| Brand | Malvern PANalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model Options | Blue Label and Red Label configurations |
| Particle Size Range | 0.3 nm – 15 µm |
| Size Measurement Repeatability | ±2% |
| Temperature Control Range | 10–35 °C |
| Temperature Stability | ±0.1 °C |
| Detection Angle | 90° (Classical Dynamic Light Scattering) |
| Minimum Sample Volume | 3 µL |
| Sample Concentration Range | 0.1 mg/mL – 40% w/v |
| Zeta Potential Range | No practical lower or upper limit |
| Typical Measurement Time | 3–5 minutes per analysis |
| Molecular Weight Range | 980 Da – 20 MDa |
| Brand | Malvern Panalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model Options | Blue Label and Red Label configurations |
| Particle Size Range | 0.3 nm – 10 µm |
| Size Measurement Repeatability | ±2% |
| Temperature Control Range | 10–35 °C |
| Temperature Stability | ±0.1 °C |
| Detection Principle | Non-Invasive Back Scatter (NIBS) Dynamic Light Scattering (DLS) |
| Minimum Sample Volume | 12 µL |
| Sample Concentration Range | 0.1 mg/mL – 40% w/v |
| Zeta Potential Range | No practical lower or upper limit under standard operational conditions |
| Typical Measurement Time | 3–5 minutes per analysis |
| Molecular Weight Range | 980 Da – 20 MDa |
| Brand | Malvern PANalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model Variants | Blue Label and Red Label |
| Particle Size Range | 0.3 nm – 15 µm |
| Size Measurement Repeatability | ±2% |
| Temperature Control Range | 10–35 °C |
| Temperature Stability | ±0.1 °C |
| Detection Method | Non-Invasive Back Scatter (NIBS) DLS and Multi-Angle Dynamic Light Scattering (MADLS®) |
| Minimum Sample Volume | 3 µL |
| Sample Concentration Range | 0.1 mg/mL – 40% w/v |
| Zeta Potential Range | No practical lower or upper limit |
| Typical Measurement Time | 3–5 minutes |
| Molecular Weight Range | 980 Da – 20 MDa |
| Brand | Malvern PANalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | NanoSight Pro |
| Price | Upon Request |
| Particle Size Range | 10 nm – 1000 nm |
| Temperature Control Range | 5°C below ambient to 70°C |
| Measurement Principle | Nanoparticle Tracking Analysis (NTA) |
| Sample Concentration Range | 1×10⁶ – 1×10⁹ particles/mL |
| Minimum Sample Volume | 250 µL |
| Laser Wavelengths | 405 nm (<70 mW), 488 nm (<55 mW), 532 nm (<60 mW), 642 nm (<50 mW) |
| Detection Camera | High-sensitivity sCMOS (USB 3.0) |
| Compliance | Class 1 Laser Product (BS EN 60825-1:2014), EMC Directive (EN IEC 61326-1:2021), Low Voltage Directive (IEC 61010-1:2010 + AMD1:2016) |
| Dimensions (W×D×H) | 34 × 35 × 25 cm |
| Weight | 11 kg (instrument), 1.6 kg (laser module) |
| Power Supply | AC 110–240 V, 50–60 Hz, 4.0 A |
| Operating Environment | ≤80% RH at 31°C, linearly decreasing to 50% RH at 40°C |
| Brand | Malvern Panalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Zetasizer Sample Assistant |
| Pricing | Available Upon Request |