Mass Spectrometry Instruments
Filter
Showing 91–120 of 487 results
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (PRC) |
| Model | Anyeep Cassitrap 120K |
| Chromatography Type | Capillary GC-coupled |
| Mass Range | 1.5–1250 Da (Quadrupole Mode) |
| Resolution | >120,000 FWHM at m/z 131 (1.5 Hz acquisition rate) |
| Sensitivity | ≥1000:1 S/N for 100 fg octafluoronaphthalene (OFN), m/z 272 (quadrupole mode) |
| Scan Speed | 20,000 Da/s (quadrupole mode) |
| Mass Accuracy | ±0.1 Da (quadrupole mode) |
| Oven Ramp Rate | ≥120 °C/min (standard column oven) |
| Detector | Electron Multiplier (quadrupole mode only) |
| Pressure Control Precision | ±0.001 psi |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | LC Cassitrap 120K |
| Pricing | Upon Request |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | Mate11 |
| Instrument Type | Portable GC-MS |
| Mass Range | 1.5–550 amu |
| Dynamic Range | 7 orders of magnitude |
| Mass Resolution | Unit mass resolution |
| Maximum Scan Rate | 10,000 amu/s |
| Sensitivity | 1 pg octafluoronaphthalene (OFN), S/N = 150:1 (RMS) |
| Weight | < 20 kg |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | RGA 6500 |
| Pricing | Upon Request |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | SQ910 LC-MS |
| Pricing | Available Upon Request |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary Gas Chromatograph |
| Model | Anyeep TQ8100 |
| Compliance | Designed for GLP/GMP-aligned laboratories |
| Software | Integrated acquisition and quantitation platform with audit trail capability |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | TQ9100 |
| Instrument Type | Triple Quadrupole Mass Spectrometer (QqQ) |
| Application Scope | General-Purpose LC-MS/MS |
| Resolution | Unit Resolution (m/Δm ≈ 1,000 FWHM at m/z 500) |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Domestic Product Classification | China-Made Instrument |
| Model | TQ9120 LC-MS/MS |
| Pricing | Available Upon Request |
| Brand | Applied Spectra |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RESOchron SE/LR |
| Instrument Type | Rare Gas Isotope Ratio Mass Spectrometer |
| Pricing | Upon Request |
| Brand | Arrow grand Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NGIA |
| Pricing | Available Upon Request |
| Brand | ASPEC |
|---|---|
| Origin | USA |
| Manufacturer | IonSense, Inc. |
| Model | ASAP |
| Instrument Type | Atmospheric Pressure Ionization Source |
| Mass Range | 5–3000 amu |
| Sensitivity | pg-level (dependent on coupled mass spectrometer) |
| Resolution | Determined by host MS platform |
| Accurate Mass Capability | Enabled via compatible high-resolution MS (e.g., Orbitrap, FT-ICR, QTOF) |
| Brand | ASPEC (Prosolia) |
|---|---|
| Origin | USA |
| Model | Flowprobe |
| Instrument Type | Ambient Ion Source |
| Compatible MS Platforms | Thermo Orbitrap, Bruker timsTOF, SCIEX TripleTOF & QTRAP |
| Sample Interface | Liquid Microjet Surface Sampling Probe (LMJ-SSP) |
| Spatial Resolution | ~630 µm (rapid profiling), down to ~50 µm (high-res DESI-2D integration) |
| Operating Mode | Real-time, continuous-flow in situ microextraction coupled with ESI ionization |
| Optical Guidance | Integrated coaxial camera for real-time probe positioning and surface navigation |
| Application Scope | Label-free molecular imaging of tissues, single-cell metabolomics, spatially resolved lipidomics/peptidomics, forensic toxicology, dried blood spot (DBS) analysis, time-resolved pharmacokinetics |
| Brand | Atonarp |
|---|---|
| Origin | Japan |
| Model | AST3007 |
| Mass Range | 2–285 amu |
| Resolution | 0.8 ± 0.2 (FWHM) |
| Detection Limit | 0.1 ppm |
| Sampling Speed | High-speed dynamic acquisition |
| Sensitivity | Sub-ppb for key process gases |
| Vacuum System | Turbomolecular pump |
| Detector | Faraday Cup / Secondary Electron Multiplier (FC/SEM) |
| Operating Temperature | 15–35 °C |
| Power Consumption | 350 W |
| Dimensions (L×W×H) | 299 × 218 × 331 mm |
| Weight | 15 kg |
| Brand | Atonarp |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Aston™ Process Mass Spectrometer |
| Pricing | Available Upon Request |
| Brand | Atonarp |
|---|---|
| Origin | Japan |
| Model | Aston™ |
| Application Domain | In-line Process Mass Spectrometry for Semiconductor Vacuum System Integrity Monitoring |
| Compliance Context | Designed for ISO 9001-certified semiconductor fabs |
| Environmental Rating | IP65-rated enclosure |
| Brand | Autobio |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | Autof ms1600 |
| Price Range | USD 420,000 – 560,000 |
| Instrument Type | MALDI-TOF Mass Spectrometer |
| Application Scope | Universal |
| Resolution | ≥3600 (Linear Mode) |
| Sensitivity | 50 fmol/µL (Insulin, S/N ≥ 60) |
| Mass Accuracy | <60 ppm (Internal Calibration) |
| Data Acquisition Rate | 0.5 GBit/sec |
| Stability | High Long-Term Operational Stability |
| Brand | Autobio |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | Automs TQ6000 |
| Price Range | USD 300,000–320,000 (FOB) |
| Instrument Type | Triple Quadrupole (QqQ) |
| Application Scope | General-Purpose LC-MS/MS |
| Maximum System Pressure | >12,000 psi |
| Ionization Modes | Dual ESI/APCI with Tool-Free Switching |
| Software Interface | Fully Localized Chinese GUI with Intelligent Quantitation & Method Development Engine |
| Regulatory Compliance | Designed to support GLP/GMP workflows, audit trail-enabled data handling, and 21 CFR Part 11–compliant user access control (optional configuration) |
| Brand | Banff |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | QitVenture 1 |
| Instrument Type | Portable |
| Weight | 18 kg |
| Brand | Banff |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | QitVenture 6 E |
| Instrument Type | Portable GC-MS |
| Ionization Sources | ESI, TD-ESI, APCI |
| Mass Analyzer | Quadrupole |
| Mass Range | 10–1000 m/z |
| Battery Runtime | >4 hours (typical operational mode) |
| Dimensions | <38 × 28 × 18 cm |
| Weight | <12 kg |
| Sample Introduction | Gas, Liquid, Solid (via integrated thermal desorption and direct probe options) |
| Brand | BaySpec |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Portability/Continuity/Agility |
| Instrument Type | Portable |
| Mass Range | 30–1600 Da |
| Dynamic Range | 3.5 orders of magnitude |
| Mass Resolution (FWHM) | 0.49 Da |
| Maximum Scan Rate | 15,000 Da/s |
| Mass Accuracy | ±0.3 Da |
| Weight | 10–20 kg |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | BCT-CMM |
| Instrument Type | Portable |
| Pricing | Upon Request |
| Vacuum System | Non-mechanical (e.g., turbomolecular or ion pump based) |
| Positioning | GPS and/or BeiDou GNSS optional |
| Connectivity | 5G-enabled real-time data transmission |
| Software Platform | Dedicated mobile monitoring application with georeferenced chromatographic data logging |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Triple Quadrupole (QqQ) |
| Application Field | General-Purpose |
| Mass Range | 10–2250 Da |
| Ionization Sources | Dual ESI/APCI |
| Collision Cell | Curved RF-only Quadrupole Design |
| Gas System | Counter-Flow Curtain Gas Configuration |
| Software | Integrated Intelligent Tuning, Calibration, Method Optimization & Reporting Engine |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | HMS7680 |
| Instrument Type | Ion Mobility Mass Spectrometer |
| Application Scope | General-Purpose |
| Ionization Sources | ESI and APCI |
| IM Resolution Modes | 3 Adjustable Settings |
| Mass Analyzer Configuration | Quadrupole + Orthogonal TOF |
| Collision Cell | Axial DC Voltage Gradient CID with Tunable Collision Gas |
| Temperature Control | Water-Cooled, Thermally Stabilized Flight Tube with Intelligent Compensation |
| Acquisition Mode | 4D Full-Spectrum Simultaneous Detection |
| Software Features | Automated Tuning, Real-Time Mass Calibration, Method Optimization, and Integrated Data Processing & Reporting |
| Brand | Bioyong |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | ICP-QMS |
| Regulatory Status | NMPA Certified (Registration No.: Jing Xie Zhu Zhun 20192220003) |
| Application Domain | Clinical Biochemical Analysis |
| Detection Limit | Sub-ppt (pg/L) for most elements |
| Linear Dynamic Range | 9 orders of magnitude |
| Isotopic Precision | RSD < 2% (n = 10, standard reference materials) |
| Interference Resistance | Collision/reaction cell enabled (He/H₂ mode), robust polyatomic interference correction |
| Throughput | Up to 40 multi-element clinical samples per hour (including calibration and QC) |
| Brand | Bioyong |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | ICP-MS |
| Model | Clin-ICP-QMS-II |
| Application Domain | Clinical Biochemical Assay |
| Regulatory Classification | Domestic Medical Device (Class II) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | autoflex maX |
| Instrument Type | TOF-TOF |
| Application Scope | Universal |
| Laser Repetition Rate | up to 2 kHz |
| Mass Resolution | up to 26,000 (m/z 1,000–5,000) |
| Mass Accuracy | sub-ppm (calibrated) |
| Detection Sensitivity | low amol (for peptides) |
| Ion Source | Perpetual™ laser-cleanable MALDI source |
| Detector | FlashDetector™ with 10-bit digitizer |
| Software Suite | Compass (flexControl, flexAnalysis, BioTools, GlycoWorkbench, Polymerix) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | compact |
| Instrument Type | Quadrupole-Time-of-Flight (QTOF) |
| Application Scope | Universal LC-MS/MS Platform |
| Key Specifications | 50 GBit/sec acquisition rate |
| Resolution | Ultra-High Resolution TOF (UHR-TOF) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Time-of-Flight (TOF) |
| Configuration | Dual-Source GC-MS (EI + CI) |
| Ionization Modes | Electron Ionization (EI) and Chemical Ionization (CI) with Helical Resonant Plasma (HRP) source |
| Resolution | >40,000 FWHM (m/z 200) |
| Mass Accuracy | <1 ppm RMS (calibrated) |
| Scan Rate | Up to 50 spectra/sec (full-spectrum, high-res) |
| CI Reagent Gases | N₂H⁺, H₃O⁺, H(H₂O)ₙ⁺, NH₄⁺ (software-switchable, no hardware intervention) |
| Compliance | Fully compatible with GLP/GMP workflows |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | EVOQ GC-TQ |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Chromatography Configuration | Conventional Gas Chromatography–Mass Spectrometry (GC-MS/MS) |
| Ionization Modes | Electron Ionization (EI) and Negative Chemical Ionization (NCI) |
| Vacuum System | High-Capacity Turbo-Molecular Pump |
| Detector | Extended Dynamic Range (EDR) Detector Integrated with Quadrupole Assembly |
| Ion Optics | Lens-Free Ion Path |
| q0 Collision Cell | Helium-Gas-Assisted Active Ion Focusing |
| Ion Transmission Architecture | Elliptical Ion Channel |
| Method Setup | Automated MRM Transition Library Lookup by Compound Name |
| Compliance Readiness | Designed for GLP/GMP environments |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Tandem Quadrupole (Triple Quad) |
| Configuration | LC-MS/MS |
| Application Scope | Universal Quantitative Analysis |
| Regulatory Compliance | Designed for GLP/GMP environments, compatible with 21 CFR Part 11 audit trail requirements |