BrandMalvern PANalytical
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeLaboratory Laser Diffraction Particle Size Analyzer
Measurement Range0.1–1000 µm
Repeatability<1% RSD
Measurement Time<10 seconds per analysis
Dispersion MethodDry and Wet Dispersion
Data Acquisition Rate10 kHz
Laser SourceStabilized He-Ne Laser (632.8 nm)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern Panalytical
OriginUSA
ManufacturerMicromeritics Instrument Corp.
ModelASAP 2460 Series
Analysis Stations2–6 (modular expansion)
Measurement PrincipleStatic gas adsorption (volumetric method)
Pore Size Range0.35–500 nm
Pressure Range0–1000 mmHg (absolute)
Theoretical BasisBET, t-plot, Langmuir, DFT, NLDFT, BJH, HK, SF
Optional ConfigurationsLow-surface-area (Kr adsorption, 10 mmHg transducer) and micropore (1 mmHg transducer, N₂/Ar/CO₂/H₂ capability)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern Panalytical
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported Instrument
ModelMicroCal PEAQ-DSC
Sample ThroughputMultiple samples per run (manual loading)
Instrument TypeDifferential Scanning Calorimeter (DSC)
Temperature Range–10 °C to 130 °C (expandable)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern Panalytical
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
ModelHydro Insight
Instrument TypeDynamic Imaging System
Measurement Range (Standard Magnification)1–300 µm
Measurement Range (Low Magnification)10–800 µm
Dispersion MethodWet Dispersion
Camera Resolution5 MP (2592 × 1944 pixels, 2.2 µm pixel size)
Measured ParametersParticle Images, Shape Metrics (31 shape descriptors), Width, Elongation, Aspect Ratio, Circularity, Convexity, Solidity, etc.
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern PANalytical
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
Model OptionsBlue Label and Red Label configurations
Particle Size Range0.3 nm – 15 µm
Size Measurement Repeatability±2%
Temperature Control Range10–35 °C
Temperature Stability±0.1 °C
Detection Angle90° (Classical Dynamic Light Scattering)
Minimum Sample Volume3 µL
Sample Concentration Range0.1 mg/mL – 40% w/v
Zeta Potential RangeNo practical lower or upper limit
Typical Measurement Time3–5 minutes per analysis
Molecular Weight Range980 Da – 20 MDa
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern Panalytical
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
Model OptionsBlue Label and Red Label configurations
Particle Size Range0.3 nm – 10 µm
Size Measurement Repeatability±2%
Temperature Control Range10–35 °C
Temperature Stability±0.1 °C
Detection PrincipleNon-Invasive Back Scatter (NIBS) Dynamic Light Scattering (DLS)
Minimum Sample Volume12 µL
Sample Concentration Range0.1 mg/mL – 40% w/v
Zeta Potential RangeNo practical lower or upper limit under standard operational conditions
Typical Measurement Time3–5 minutes per analysis
Molecular Weight Range980 Da – 20 MDa
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern Panalytical
OriginUSA
ManufacturerMicromeritics Instrument Corp.
TypeSpecific Surface Area and Pore Size Analyzer
PrincipleStatic and Dynamic Gas Sorption
Number of Analysis Stations3
Micropore Range< 2 nm
Steam Adsorption CapabilityStandard
Chemisorption OptionsStatic, Dynamic (TPR/TPO/TPD/TPSR), Pulse
Temperature Control RangeUp to 1100 °C (±1 °C)
Pressure SensingUltra-low-range 0.1 Torr sensor for micropore analysis
Vacuum PerformanceMetal-sealed manifold with ultra-low outgassing rate
SoftwareMicroActive™ Data Reduction Suite
ComplianceASTM D3663, ISO 9277, ISO 15901, USP <846>, IUPAC Recommendations
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern PANalytical
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
Model VariantsBlue Label and Red Label
Particle Size Range0.3 nm – 15 µm
Size Measurement Repeatability±2%
Temperature Control Range10–35 °C
Temperature Stability±0.1 °C
Detection MethodNon-Invasive Back Scatter (NIBS) DLS and Multi-Angle Dynamic Light Scattering (MADLS®)
Minimum Sample Volume3 µL
Sample Concentration Range0.1 mg/mL – 40% w/v
Zeta Potential RangeNo practical lower or upper limit
Typical Measurement Time3–5 minutes
Molecular Weight Range980 Da – 20 MDa
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern Panalytical
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
ModelMastersizer 3000
Dispersion MethodDry & Wet Dispersion
Instrument TypeLaboratory Laser Diffraction Analyzer
Measurement Range0.01–3500 µm
Repeatability<1% RSD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern PANalytical
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelMicroCal PEAQ-DSC Automated
Sample ThroughputUp to 50 samples per unattended run
Instrument TypeDifferential Scanning Calorimeter (DSC)
Temperature Range–10 °C to 130 °C (expandable)
Sample FormatStandard 96-well microplate compatibility
Regulatory ComplianceDesigned for 21 CFR Part 11 and EU GMP Annex 11 compliance support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern Panalytical
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
ModelNS300
PricingAvailable upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern PANalytical
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
ModelMastersizer 3000+
Dispersion MethodDry and Wet Dispersion
Instrument TypeLaboratory Laser Diffraction Particle Size Analyzer
Measurement Range0.01–3500 µm
Repeatability<1% RSD
Measurement Time<10 s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern PANalytical
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
ModelMorphologi 4
Instrument TypeStatic Image-Based Particle Analyzer
Lens Count5
Measurement Range0.5 µm – 1300 µm
Sample Dispersion MethodsDry Powder Dispersion and Wet Dispersion
Image Resolution18 MP
Measured Morphological ParametersAspect Ratio, Circularity, Convexity, Extent, Hardness
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern Panalytical
OriginUSA
ManufacturerMicromeritics Instrument Corp.
ModelAutoChem III
Gas Inlet Ports18
Temperature RangeAmbient to 1200 °C
Ramp RateUp to 100 °C/min from –100 °C to 800 °C
Core FunctionsPulse Chemisorption, Temperature-Programmed Reduction (TPR), Single-Point BET Surface Area Analysis
ComplianceDesigned for GLP/GMP environments with audit-trail-ready software architecture
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern PANalytical
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelNanoSight Pro
PriceUpon Request
Particle Size Range10 nm – 1000 nm
Temperature Control Range5°C below ambient to 70°C
Measurement PrincipleNanoparticle Tracking Analysis (NTA)
Sample Concentration Range1×10⁶ – 1×10⁹ particles/mL
Minimum Sample Volume250 µL
Laser Wavelengths405 nm (<70 mW), 488 nm (<55 mW), 532 nm (<60 mW), 642 nm (<50 mW)
Detection CameraHigh-sensitivity sCMOS (USB 3.0)
ComplianceClass 1 Laser Product (BS EN 60825-1:2014), EMC Directive (EN IEC 61326-1:2021), Low Voltage Directive (IEC 61010-1:2010 + AMD1:2016)
Dimensions (W×D×H)34 × 35 × 25 cm
Weight11 kg (instrument), 1.6 kg (laser module)
Power SupplyAC 110–240 V, 50–60 Hz, 4.0 A
Operating Environment≤80% RH at 31°C, linearly decreasing to 50% RH at 40°C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern Panalytical
OriginUSA
ManufacturerMicromeritics Instrument Corp.
ModelMicromeritics ChemiSorb Auto
Instrument TypeChemisorption Analyzer
Measurement PrincipleFlow Method
Number of Gas Inlets8 (4 Carrier + 4 Loop)
Maximum Heating Temperature1000 °C
Programmable Heating Rate1–50 °C/min (with CryoCooler option enabling -100 °C to 1000 °C range)
Supported TechniquesTemperature-Programmed Reduction (TPR), Temperature-Programmed Oxidation (TPO), Temperature-Programmed Desorption (TPD), Pulse Chemisorption, TPSR, Strong Metal-Support Interaction (SMSI) analysis, Acid Site Strength Distribution (Lewis/Brønsted), BET Surface Area
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern Panalytical
OriginUSA
ManufacturerMicromeritics Instrument Corporation
Instrument TypeSpecific Surface Area and Pore Size Analyzer
Number of Analysis Stations1–3
Gas OptionsN₂, Kr, Ar, CO₂, CH₄, C₄H₁₀ (non-corrosive)
Minimum Surface Area (N₂)0.01 m²/g
Minimum Surface Area (Kr)0.001 m²/g
Minimum Pore Volume4 × 10⁻⁶ cm³/g
Dewar Capacity2.75 L (optional 4 L)
Continuous Analysis Durationup to 40 h
Data Points per Isothermup to 1000
P₀ Measurementintegrated, continuous or manual input
Free Space Determinationmeasured, calculated, or user-defined
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern PANalytical
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
ModelMorphologi 4-ID
Application SectorPharmaceutical
Instrument TypeStatic Imaging Analyzer
Number of Objective Lenses5
Measurement Range0.5 µm – 1300 µm
Dispersion MethodsDry Powder Dispersion and Wet Dispersion
Image Resolution18 Megapixels
Measured Morphological ParametersAspect Ratio, Circularity, Convexity, Elongation, Hardness
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern Panalytical
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelMicroCal PEAQ-ITC Automated
Measurement ModeIsothermal Titration Calorimetry (ITC)
Temperature Range2 °C to 80 °C
Sample Volume RequirementAs low as 10 μg protein per experiment
ThroughputFully automated operation supporting up to four 96-well plates per unattended run
Detection SensitivitySub-micromolar to picomolar dissociation constants (KD = 10⁻² – 10⁻¹² M)
Cell MaterialChemically resistant nickel-based alloy
Cell GeometryOptimized coin-shaped reaction cell for efficient mixing and minimal sample dispersion
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern Panalytical
OriginUSA
ManufacturerMicromeritics Instrument Corporation
ModelAccuPyc III 1350
Instrument TypeTrue Density Analyzer
Form FactorBenchtop Laboratory System
Sample TypeSolid Materials
Density Range0.1–100 cm³ (sample volume)
Density Accuracy±0.02%
Temperature Control Range4 °C to 60 °C, stability ±0.025 °C
Repeatability±0.01%
Minimum Sample Volume0.1 cm³
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern Panalytical
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
ModelSpraytec
Dispersion MethodWet Dispersion
Instrument TypeLaboratory Laser Diffraction Particle Size Analyzer
Measurement Range0.5 µm @ 150 mm path length
RepeatabilityDv50 better than ±1% COV (NIST-traceable latex standards)
Measurement DurationFast Mode: 30 seconds
Continuous Modeup to 60 minutes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern Panalytical
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported Instrument
ModelZetasizer Sample Assistant
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern PANalytical
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported Instrument
ModelMicroCal PEAQ-ITC
Measurement ModeIsothermal Titration Calorimetry (ITC)
Temperature Range2 °C to 80 °C
Sample ConsumptionAs low as 10 µg protein per experiment
Affinity Range10² M⁻¹ to 10¹² M⁻¹ (K<sub>D</sub> = 10⁻² to 10⁻¹² M)
CompatibilityAqueous and non-aqueous solvents
Cell MaterialChemically resistant nickel-based alloy
Upgrade PathCompatible with MicroCal PEAQ-ITC Automated platform