- All
- Favorite
- Popular
- Most rated
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | Sievers 900 |
| Detection Range | 0.03 ppb to 50 ppm |
| Accuracy | ±2% |
| Precision | <1% RSD |
| Oxidation Method | UV/Persulfate |
| Detection Method | Membrane Conductivity |
| Sample Pressure | up to 250 psi |
| Flow Rate | 30–300 mL/min |
| Sample Temperature | 1–95 °C |
| Analysis Time | 4 min (standard), 4 s (rapid module) |
| IP Rating | IP65 |
| Compliance | US EPA Method 5310C, US EPA 415.3, ASTM D7573 |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | Sievers 500RL |
| Detection Range | 0.03–2,500 ppb as C |
| Accuracy | ±5% |
| Precision | ≤0.03 ppb (for <3 ppb) or ≤1% RSD (for ≥3 ppb) |
| Conductivity Measurement Range | 0.01–35 µS/cm |
| Conductivity Accuracy | ±0.005 µS/cm (≤0.25 µS/cm) or ±2% (>0.25 µS/cm) |
| Conductivity Precision | <0.25% RSD |
| Max Acceptable Sample Conductivity | 25 µS/cm at 25°C (neutral pH) |
| Ozone Tolerance | 200 ppb |
| Operating Temperature Range | 1–95°C (steam-tolerant for short durations) |
| Brand | Sievers/Veolia |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | CheckPoint |
| Pricing | Available Upon Request |
| Detection Range | 0.05–1,000 ppb C |
| Precision | Greater of <1% RSD or 0.05 ppb (online, 20–40 °C) |
| Analysis Modes | Online continuous averaging, online timed sampling, offline grab sampling |
| Analysis Time | 15 s (online), 10 min (grab) |
| TOC Calibration Interval | 6 months |
| Conductivity Tolerance | Up to 1.4 µS/cm (0.7 MΩ·cm) CO₂-compensated conductivity |
| Conductivity Precision | ±0.5% RSD (20–40 °C) |
| Conductivity Accuracy | ±2.0% |
| Conductivity Calibration Interval | 6 months |
| Operating Pressure (Online) | 15–100 psi |
| Low-Pressure Sampling | Max. 0.70 m head above analyzer |
| Minimum Online Flow Rate | >60 mL/min |
| Power Supply | 100–240 V ±10%, 60 W, 50/60 Hz |
| Sample Temperature Range | 10–90 °C |
| Ambient Operating Temperature | 10–40 °C |
| Enclosure Rating | Indoor use only |
| I/O Options | Ethernet, 2 analog outputs, 2 alarm outputs, parallel inputs |
| Installation Category | Overvoltage Category II |
| Dimensions (H×W×D) | 25.4 × 30.48 × 15.24 cm (standard) |
| Weight | 2.9 kg (no battery), 3.58 kg (with battery), +0.6 kg (vial sampler) |
| Safety Certifications | CE, ETL Listed |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | InnovOx |
| Detection Range | 0.05–50,000 ppm TOC |
| LOD | 0.05 ppm TOC |
| Accuracy | ±3% at 50 mg/L NPOC |
| Precision | RSD <5% at 50 mg/L NPOC |
| Linearity | R² >0.995 |
| Analysis Time | 2.2–7.3 min |
| Calibration Stability | 6 months |
| Particle Tolerance | <800 µm |
| Operating Temp | 10–40 °C |
| Sample Temp | 10–60 °C |
| Humidity | ≤95% RH (non-condensing) |
| Power | 100–240 VAC ±10%, 400 W, 50/60 Hz |
| Dimensions | 52.05 × 32.26 × 58.42 cm |
| Weight | 22.4 kg |
| Interface | Ethernet + 3 USB ports |
| Display | Color touchscreen |
Show next