Mass Spectrometry Instruments
Filter
Showing 391–420 of 765 results
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 340 |
| Detection Principle | Helium-Specific Quadrupole Mass Spectrometry |
| Operating Mode | Vacuum (Sniffer & Vacuum Chamber) |
| Typical Sensitivity | ≤5 × 10⁻¹² mbar·L/s (He) |
| Pumping Configuration | Integrated with Duo 2.5 Dual-Stage Rotary Vane Pump |
| Compliance | CE, RoHS, ISO 9001 Manufacturing Environment |
| Software Interface | Pfeiffer Vacuum ControlSuite (PC-based, USB/Ethernet) |
| Data Logging | Timestamped leak rate records with user-defined pass/fail thresholds |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 340 (Thermal Pipe-Specific Configuration) |
| Detection Sensitivity | ≤1×10⁻⁸ mbar·L/s (He) |
| Operating Mode | Vacuum Test (Sniffer & Accumulation Compatible) |
| Pumping System | Integrated HiPace 80 Molecular Pump + ACP 20 Dry Scroll Backing Pump |
| Compliance | CE, RoHS, ISO 9001 Certified |
| Interface Options | Analog I/O, RS-232, Ethernet (Modbus TCP), Optional Footswitch Integration |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 340 |
| Application-Specific Configuration | Lithium Battery Hermeticity Testing System |
| Distribution Status | Authorized Distributor (Shanghai Bodo Vacuum Equipment Co., Ltd.) |
| Price Range | USD 13,500 – 40,500 (FOB Shanghai) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 340 |
| Detection Sensitivity | ≤1×10⁻¹² mbar·L/s (He) |
| Leak Rate Measurement Range | 1×10⁻¹² to 1×10⁻⁴ mbar·L/s |
| Vacuum Interface | DN 40 ISO-KF or CF |
| Mass Analyzer Type | Magnetic Sector Quadrupole |
| Response Time | <100 ms (typical) |
| Operating Temperature | 10–40 °C |
| Compliance | CE, RoHS, EN 61000-6-2/6-3, ISO 9001 certified manufacturing |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 340 (WET/D/I variants) |
| Minimum Detectable Leak Rate (He) | 5 × 10⁻¹³ Pa·m³/s (vacuum mode) |
| Detection Gases | ⁴He, ³He, H₂ |
| Inlet Pumping Speed | 2.5 L/s |
| Max Inlet Pressure | 25 hPa (WET/D), 5 hPa (I) |
| Pre-vacuum Requirements | Oil rotary pump (15 m³/h) or diaphragm pump (3.4 m³/h) |
| Weight | 56 kg (WET), 45 kg (D), 32 kg (I) |
| Detection Modes | Vacuum mode & sniffer (probe) mode |
| Compliance | Designed for ISO 20484, ASTM E1779, and GLP/GMP-aligned vacuum integrity verification workflows |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 340 |
| Detection Principle | Quadrupole Mass Spectrometry (He⁺ at m/z = 4) |
| Minimum Detectable Leak Rate (Vacuum Mode) | 5 × 10⁻¹³ Pa·m³/s |
| Operating Pressure Range (Analyzer) | 1 × 10⁻⁷ to 1 × 10⁻³ hPa |
| Mass Resolution | Unit mass resolution (FWHM ≤ 1 amu at m/z = 4) |
| Interface | DN 40 CF vacuum flange |
| Control | Touchscreen GUI with real-time leak rate display and trend logging |
| Compliance | Designed per ISO 20486:2017 (Leak detection — Vocabulary and test methods), compatible with ASTM E499-21 (Standard Test Method for Leak Detection Using Helium Mass Spectrometer) and EU Machinery Directive 2006/42/EC |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | ASM 340 |
| Instrument Type | Portable |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 5 × 10⁻¹³ Pa·m³/s |
| Startup Time | 3 min |
| Response Time | < 1 s |
| Maximum Inlet Pressure | 2500 Pa |
| Helium Purge Speed | 2.5 L/s |
| Leak Rate Display Range | 1 × 10⁻³ to 1 × 10⁻¹³ Pa·m³/s |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 340WET |
| Detection Principle | Helium-Specific Quadrupole Mass Spectrometry |
| Operating Mode | Vacuum (Hard-Line) Mode |
| Pumping Configuration | Integrated with ACP 28 Dry Scroll Vacuum Pump |
| Compliance | CE, RoHS, ISO 9001 Certified |
| Interface | RS-232 / Ethernet (Optional), Analog Output (0–10 V) |
| Minimum Detectable Leak Rate | ≤5 × 10⁻¹² mbar·L/s (He) |
| Response Time | < 0.5 s (typical) |
| Mass Filter | Quadrupole with 4 amu resolution at 4 He peak |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 390, ASM 392 |
| Detection Gas | 4He, 3He, H₂ |
| Minimum Detectable Leak Rate (Vacuum Mode) | 1×10⁻¹² mbar·L/s |
| Minimum Detectable Leak Rate (Sniffer Mode) | 1×10⁻⁸ mbar·L/s |
| Helium Pumping Speed | 10 L/s (ASM 390), 25 L/s (ASM 392) |
| Forepump Speed | 35 m³/h |
| Max Inlet Pressure | 20 mbar |
| Warm-up Time (Un-calibrated, 20°C) | 2 min |
| Inlet Port | DN 40 ISO-KF |
| Response Time | < 1 s |
| Interface Options | RS-232, Digital I/O, Ethernet |
| Noise Level | ≤ 55 dB(A) |
| Weight | 125 kg (ASM 390), 130 kg (ASM 392) |
| Dimensions (L×W×H) | 1072 × 455 × 1025 mm |
| Certifications | CE, ETL, UL 61010, SEMI S2 |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ASM Series |
| Price Range | USD 13,500 – 40,500 (FOB) |
| Detection Principle | Quadrupole Mass Spectrometry (4 amu He⁺ ion detection) |
| Minimum Detectable Leak Rate | ≤5×10⁻¹³ mbar·L/s (typical, with optimized calibration and turbomolecular pumping) |
| Pumping Configuration | Integrated turbomolecular pump + backing pump |
| Interface | RS232 / Ethernet / Optional Profibus/Modbus TCP |
| Compliance | CE, RoHS, ISO 9001 certified manufacturing |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM-2000 |
| Detection Principle | Helium Mass Spectrometry (Quadrupole) |
| Measurement Methods | Vacuum Mode & Sniffer Mode |
| Quantitative Sensitivity (Vacuum Mode) | 1×10⁻⁸ – 1×10⁻⁵ mbar·L/s |
| Qualitative Sensitivity (Sniffer Mode) | >1×10⁻⁵ mbar·L/s |
| Calibration | Automatic, traceable to NIST-certified standard leak |
| Operating Temperature | 15–25 °C |
| Relative Humidity | 30–80 % RH |
| Power Supply | 90–250 V AC, 50–60 Hz |
| Typical Power Consumption | 3,750 W |
| Compressed Air (ISO 8573-1 Class 1.3.1) | 4.5–10 bar(g) |
| Helium Supply Pressure | 0.5–8 bar(g) |
| Nitrogen Supply Pressure | 0.5–8 bar(g) |
| User Interface | 10" multi-touch full-HD color display |
| Software | GMP-compliant Windows 10 OS with 4-tier user access control, PDF report generation (test, calibration, audit trail), FDA 21 CFR Part 11 readiness |
| Connectivity | 1× LAN, 2× USB 3.0, 1× HDMI |
| Dimensions (L×W×H, incl. trolley) | 1,409 × 575 × 1,194 mm |
| Weight (incl. trolley) | 140 kg |
| Acoustic Noise Level | <53 dB(A) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ASM182 TD+ |
| Price Range | USD 13,500 – 40,500 |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM182 TD+ |
| Detection Principle | Helium-Specific Mass Spectrometry (m/z = 4) |
| Minimum Detectable Leak Rate | ≤5×10⁻⁸ mbar·L/s |
| Pumping Speed (Foreline) | ≥18 m³/h (with recommended backing pump) |
| Mass Analyzer Type | Magnetic Sector or Quadrupole (TD+ variant optimized for trace helium sensitivity) |
| Compliance | CE, RoHS, ISO 9001 certified manufacturing |
| Interface | RS-232, Ethernet, Analog I/O (0–10 V / 4–20 mA) |
| Operating Environment | 15–35 °C, <80% RH non-condensing |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM306S |
| Minimum Detectable Leak Rate (He) | 1×10⁻⁷ mbar·L/s |
| Minimum Detectable Leak Rate (H₂) | 5×10⁻⁷ mbar·L/s |
| Startup Time | 2 min |
| Response Time | < 1 s |
| Sniffer Probe Flow Rate | 300 sccm ± 10% |
| Noise Level | 55 dB(A) |
| Interfaces | RS-232, I/O, Fieldbus options (optional Ethernet) |
| Operating Temperature | 10–40 °C |
| Power Supply | 100–240 V, 50/60 Hz |
| Power Consumption | 300 VA |
| Weight | 22 kg |
| Dimensions (L×W×H) | 350 × 305 × 421 mm |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM310 |
| Minimum Detectable Leak Rate (Vacuum Mode) | 5×10⁻¹³ Pa·m³/s |
| Helium Pumping Speed | 1.1 L/s |
| Weight | 21 kg |
| Power Supply | Universal AC Input (100–240 V, 50/60 Hz) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM340 WET |
| Application | Sealed Component Leak Testing in Automotive HVAC Systems |
| Detection Principle | Helium Mass Spectrometry (180° Magnetic Sector Analyzer) |
| Operating Mode | Vacuum Chamber (Accumulation) & Vacuum-Mode (Sniffing-Compatible via External Pumping Interface) |
| Leak Rate Sensitivity | ≤5×10⁻¹² mbar·L/s (He, typical) |
| Pumping Interface | Integrated Dry Scroll Backing Pump + Turbomolecular Pump (WET Configuration) |
| Compliance | CE, RoHS, ISO 9001 Certified |
| Software | VacuGraph® PC-Based Control with Audit Trail, Data Export (CSV, XML), User Access Levels |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM340-W |
| Minimum Detectable Leak Rate (Vacuum Mode) | 5×10⁻¹³ Pa·m³/s |
| Detection Gases | ⁴He, ³He, H₂ |
| Inlet Pressure Range (Vacuum Mode) | Up to 25 hPa (operational at 100 hPa for gross leak screening) |
| Helium Pumping Speed | 2.5 L/s |
| Forepump Options | Oil-sealed rotary vane pump (Adixen Pascal 1015i, 15 m³/h) or dry diaphragm pump (ASM340-D variant) |
| Startup Time | ≤3 min |
| Compliance | CE, RoHS, ISO 9001-manufactured |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM340W |
| Detection Limit | < 5 × 10⁻¹³ Pa·m³/s |
| Leak Detection Method | Vacuum Mode (Bypass Connection) |
| Compliance | CE, RoHS, ISO 9001-certified Manufacturing |
| Interface | RS232, Ethernet, Analog Output (0–10 V) |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Operating Temperature | 10–40 °C |
| Weight | 28 kg |
| Dimensions (W × H × D) | 482 × 132 × 500 mm |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM340W + LP503 |
| Minimum Detectable Leak Rate (Vacuum Mode) | 5 × 10⁻¹³ Pa·m³/s |
| Detection Gases | ⁴He, ³He, H₂ |
| Detection Modes | Vacuum, Sniffer (Helium Absorption) |
| Helium Pumping Speed at Inlet | 2.5 L/s |
| Maximum Inlet Pressure | 25 hPa |
| Forepump Speed | 15 m³/h |
| Sniffer Probe | LP503 with LED Indication and 3 m Cable |
| Compliance | Designed for ISO 16000-8, ASTM E1778, and GLP/GMP-aligned leak integrity verification workflows |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | ASM340wet |
| Detection Principle | Helium-Specific Quadrupole Mass Spectrometry |
| Minimum Detectable Leak Rate | ≤5×10⁻¹³ Pa·m³/s |
| Operating Mode | Sniffer (Absorption) Mode |
| Integrated Vacuum Pump Type | Wet Rotary Vane Pump |
| Max. Suction Flow Rate | 2.5 L/s (at inlet) |
| Helium Partial Pressure Sensitivity | 1×10⁻¹³ A/Pa |
| Response Time (T₉₀) | <1.5 s |
| Compliance | CE, RoHS, ISO 9001 certified design |
| Interface | RS-232, Analog Output (0–10 V), Digital I/O for PLC Integration |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM390 |
| Minimum Detectable Leak Rate (Vacuum Mode) | 1×10⁻¹² mbar·L/s |
| Minimum Detectable Leak Rate (Sniffer Mode) | 1×10⁻⁸ mbar·L/s |
| Helium Pumping Speed | 10 L/s |
| Forepump Type | Dry, Non-Contact Scroll Pump |
| Forepump Speed | 35 m³/h |
| Detectable Gases | ⁴He, ³He, H₂ |
| Compliance | Designed for Semiconductor Industry Vacuum Integrity Requirements |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | OmniStar / ThermoStar |
| Principle | Quadrupole Mass Filter |
| Response Time | ≤2 s |
| Mass Range Options | 1–100 amu, 1–200 amu, 1–300 amu |
| Inlet Capillary Temperature | Up to 350 °C |
| Inlet Material | Stainless Steel (OmniStar) or Fused Silica (ThermoStar) |
| Pumping System | MVP dry diaphragm pump + HiPace turbomolecular pump |
| Software | PV MassSpec (qualitative & quantitative analysis) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | GSD 350 |
| Mass Range | 1–100 / 1–200 / 1–300 amu (selectable) |
| Inlet Type | Heated stainless-steel capillary (OmniStar®) or heated quartz capillary with Pt gasket (ThermoStar®) |
| Capillary Heating Temperature | Up to 350 °C |
| Gas Flow Rate | 1–2 sccm |
| Sample Pressure Range | ≤1000 hPa |
| Detection Limit (C-SEM) | <100 ppb |
| Resolution | 0.5–2.5 amu (at 10% peak height, adjustable) |
| Analysis Speed | Down to 1 ms/amu |
| Dimensions (L×W×H) | 615 × 358 × 274 mm |
| Weight | ~23 kg |
| Power Supply | 85–265 VAC |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | HiCube RGA |
| Mass Range | 1–300 u |
| Detection Modes | Faraday (F) and C-SEM/Faraday (M) |
| Minimum Detectable Pressure (M) | 3×10⁻¹⁵ hPa |
| Resolution | <10–50 ppm adjacent peak interference |
| Quadrupole Dimensions | 6 mm Ø × 125 mm |
| Operating Temperature (Analyzer) | ≤200 °C (≤150 °C with SEM) |
| Bakeout Temperature | 300 °C |
| Inlet Flange | DN 40 CF-F |
| Data Acquisition | Ethernet interface |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Weight | 25.5–26.2 kg |
| Turbo Pump | HiCube™ Eco (N₂ speed: 67 L/s |
| power | 170 W) |
| Forevacuum Pump | 1 m³/h at 50 Hz |
| Vacuum Gauge | PKR 361 (range: 1×10⁻⁹ – 1×10³ hPa) |
| Integrated Valve | EVN 116 (adjustable conductance: 5×10⁻⁶ – 3×10³ hPa·L/s) |
| Inlet Port | DN 16 ISO-KF |
| Dwell Time | 1 ms – 16 s/amu |
| Peak Ratio Reproducibility | ±0.5 % |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | HiQuad™ |
| Measurement Principle | Quadrupole mass spectrometry with electron ionization (EI), optimized for real-time, high-speed quantitative gas analysis in industrial process environments |
| Mass Range | 1–128 u, 1–300 u, or 1–512 u (configurable per QMA analyzer variant) |
| Minimum Detectable Partial Pressure | 5×10⁻¹⁶ mbar (QMA 410), 2×10⁻¹⁵ mbar (QMA 430), 1×10⁻¹⁵ mbar (Ar, QMA 400) |
| Sensitivity (Faraday, 1 mA emission) | 1×10⁻³ A/mbar (QMA 410), 2×10⁻⁴ A/mbar (QMA 430), 5×10⁻⁴ A/mbar (QMA 400) |
| Max. Operating Pressure (Faraday) | 1×10⁻⁴ mbar |
| Max. Operating Pressure (SEM) | 1×10⁻⁵ mbar |
| Isotopic Ratio Precision (e.g., ⁴⁰Ar/⁴¹Ar) | < 0.3 ppb SEM resolution |
| Analyzer Temperature | 150 °C (operational), 400 °C (bake-out) |
| Scan Speed | up to 125 µs per atomic mass unit |
| Long-Term Stability | < 0.1 % drift over 8 hours |
| Ion Source | Off-axis biased electron impact source with magnetic field enhancement for low background and high signal-to-noise ratio |
| Detector Options | Faraday cup and secondary electron multiplier (SEM) |
| Interface | Integrated OPC UA server and embedded web browser |
| Software | Quadera® platform for real-time data acquisition, matrix-based concentration calculation, and multi-channel calibration |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HPA 220 / SPM 220 |
| Pricing | Upon Request |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | MiniTest 300 |
| Weight | 5 kg |
| Minimum Detectable Leak Rate | 5 × 10⁻⁸ Pa·m³/s |
| Maximum Inlet Pressure | 200 hPa (abs.) |
| Operating Temperature | +10 °C to +35 °C |
| Storage Temperature | +10 °C to +55 °C |
| Acoustic Noise Level | < 70 dB(A) |
| Power Supply | 100–240 V, 50/60 Hz |
| Interface Options | RS-485, RJ-25, Gauge, I/O D-sub 9, Remote Control D-sub 9 |
| Wireless Remote Range | up to 100 m (RC 500 optional) |
| Sensor Technology | Quartz Window Mass Filter |
| Warm-up Time to Ready State | ≤ 30 min |
| Display | 3.5-inch LCD |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | GSD350 O1 |
| Mass Range | 1–100 amu |
| Maximum Inlet Pressure | 1200 hPa |
| Detection Limit | < 100 ppb |
| Gas Flow Rate | 1–2 sccm (0 °C) |
| Analog Inputs | 5 × (−10 to +10 V, 14/16 bit) |
| Capillary | Stainless Steel, 1 m |
| Inlet Heating Temperature | Up to 200 °C |
| Filament | Dual Iridium with Y₂O₃ coating |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | GSD350 O3 |
| Mass Range | 1–100 amu |
| Maximum Inlet Pressure | 1200 hPa |
| Detection Limit | < 100 ppb |
| Gas Flow Rate | 1–2 sccm (at 0 °C) |
| Analog Inputs | 5 × (−10 to +10 V), 14/16 bit |
| Capillary Material | Stainless Steel |
| Capillary Length | 1 m |
| Sample Inlet Heating Temperature | Up to 200 °C |
| Filament Type | Iridium, Dual Y₂O₃-coated |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | GSD350 |
| Detection Principle | Quadrupole Mass Spectrometry (QMS) |
| Mass Range | 1–300 u (standard configuration) |
| Detection Limit | < 10⁻¹⁴ mbar (partial pressure, typical) |
| Response Time | < 1 s (for 10–90% step change, with optimized inlet) |
| Operating Pressure Range | 10⁻⁵ – 10⁻³ mbar (ion source) |
| Interface Temperature | Up to 200 °C (heated capillary inlet) |
| Data Acquisition Rate | Up to 100 spectra/s (full scan) |
| Compliance | CE, RoHS, ISO 9001 certified manufacturing |