Microwave Digestion Instrument
Filter
Showing 121–141 of 141 results
| Brand | Sineo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | MASTER |
| Pricing | Upon Request |
| Cavity Grade | Industrial-Grade |
| Sample Capacity | 16 / 18 / 40 Vessels per Batch |
| Microwave Source | Dual Magnetron |
| Max Temperature | 310 °C |
| Max Pressure | 15 MPa (2200 psi) |
| Brand | Sineo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | MDS-15 |
| Pricing | Upon Request |
| Cavity Grade | Industrial-Grade |
| Batch Capacity | 16 Samples |
| Microwave Source | Dual Magnetron |
| Max Temperature | 310 °C |
| Max Pressure | 15 MPa |
| Brand | Sineo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | TANK |
| Price Range | USD 35,000 – 42,000 |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 40 Positions |
| Microwave Source | 2450 MHz, Dual Magnetron, Non-Pulsed Frequency-Variable Control |
| Max Temperature | 300 °C |
| Temp Measurement Accuracy | ±0.1 °C |
| Temp Control Stability | ±1 °C |
| Max Pressure | 15 MPa |
| Brand | Sineo |
|---|---|
| Origin | Shandong, China |
| Model | TANK |
| Cavity Class | Industrial-grade |
| Sample Capacity | 12–40 positions |
| Microwave Source | 2450 MHz, dual magnetron, non-pulsed frequency-variable control |
| Max Temperature | 300 °C |
| Temp Measurement Accuracy | ±0.1 °C |
| Temp Control Stability | ±1 °C |
| Max Pressure | 15 MPa |
| Cavity Material | 316L stainless steel with multi-layer PTFE coating |
| Outer Vessel Material | Aerospace-grade composite fiber with PTFE coating (burst pressure: 70 MPa |
| max temp | 600 °C) |
| Cooling Time to Ambient | <15 min |
| Dimensions (W×D×H) | 570 × 650 × 680 mm |
| Net Weight | 65 kg |
| Power Supply | 220–240 VAC, 50/60 Hz, 16 A |
| Operating Environment | 0–40 °C, 15–80% RH |
| Brand | Sineo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | TANK eco |
| Price | Upon Request |
| Cavity Grade | Industrial-Grade |
| Sample Capacity | 6/8/10 positions |
| Max Temperature | 300 °C |
| Max Pressure | 15 MPa (≈2200 psi) |
| Power Supply | 220–240 VAC, 50/60 Hz, 20 A |
| Microwave Frequency | 2450 MHz, Variable-Frequency Magnetron |
| Installed Power | 1800 W |
| Cavity Material | 316L Stainless Steel with Multi-Layer PTFE Coating |
| Safety Door | Pop-Out Buffer Anti-Explosion Design with Dual Lock & Self-Check |
| Pressure Sensor | High-Precision Corrosion-Resistant Semiconductor Sensor |
| Temperature Monitoring | Mid-Infrared Full-Cavity Temperature Measurement |
| Control Interface | 7-inch LCD Touchscreen |
| Operating System | Android-based |
| Data Storage | 8 GB Onboard + Cloud Integration (Secure, Encrypted) |
| Compliance | FDA 21 CFR Part 11 (Audit Trail, Electronic Signatures, Role-Based Access) |
| Cooling System | High-Flow Corrosion-Resistant Fan, Auto-Adjustable Airflow, <15 min to Ambient |
| Dimensions (W×D×H) | 480 × 560 × 575 mm |
| Net Weight | 45 kg |
| Rotor Design | Independent Frame-Type High-Pressure Vessels |
| Vessel Options | Self-Venting or Non-Venting Configurations |
| Inner Vessel Material | TFM (Perfluoroalkoxy Alkane) |
| Inner Vessel Volume | 100 mL |
| Outer Vessel Material | Aerospace-Grade Composite Fiber with Full PTFE Coating |
| Design Temp/Pressure | 300 °C / 15 MPa |
| Additional Functions | Microwave-Assisted Extraction (MAE), Microwave Synthesis (Organic & Inorganic) |
| Brand | Sineo |
|---|---|
| Origin | Shandong, China |
| Model | TANK eco |
| Cavity Class | Industrial-grade |
| Sample Capacity | 6/8/10 positions |
| Microwave Source | Frequency-variable magnetron with high-energy microwave field emission |
| Max Temperature | 300 °C |
| Max Pressure | 15 MPa (≈2200 psi) |
| Power Supply | 220–240 VAC, 50/60 Hz, 20 A |
| Microwave Frequency | 2450 MHz |
| Installed Power | 1800 W |
| Max Microwave Output | 1000 W |
| Cavity Volume | 31.6 L |
| Cavity Material | 316 stainless steel with multi-layer PTFE coating |
| Safety Door | Auto-ejecting explosion-proof sliding door with anti-leakage interlock |
| Cooling | High-flow corrosion-resistant turbo fan |
| Dimensions (W×D×H) | 480 × 560 × 575 mm |
| Net Weight | 45 kg |
| Pressure Control Range | 0–15 MPa, accuracy ±0.01 MPa |
| Temperature Control Range | 0–305 °C (IR), or –40–305 °C (fiber-optic), accuracy ±0.1 °C |
| Safety Systems | COT real-time anomaly monitoring, directional safety bolt pressure relief, full-cavity pressure monitoring, microwave cutoff on fault detection |
| Software | Android-based OS |
| Brand | Sineo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | TANK MAX |
| Quotation | Upon Request |
| Cavity Class | Industrial-Grade |
| Microwave Source | 2450 MHz Frequency-Modulated Magnetron with Continuous Non-Pulsed High-Energy Microwave Emission |
| Max Operating Temperature | 300 °C |
| Max Operating Pressure | 20 MPa |
| Brand | Sineo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | TANK MAX |
| Microwave Source | 2450 MHz frequency-variable magnetron with non-pulsed continuous-wave high-energy microwave emission |
| Max Operating Temperature | 300 °C |
| Max Operating Pressure | 20 MPa |
| Power Output | 1500 W |
| Cooling System | Circulating water cooling (5–40 °C) |
| Control System | Embedded Android OS with graphical user interface |
| Sample Vessel Capacity Options | 6, 10, 18, 24, and 28 positions |
| Vessel Materials | PTFE-TFM, high-purity quartz, borosilicate glass |
| Input Voltage | 220–240 VAC, 50/60 Hz, 20 A |
| Ambient Operating Temperature | 0–40 °C |
| Relative Humidity Range | 15–80 % RH |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Origin Category | Imported |
| Model | speedwave XPERT |
| Chamber Class | Industrial-Grade |
| Sample Capacity | 12 or 24 samples per batch |
| Microwave Source | Magnetron |
| Max Temperature | 300 °C |
| Max Pressure | 150 bar |
| Temperature Sensing | Patented Fiber-Optic Sensor Technology |
| Safety Features | Top-Loading with Electronic Lock, Continuous Cavity Ventilation with Acid Fume Extraction, Overheat-Responsive Power Modulation |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | MDS-6G |
| Cavity Class | Industrial Grade |
| Sample Capacity | 8 vessels |
| Microwave Source | Dual Magnetron |
| Max Temperature | 300 °C |
| Max Pressure | 10 MPa (1500 psi) |
| Pressure Control | Piezoelectric Crystal Sensor (Range: 0–10 MPa, Accuracy: ±0.01 MPa) |
| Temperature Sensing | High-Precision Pt100 RTD (Range: 0–300 °C, Accuracy: ±1 °C) |
| Microwave Frequency | 2450 MHz |
| Max Microwave Output Power | 1000 W |
| Total Installed Power | 1800 W |
| Cooling Time | ≤15 min |
| Dimensions (W×D×H) | 450 × 515 × 510 mm |
| Net Weight | 40 kg |
| Vessel Configuration | MP-100 rotor with TFM inner vessels (100 mL), XTRA FIBER composite outer vessels |
| Brand | Milestone |
|---|---|
| Origin | Italy |
| Model | UltraCLAVE |
| Category | Microwave Digestion Instrument for Sample Preparation |
| Chamber Type | Single Pre-Pressurized Reaction Chamber |
| Max Operating Temperature | Up to 300 °C |
| Max Operating Pressure | Up to 200 bar |
| Chamber Volume | 4.2 L |
| Sample Capacity | ≥25 g per vessel |
| Batch Throughput | ≥77 samples |
| Acid Consumption | 2–3 mL per sample |
| Vessel Compatibility | Standard quartz, borosilicate glass, and TFM-lined tubes |
| Automation | Fully automated sealing/unsealing and pressure release (<10 s per vessel) |
| Temperature Measurement Accuracy | ±0.5 °C (RTD-based) |
| Temperature Uniformity | ±2 °C across chamber volume |
| Pressure Control Stability | ±1 bar |
| Regulatory Compliance | Designed to support GLP/GMP workflows, audit-trail-ready software architecture compatible with FDA 21 CFR Part 11 requirements |
| Brand | Xianghu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | XH-800DE |
| Price Range | USD 14,000 – 21,000 |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 6–10 samples simultaneously (programmable per-vessel control for 1–10 samples) |
| Microwave Source | Single Magnetron |
| Max Temperature | 260 °C |
| Max Pressure | 6 MPa (870 psi) |
| Brand | Xianghu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | XH-800X |
| Price Range | USD 28,000–42,500 (FOB) |
| Cavity Class | Industrial Grade |
| Sample Capacity | 15 samples per batch |
| Microwave Source | Dual Magnetron |
| Max Temperature | 260 °C |
| Max Pressure | 1500 psi |
| Brand | Xianghu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | XH-800B |
| Price Range | USD 14,000–21,500 |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 8 or 10 vessels |
| Microwave Source | Single Magnetron |
| Max Operating Temperature | 260 °C |
| Max Rated Pressure | 10 MPa |
| Microwave Power Output | 0–1000 W (8-vessel mode), 0–1200 W (10-vessel mode), continuously adjustable |
| Temperature Control Range | 0–260 °C |
| Temp. Measurement Accuracy | ±0.1 °C |
| Temp. Control Stability | ±1 °C |
| Pressure Control Range | 0–6 MPa |
| Max Vessel Burst Pressure Rating | 10 MPa |
| Pressure Measurement Accuracy | ±0.01 MPa |
| Pressure Sampling Rate | 150–200 readings/sec |
| Cavity Volume | ≥42 L |
| Cavity Material | Austenitic stainless steel (316L equivalent) |
| Interior Coating | 5-layer PTFE-based fluoropolymer |
| Rotational Platform | Coaxial, unidirectional, constant-speed |
| Cooling Duration Post-Digestion | 15 min (fan + rotation active) |
| Exhaust Airflow | ≥5 m³/min |
| Microwave Leakage | Compliant with GB 10436-2008 (China National Standard, equivalent to IEC 61000-4-3 & EN 61000-4-3 for RF emission limits) |
| Brand | Xianghu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | XH-800D |
| Price Range | USD 7,000–14,000 (FOB) |
| Cavity Class | Industrial-Grade |
| Batch Capacity | 6 Samples |
| Microwave Source | Single Magnetron |
| Max Temperature | 300 °C |
| Max Pressure | 870 psi (6.0 MPa) |
| Safety Operating Limits | ≤260 °C / ≤6.0 MPa |
| Cooling | Automated Post-Digestion Air Cooling |
| Control Interface | Integrated Touchscreen with Real-Time Temp/Pressure Curve Logging |
| Data Storage | Onboard Parameter Archiving |
| Remote Operation | Ethernet/WiFi-Enabled Supervisory Control |
| Brand | Ying'an Meicheng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ME Series |
| Pricing | Available Upon Request |
| Cavity Rating | Industrial-Grade |
| Sample Capacity | Up to 10 Vessels per Run |
| Microwave Source | Magnetron-Based, Frequency-Variable (PID-Controlled) |
| Max Temperature | 300 °C |
| Temp Measurement Accuracy | ±0.5 °C |
| Max Pressure | 6 MPa (870 psi) |
| Pressure Measurement Method | Direct Contact, Real-Time Transducer |
| Pressure Control Resolution | 0.01 MPa |
| Safety Features | Dual Interlock Door Lock, Rupture Discs (200 psi & 400 psi), Overpressure/Overtemperature Auto-Shutdown, Pt100 Integrated Temperature Monitoring |
| Brand | yoyilab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Titan-6 |
| Price | USD 6,700 (FOB Shanghai) |
| Cavity Grade | Industrial-Grade |
| Batch Capacity | 6 Samples |
| Microwave Source | Single Magnetron |
| Max Temperature | 300 °C |
| Max Pressure | 20 MPa |
| Brand | yoyilab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | TITAN10 |
| Price Range | USD 7,000–14,000 |
| Cavity Class | Industrial-Grade |
| Batch Capacity | 10 Samples |
| Microwave Source | Single Magnetron |
| Max Temperature | 300 °C |
| Max Pressure | 20 MPa |
| Brand | yoyilab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Region Category | Domestic (China) |
| Model | TITAN10B |
| Price Range | USD 7,000 – 14,000 |
| Cavity Class | Industrial-Grade |
| Batch Capacity | 10 samples |
| Microwave Source | Dual Magnetron (3600 W total output) |
| Max Temperature | 300 °C |
| Max Pressure | 20 MPa |
| Cavity Material | 316L Stainless Steel with 8-layer PFA coating |
| Temperature Sensor | High-precision Pt100 RTD (–40 to 500 °C |
| Pressure Sensor | Piezoelectric crystal (0–20 MPa |
| Safety Features | Auto-retracting safety door, dual-stage pressure relief (bow-spring module + burst disc), full-enclosure aerospace-grade carbon-fiber outer vessels with PFA spray coating (rated to 85 MPa), 360° real-time cavity monitoring via optical viewport and LED status array |
| Rotation | Unidirectional continuous rotation |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Dimensions (L×W×H) | 480 × 550 × 630 mm |
| Net Weight | 57 kg |
| Operating Environment | 0–50 °C, 15–80% RH |
| Key | Brand: yoyilab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Model | TITAN12B |
| Cavity Class | Industrial-Grade |
| Batch Capacity | 12 samples |
| Microwave Source | Dual Magnetron (3600 W total output) |
| Max Temperature | 300 °C |
| Max Pressure | 20 MPa |
| Cavity Material | 316L Stainless Steel |
| Cavity Coating | 8-layer PFA fluoropolymer |
| Outer Vessel Material | Aerospace-grade composite fiber with full PFA encapsulation (rated to 85 MPa) |
| Temperature Sensor | High-precision Pt1000 RTD (−40–500 °C, ±0.1 °C control accuracy) |
| Pressure Sensor | Piezoelectric crystal transducer (0–20 MPa, ±0.01 MPa control accuracy, ±0.1 MPa display resolution) |
| Rotation | Unidirectional continuous rotation |
| Safety Systems | Active real-time monitoring + passive pressure-relief (bow-spring module + burst disc), auto-ejecting safety door, triple-lock interlock, multi-point LED status feedback |
| Brand | yoyilab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | TITAN16B |
| Price Range | USD 7,000–14,000 (FOB) |
| Cavity Class | Industrial-Grade |
| Batch Capacity | 16 Samples |
| Microwave Source | Dual Magnetron (3600 W Total Output) |
| Max Temperature | 300 °C |
| Max Pressure | 20 MPa |
| Cavity Material | 316L Stainless Steel with 8-Layer PFA Coating |
| Cooling Method | Top-Exhaust Forced Air |
| Safety Certification | Compliant with IEC 61000-4 Electromagnetic Compatibility Standards |
| Regulatory Alignment | Designed for GLP/GMP environments |