050 °C (0.1 °C resolution) |
| Heating Rate | Programmable up to 600 °C/min (8-step temperature program) |
| Hold Time & Pyrolysis Time | 0.1–999.9 min (0.1 min step) |
| Cooling | Liquid nitrogen or liquid air |
| Interface Temperature Control (ITF) | 40–450 °C (1 °C step) |
| Reproducibility | RSD < 2% (GC-FID, certified per ASTM D7260 and ISO 17253) |
| Application Modes | EGA, TD, Single-shot Py, TD/PY Double-shot, Heart-cut Release Gas Analysis |
| Sample Introduction Options | Liquid injector, Dual-shot injector, Thermal Desorption (TD) module, Derivatization reactor, UV-assisted pyrolysis injector |
Show next