Moisture Analyzer
Filter
Showing 1–30 of 164 results
| Brand | A&D |
|---|---|
| Origin | Shanghai, China (Imported Japanese Design & Core Technology) |
| Heating Source | 400 W Halogen Lamp |
| Weighing Range | 51 g |
| Readability | 0.002 g |
| Moisture Content Accuracy | ±0.05 % / ±0.1 % / ±1.0 % (depending on sample mass and drying behavior) |
| Temperature Range | 50–200 °C |
| Sample Pan Diameter | 85 mm |
| Dimensions (W×D×H) | 215 × 320 × 173 mm |
| Weight | ~6.0 kg |
| Measurement Modes | Standard, Automatic, Timed, Manual |
| Drying Programs | Standard, Ramp, Step, Rapid |
| Data Storage | 10 measurement methods, 50 result records |
| Interface | RS-232 serial port |
| Compliance | GLP/GMP/ISO-compliant data logging with timestamp, operator ID, calibration history, and audit trail capability |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MS-70 |
| Heating Method | 400 W Linear Halogen Lamp with SRA (Secondary Radiation Assist) Technology |
| Weighing Range | 71 g |
| Readability | 0.0001 g |
| Moisture Resolution | 0.001 % / 0.01 % / 0.1 % |
| Drying Temperature Range | 30–200 °C |
| Interface | RS-232C |
| Compliance | GLP/GMP/ISO 9001, USP <921>, ASTM E1064, ISO 11857, EN ISO 13726 |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | MS-70 |
| Heating Source | 400 W Halogen Lamp |
| Weighing Range | 71 g |
| Readability | 0.0001 g |
| Moisture Content Resolution | 0.001 % / 0.01 % / 0.1 % |
| Temperature Range | 30–200 °C |
| Sample Pan Diameter | 85 mm |
| Dimensions (W×D×H) | 215 × 320 × 173 mm |
| Weight | 6.0 kg |
| Compliance | GLP/GMP/ISO-compliant data logging, RS-232 interface, WinCT-Moisture software support |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Co., Ltd. |
| Type | Imported Instrument |
| Model | MS-74AT |
| Heating Method | 400 W Linear Halogen Lamp |
| Moisture Resolution | 0.001% |
| Weighing Capacity | 71 g |
| Weighing Accuracy | 0.0001 g |
| Temperature Range | 30–200 °C |
| Measurement Modes | Standard / Timed / Custom |
| Heating Profiles | Standard / Gradual / Step / Rapid |
| Sample Pan Diameter | Ø90 mm |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Co., Ltd. |
| Type | Imported Instrument |
| Model | MS74A |
| Heating Method | 400 W Linear Halogen Lamp |
| Moisture Resolution | 0.001% |
| Weighing Capacity | 71 g |
| Weighing Accuracy | 0.0001 g |
| Moisture Measurement Accuracy (≥5 g sample) | ±0.01% |
| Temperature Range | 30–200 °C |
| Sample Pan Diameter | φ90 mm |
| Display | High-Contrast LCD |
| Measurement Modes | Standard / Timed / Custom |
| Heating Profiles | Standard / Gradual / Step / Rapid |
| Predefined Methods | 100 templates |
| Stored Programs | Up to 300 |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Co., Ltd. |
| Type | Imported |
| Model | MX-50 |
| Heating Method | Halogen Lamp (400 W, Straight-Tube) |
| Moisture Range Display Resolution | 0.01% / 0.1% |
| Max Sample Capacity | 51 g |
| Weighing Accuracy | 0.001 g |
| Drying Temperature Range | 50–200 °C |
| Communication Interface | RS-232C |
| Compliance | GLP/GMP/ISO 9001-ready |
| Calibration Standard | Sodium Tartrate Dihydrate (15.66 ± 0.2 % w/w H₂O) |
| Brand | A&D |
|---|---|
| Model | MX-50 |
| Heating Source | 400 W Halogen Lamp |
| Weighing Range | 51 g |
| Readability | 0.001 g |
| Moisture Content Resolution | 0.01 % / 0.1 % |
| Temperature Range | 50–200 °C |
| Display | Fluorescent LCD |
| Interface | RS-232 |
| Compliance | GLP/GMP/ISO |
| Software | WinCT-Moisture (PC-Connected) |
| Sample Compatibility | Solids, Powders, Granules, Pastes, Liquids |
| Calibration Standard | Disodium Tartrate Dihydrate (15.66 % ± 0.3/−0.1 % H₂O) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Co., Ltd. |
| Type | Imported |
| Model | MF-50 |
| Heating Method | Halogen Lamp (400 W, Straight-Tube) |
| Maximum Sample Capacity | 51 g |
| Weighing Accuracy | 0.002 g |
| Moisture Resolution | 0.05 % / 0.1 % / 1 % |
| Drying Temperature Range | 50–200 °C |
| Measurement Modes | Relative Moisture Content / Absolute Moisture Content / Dry Basis / Wet Basis |
| Interface | RS-232C |
| Compliance | GLP/GMP/GCP, ISO 9001, ISO/IEC 17025 applicable |
| Calibration Standard | Sodium Tartrate Dihydrate (15.66 % ±0.3/−0.1 % H₂O) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | MF-50 |
| Maximum Sample Capacity | 51 g |
| Weighing Resolution | 0.002 g |
| Moisture Content Accuracy | ±0.20% (for samples >1 g), ±0.05% (for samples >5 g) |
| Moisture Display Precision | 0.05% / 0.1% / 1% |
| Drying Temperature Range | 50–200 °C (1 °C increments) |
| Heating Source | Halogen lamp (400 W, straight-tube, ~5000 h lifetime) |
| Measurement Modes | Standard / Auto / Rapid / Timer / Manual |
| Moisture Expression Modes | Relative moisture / Absolute moisture / Dry basis / Wet basis |
| Data Storage | 50 measurement results |
| Predefined Programs | 10 |
| Interface | RS-232 |
| Software | WinCT-Moisture (graphical real-time analysis) |
| Sample Pan Diameter | Ø85 mm (optional Ø110 mm) |
| Power Supply | AC 100–120 V (3 A) or 200–240 V (1.5 A), 50/60 Hz, ~400 W |
| Dimensions (W×D×H) | 215 × 320 × 173 mm |
| Weight | ~6 kg |
| Operating Environment | 5–40 °C, <85% RH |
| Brand | AA OPTO Electronic |
|---|---|
| Origin | Japan |
| Model | PM-888-X (Upgraded successor to PM-8188-A) |
| Measurement Principle | Radio-frequency capacitance |
| Accuracy | ±0.5% w/w (within specified moisture ranges) |
| Sample Handling | Auto-feed hopper (for grains) or cup loading (for seeds, beans, tea, spices) |
| Moisture Range Coverage | 0–45% w/w, segmented by pre-programmed material-specific calibration curves |
| Brand | Aboni |
|---|---|
| Origin | Germany |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Sample Form | Solids, Powders, Films |
| Measuring Principle | Hydride-Generation Gas Evolution (CaH₂ Reaction) |
| Absolute Range | 0.2–30 mg H₂O |
| Relative Range | 0.0005–5 % w/w |
| Reproducibility | ±0.1 mg H₂O (at 1 mg), ±0.3 mg H₂O (at 20 mg) |
| Sample Weight | 0.01–50 g (up to 100 g, density-dependent) |
| Sample Volume | ~50 cm³ |
| Test Temperature | 50–210 °C (1 °C increments) |
| Ambient Air Monitoring | Temp (0.1 °C), RH (0.1 %), Pressure (1 mbar) |
| Reagent | Calcium Hydride (CaH₂) powder (~0.1 g/test) |
| Power Supply | 100/115/230 VAC |
| Dimensions | 285 × 170 × 250 mm (H×W×D) |
| Weight | 4.6 kg |
| Interface | Bidirectional RS-232 |
| PC Requirements | Windows® 98/ME/2000/NT/XP with RS-232 or USB (via adapter) |
| Compliance | ISO 15512 |
| Brand | Adam |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMB |
| Pricing | Available Upon Request |
| Capacity | 50 g / 200 g |
| Readability | 0.001 g / 0.01 % (PMB 53) |
| Repeatability (S.D.) | 0.005 g / 0.05 % (10 g sample, PMB 53) |
| Pan Diameter | Ø90 mm |
| Heating Range | 50–160 °C |
| Max. Test Duration | 99 minutes |
| Heating Source | 400 W Halogen Lamp |
| Heating Modes | Ramp, Step, Standard |
| Stabilization Time | 2–3 s |
| Display | Dual-line LED backlight with range-tracking indicator |
| Interfaces | USB Host, USB I/O, RS-232 |
| Internal Memory | 99 test results, 49 test methods |
| External Storage | USB flash drive support |
| Calibration | External calibration only |
| Power Supply | 110/220 V, 50/60 Hz |
| Operating Temperature | 0–40 °C |
| Dimensions (W×D×H) | 360 × 250 × 185 mm |
| Net Weight | 6 kg |
| Languages | English, German, French, Spanish |
| Units | g, % liquid, % solid, ATRO % M (moisture on dry basis), ATRO % S (solids on dry basis) |
| Brand | Adam |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | PMB |
| Heating Source | Halogen Lamp (400 W) |
| Measurement Principle | Thermogravimetric Analysis (TGA) via Halogen-Heated Infrared Drying |
| Display Modes | %Moisture, %Solids, %Moisture/Dry Weight, %Solids/Dry Weight |
| Termination Methods | Manual Stop, Timer-Based Auto-Stop, Stability-Based Auto-Stop |
| Max Test Duration | 99 min |
| Temperature Range | 50–160 °C (1 °C increments) |
| Heating Profiles | Standard, Step, Ramp |
| Calibration | External Weighing Calibration |
| Data Storage | 99 test results + 49 user-defined methods + 1 factory preset |
| Interface Options | RS-232, USB Serial, USB Host (for flash drive logging) |
| Language Support | English, French, German, Spanish |
| Date Format Options | YMD, DMY, MDY |
| Audible Alert | Configurable end-of-test beep |
| Weighing Platform Diameter | 90 mm |
| Power Supply | 115 VAC or 230 VAC, 50/60 Hz |
| Brand | Adamek |
|---|---|
| Origin | United Kingdom |
| Model | PMB53 / PMB202 |
| Max Capacity | 50 g / 200 g |
| Readability | 0.001 g / 0.01 % (PMB53) |
| Repeatability | ±0.005 g / ±0.05 % (10 g sample, PMB53) |
| Heating Source | 400 W halogen lamp |
| Temperature Range | 50–160 °C (1 °C increments) |
| Drying Time | 1–99 min |
| Moisture Range | 0–100 % |
| Display | Backlit blue LCD with dual-line readout and capacity tracking bar |
| Interface | RS-232, USB Host (for USB flash drive), USB I/O (for PC connection) |
| Internal Memory | 99 test results, 49 test methods |
| External Storage | USB mass storage support |
| Pan Diameter | 90 mm |
| Pan Clearance | 30 mm |
| Dimensions (W×D×H) | 250 × 360 × 185 mm |
| Net Weight | 6 kg |
| Operating Ambient | 0–40 °C |
| Calibration | External |
| Heating Modes | Ramp, Step, Standard |
| Auto-Start | Enabled upon lid closure |
| Safety | Kensington lock slot |
| Warranty | 3 years |
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | HSM810 |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Electrolytic (P2O5 Sensor) |
| Operating Temperature | -20 to 50°C |
| Accuracy | ±2°C |
| Repeatability | ±0.2°C |
| Dew Point Range | -80 to +20°C |
| Resolution | 0.01°C dew point or 0.1 ppmv |
| Gas Flow Rate | SF6: 0.5–0.9 L/min |
| H₂ | 0.1–0.4 L/min |
| Pressure Range | 0–1.0 MPa |
| Probe Protection | Stainless steel sintered filter |
| Power Supply | 110–220 VAC / internal Li-ion battery (≥8 h continuous operation) |
| Dimensions | 305 × 202 × 261 mm |
| Weight | 2.5 kg |
| Data Interface | RS232 / USB (driver-free) |
| Storage Temperature | -40 to +70°C |
| Operating Environment | -35 to +60°C, 0–20 bar |
| File System | FAT16 |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DP8000 |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Chilled-Mirror–Compensated Semiconductor Sensor (Dew-Point-Specific Thermoelectric Cooling) |
| Operating Temperature | -10 °C to +50 °C |
| Accuracy | ±1 °C (Td, at stable conditions, -60 °C to +20 °C range) |
| Repeatability | ±1 °C |
| Dew Point Range Options | -80 °C to +20 °C |
| Resolution | 0.1 °C (Td) or 0.1 ppmv |
| Response Time (63%/90%) | 5 s / 45 s (-20 °C → -20 °C Td) |
| Gas Flow Rate | 0.1–0.4 L/min (H₂), 0.5–0.9 L/min (SF₆) |
| Pressure Rating | 0–1.0 MPa (operational), 0–20 bar (mechanical) |
| Probe Protection | Stainless Steel Sintered Filter |
| Power Supply | 110–220 VAC / Internal Li-ion Battery (auto-switching, overcharge/over-discharge protection) |
| Data Interface | USB (class-compliant, no driver required), RS232 |
| Storage Temperature | -40 °C to +70 °C |
| Dimensions & Weight | 300 × 200 × 260 mm, 3.5 kg |
| Brand | ALPHA |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | DSP-Ex |
| Product Category | Portable Dew Point Meter |
| Measurement Principle | Electrolytic (P2O5 Sensor) |
| Accuracy | ±2 °C dew point |
| Certification | ATEX Ex ia IIC T3/T4 |
| Operating Pressure | Ambient (101.3 kPa ±10%) |
| Dew Point Range | –110 °C to +20 °C |
| Battery Life | >250 hours continuous operation |
| Power Source | Two C-cell alkaline batteries |
| Display Units | °C, °F, ppm(v), ppb(v), ppm(w), g/m³, lb/MMSCF |
| Gas Compatibility | Air, Ar, H₂, SF₆, CO₂, N₂ (custom molecular weight input supported for ppm(w)) |
| Sensor Interchangeability | Fully field-replaceable with traceable calibration |
| Calibration Certificate | UKAS-traceable to NPL and international humidity standards |
| Sampling Interface | Stainless steel quick-connect fitting + integrated desiccant drying chamber |
| Accessories Included | 2 m PTFE-braided stainless steel sampling hose, anti-static carry case, user manual, factory calibration certificate |
| Brand | Alpha Moisture |
|---|---|
| Origin | United Kingdom |
| Model | DS-1000 |
| Product Type | Online Dew Point Meter |
| Measurement Principle | Capacitive Aluminum Oxide Sensor |
| Operating Temperature | 10 to +50 °C |
| Accuracy | ±0.1 °C / ±0.1 °F / ±0.1 ppm(v) |
| Repeatability | ±0.1 °C / ±0.1 °F / ±0.1 ppm(v) |
| Dew Point Range (PL Sensor) | −110 to +20 °C (0–23,000 ppm(v)) |
| Dew Point Range (BL Sensor) | −80 to +20 °C (0–23,000 ppm(v)) |
| Resolution | 0.1 °C / 0.1 °F / 0.1 ppm(v) |
| Display | 4-digit LED |
| Analog Output | 4–20 mA |
| Sample Temperature Range | −10 to +50 °C |
| Maximum Operating Pressure | 50 bar |
| Calibration Accuracy | ±2 °C dew point (NPL-traceable certificate supplied) |
| Calibration Method | Linear two-point field calibration supported by manufacturer or authorized distributor |
| Power Supply | 90–250 VAC, 50/60 Hz |
| Alarm Configuration | Two user-configurable dew point setpoints with front-panel adjustment |
| Brand | Alpha Moisture |
|---|---|
| Origin | United Kingdom |
| Model | SADPmini |
| Type | Portable Dew Point Meter |
| Measurement Principle | Aluminum Oxide Capacitive Sensor |
| Operating Temperature | 10–60 °C |
| Accuracy | ±2 °C |
| Repeatability | 0.2 °C |
| Resolution | 0.1 °C or 0.1 ppm(v) |
| Dew Point Range Options | –110 to –20 °C (SR), –100 to 0 °C (PL), –80 to –20 °C (RD), –80 to 0 °C (GY), –80 to +20 °C (BL) |
| Sampling Temperature | –10 to +60 °C |
| Maximum Operating Pressure | < 0.3 kgf/cm² (≈ 30 kPa gauge) |
| Ingress Protection | IP54 / NEMA 12 |
| Power Supply | Rechargeable Battery (250 h continuous operation) |
| Data Storage | 16,000 records |
| Display | 128 × 64 pixel LCD |
| Calibration | Factory-traceable to UKAS/NIST standards |
| Output Options | USB, RS-485, optional 4–20 mA analog output |
| Gas Compatibility | Air, N₂, CO₂, SF₆, H₂, Ar, and other gases with known molecular weight |
| Brand | Alpha Moisture |
|---|---|
| Origin | UK |
| Model | SADPu-D |
| Type | Portable Dew Point Meter |
| Measurement Principle | Aluminum Oxide Capacitive Sensor |
| Operating Temperature | -20 to +50 °C |
| Accuracy | ±2 °C DP |
| Repeatability | ±0.5 °C DP |
| Dew Point Range | Standard –80 to 0 °C DP (0–6000 ppmv, plus extended low-range 0–10 ppmv option) |
| Response Time | <20 s to 90% of final reading |
| Power Supply | 6 × C-cell alkaline batteries (≥150 h continuous operation |
| Weight | 5.5 kg net / 7 kg gross |
| Dimensions | 224 × 202 × 275 mm |
| Ingress Protection | IP65 |
| Explosion Protection | EEx ia IIC T5 |
| Storage Temperature | –50 to +70 °C |
| Humidity Range | 0–98% RH (non-condensing) |
| Display | LCD, dual units (°C DP and ppmv) |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | Aquatrac-V |
| Measurement Principle | Calcium Hydride Reaction (DIN EN ISO 15512:2019) |
| Resolution | 0.0001% H₂O |
| Application | Residual Moisture Analysis in Thermoplastics & MFR Sample Preparation |
| Compliance | Fully compliant with DIN EN ISO 15512:2019 for selective water determination in plastics |
| Software | Aquatrac Control Software with LIMS/ERP integration capability |
| Data Integrity | Audit trail, user access levels, electronic signatures (21 CFR Part 11 ready) |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | MT-CA / Aquatrac-V |
| Measurement Principle | Gravimetric (MT-CA), Calcium Hydride Reaction + Vacuum Pressure Monitoring (Aquatrac-V) |
| Moisture Range | 0.1% to 99.9% (MT-CA) |
| Compliance | DIN EN ISO 15512:2019, ICC 113, ISO 712, EC Tobacco Specifications |
| Software | MetaBridge v3.x (FDA 21 CFR Part 11 compliant audit trail, LIMS/ERP integration, GLP/GMP workflow support) |
| Sample Throughput | Up to 10 samples per run (MT-CA) |
| Standards Support | Preloaded methods for flour, tobacco, polymers, pasta, coffee, building materials |
| Brand | APM |
|---|---|
| Origin | Germany |
| Model | MT 1000 |
| Product Type | Online Dew Point / Trace Moisture Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | -20 °C to +50 °C |
| Accuracy | ±0.4 ppm or ±5% of reading |
| Range | 0–2000 ppm H₂O |
| Resolution | 0.1 ppm |
| Display | Color touchscreen with independent keypad control |
| Analog Output | 4–20 mA (field-scalable) |
| Alarm Output | Relay (NO/NC), fully configurable across full scale |
| Power Supply | 220 VAC, 50 Hz, 1×1.0 A fuse |
| Enclosure Options | Wall-mount, benchtop, rack-mount, portable (mains-powered only) |
| Dimensions | 320 × 240 × 230 mm (W×H×D) |
| Weight | ~5 kg |
| Sensor Cell Material | PVDF and stainless steel |
| Electrode Material | Platinum |
| Sample Flow Rate | 20 NL/h or 100 NL/h (user-selectable) |
| Sample Pressure (at sensor) | ≤200 mbar |
| Sample Temperature | +5 °C to +65 °C |
| Response Time | <1 s |
| Gas Fitting | 6 mm compression fitting |
| Probe Cable | Standard 1.4 m (extendable up to 150 m) |
| Electrical Connector | Binder type |
| Brand | Aqualab |
|---|---|
| Origin | USA |
| Model | 4TE |
| Measurement Principle | Chilled-Mirror Dew Point |
| Operating Temperature Range | 4–50 °C |
| Accuracy | ±0.003 aw |
| Repeatability | ±0.001 aw |
| Application | Laboratory-Grade Water Activity Analysis |
| Brand | Aqualab |
|---|---|
| Origin | USA |
| Model | Pre |
| Measurement Principle | Chilled-Mirror Dew Point |
| Operating Temperature Range | 4–50 °C |
| Repeatability | ±0.01 a<sub>w</sub> |
| Application | Laboratory-Grade Dew Point Water Activity Analyzer |
| Compliance | AOAC, FDA, ISO 21807, USP <1112>, ASTM F1980 |
| Sample Temperature Control | Precisely maintained at 25 °C (±0.1 °C) |
| Typical Measurement Time | < 5 minutes |
| Calibration | Factory-calibrated with NIST-traceable standards |
| Brand | Aqualab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ROS 1 |
| Pricing | Available Upon Request |
| Measurement Principle | Standard Gravimetric Loss-on-Drying (LOD) with Real-Time Mass Monitoring |
| Heating Method | Resistive Coil Conduction (Not Halogen or Microwave) |
| Sample Capacity | 9 Independent Positions |
| Temperature Range | 50–150 °C (1 °C Increments) |
| Balance Readability | 0.0001 g |
| Max Load per Pan | 50 g |
| Sample Weight Range | 1–15 g |
| Moisture Range | 0.1–100 % w/w |
| Accuracy | ±0.15 % |
| Repeatability (4 g) | ±0.05 % |
| Repeatability (10 g) | ±0.01 % |
| Compliance | AOAC 937.02, ASTM D4442, ISO 4463, USP <921>, FDA 21 CFR Part 11 Ready (with optional software audit trail) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | AQV-2200 |
| Pricing | Upon Request |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SDW-300S / SDW-600W / SDW-120F |
| Price | Upon Request |
| Weighing Accuracy | 0.01 g / 0.005 g / 0.005 g / 0.001 g |
| Max Capacity | 300 g / 300 g / 600 g / 120 g |
| Density Resolution | 0.001 g/cm³ / 0.001 g/cm³ / 0.001 g/cm³ / 0.0001 g/cm³ |
| Measurement Principle | Archimedean buoyancy method (hydrostatic weighing) |
| Sample Types | Solids, granules, foams, floating materials, porous bodies, thin films, and water-absorbing specimens |
| Measurement Time | ~10 seconds |
| Interface | RS-232 serial output |
| Compliance Standards | ASTM D792, ASTM D297, ISO 1183, ISO 2781, GB/T 1033, GB/T 2951, GB/T 3850, GB/T 533, JIS K6268, HG4-1468 |
| Brand | BenAng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Titration Mode | Fully Automatic |
| Measurement Resolution | 0.1 ppm |
| Moisture Content Range | 0.00001% (0.1 ppm) to 100% |
| Measurement Accuracy | ±0.1 ppm |
| Minimum Dispensing Volume | 0.5 µL |
| Titration Control Precision | ±0.1 mV |
| Repeatability | ≤0.0002% RSD |
| Linearity Correlation Coefficient | ≥0.9999 |
| Power Consumption | <50 W |
| Operating Voltage | AC 220 V ±10%, 50 Hz |
| Ambient Temperature Range | 5–40 °C |
| Relative Humidity Limit | ≤85% RH (non-condensing) |
| Brand | Bigdipper |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | HBD4-MS1204Dip |
| Price Range | USD 1,400–4,200 |
| Measurement Principle | High-Frequency Capacitance Sensing (1–10 MHz) |
| Range | 0.01–100.0% w/w moisture |
| Repeatability | ±0.5% FS |
| Accuracy | ±2.0% FS |
| Response Time | <100 ms (electrical), <15 s (full system stabilization at 25 °C) |
| Sample Temp. | −40 to +85 °C |
| Max. Process Pressure | <0.3 MPa |
| Ambient Temp. | −10 to +60 °C |
| Power Supply | Rechargeable 9 V NiCd battery (HBD5), 4 h continuous operation, 1 week standby |
| Total Power Consumption | <150 mW |
| Explosion Protection | Ex d ia IIC T5 (IEC 60079-0, -1, -11) |
| Output Interface | RS232 & RS485 (STIMcom default |
| Enclosure Rating | NEMA 2 |
| Sensor Dimensions | Ø24 × 240 mm (customizable) |
| Probe Mounting | 1″ NPT or ZG1″ thread |
| Instrument Dimensions | 98 × 32 × 185 mm |
| Weight | <0.7 kg |
| Long-Term Stability | ±1% over 5 years |
| Compliance | ASTM D6304, ISO 8533, IEC 61000-6-2/6-4 (EMC), RoHS |