Mass Spectrometry Instruments
Filter
Showing 481–510 of 765 results
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | TripleTOF® 5600+ |
| Mass Analyzer Type | Time-of-Flight (TOF) with Quadrupole Precursor Selection |
| Ion Source | Turbo V™ Electrospray Ionization (ESI) / Atmospheric Pressure Chemical Ionization (APCI) |
| Additional Separation Technology | SelexION® Differential Ion Mobility Spectrometry (DIMS) |
| Data Acquisition Mode | SWATH® Acquisition (Data-Independent Acquisition, DIA) |
| Regulatory Compliance | Designed for 21 CFR Part 11–compliant environments |
| Application Focus | Quantitative and Qualitative LC-MS/MS in Drug Discovery, Proteomics, Metabolomics, and Impurity Profiling |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | TripleTOF® 6600 |
| Instrument Type | Quadrupole Time-of-Flight (QTOF) Mass Spectrometer |
| Ion Source | Turbo V™ Electrospray Ionization (ESI) / Atmospheric Pressure Chemical Ionization (APCI) |
| Additional Technology | SelexION® Differential Ion Mobility Spectrometry (DIMS) |
| Data Acquisition Mode | SWATH® Acquisition (Data-Independent Acquisition, DIA) |
| LC Compatibility | Analytical-, Micro-, Nano-flow LC and Capillary Electrophoresis–Electrospray Ionization (CESI) |
| Brand | SCIEX |
|---|---|
| Origin | Singapore |
| Model | TripleTOF® 6600+ LC-MS/MS System |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Category | Liquid Chromatography Tandem Mass Spectrometry System |
| Compliance | Designed for GLP/GMP, FDA 21 CFR Part 11–ready workflows |
| Software Platform | Analyst® TF 1.8 with SWATH® Acquisition support |
| Ion Source Flexibility | OptiFlow® Pro Micro/Nano ESI and SelexION® Differential Mobility Separation (DMS) compatible |
| Data Acquisition Mode | Data-Independent Acquisition (DIA) via SWATH® technology |
| Architecture | High-stability TOF ion optics with segmented ion entrance lens and windowed ionization control |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | TripleTOF™ 6600+ System |
| Category | Hybrid Quadrupole-Time-of-Flight Mass Spectrometer (Q-TOF MS) |
| Configuration | LC-MS/MS Platform for High-Resolution Accurate-Mass (HRAM) Analysis |
| Intended Use | Discovery and Quantitative Proteomics, Metabolomics, Lipidomics, and Small-Molecule Applications |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | X500B |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Configuration | Liquid Chromatography-Mass Spectrometry (LC-MS) Platform |
| Intended Use | Biopharmaceutical Characterization and Peptide Mapping |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | X500B QTOF System |
| Application Domain | Biopharmaceutical Characterization |
| Regulatory Status | Research-Use-Only (RUO), Not FDA-Cleared or CE-IVD Certified |
| Instrument Type | Quadrupole Time-of-Flight Liquid Chromatography Mass Spectrometer (LC-QTOF) |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | X500R QTOF |
| Instrument Type | Quadrupole-Time-of-Flight (QTOF) |
| Configuration | LC-MS/MS Platform |
| Ion Source | Turbo V™ Ion Source (N-type ion path architecture) |
| Mass Accuracy | < 2 ppm (internal calibration), < 3 ppm (external calibration, over 24 h) |
| Resolution | ≥ 35,000 FWHM (at m/z 622) |
| Mass Range | m/z 5–2,000 |
| Dynamic Range | > 5 orders of magnitude (linear) |
| Acquisition Modes | IDA, MRMHR, SWATH® Acquisition, MSᴱ, Full Scan + MS/MS |
| Software | SCIEX OS v2.4 or later |
| Compliance | Designed for GLP/GMP environments |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | X500R QTOF System |
| Application Domain | General-purpose LC-MS/MS Analysis |
| Compliance | Not registered as medical device in China |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SCIEX ZenoTOF 7600+ System |
| Instrument Type | Hybrid Quadrupole-Time-of-Flight (Q-TOF) Mass Spectrometer |
| Application Scope | Broad-spectrum Proteomics, Biomarker Discovery, Translational Research, Clinical Assay Development |
| Acquisition Mode | ZT Scan DIA (Data-Independent Acquisition with Quadrupole Dimensionality), DDA, Targeted MS/MS |
| Scan Speed | Up to 640 Hz |
| Fragmentation Technology | Electron-Activated Dissociation (EAD) |
| Mass Accuracy | < 2 ppm (internal calibration), < 3 ppm (external calibration) |
| Mass Resolution | > 35,000 FWHM (at m/z 200) |
| Dynamic Range | > 4 orders of magnitude |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | SCIEX ZenoTOF 8600 System |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) Mass Spectrometer |
| Application Scope | Universal (Small Molecules to Intact Proteins) |
| Ion Source | OptiFlow Pro Turbo Ionization Source |
| Mass Analysis Technology | Zeno™ Trap-Enhanced TOF with High-Frequency Pulsed Injection |
| Max MS/MS Scan Rate | 858 Hz (dependent on mass range and acquisition mode) |
| Quadrupole Scanning Speed | up to 4000 Da/s |
| Fragmentation Modes | CID, EAD (Electron-Activated Dissociation) up to 50 eV in both positive and negative ion modes |
| Vacuum System | Oil-Free Dry Pumping |
| Software Platform | SCIEX OS 4.0 with Real-Time Performance Monitoring, Health Diagnostics & Auto-Tuning |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SCIEX ZenoTOF® 7600 System |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) Mass Spectrometer |
| Application Scope | Universal |
| Mass Range | >40,000 Da |
| Sensitivity Enhancement | 5–20× vs. prior-generation Q-TOF |
| Resolution | >42,000 (FWHM at m/z 1,222) |
| Mass Accuracy | <1 ppm (external calibration) |
| Pressure Range | 0–1024 bar (HPLC/UHPLC compatible) |
| Brand | SCION |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Gas Chromatography Interface |
| Mass Range | 1–1200 m/z |
| Resolution | 0.7–4 amu (full width at half maximum, FWHM) |
| Detection Limit (IDL) | <1 fg (octafluoronaphthalene, OFN) |
| Scan Speed | ≥14,000 amu/sec |
| Oven Ramp Rate | ≥125 °C/min |
| Pressure Control Accuracy | ±0.001 psi |
| Ion Source | High-Temperature Inert Dual-Filament Electron Ionization Source |
| Pre-filter | Dual-Axis Pre-quadrupole |
| Detector | Long-Life Extended-Dynamic-Range Electron Multiplier |
| Vacuum System | High-Capacity Turbomolecular Pump (≥300 L/s N₂) |
| Flow Control | Digital Electronic Flow Control (EFC) on All Inlets and Detectors |
| Brand | SCION |
|---|---|
| Origin | Netherlands |
| Manufacturer | SCION Instruments |
| Instrument Type | Single Quadrupole GC-MS |
| GC Platform Options | SCION 8300 / 8500 |
| Mass Range | 1–1200 Da |
| Resolution | 0.7–4 Da (FWHM) |
| Sensitivity (EI Full Scan) | ≥1500:1 S/N for 1 pg Octafluoronaphthalene |
| Scan Speed | 20,000 Da/s |
| Oven Ramp Rate | Up to 180 °C/min |
| Pressure Control Accuracy | ±0.001 psi |
| Ion Source | Axially Oriented, Ultra-Inert Design |
| Vacuum System | High-Capacity Turbo-Molecular Pump (Standard) |
| Brand | SCION |
|---|---|
| Origin | Netherlands |
| Manufacturer | SCION Instruments (a part of Antec Scientific Group) |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary GC-Coupled |
| Mass Range | 1–1200 Da |
| Resolution | 0.7–4.0 Da (full width at half maximum, FWHM) |
| Sensitivity | ≥1500:1 S/N for 1 pg Octafluoronaphthalene (OFN) at m/z 272 |
| Scan Speed | 30,000 Da/s |
| Oven Ramp Rate | Up to 180 °C/min |
| Pressure Control Precision | ±0.001 psi |
| Brand | SDL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Domestic |
| Model | MODEL 3080GC-MS |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Gas Chromatograph |
| Mass Range | 41–300 AMU |
| Scan Speed | 1000 AMU/s |
| Detector | Quadrupole Mass Analyzer |
| Pressure Control Accuracy | Not Specified |
| Resolution | Not Specified |
| Sensitivity | Not Specified |
| Mass Accuracy | Not Specified |
| Oven Ramp Rate | Not Specified |
| Brand | Shandong Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional GC-MS |
| Mass Range | 1–1000 amu |
| Resolution (Full Width at Half Maximum) | 1000–2000 |
| Sensitivity (Signal-to-Noise Ratio) | >300:1 (at m/z 69, per 1 pg octafluoronaphthalene) |
| Scan Speed | 15,000 u/s |
| Oven Ramp Rate | ≥125 °C/min |
| Pressure Control Accuracy | ±0.001 psi |
| Temperature Control Accuracy | ±0.01 °C |
| Max Oven Temperature | 450 °C |
| Cooling Rate | 3.5 min (300 °C → 100 °C at 25 °C ambient) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 5D Ultra-e |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Chromatography Configuration | Comprehensive Two-Dimensional Gas Chromatography (GC×GC) Coupled with Online Liquid Chromatography (LC) |
| Mass Range | m/z 2–1090 |
| Resolution | Unit Mass Resolution |
| Sensitivity | >15,000:1 (S/N, peak-to-peak, at 1 pg OFN) |
| Scan Speed | 20,000 u/s |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer | Shimadzu Corporation |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Gas Chromatography-Mass Spectrometry (GC-MS) |
| Mass Range | m/z 1.5–1090 |
| Resolution | 0.4–2.0 u (FWHM) |
| Scan Speed | 20,000 u/sec |
| Mass Accuracy | ±0.1 u over 48 h |
| Oven Ramp Rate | Up to 250 °C/min |
| Detector | Electron Multiplier Mass Spectrometer |
| Pressure Control Precision | 0–150 psi |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer | Shimadzu Corporation |
| Product Origin | Imported |
| Model | GCMS NX Series |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Chromatography Type | Conventional GC-MS |
| Mass Range | 1–1000 u |
| Resolution | 1000–2000 (FWHM) |
| Sensitivity | >15,000:1 (S/N, using chlorobenzene, m/z 91) |
| Scan Speed | 20,000 u/s |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Instrument Type | Ion Trap Mass Spectrometer |
| GC Configuration | Conventional Capillary GC-MS |
| Mass Range | 1–1000 u |
| Resolution | 1000–2000 (FWHM at m/z 502) |
| Sensitivity | >300:1 (S/N, octafluoronaphthalene, full scan, 1 pg injected) |
| Scan Speed | 15,000 u/s |
| Detector | Electron Ionization (EI) Source, Dual-Entry Differential Turbo Pumping System |
| Data System | GCMSsolution v2.7x (Chinese localized version, compatible with GLP-compliant audit trail when configured per regulatory settings) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | QP2010SE |
| Instrument Type | Quadrupole GC-MS (not Orbitrap) |
| GC Type | Conventional Capillary GC-MS |
| Mass Range | m/z 1–1000 |
| Resolution | 1000–2000 (unit mass resolution at peak top) |
| Sensitivity | >300:1 (S/N, full-scan, 1 pg OFN) |
| Scan Speed | 15,000 u/s |
| Column Flow Capacity | Up to 4 mL/min He or N₂ |
| Ionization Mode | EI (electron ionization), optional CI |
| Detector | Electron multiplier |
| Data System | GCMSsolution v2.x or later |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | GCMS-QP2020 NX |
| Price Range | USD 110,000 – 205,000 |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional GC-MS |
| Mass Range | 1.5–1090 u |
| Resolution | Unit Mass Resolution |
| Sensitivity | >2000:1 (S/N, 1 pg OFN, m/z 272) |
| Scan Speed | 20,000 u/sec |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer | Shimadzu Corporation |
| Instrument Type | Single Quadrupole GC-MS |
| GC Configuration | Conventional Capillary GC-MS |
| Mass Range | 1.5–1090 u |
| Resolution | Unit Mass Resolution |
| Scan Speed | 30,000 u/sec |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic Instrument |
| Model | GCMS-TQ8040 NX |
| Price Range | USD 210,000 – 280,000 |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary GC Coupling |
| Mass Range | m/z 2–1090 |
| Resolution | 0.4–3.0 Da (Full Width at Half Maximum, FWHM) |
| Sensitivity | >18,000:1 (Signal-to-Noise Ratio, S/N, for 1 pg OFN in MRM mode) |
| Scan Speed | Up to 20,000 u/s |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GCMS-TQ8040 NX |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Chromatography Mode | Conventional Gas Chromatography-Mass Spectrometry (GC-MS/MS) |
| Mass Range | 2–1090 u |
| Resolution | 1000–2000 (FWHM, at m/z 502) |
| Sensitivity | >18,000:1 (S/N, for 1 pg OFN in Scan mode) |
| Scan Speed | Up to 20,000 u/s |
| Ion Source | High-Efficiency EI/CI Dual-Mode Ion Source |
| Collision Cell | Optimized RF-only Quadrupole Collision Cell |
| Temperature Ramp Rate | Programmable up to 120 °C/min (oven-dependent) |
| Pressure Control Accuracy | ±0.01 psi (electronic pneumatic control) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported Instrument |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Gas Chromatograph Coupling |
| MRM Channel Capacity | Up to 32,768 per run |
| Ion Source | Patented High-Efficiency Ion Source |
| Collision Cell | Optimized RF-Only Collision Cell |
| Scan Modes | Simultaneous Scan and MRM Acquisition |
| Software Platform | GCMSsolution with Smart MRM Automation |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Authorization | Authorized Distributor |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Gas Chromatograph |
| Model | GCMS-TQ8040X |
| Regulatory Compliance | Designed for GLP/GMP and FDA 21 CFR Part 11–compliant laboratories |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported Instrument |
| Model | GCMS-TQ8040X |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary Gas Chromatograph |
| MRM Channel Capacity | Up to 32,768 per run |
| Ion Source | Patented High-Efficiency Ion Source |
| Collision Cell | Optimized RF-Only Quadrupole Collision Cell |
| Scan Modes | Simultaneous Scan and MRM Acquisition |
| Software Platform | GCMSsolution with Smart MRM Automation |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | GCMS-TQ8050 NX |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary Gas Chromatograph Coupling |
| Mass Range | 2–1090 m/z |
| Resolution | Unit Mass Resolution |
| Sensitivity | >20,000:1 (Signal-to-Noise Ratio, S/N, for 1 pg OFN in Scan Mode) |
| Scan Speed | 20,000 u/s |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported Instrument |
| Model | ICPMS-2030 Series |
| Instrument Type | Quadrupole Mass Spectrometer |
| Plasma Gas Consumption (Standard Mode) | 10 L/min |
| Plasma Gas Consumption (Eco Mode, Standby) | 5 L/min |
| Carrier Gas Purity Requirement | Standard Argon (99.95%) |
| Software Compliance | FDA 21 CFR Part 11, ERES, GLP/GMP Audit Trail Ready |
| LC-ICP-MS Compatibility | Yes |
| Collision Cell Technology | Integrated Quadrupole-Based Collision/Reaction Cell |
