Empowering Scientific Discovery

Malvern Panalytical

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern Panalytical
OriginUSA
ManufacturerMicromeritics Instrument Corp.
ModelASAP 2460 Series
Analysis Stations2–6 (modular expansion)
Measurement PrincipleStatic gas adsorption (volumetric method)
Pore Size Range0.35–500 nm
Pressure Range0–1000 mmHg (absolute)
Theoretical BasisBET, t-plot, Langmuir, DFT, NLDFT, BJH, HK, SF
Optional ConfigurationsLow-surface-area (Kr adsorption, 10 mmHg transducer) and micropore (1 mmHg transducer, N₂/Ar/CO₂/H₂ capability)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern Panalytical
OriginUSA
ManufacturerMicromeritics Instrument Corp.
TypeSpecific Surface Area and Pore Size Analyzer
PrincipleStatic and Dynamic Gas Sorption
Number of Analysis Stations3
Micropore Range< 2 nm
Steam Adsorption CapabilityStandard
Chemisorption OptionsStatic, Dynamic (TPR/TPO/TPD/TPSR), Pulse
Temperature Control RangeUp to 1100 °C (±1 °C)
Pressure SensingUltra-low-range 0.1 Torr sensor for micropore analysis
Vacuum PerformanceMetal-sealed manifold with ultra-low outgassing rate
SoftwareMicroActive™ Data Reduction Suite
ComplianceASTM D3663, ISO 9277, ISO 15901, USP <846>, IUPAC Recommendations
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern Panalytical
OriginUSA
ManufacturerMicromeritics Instrument Corp.
ModelAutoChem III
Gas Inlet Ports18
Temperature RangeAmbient to 1200 °C
Ramp RateUp to 100 °C/min from –100 °C to 800 °C
Core FunctionsPulse Chemisorption, Temperature-Programmed Reduction (TPR), Single-Point BET Surface Area Analysis
ComplianceDesigned for GLP/GMP environments with audit-trail-ready software architecture
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern Panalytical
OriginUSA
ManufacturerMicromeritics Instrument Corp.
ModelMicromeritics ChemiSorb Auto
Instrument TypeChemisorption Analyzer
Measurement PrincipleFlow Method
Number of Gas Inlets8 (4 Carrier + 4 Loop)
Maximum Heating Temperature1000 °C
Programmable Heating Rate1–50 °C/min (with CryoCooler option enabling -100 °C to 1000 °C range)
Supported TechniquesTemperature-Programmed Reduction (TPR), Temperature-Programmed Oxidation (TPO), Temperature-Programmed Desorption (TPD), Pulse Chemisorption, TPSR, Strong Metal-Support Interaction (SMSI) analysis, Acid Site Strength Distribution (Lewis/Brønsted), BET Surface Area
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMalvern Panalytical
OriginUSA
ManufacturerMicromeritics Instrument Corporation
Instrument TypeSpecific Surface Area and Pore Size Analyzer
Number of Analysis Stations1–3
Gas OptionsN₂, Kr, Ar, CO₂, CH₄, C₄H₁₀ (non-corrosive)
Minimum Surface Area (N₂)0.01 m²/g
Minimum Surface Area (Kr)0.001 m²/g
Minimum Pore Volume4 × 10⁻⁶ cm³/g
Dewar Capacity2.75 L (optional 4 L)
Continuous Analysis Durationup to 40 h
Data Points per Isothermup to 1000
P₀ Measurementintegrated, continuous or manual input
Free Space Determinationmeasured, calculated, or user-defined
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0