- All
- Favorite
- Popular
- Most rated
| Brand | Malvern PANalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.1–1000 µm |
| Repeatability | <1% RSD |
| Measurement Time | <10 seconds per analysis |
| Dispersion Method | Dry and Wet Dispersion |
| Data Acquisition Rate | 10 kHz |
| Laser Source | Stabilized He-Ne Laser (632.8 nm) |
| Brand | Malvern Panalytical |
|---|---|
| Origin | USA |
| Manufacturer | Micromeritics Instrument Corp. |
| Model | ASAP 2460 Series |
| Analysis Stations | 2–6 (modular expansion) |
| Measurement Principle | Static gas adsorption (volumetric method) |
| Pore Size Range | 0.35–500 nm |
| Pressure Range | 0–1000 mmHg (absolute) |
| Theoretical Basis | BET, t-plot, Langmuir, DFT, NLDFT, BJH, HK, SF |
| Optional Configurations | Low-surface-area (Kr adsorption, 10 mmHg transducer) and micropore (1 mmHg transducer, N₂/Ar/CO₂/H₂ capability) |
| Brand | Malvern Panalytical |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | MicroCal PEAQ-DSC |
| Sample Throughput | Multiple samples per run (manual loading) |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –10 °C to 130 °C (expandable) |
| Brand | Malvern Panalytical |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Hydro Insight |
| Instrument Type | Dynamic Imaging System |
| Measurement Range (Standard Magnification) | 1–300 µm |
| Measurement Range (Low Magnification) | 10–800 µm |
| Dispersion Method | Wet Dispersion |
| Camera Resolution | 5 MP (2592 × 1944 pixels, 2.2 µm pixel size) |
| Measured Parameters | Particle Images, Shape Metrics (31 shape descriptors), Width, Elongation, Aspect Ratio, Circularity, Convexity, Solidity, etc. |
| Brand | Malvern PANalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model Options | Blue Label and Red Label configurations |
| Particle Size Range | 0.3 nm – 15 µm |
| Size Measurement Repeatability | ±2% |
| Temperature Control Range | 10–35 °C |
| Temperature Stability | ±0.1 °C |
| Detection Angle | 90° (Classical Dynamic Light Scattering) |
| Minimum Sample Volume | 3 µL |
| Sample Concentration Range | 0.1 mg/mL – 40% w/v |
| Zeta Potential Range | No practical lower or upper limit |
| Typical Measurement Time | 3–5 minutes per analysis |
| Molecular Weight Range | 980 Da – 20 MDa |
| Brand | Malvern Panalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model Options | Blue Label and Red Label configurations |
| Particle Size Range | 0.3 nm – 10 µm |
| Size Measurement Repeatability | ±2% |
| Temperature Control Range | 10–35 °C |
| Temperature Stability | ±0.1 °C |
| Detection Principle | Non-Invasive Back Scatter (NIBS) Dynamic Light Scattering (DLS) |
| Minimum Sample Volume | 12 µL |
| Sample Concentration Range | 0.1 mg/mL – 40% w/v |
| Zeta Potential Range | No practical lower or upper limit under standard operational conditions |
| Typical Measurement Time | 3–5 minutes per analysis |
| Molecular Weight Range | 980 Da – 20 MDa |
| Brand | Malvern Panalytical |
|---|---|
| Origin | USA |
| Manufacturer | Micromeritics Instrument Corp. |
| Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static and Dynamic Gas Sorption |
| Number of Analysis Stations | 3 |
| Micropore Range | < 2 nm |
| Steam Adsorption Capability | Standard |
| Chemisorption Options | Static, Dynamic (TPR/TPO/TPD/TPSR), Pulse |
| Temperature Control Range | Up to 1100 °C (±1 °C) |
| Pressure Sensing | Ultra-low-range 0.1 Torr sensor for micropore analysis |
| Vacuum Performance | Metal-sealed manifold with ultra-low outgassing rate |
| Software | MicroActive™ Data Reduction Suite |
| Compliance | ASTM D3663, ISO 9277, ISO 15901, USP <846>, IUPAC Recommendations |
| Brand | Malvern PANalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model Variants | Blue Label and Red Label |
| Particle Size Range | 0.3 nm – 15 µm |
| Size Measurement Repeatability | ±2% |
| Temperature Control Range | 10–35 °C |
| Temperature Stability | ±0.1 °C |
| Detection Method | Non-Invasive Back Scatter (NIBS) DLS and Multi-Angle Dynamic Light Scattering (MADLS®) |
| Minimum Sample Volume | 3 µL |
| Sample Concentration Range | 0.1 mg/mL – 40% w/v |
| Zeta Potential Range | No practical lower or upper limit |
| Typical Measurement Time | 3–5 minutes |
| Molecular Weight Range | 980 Da – 20 MDa |
| Brand | Malvern Panalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Mastersizer 3000 |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Analyzer |
| Measurement Range | 0.01–3500 µm |
| Repeatability | <1% RSD |
| Brand | Malvern PANalytical |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | MicroCal PEAQ-DSC Automated |
| Sample Throughput | Up to 50 samples per unattended run |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –10 °C to 130 °C (expandable) |
| Sample Format | Standard 96-well microplate compatibility |
| Regulatory Compliance | Designed for 21 CFR Part 11 and EU GMP Annex 11 compliance support |
| Brand | Malvern Panalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | NS300 |
| Pricing | Available upon Request |
| Brand | Malvern PANalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Mastersizer 3000+ |
| Dispersion Method | Dry and Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.01–3500 µm |
| Repeatability | <1% RSD |
| Measurement Time | <10 s |
| Brand | Malvern PANalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Morphologi 4 |
| Instrument Type | Static Image-Based Particle Analyzer |
| Lens Count | 5 |
| Measurement Range | 0.5 µm – 1300 µm |
| Sample Dispersion Methods | Dry Powder Dispersion and Wet Dispersion |
| Image Resolution | 18 MP |
| Measured Morphological Parameters | Aspect Ratio, Circularity, Convexity, Extent, Hardness |
| Brand | Malvern Panalytical |
|---|---|
| Origin | USA |
| Manufacturer | Micromeritics Instrument Corp. |
| Model | AutoChem III |
| Gas Inlet Ports | 18 |
| Temperature Range | Ambient to 1200 °C |
| Ramp Rate | Up to 100 °C/min from –100 °C to 800 °C |
| Core Functions | Pulse Chemisorption, Temperature-Programmed Reduction (TPR), Single-Point BET Surface Area Analysis |
| Compliance | Designed for GLP/GMP environments with audit-trail-ready software architecture |
| Brand | Malvern PANalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | NanoSight Pro |
| Price | Upon Request |
| Particle Size Range | 10 nm – 1000 nm |
| Temperature Control Range | 5°C below ambient to 70°C |
| Measurement Principle | Nanoparticle Tracking Analysis (NTA) |
| Sample Concentration Range | 1×10⁶ – 1×10⁹ particles/mL |
| Minimum Sample Volume | 250 µL |
| Laser Wavelengths | 405 nm (<70 mW), 488 nm (<55 mW), 532 nm (<60 mW), 642 nm (<50 mW) |
| Detection Camera | High-sensitivity sCMOS (USB 3.0) |
| Compliance | Class 1 Laser Product (BS EN 60825-1:2014), EMC Directive (EN IEC 61326-1:2021), Low Voltage Directive (IEC 61010-1:2010 + AMD1:2016) |
| Dimensions (W×D×H) | 34 × 35 × 25 cm |
| Weight | 11 kg (instrument), 1.6 kg (laser module) |
| Power Supply | AC 110–240 V, 50–60 Hz, 4.0 A |
| Operating Environment | ≤80% RH at 31°C, linearly decreasing to 50% RH at 40°C |
| Brand | Malvern Panalytical |
|---|---|
| Origin | USA |
| Manufacturer | Micromeritics Instrument Corp. |
| Model | Micromeritics ChemiSorb Auto |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Flow Method |
| Number of Gas Inlets | 8 (4 Carrier + 4 Loop) |
| Maximum Heating Temperature | 1000 °C |
| Programmable Heating Rate | 1–50 °C/min (with CryoCooler option enabling -100 °C to 1000 °C range) |
| Supported Techniques | Temperature-Programmed Reduction (TPR), Temperature-Programmed Oxidation (TPO), Temperature-Programmed Desorption (TPD), Pulse Chemisorption, TPSR, Strong Metal-Support Interaction (SMSI) analysis, Acid Site Strength Distribution (Lewis/Brønsted), BET Surface Area |
| Brand | Malvern Panalytical |
|---|---|
| Origin | USA |
| Manufacturer | Micromeritics Instrument Corporation |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Number of Analysis Stations | 1–3 |
| Gas Options | N₂, Kr, Ar, CO₂, CH₄, C₄H₁₀ (non-corrosive) |
| Minimum Surface Area (N₂) | 0.01 m²/g |
| Minimum Surface Area (Kr) | 0.001 m²/g |
| Minimum Pore Volume | 4 × 10⁻⁶ cm³/g |
| Dewar Capacity | 2.75 L (optional 4 L) |
| Continuous Analysis Duration | up to 40 h |
| Data Points per Isotherm | up to 1000 |
| P₀ Measurement | integrated, continuous or manual input |
| Free Space Determination | measured, calculated, or user-defined |
| Brand | Malvern PANalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Morphologi 4-ID |
| Application Sector | Pharmaceutical |
| Instrument Type | Static Imaging Analyzer |
| Number of Objective Lenses | 5 |
| Measurement Range | 0.5 µm – 1300 µm |
| Dispersion Methods | Dry Powder Dispersion and Wet Dispersion |
| Image Resolution | 18 Megapixels |
| Measured Morphological Parameters | Aspect Ratio, Circularity, Convexity, Elongation, Hardness |
| Brand | Malvern Panalytical |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MicroCal PEAQ-ITC Automated |
| Measurement Mode | Isothermal Titration Calorimetry (ITC) |
| Temperature Range | 2 °C to 80 °C |
| Sample Volume Requirement | As low as 10 μg protein per experiment |
| Throughput | Fully automated operation supporting up to four 96-well plates per unattended run |
| Detection Sensitivity | Sub-micromolar to picomolar dissociation constants (KD = 10⁻² – 10⁻¹² M) |
| Cell Material | Chemically resistant nickel-based alloy |
| Cell Geometry | Optimized coin-shaped reaction cell for efficient mixing and minimal sample dispersion |
| Brand | Malvern Panalytical |
|---|---|
| Origin | USA |
| Manufacturer | Micromeritics Instrument Corporation |
| Model | AccuPyc III 1350 |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop Laboratory System |
| Sample Type | Solid Materials |
| Density Range | 0.1–100 cm³ (sample volume) |
| Density Accuracy | ±0.02% |
| Temperature Control Range | 4 °C to 60 °C, stability ±0.025 °C |
| Repeatability | ±0.01% |
| Minimum Sample Volume | 0.1 cm³ |
| Brand | Malvern Panalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Spraytec |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.5 µm @ 150 mm path length |
| Repeatability | Dv50 better than ±1% COV (NIST-traceable latex standards) |
| Measurement Duration | Fast Mode: 30 seconds |
| Continuous Mode | up to 60 minutes |
| Brand | Malvern Panalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Zetasizer Sample Assistant |
| Pricing | Available Upon Request |
| Brand | Malvern PANalytical |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | MicroCal PEAQ-ITC |
| Measurement Mode | Isothermal Titration Calorimetry (ITC) |
| Temperature Range | 2 °C to 80 °C |
| Sample Consumption | As low as 10 µg protein per experiment |
| Affinity Range | 10² M⁻¹ to 10¹² M⁻¹ (K<sub>D</sub> = 10⁻² to 10⁻¹² M) |
| Compatibility | Aqueous and non-aqueous solvents |
| Cell Material | Chemically resistant nickel-based alloy |
| Upgrade Path | Compatible with MicroCal PEAQ-ITC Automated platform |
Show next