| Brand | EXPEC (Puyu Technology) |
|---|---|
| Model | TRACE 8000 |
| Ionization Source | Custom Glow Discharge CI Source with Reagent Gas Switching (H₃O⁺, O₂⁺, NO⁺) |
| Mass Analyzer | Orthogonal Acceleration Time-of-Flight (oa-TOF) |
| Mass Resolution (FWHM) | >4,000 at m/z 100 |
| Mass Accuracy | <3 ppm RMS (calibrated) |
| Scan Speed | ≤100 µs per spectrum |
| Detection Limit | Sub-pptv (gas phase, H₃O⁺ mode, for selected VOCs) |
| Ion Transmission Efficiency | Enhanced via High-Voltage Ion Funnel and Electrostatic Lens Optics |
| Compliance | Designed to support GLP/GMP workflows with audit-trail-capable software architecture |
| Operating Environment | Ambient air sampling |
| Brand | ULVAC-PHI |
|---|---|
| Origin | Japan |
| Model | PHI oTOF3+ |
| Type | TOF-SIMS Instrument with TRIFT Analyzer |
| Ion Sources | Liquid Metal Ion Gun (Ga⁺), Optional Ar-GCIB, Cs⁺, O₂⁺ |
| Spatial Resolution | <50 nm (high-resolution mode), <500 nm (high-mass-resolving mode) |
| Automation | Fully Automated Sample Transfer & Unattended Multi-Sample Analysis |
| Charge Neutralization | Dual-Beam Electron/Ar⁺ Neutralization System |
| Optional Features | Parallel Imaging MS/MS, FIB Cross-Sectioning, Cryo-Stage, Detachable Glovebox Integration |
| Compliance | Designed for GLP/GMP environments |
| Brand | Unimicro Technologies |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | MSD-4500 / MSD-4600 |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| Mass Range | 50–1400 m/z |
| Sensitivity | 1 pg reserpine (S/N ≥ 10:1, full-scan mode) |
| Resolution | 0.5–0.7 m/z (FWHM) |
| Mass Accuracy | ±0.1 Da (external calibration, standard conditions) |
| Ionization | Integrated Electrospray Ionization (ESI) source |
| Vacuum System | Built-in turbomolecular pump and backing pump |
| Control PC | Embedded industrial-grade computer |
| Interface Compatibility | Direct injection, eHPLC, CE, o-LC, HPLC, Prep-HPLC, TLC |
| Flow Rate Compatibility | Nano- to micro-flow (50 nL/min – 1 mL/min) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ACQUITY QDa II Mass Detector |
| Price | Upon Request |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ACQUITY RDa Detector |
| Pricing | Available Upon Request |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Atmospheric Pressure Gas Chromatography (APGC) Ion Source |
| Instrument Type | Atmospheric Pressure Chemical Ionization (APCI)-style GC-compatible ion source for triple quadrupole, Q-TOF, and ion mobility–enabled mass spectrometers |
| Compatibility | Xevo TQ-S, Xevo G2-S QTof, SYNAPT G2-Si |
| Vacuum Requirement | None (operates at atmospheric pressure) |
| Switching Time | <2 minutes between UPLC and GC modes |
| Design Principle | Engineered Simplicity™ |
| Regulatory Alignment | Supports 21 CFR Part 11-compliant workflows via MassLynx™ and UNIFI™ software |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BioAccord LC-MS System |
| Quotation | Upon Request |
| Instrument Type | Time-of-Flight (TOF) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BioAccord LC-MS System with ACQUITY Premier |
| Instrument Type | Time-of-Flight (TOF) |
| Application Scope | General-Purpose |
| Software Platform | UNIFI Scientific Information System |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Model | DESI XS |
| Compatibility | SELECT SERIES Cyclic IMS, SYNAPT XS, Xevo G2-XS QTof |
| Ionization Principle | Desorption Electrospray Ionization (DESI) |
| Environmental Sealing | Partially Enclosed Housing |
| Integrated Imaging | Side-View Camera for Spray-Sample Alignment |
| Motion Control | Stepper-Motor Stage with S-Curve Acceleration Algorithm |
| Automation | Auto-shutoff for Solvent Gas & High Voltage |
| Software Integration | HDI™ Software for High-Resolution Mass Spectrometry Imaging |
| Regulatory Context | Designed for GLP/GMP-compliant imaging workflows |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Model | RADIAN ASAP |
| Ionization Principle | Atmospheric Pressure Solid Analysis Probe (ASAP) |
| Mass Analyzer | Single Quadrupole |
| Detection Mode | Full Scan / Selected Ion Monitoring (SIM) |
| Sample Introduction | Direct Solid & Liquid Analysis |
| Software Platform | LiveID, IonLynx, OpenLynx |
| Compliance Support | FDA 21 CFR Part 11 (audit trail, electronic signature), GLP/GMP-ready workflows |
| Dimensions | Compact benchtop footprint (< 60 cm width) |
| Typical Analysis Time | < 30 seconds per sample |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SELECT SERIES Cyclic IMS |
| Pricing | Upon Request |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | SELECT SERIES MRT |
| Mass Analyzer Type | Multi-Reflecting Time-of-Flight (MRT-TOF) |
| Instrument Class | High-Resolution Accurate-Mass (HRAM) LC-MS/MS System |
| Application Scope | Universal (Life Sciences, Clinical Research, Forensics, Materials Surface Analysis) |
| Pressure Range | Not Applicable (Vacuum-operated analyzer) |
| Ion Sources Supported | DESI XS, SELECT SERIES MALDI, Electrospray (ESI), APCI |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | SQD2 |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| Chromatography Compatibility | UPLC, HPLC, UPC², SFC, Prep-LC, Prep-SFC, ASAP Direct Analysis |
| Ionization Modes | ESI, APCI, UniSpray, ZSpray |
| Mass Range | 0–3000 m/z |
| Software Platform | MassLynx, OpenLynx Open Access, AutoPurification Integration |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SYNAPT XS |
| Instrument Type | Ion Mobility Mass Spectrometer |
| Application Scope | Universal |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Xevo CDMS |
| Pricing | Available Upon Request |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Model | Xevo G3 QTof |
| Application Scope | Universal LC-MS/MS Platform |
| Mass Range | Not specified in source data |
| Resolution | Not specified in source data |
| Mass Accuracy | Not specified in source data |
| Sensitivity | Not specified in source data |
| Pressure Range | Not specified in source data |
| Compliance Context | Designed for GLP/GMP-aligned laboratories |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Xevo MRT |
| Instrument Type | Time-of-Flight (TOF) |
| Application Scope | General-Purpose |
| Resolution | 100,000 FWHM at 100 Hz |
| Mass Accuracy | <500 ppb |
| m/z Range | Broad, consistent across full scan range |
| Analyzer Architecture | Multi-Reflecting Time-of-Flight (MRT) with 4-meter effective flight path and 8 reflections |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Model | Xevo TQ Absolute |
| Instrument Type | Triple Quadrupole (TQ) |
| Application Scope | Universal LC-MS/MS Quantitation |
| Mass Range | Not specified by manufacturer in public datasheets |
| Sensitivity | Up to 15× higher for challenging negative-ion-mode analytes vs. prior-generation TQ systems |
| Resolution | Unit mass resolution standard for SRM/MRM transitions |
| Mass Accuracy | Not specified (typical for QqQ: ±0.1–0.2 Da under routine conditions) |
| Operating Pressure Range | Vacuum system maintained at <1×10⁻⁶ mbar in analyzer region |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Model | Xevo TQ Absolute XR |
| Instrument Type | Tandem Quadrupole (Triple Quadrupole) |
| Application Scope | Universal LC-MS/MS Analysis |
| Mass Range | Not Specified by Manufacturer |
| Sensitivity | Not Specified by Manufacturer |
| Resolution | Not Specified by Manufacturer |
| Mass Accuracy | Not Specified by Manufacturer |
| Operating Pressure Range | Not Specified by Manufacturer |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Xevo TQ-GC |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Chromatography Type | Gas Chromatography (GC) |
| Ionization Modes | Electron Ionization (EI) and Chemical Ionization (CI) |
| Software Platform | TargetLynx™, Quanpedia™, IntelliStart™ |
| Compliance Framework | Designed for GLP/GMP environments |
| Detection Principle | Selected Reaction Monitoring (SRM) / Multiple Reaction Monitoring (MRM) in triple quadrupole configuration |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Tandem Quadrupole (Triple Quad) |
| Model | Xevo TQ-S cronos |
| Configuration | LC-MS/MS System |
| Detection Principle | Electrospray Ionization (ESI) / Atmospheric Pressure Chemical Ionization (APCI) coupled with tandem mass spectrometry in Multiple Reaction Monitoring (MRM) mode |
| MRM Transition Rate | Up to 555 transitions per second |
| Linear Dynamic Range | >5 orders of magnitude |
| Typical Precision | <4% RSD for challenging analytes with 5 ms dwell time |
| Regulatory Compliance Support | 21 CFR Part 11, GLP/GMP audit trails, ISO/IEC 17025-aligned workflows |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Tandem Quadrupole (QqQ) |
| Model | Xevo TQ-S micro |
| Ion Sources Compatibility | ESI, APCI, ESCi, UniSpray, APGC, ionKey/MS, ASAP, Nanoflow ESI |
| LC Compatibility | ACQUITY UPLC H-Class PLUS/Bio PLUS, I-Class PLUS, UPC2, M-Class |
| Key Technology | Z-Spray Ion Source, StepWave Off-Axis Ion Focusing |
| Regulatory Alignment | Compliant with SANTE/11813/2017, FDA 21 CFR Part 11 (via MassLynx software), GLP/GMP data integrity requirements |
| Brand | Waters |
|---|---|
| Origin | USA |
| Instrument Type | Tandem Quadrupole (QqQ) |
| Model | Xevo TQ-S |
| Ionization Flexibility | Universal Source Architecture |
| Key Technology | StepWave™ Ion Guide, T-Wave™ Collision Cell, RADAR™ Simultaneous Quant/Qual Mode |
| Software Suite | MassLynx™, TargetLynx™, QCMonitor™, IntelliStart™, Quanpedia™ |
| Regulatory Support | 21 CFR Part 11 compliant workflows, GLP/GMP-ready audit trails, ISO/IEC 17025-aligned data integrity framework |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Model | Xevo TQ-XS |
| Instrument Type | Tandem Quadrupole (Triple Quad) |
| Ionization Source Compatibility | UniSpray™, Electrospray Ionization (ESI), Atmospheric Pressure Chemical Ionization (APCI) |
| Detection Principle | Selected Reaction Monitoring (SRM) / Multiple Reaction Monitoring (MRM) |
| Dynamic Range | 6 orders of magnitude (Xtended Dynamic Range, XDR™) |
| Ion Transmission Technology | StepWave XS™ off-axis ion optics |
| Probe Design | Tool-free atmospheric pressure ionization (API) source |
| Software Platform | MassLynx™ NX, TargetLynx XS™, Intellistart™, QUANPEDIA™ |
| Regulatory Compliance Support | 21 CFR Part 11, GLP/GMP audit trails, electronic signatures |
| Brand | Waters |
|---|---|
| Origin | USA |
| Instrument Type | Tandem Quadrupole (QqQ) |
| Model | Xevo TQD |
| Ionization Flexibility | Universal Source Architecture Supporting ESI, APCI, ESCi, and Optional Atmospheric Pressure Photoionization (APPI) |
| Chromatographic Compatibility | Optimized for UPLC and HPLC Coupling |
| Data Acquisition Speed | High-speed MRM acquisition supporting sub-3-second UPLC peaks |
| Software Suite | MassLynx v4.2 with IntelliStart, Quanpedia, QCMonitor, TargetLynx, TrendPlot, and RADAR™ Mode |
| Regulatory Compliance Support | 21 CFR Part 11–compliant audit trails, electronic signatures, and GLP/GMP-ready workflow tools |
| Hardware Architecture | Robust RF-only quadrupole design with T-Wave collision cell for enhanced ion transmission and fragmentation efficiency |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer | WAYEAL Scientific Instrument Co., Ltd. |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary Gas Chromatograph |
| System Architecture | Integrated GC-MS Platform |
| Control Software | Unified GUI for Acquisition, Processing & Reporting |
| Compliance Framework | Designed to support GLP/GMP workflows and 21 CFR Part 11–ready audit trail functionality (configuration-dependent) |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | High-Capacity Direct-Pressure Helium Leak Detector |
| Pricing | Available Upon Request |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | High-Precision Differential Pressure Leak Tester |
| Pricing | Available Upon Request |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic (China) |
| Model | ZH600-X Multi-Station Hermeticity Leak Detector |
| Pricing | Available Upon Request |
| Pressure Sensor Range (ZH600-X) | 10–500 kPa (mechanically regulated) |
| Sensor Accuracy | ±0.1% FS |
| Display Resolution | Adjustable to 0–4 decimal places |
| Pressure Units | kPa, MPa, kg/cm², psi, mbar, bar, Torr, mmH₂O, mmHg |
| Leak Rate Units | Pa, kPa, Pa/s, kPa/s, kPa/min, mL/s, mL/min, mL/h, L/min, L/h, SCCM |
| Programmable Test Profiles | 64 total (16 per channel across A/B/C/D channels) |
| Test Cycle Time | 0–999 s (max test duration: 1800 s) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Required Test Gas Source | Clean, dry, ≥500 kPa supply pressure, ≥100 kPa above test pressure |
| Dimensions (ZH600-X) | 431 × 187 × 460 mm |
| Weight | ~14 kg |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | LC103(V5) / LC101(V6) Wide-Range Flow-Based Leak Detector |
| Price Range | USD 14,000 – 28,000 |
| Flow Range | 30–1000 mL/min (selectable) |
| Pressure Regulation | Mechanical, 10–600 kPa (selectable) |
| Test Pressure Units | kPa, MPa, kg/cm², psi, mbar, bar, Torr, mmH₂O, mmHg |
| Leak Rate Units | mL/s, mL/min, L/min, L/h, m³/h, Pa/min, g/h, SCCM |
| Display Resolution | Adjustable to 0–4 decimal places |
| Sensor Accuracy | ±3% F.S. (LC103 V5), ±0.1% F.S. (LC101 V6) |
| Programmable Test Profiles | 64 sets |
| Test Cycle Timing | 0–999 s |
| Max Test Duration | 1800 s |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Required Test Gas Source | Clean, dry, ≥500 kPa supply pressure, at least 100 kPa above test pressure |
| Dimensions (V5) | 330 × 222 × 448 mm |
| Dimensions (V6) | 321 × 205 × 460 mm |
| Weight | ~16 kg |