Mass Spectrometry Instruments
Filter
Showing 421–450 of 765 results
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OmniStar® GSD 350 / ThermoStar® GSD 350 |
| Mass Range | 1–100 amu / 1–200 amu / 1–300 amu |
| Inlet Capillary | Stainless Steel (OmniStar®) or Quartz (ThermoStar®) |
| Max Capillary Temp | 350 °C |
| Sample Pressure | up to 1000 hPa (mbar) |
| Gas Flow Rate | 1–2 sccm |
| Detection Limit (C-SEM) | < 100 ppb |
| Resolution (10% valley) | Adjustable 0.5–2.5 amu |
| Dwell Time | 1 ms–16 s/amu |
| Mass Peak Separation (e.g., m/z 40/41) | < 10 ppm / < 20 ppm / < 50 ppm |
| Detector | C-SEM and Faraday |
| Analyzer | PrismaPro® Quadrupole Mass Filter |
| Dimensions (L×W×H) | 615 × 358 × 274 mm |
| Weight | 23 kg |
| Software | PV MassSpec |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | OMNISTAR™ / THERMOSTAR™ |
| Pricing | Upon Request |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | ThermoStar GSD301 |
| Detection Principle | Quadrupole Mass Spectrometry (QMS) |
| Mass Range | 1–300 u (standard), upgradable to 500 u |
| Detection Limit | <10⁻¹⁴ mbar (partial pressure, typical) |
| Ion Source | Gas-tight dual-filament design |
| Inlet System | Integrated Pt-capillary inlet, max. temp. 350 °C, vacuum-rated to 5×10⁻³ mbar |
| Pumping System | Dual-stage turbomolecular pumping (HiPace 80 + backing pump) |
| Software | QuadStar™ v4.x (supports ASTM E2554, ISO 11348, GLP-compliant audit trail, 21 CFR Part 11 optional modules) |
| Interface Compatibility | Fully compatible with TA Instruments, Mettler Toledo, NETZSCH, SETARAM, PerkinElmer, LINSEIS, Seiko, Micromeritics, Quantachrome TGA/DTA/DSC/adsorption systems |
| Brand | ULVAC-PHI |
|---|---|
| Origin | Japan |
| Model | PHI ADEPT-1010 |
| Instrument Type | Quadrupole |
| Primary Beam Energy Range | 0.25–11 keV |
| Mass Range | 1–340 amu |
| Distribution Status | Authorized Distributor (Imported) |
| Brand | PHI |
|---|---|
| Origin | Japan |
| Model | oTOF 3 |
| Instrument Type | Time-of-Flight (TOF) |
| Primary Beam Energy | 30 kV |
| Mass Range | 15,000 u |
| Mass Resolution | 13,500 |
| Configuration | Parallel Imaging MS/MS |
| Charge Neutralization | Dual-beam (low-energy electrons + low-energy inert gas ions), self-regulating, position-resolved |
| Optional Features | Dual-cluster ion source, sub-500 nm HR2 chemical imaging, DE-free acquisition mode, high beam current HR2 imaging, large angular acceptance & depth of field |
| Brand | PHI (Physical Electronics) |
|---|---|
| Model | TRIFT™ |
| Origin | Japan |
| Instrument Type | Time-of-Flight Secondary Ion Mass Spectrometry (TOF-SIMS) |
| Mass Analyzer | Triple-Focusing Reflectron TOF |
| Spatial Resolution | ≤ 100 nm (typical, dependent on primary ion source and sample conditions) |
| Imaging Modes | 256 × 256, 512 × 512, 1024 × 1024 pixel formats |
| Depth Profiling | Sputter-driven sequential layer removal with synchronized mass spectral acquisition |
| 3D Reconstruction | Voxel-based data integration from depth-resolved imaging stacks |
| Sample Stage Temperature Range | –150 °C to +200 °C (LN₂ cooling + resistive heating) |
| Sample Mounting Options | Back-mount (25 mm diameter), front-mount (100 mm × 100 mm planar support) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | ISOTOPX |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Phoenix |
| Instrument Type | Thermal Ionization Mass Spectrometer (TIMS) |
| Resolution | >450 |
| Dynamic Range (ATONA Amplifier) | 100 V |
| Mass Drift | <20 ppm over 40 min |
| Faraday Cup Lifetime | ≥10 years (Phoenix X62) |
| Vacuum Pumping Speed | Highest among commercial TIMS systems |
| Sample Capacity | 20-position rotatable carousel orthogonal to ion beam axis |
| Optional Detectors | Daly detector, Secondary Electron Multiplier (SEM), Multi-Collector Ion Counter with Conversion Dynode technology |
| Optional WARP Retarding Field Filter | Enables abundance sensitivity <1×10⁻⁸ for ²³⁷U/²³⁸U |
| Ion Extraction Slit | Enlarged for enhanced sensitivity |
| Focal Plane Rotation | Motorized, orthogonal to ion trajectory |
| Sample Chamber | Stainless steel with multiple auxiliary ports (pre-heating, cryo-trap, oxygen inlet) |
| Software | Fully integrated, GLP-compliant, remote operation enabled |
| Regulatory Compliance | Designed to support 21 CFR Part 11 audit trails, ISO/IEC 17025 data integrity requirements, and ASTM D7938 (TIMS-based isotope ratio analysis) |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Velocitas VMI |
| Pricing | Available Upon Request |
| Brand | Phytronix |
|---|---|
| Origin | Canada |
| Model | LDTD, Luxon |
| Instrument Type | Ion Source |
| Sample Introduction Speed | ≤6 s (LDTD), ≤1 s (Luxon), 0.6 s (Luxon-1536) |
| Ionization Mode | Atmospheric Pressure Chemical Ionization (APCI) via Laser-Induced Thermal Desorption |
| Compatibility | Triple Quadrupole (QqQ), Ion Trap, TOF, Q-TOF, Orbitrap, and Hybrid MS Platforms (SCIEX, Thermo Fisher, Shimadzu, Waters) |
| Sample Format | 96-well, 384-well, 1536-well plates (barcoded LazWell™ plates) |
| Carrier Gas | Zero-air (≤3 ppm H₂O) or dried air with VOC scrubber |
| Laser Source | Infrared laser diode array, 20 W max output, power ramp 0–45% in 3 s, hold at 45% for ~2 s, then rapid decay to 0% |
| Sample Volume | 0.5–10 µL (depending on plate format) |
| Residual Carryover | None (no memory effect) |
| Regulatory Compliance | Fully compatible with GLP/GMP workflows |
| Environmental Impact | Solvent-free, column-free, pump-free operation — eliminates LC consumables (mobile phases, columns, tubing, vials, filters) |
| Brand | Picarro |
|---|---|
| Origin | USA |
| Model | G2121-i |
| Measurement Principle | Cavity Ring-Down Spectroscopy (CRDS) |
| Target Analyte | δ¹³C in CO₂ |
| Precision (5-min avg) | ≤0.4‰ (typical 0.2–0.3‰) |
| CO₂ Concentration Range | 2000–4000 ppm |
| Measurement Interval | ~10 s |
| Operating Temperature | 10–35 °C |
| Sample Pressure | 300–1000 Torr (40–133 kPa) |
| Sample Flow Rate | <0.1 slm at 760 Torr |
| Sample Humidity | <99% RH, non-condensing at 40 °C |
| Dimensions (Analyzer) | 43.2 × 17.8 × 44.6 cm (W×H×D) |
| Weight | 27.4 kg (incl. external pump) |
| Power | 90–220 V AC, 50/60 Hz, <300 W |
| Brand | Picarro |
|---|---|
| Origin | USA |
| Model | G2131-i |
| Measurement Principle | Cavity Ring-Down Spectroscopy (CRDS) |
| δ¹³C Precision (1σ, 1-hr average) | < 0.1‰ (CO₂ > 380 ppm) |
| CO₂ Concentration Precision (30 s, 1σ) | 200 ppb (¹²C), 10 ppb (¹³C) |
| CH₄ Concentration Precision (30 s, 1σ) | 50 ppb + 0.05% of reading |
| H₂O Concentration Precision (30 s, 1σ) | 100 ppm |
| CO₂ Dynamic Range (precision-guaranteed) | 380–2000 ppm |
| CH₄ Dynamic Range (precision-guaranteed) | 0–500 ppm |
| H₂O Dynamic Range (precision-guaranteed) | 0–2.4% |
| Temperature Stability | ±0.005 °C (cavity) |
| Pressure Stability | ±0.0002 atm (cavity) |
| Sample Flow Rate | < 50 sccm at 760 Torr |
| Sample Temperature Range | −10 to +45 °C |
| Sample Pressure Range | 300–1000 Torr (40–133 kPa) |
| Environmental Operating Temp | 10–35 °C |
| Power Requirement | 100–240 VAC, 47–63 Hz, < 260 W peak |
| Brand | Picarro |
|---|---|
| Origin | USA |
| Model | G2132-i |
| Measurement Principle | Cavity Ring-Down Spectroscopy (CRDS) |
| δ¹³C Precision (1σ, 1-hour average) | < 0.4‰ at [CH₄] > 10 ppm |
| δ¹³C Drift (24 h, 1-hr avg) | < 1.5‰ at [CH₄] = 10 ppm |
| CH₄ Concentration Precision (30 s, 1σ) | 1 ppb + 0.05% of ¹³CH₄ reading |
| CH₄ Dynamic Range | 1.8–1500 ppm (operational) |
| CO₂ Range | 100–4000 ppm |
| H₂O Range | 0–5% RH |
| Sample Temp. | –10 to 45 °C |
| Sample Pressure | 300–1000 Torr (40–133 kPa) |
| Flow Rate | ≤25 sccm (at 760 Torr) |
| Temperature Stability | ±0.005 °C |
| Pressure Stability | ±0.0002 atm |
| Environmental Operating Range | 10–35 °C, <99% RH (non-condensing) |
| Data Interfaces | RS-232, Ethernet, USB, analog (0–10 V) |
| Dimensions (Analyzer) | 43.2 × 17.8 × 44.6 cm |
| Weight | 27.4 kg (incl. external pump) |
| Brand | Picarro |
|---|---|
| Origin | USA |
| Model | G2201-i |
| Instrument Type | Stable Gas Isotope Ratio Analyzer |
| Measurement Precision | δ¹³C-CO₂ < 0.12‰ (1σ, 1 hr), δ¹³C-CO₂/δ¹³C-CH₄ dual-species mode < 0.16‰ (1σ, 1 hr) |
| Measured Species | CO₂, CH₄, H₂O |
| Operating Principle | Cavity Ring-Down Spectroscopy (CRDS) |
| Temperature Stability | ±0.005 °C (cavity) |
| Pressure Stability | ±0.0002 atm (cavity) |
| Sample Flow Rate | < 50 sccm (typ. 25 sccm at 760 Torr) |
| Dimensions | 43.2 × 17.8 × 44.6 cm (W×H×D) |
| Weight | 25.4 kg (incl. external pump) |
| Brand | Picarro |
|---|---|
| Origin | USA |
| Model | G2207-i |
| Instrument Type | Stable Isotope Ratio Mass Spectrometer (IRMS) – Gas-Phase |
| Measurement Principle | Cavity Ring-Down Spectroscopy (CRDS) |
| O₂ Concentration Precision | < 2 ppm (5-min avg, dry basis) |
| δ¹⁸O Precision | < 1‰ (5-min avg) |
| H₂O Precision | 5 ppm + 0.1% of reading |
| O₂ Range | 5–25% |
| Operating Pressure | 300–1000 Torr |
| Sample Flow Rate | 80–110 sccm @ 760 Torr |
| Cavity Temperature Stability | ±0.005 °C |
| Cavity Pressure Stability | ±0.0002 atm |
| Environmental Operating Temp | 10–35 °C |
| Compliance | MIL-STD-810F (shock/vibration), CE, RoHS |
| Brand | Picarro |
|---|---|
| Origin | USA |
| Model | G2210-i |
| Instrument Type | Cavity Ring-Down Spectroscopy (CRDS)-Based Stable Isotope Analyzer |
| Measurement Targets | δ¹³CH₄, CH₄, C₂H₆, CO₂, H₂O |
| Precision (1σ, 5-min avg) | δ¹³CH₄: 0.5–1.0 ‰ |
| CH₄ | <0.1 ppb |
| C₂H₆ | <1 ppb |
| CO₂ | <200 ppb |
| Dynamic Range | CH₄: 2–30 ppm |
| C₂H₆ | 0–100 ppm |
| CO₂ | 300–2000 ppm |
| Measurement Frequency | up to 1.5 Hz |
| Sample Flow | ~40 sccm |
| Cavity Volume | 35 mL |
| Temperature Control Stability | ±0.005 °C |
| Pressure Control Stability | ±0.0002 atm |
| Operating Ambient | 15–35 °C |
| Power | 100–240 VAC, 47–63 Hz, <375 W peak |
| Brand | Picarro |
|---|---|
| Origin | USA |
| Model | G5131-i |
| Instrument Type | Stable Gas Isotope Ratio Analyzer |
| Measurement Principle | Cavity Ring-Down Spectroscopy (CRDS) in Mid-Infrared |
| Precision (1σ, 10-min avg) | δ¹⁵N / δ¹⁵Nα / δ¹⁵Nβ ≤ 0.5‰, δ¹⁸O ≤ 0.7‰ |
| Concentration Range | 300–1500 ppb N₂O in air |
| Measurement Interval | < 10 s |
| Sample Flow Rate | < 30 sccm |
| Operating Temperature | −10 to 45 °C |
| Power Consumption | 210 W (steady-state) |
| Dimensions | 43 × 32 × 69 cm (W × H × D) |
| Weight | 40 kg |
| Brand | Picarro |
|---|---|
| Origin | USA |
| Model | L2130-i |
| Instrument Type | Cavity Ring-Down Spectroscopy (CRDS) Isotope Ratio Analyzer |
| Measurement Targets | δ¹⁸O and δD in H₂O |
| Precision (1σ, liquid water) | δ¹⁸O ≤ 0.025‰, δD ≤ 0.100‰ |
| 24-h Drift (liquid) | δ¹⁸O ≤ 0.200‰, δD ≤ 0.800‰ |
| Water Vapor Range | 1,000–50,000 ppm |
| Detection Technique | Off-axis Integrated Cavity Output Spectroscopy (OA-ICOS) |
| Operating Temperature | 10–35°C (liquid analysis), –10 to 45°C (vapor analysis) |
| Dimensions | 43.2 × 19.1 × 43.2 cm (W × H × D) |
| Weight | 20.4 kg |
| Power | 90–240 VAC, 50/60 Hz, <150 W (analyzer), +80 W (external pump) |
| Software | Pre-installed Picarro Analysis Suite on Windows 10 Pro |
| Brand | Picarro |
|---|---|
| Origin | USA |
| Model | L2140-i |
| Instrument Type | Stable Isotope Ratio Analyzer for δ¹⁸O, δ¹⁷O, δD and Δ¹⁷O |
| Measurement Principle | Cavity Ring-Down Spectroscopy (CRDS) |
| Precision (1σ, 1 hr avg) | Δ¹⁷O < 15 per meg (< 0.015‰) |
| Sample Forms | Ambient water vapor, evaporated liquid water, or direct liquid injection (via optional autosampler) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | 1124123/13213112 |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Linear Ion Trap |
| Application Field | General-Purpose |
| Mass Range | m/z 50–1000 |
| Sensitivity | 0.5 ng/mL (for standard test compound under defined LC-MS conditions) |
| Resolution | ≤0.5 Da (FWHM at m/z 500) |
| Dimensions | 33.3 × 23.5 × 14.6 cm |
| Weight | 8.5 kg |
| Battery Life | Up to 2 hours (integrated Li-ion power supply) |
| Vacuum System | Dual-stage non-continuous atmospheric pressure interface (DAPI) with built-in turbomolecular pump |
| Analysis Time | <3 minutes from sample introduction to report-ready output |
| Brand | EXPECLIN / Puju Medical |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Domestic Product Classification | Domestic |
| Model | PreMed 7000 |
| Pricing | Available Upon Request |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | EA-IRMS-SCAR |
| Pricing | Upon Request |
| 14C Measurement Precision | 1–1.5 pMC @ 10 min |
| Measured Isotopes | ¹³C, ¹⁴C, ¹⁵N |
| Resolution (Central Collector) | 80 |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | EA-SCAR 14CO₂ |
| Quotation | Upon Request |
| Measurement Precision | 1–1.5 pMC @ 10 min |
| Isotope Measured | ¹⁴C in CO₂ |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | Isotope5 CN |
| Measurement Range | δ¹³C, δ¹⁵N |
| Resolution | >75 at m/z 29 |
| Detection System | Triple Faraday Collector for C/N/H/S/O |
| Mass Analyzer | 14 cm radius, 90° magnetic sector with permanent high-stability magnet |
| Vacuum System | Integrated low-power turbomolecular pump |
| Power Consumption | 240 W (typical) |
| Dimensions | 70 cm (L) × 30 cm (W) × 47 cm (H) |
| Weight | 45 kg |
| Brand | East & West Analytical Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Model | PRO-MS 3600 |
| Detection Range | ppb to 100% (v/v) |
| Detection Principle | Quadrupole Mass Spectrometry |
| Response Time | < 1.5 s (typical for single-point analysis) |
| Ion Source | High-efficiency inertized electron ionization source |
| Quadrupole Material | Passivated stainless steel |
| Inlet System | Multi-stage differential pumping with low-dead-volume valving |
| Software | Real-time spectral acquisition and quantitative analysis suite compliant with GLP data integrity requirements |
| Brand | Protea |
|---|---|
| Origin | United Kingdom |
| Model | ProMass |
| Form Factor | Semi-portable (carrying case or 6U 19″ rack-mount) |
| Detection Principle | Quadrupole Mass Spectrometry (QMS) |
| Mass Range | Adjustable (typical range 1–100 u or 1–300 u, configurable per application) |
| Detection Limit | Sub-ppb to low-ppb level (dependent on gas species and integration time) |
| Response Time | < 100 ms for single-ion monitoring |
| Ion Source | Electron Impact (EI), 70 eV standard |
| Detector | Dual-mode — Faraday Cup + Secondary Electron Multiplier (SEM) |
| Vacuum System | Integrated turbomolecular pump with backing pump |
| Compliance | CE-marked, RoHS-compliant, designed for industrial environments per IEC 61000-6-2/6-4 |
| Brand | Protea |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | ProMass-D |
| Pricing | Available Upon Request |
| Mass Range Options | 0–100 amu, 0–200 amu, or 0–300 amu (configurable) |
| Detection Principle | Quadrupole Mass Filtering (QMS) |
| Ion Detection | Dual-mode—Faraday Cup + Secondary Electron Multiplier (SEM) |
| Sample Inlet | Direct Capillary Inlet |
| Response Time | Millisecond-scale |
| Application Domain | Real-time Gas Phase Analysis in Lab and Process Environments |
| Brand | Protea |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | ProMass-T |
| Pricing | Available Upon Request |
| Brand | ASPEC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nimbus |
| Instrument Type | Electrospray Ionization (ESI) Source |
| Compatibility | Thermo and SCIEX LC-MS Systems |
| Operating Mode | Standalone (No External PC or Software Required) |
| Key Technology | Integrated eFrit Nanospray Emitters, Dual-Column Switching, On-Chip Column Heating & Temperature Control, Active Spray Tip Purging with Sheath Nitrogen Gas |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | PT-P5 |
| Instrument Type | Portable |
| Pricing | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Mini β |
| Pricing | Available Upon Request |