Empowering Scientific Discovery

Louis Enterprise Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFulit
OriginZhejiang, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelF60
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Temperature Control Range6°C to 400°C
Maximum Ramp Rate120°C/min
Cooling Time<7.0 min (from 350°C to 50°C)
Carrier Gas Flow ControlElectronic Flow Display
Carrier Gas Pressure ControlElectronic Pressure Display
Injector Maximum Operating Temperature400°C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFuli
OriginZhejiang, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelF70
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Oven Temperature Range6 °C to 400 °C
Maximum Ramp Rate120 °C/min
Cooling Rate<7.0 min from 350 °C to 50 °C
Carrier Gas Flow Range & Control0–450 mL/min
Carrier Gas Pressure Range & Control0–100 psi
Electronic Pressure Control (EPC), pressure setting resolution0.01 psi
Injector Maximum Operating Temperature400 °C
Injector Pressure Setting Range0–100 psi
Injector Total Flow Setting Range0–450 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFulit
OriginZhejiang, China
ModelF70pro
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-purpose
Oven Temperature Range6 °C to 400 °C
Maximum Ramp Rate120 °C/min
Cooling Rate<3.0 min from 200 °C to 100 °C
Carrier Gas Flow Range & Control0–450 mL/min with Electronic Pressure Control (EPC) for carrier gas and Automatic Flow Control (AFC) for auxiliary gases
Carrier Gas Pressure Range & Control0–100 psi with EPC
pressure control resolution0.001 psi
Injector Maximum Operating Temperature400 °C
Injector Pressure Setting Range0–100 psi
Injector Total Flow Setting Range0–450 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFulit
OriginZhejiang, China
ModelF80
Instrument TypeBenchtop Laboratory Gas Chromatograph
Application ScopeGeneral-Purpose GC Analysis
Oven Temperature Range4 °C to 450 °C
Maximum Ramp Rate250 °C/min
Cooling Rate<5.0 min from 450 °C to 50 °C
Carrier Gas Flow Range & Control0–1250 mL/min (H₂ or He), 0–500 mL/min (N₂)
Carrier Gas Pressure Range & Control0–100 psi (standard), optional 0–150 psi
Injector Maximum Operating Temperature450 °C
Injector Pressure Setting Range0–100 psi (standard), optional 0–150 psi
Injector Total Flow Setting Range0–1250 mL/min (H₂/He), 0–500 mL/min (N₂)
Control SystemIntegrated high-resolution touchscreen interface with embedded real-time GC control firmware