- All
- Favorite
- Popular
- Most rated
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | F60 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Temperature Control Range | 6°C to 400°C |
| Maximum Ramp Rate | 120°C/min |
| Cooling Time | <7.0 min (from 350°C to 50°C) |
| Carrier Gas Flow Control | Electronic Flow Display |
| Carrier Gas Pressure Control | Electronic Pressure Display |
| Injector Maximum Operating Temperature | 400°C |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | F70 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 6 °C to 400 °C |
| Maximum Ramp Rate | 120 °C/min |
| Cooling Rate | <7.0 min from 350 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–450 mL/min |
| Carrier Gas Pressure Range & Control | 0–100 psi |
| Electronic Pressure Control (EPC), pressure setting resolution | 0.01 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–100 psi |
| Injector Total Flow Setting Range | 0–450 mL/min |
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Model | F70pro |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | 6 °C to 400 °C |
| Maximum Ramp Rate | 120 °C/min |
| Cooling Rate | <3.0 min from 200 °C to 100 °C |
| Carrier Gas Flow Range & Control | 0–450 mL/min with Electronic Pressure Control (EPC) for carrier gas and Automatic Flow Control (AFC) for auxiliary gases |
| Carrier Gas Pressure Range & Control | 0–100 psi with EPC |
| pressure control resolution | 0.001 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–100 psi |
| Injector Total Flow Setting Range | 0–450 mL/min |
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Model | F80 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose GC Analysis |
| Oven Temperature Range | 4 °C to 450 °C |
| Maximum Ramp Rate | 250 °C/min |
| Cooling Rate | <5.0 min from 450 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–1250 mL/min (H₂ or He), 0–500 mL/min (N₂) |
| Carrier Gas Pressure Range & Control | 0–100 psi (standard), optional 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–100 psi (standard), optional 0–150 psi |
| Injector Total Flow Setting Range | 0–1250 mL/min (H₂/He), 0–500 mL/min (N₂) |
| Control System | Integrated high-resolution touchscreen interface with embedded real-time GC control firmware |