Molecular Fluorescence Spectrometer
Filter
Showing 61–90 of 103 results
| Brand | Lengguang Tech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Model | F96Pro |
| Wavelength Range (Excitation) | 200–850 nm |
| Wavelength Range (Emission) | 200–900 nm |
| Excitation Source | 150 W Ozone-Free Xenon Lamp (Hamamatsu, 2000 h lifetime) |
| Monochromator | Czerny-Turner grating monochromator with interference filters |
| Slit Width (Spectral Bandpass) | 10 nm |
| Spectral Resolution | 10 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | ≤0.5 nm |
| Sensitivity (S/N) | >150:1 (at water Raman peak, 350 nm excitation) |
| Scan Speed | Up to 48,000 nm/min (10-point resolution) |
| Linearity (R²) | ≥0.995 |
| Standard Excitation Filter | 365 nm interference filter |
| Software | Quantitative & qualitative analysis suite with derivative spectroscopy (1st–4th order), multi-curve overlay, kinetic time-scan, spectral math, peak integration, and calibration curve fitting (linear, quadratic, cubic) |
| Brand | Lengguang Tech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Model | F96S |
| Dispersion Element | Holographic Grating |
| Slit Width (Spectral Bandwidth) | 10 nm |
| Spectral Resolution | 10 nm |
| Sensitivity | >90:1 (Water Raman SNR) |
| Wavelength Accuracy | ±1.0 nm |
| Excitation Wavelength Range | 250–600 nm (LED-based) |
| Emission Wavelength Range | 200–650 nm |
| Emission Wavelength Repeatability | ≤0.5 nm |
| Standard Excitation Sources | 365 nm, 376 nm, 392 nm, 405 nm LEDs |
| Scan Speed | Up to 48,000 nm/min |
| Normalization Function | Fluorescence Intensity Normalization |
| Software Modes | Fluorescence Intensity & Luminescence Intensity |
| Data Processing | 1st–4th Derivative Spectra, Peak Detection, Area Integration, Multi-Curve Overlay, Ratio Analysis |
| Quantitative Methods | Calibration Curve (1st–3rd order), Coefficient Method |
| Sample Forms | Liquid, Powder, Thin Film |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory workflows, supports GLP documentation practices |
| Brand | Lengguang Tech. |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Models | F97 / F97PRO / F97XP |
| Price Range | USD 14,000 – 28,000 |
| Dispersive Element | Holographic Grating |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Slit Width (Spectral Bandwidth) | 2.0 nm to 20 nm |
| Resolution | 2.0 nm |
| Sensitivity | S/N > 200 (peak-to-peak, F97XP) |
| Wavelength Accuracy | ±0.4 nm (F97XP), ±1.0 nm (F97PRO) |
| Light Source | 150 W Ozone-Free Xenon Arc Lamp (Hamamatsu, 2000 h lifetime) |
| Brand | Lengguang Tech. |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Wavelength Range (Excitation) | 200–900 nm |
| Wavelength Range (Emission) | 200–900 nm |
| Slit Width (Spectral Bandpass) | 1.0–20.0 nm |
| Spectral Resolution | 1.0 nm |
| Wavelength Accuracy | ±0.4 nm |
| Signal-to-Noise Ratio (Water Raman Peak) | >350:1 (peak-to-peak) |
| Light Source | 150 W Ozone-Free Xenon Arc Lamp (Hamamatsu, 2000 h lifetime) |
| Detector | Hamamatsu R928 Red-Sensitive Photomultiplier Tube (PMT) |
| Optical Design | Horizontal Slit, Dual-Beam Ratio-Monitoring Excitation Path |
| Grating | Imported JY (Jobin Yvon) Blazed Grating |
| Excitation/Emisson Grating Blaze | 300 nm (EX), 400 nm (EM) |
| Linearity (Fluorescence Intensity) | ≥0.995 |
| Scan Speed | Up to 60,000 nm/min |
| Supported Scanning Modes | 3D Fluorescence Mapping, Time-Resolved Emission Scanning, Constant-Wavelength-Difference Synchronous Scanning, Constant-Wavenumber-Difference (Constant Energy Difference) Synchronous Scanning |
| Quantum Yield Measurement | Optional Integrated Accessory |
| Standard Cuvette Volume | 0.5 mL (10 mm pathlength) |
| Brand | Lengguang Tech. |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | F98 |
| Price Range | USD 14,000–28,000 |
| Dispersive Element | Dual Grating Monochromator |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Slit Width (Spectral Bandpass) | 1.0–20.0 nm |
| Spectral Resolution | 1.0 nm |
| Sensitivity | >350:1 (peak-to-peak) |
| Wavelength Accuracy | ±0.4 nm |
| Excitation Source | 150 W Ozone-Free Xenon Lamp (Hamamatsu, Japan) |
| Emission Detection Range | 200–900 nm |
| Excitation Range | 200–900 nm |
| Minimum Sample Volume | 0.5 mL (standard 10 mm cuvette) |
| Optical System | Dual-Beam Ratio-Monitoring with Horizontal Beam Geometry |
| Linearity | R² ≥ 0.995 |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Model | Fluorat-02-Panaroma |
| Wavelength Range (Excitation) | 210–840 nm |
| Wavelength Range (Emission) | 210–690 nm (up to 840 nm optional) |
| Spectral Resolution | <8 nm (15 nm optional) |
| Wavelength Accuracy | <3 nm |
| Signal-to-Noise Ratio | >100 (up to 200) |
| Slit Width (Spectral Bandpass) | 1.5 nm |
| Sensitivity | >200:1 |
| Detector | PMT |
| Light Source | Pulsed Xenon Lamp |
| Cuvette Volume | 0.01–3 mL |
| Dimensions | 400 × 355 × 150 mm |
| Weight | 13 kg |
| Power Supply | 110/220 V, 50/60 Hz, 60 W |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NS1 |
| Pricing | Available Upon Request |
| Brand | Orient KOJI |
|---|---|
| Origin | Tianjin, China |
| Model | Micro-tau |
| Spectral Dispersion | Grating and Filter-Based |
| Instrument Type | Steady-State & Time-Resolved Fluorescence Spectrometer |
| Slit Width (Spectral Bandpass) | 5–20 nm |
| Optical Resolution | 1 nm |
| Sensitivity | 5000:1 (Signal-to-Noise Ratio) |
| Wavelength Accuracy | ±5 nm |
| Excitation Source | Pulsed Laser Diode or DPSS Lasers |
| Fluorescence Lifetime Range | 50 ps – 100 s (Full Temporal Domain) |
| Spatial Resolution | <1 µm |
| Field of View (Imaging Camera) | <0.5 mm |
| Spectral Range (Microspectroscopy) | 360–1100 nm |
| Lifetime Detection Range | 400–1050 nm (Optional Extended IR-II Band) |
| Timing Resolution | ≤1 ps |
| Jitter | <10 ps |
| Counting Rate | >65 MHz per channel |
| Simultaneous Channels | ≥8 |
| Optional Modules | Cryogenic Stage (Liquid Nitrogen), Motorized XYZ Stage (FLIM-Ready), Picosecond Detectors (Wavelength- & Temperature-Tunable), Multi-Laser Combiner (266–1030 nm, up to 4 inputs), Raman Dual-Channel Add-on, Fiber-Coupled Excitation Path |
| Brand | Orient KOJI |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | QY-2000 |
| Price Range | USD 28,000–42,000 |
| Dispersion Unit | Grating + Bandpass Filters |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Slit/Spectral Bandwidth | CCD Detector (Fixed Optical Resolution) |
| Resolution | 1.2 nm |
| Sensitivity | >500:1 (S/N) |
| Wavelength Accuracy | ±0.2 nm |
| Excitation Sources | Tunable Xenon Lamp + Selectable LEDs (254 nm, 395 nm, 450 nm, 460 nm) |
| Detection Range | 250–850 nm |
| Integrating Sphere | PTFE-coated interior, <1% port loss, sample port diameter <8 mm |
| Dynamic Range | 7000:1 |
| PLQY Reproducibility | ±1% (mean deviation) |
| Brand | Orient KOJI |
|---|---|
| Origin | Tianjin, China |
| Model | TAP-02 |
| Instrument Type | Steady-State and Time-Resolved Fluorescence Spectrometer |
| Temperature Range | Ambient to 300°C (573 K) |
| Temperature Control Accuracy | ±0.1°C |
| Temperature Stability | ±0.2°C (40–300°C) |
| Programmable Segments | 8-step ramp/soak |
| Heating Rate | >20°C/min |
| Cooling Design | Active rapid cooling |
| Operating Environment | Ambient pressure with controllable gas flow (N₂, O₂, Ar, etc.) |
| Power Supply | AC 220 V, 5 A, 500 W |
| Compatibility | Modular integration with Hitachi F-4500/F-7000/F-4600/F-2700 |
| Brand | PerkinElmer |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | FL 6500 |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth (Slit Width) | 1, 2.5, 5, 10, 20 nm |
| Resolution | 1.0, 2.5, 5, 10, 20 nm |
| Sensitivity | >750:1 (RMS) |
| Dispersion Element | Grating |
| Light Source | Pulsed Xenon Lamp |
| Brand | PerkinElmer |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | FL 8500 |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth (Slit Width) | 1, 2.5, 5, 10, 20 nm |
| Resolution | 1.0, 2.5, 5, 10, 20 nm |
| Sensitivity | 4000:1 (RMS), 1000:1 (Peak-to-Peak) |
| Dispersion Element | Holographic Grating |
| Excitation Source | Continuous Xenon Arc Lamp |
| Maximum Scan Speed | 60,000 nm/min |
| Footprint | 66 cm (26 in) width |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | LS-55 |
| Pricing | Upon Request |
| Brand | Resonon |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Resonon Bio-LIF Hyperspectral Fluorescence Imaging System |
| Price Range | USD 1,500–1,500,000 (FOB) |
| Spectral Resolution (FWHM) | 1.9 nm |
| Excitation Wavelength | 532 nm |
| Emission Range | 550–1000 nm |
| Spatial Resolution | 60 µm/pixel |
| Image Dimensions | 1600 × 2065 pixels |
| Spectral Bands per Pixel | 335 |
| Scan Time | 25 s |
| SNR (max) | 255 |
| Weight | 28 kg |
| Dimensions | 50 × 70 × 28 cm |
| Power Supply | 120/240 VAC |
| Operating Temperature | +10 to +35 °C |
| Sample Compatibility | 90 mm Ø Petri dishes or standard 96-well microplates (127 × 86 mm) |
| Brand | Ruihai Photonics (Oceanhood) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | PL980 |
| Instrument Type | Steady-State & Time-Resolved Fluorescence Spectrometer |
| Spectral Resolution | ~4 nm @ 25 µm slit |
| Wavelength Accuracy | ≤3% peak-to-peak (@ 2 hrs) |
| Excitation Wavelength | 976 ± 3 nm, Linewidth < 0.2 nm |
| Laser Power Stability | ≤3% P-P (@ 2 hrs) |
| Laser Lifetime | 10,000 hrs |
| Output Power Range | 0–500 mW adjustable |
| Optical Density (OD) of Notch Filter | OD8 |
| Probe Working Distance | 7.5 mm |
| Probe Fiber Length | ~1.5 m |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 5–80% RH |
| Excitation Fiber Core | 105 µm VIS-NIR |
| Emission Collection Fiber Core | 200 µm VIS-NIR |
| Spectral Range | 1000–1700 nm |
| Brand | SCINCO |
|---|---|
| Origin | South Korea |
| Model | Lumilux 5100 |
| Excitation/Emission Spectral Bandwidth | ≤ ±0.5 nm |
| Signal-to-Noise Ratio | > 1000:1 |
| Light Source | 150 W Xenon Arc Lamp |
| Detection Range | 190–900 nm |
| Detector Type | Photomultiplier Tube (PMT) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | RF-6000 |
| Wavelength Accuracy | ±1.0 nm |
| Spectral Bandwidth (Slit Width) | 1.0–20.0 nm |
| Optical Resolution | 1.0 nm |
| Sensitivity (S/N Ratio) | ≥1000:1 (RMS) |
| Wavelength Range | Excitation 200–900 nm, Emission 200–900 nm |
| Scan Speed | Up to 60,000 nm/min |
| Light Source | Long-life Xenon Lamp (2000 h typical lifetime) |
| Detector | Broadband Photomultiplier Tube (PMT), extended to 900 nm |
| Dispersion Element | Dual grating + interference filter system |
| Quantum Yield Measurement | Supported (absolute and relative) |
| Brand | Spectrolight |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | SP-FL |
| Price Range | USD 14,000–28,000 (approx.) |
| Dispersive Element | Grating and Interference Filters |
| Spectral Bandwidth (Slit) | 6–15 nm |
| Resolution | 62,500 (SP-FL-245) / 600,000 (SP-FL-303) / 200,000 (SP-FL-642) |
| Sensitivity | 62,500 (SP-FL-245) / 600,000 (SP-FL-303) / 200,000 (SP-FL-642) |
| Wavelength Accuracy | ±1% of reading |
| Brand | SPL |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | FPB-405 |
| Excitation Wavelength | 405 nm ± 0.5 nm |
| Spectral Bandwidth (Laser Linewidth) | 1 nm FWHM |
| Optical Path | Coaxial Backscattering Configuration |
| Excitation Rejection | OD > 5 at 405 nm |
| Fluorescence Detection Range | 405–850 nm |
| Working Distance | 7.5 mm (standard) |
| Probe Head Dimensions | 120 × 38 × 18 mm (L × W × H) |
| Housing Material | Black Anodized Aluminum |
| Max Operating Temperature | 80 °C |
| Fiber Interface | SMA 905 |
| Compatible Fiber | 400 µm core, NA 0.22 recommended |
| Background Suppression | Eliminates quartz fiber Raman scattering and Rayleigh leakage |
| Brand | SPL |
|---|---|
| Origin | Hong Kong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Mainland China |
| Model | SPL-FL-405 |
| Price | USD 6,950 (FOB HK) |
| Dispersion Element | Holographic Grating + Bandpass Filter |
| Excitation Wavelength | 405 nm (Stabilized Semiconductor Diode Laser) |
| Detection Range | 400–1000 nm |
| Optical Resolution | ~2.5 nm (FWHM) |
| Fiber-Coupled Probe | SMA905, Stainless Steel Housing, UV-Vis Optimized |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Wavelength Dispersion Element | Holographic Grating |
| Slit Width (Spectral Bandpass) | 1.0–20.0 nm |
| Optical Resolution | 0.2 nm |
| Sensitivity | 1200:1 (RMS), 15,000:1 (RMS with Background Subtraction) |
| Wavelength Accuracy | ±2 nm |
| Excitation Source | Pulsed Xenon Arc Lamp |
| PMT Detection Range | Up to 900 nm |
| Maximum Scan Speed | 30,000 nm/min |
| Software | FL Analyst (English & Chinese GUI) |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Wavelength Dispersion Element | Grating |
| Slit Width (Spectral Bandpass) | 1.0–20 nm |
| Optical Resolution | 0.2 nm |
| Sensitivity | >450:1 (Peak-to-Peak) |
| Wavelength Accuracy | ±2.0 nm |
| Excitation Source | Xenon Arc Lamp |
| Standard PMT Range | Up to 900 nm |
| Maximum Scan Speed | 30,000 nm/min |
| Spectral Correction | Full-mode (Excitation/Emission/Spectral Response) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | NanoDrop 3300 |
| Excitation Source | Filter-based LED array |
| Excitation Wavelength Range | 400–750 nm |
| Spectral Resolution | <3 nm FWHM (at Hg 546.1 nm) |
| Wavelength Accuracy | ±1 nm |
| Detection Mode | Full-spectrum fluorescence emission (400–750 nm) |
| Sample Volume | As low as 1 µL |
| Power Supply | USB-powered (no external power adapter required) |
| Cuvette-Free Operation | Yes |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | Lumina |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth (Slit) | 0.5 nm |
| Resolution | 0.5 nm |
| Sensitivity | >4000:1 (at water Raman peak) |
| Wavelength Accuracy | ±0.5 nm |
| Excitation Source | 150 W Xenon Arc Lamp |
| Optical Design | Horizontal Beam Path |
| Monochromator Type | Grating-based, Pre-aligned Modular Monochromator |
| Detector | High-sensitivity PMT with extended red response |
| Brand | Topo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Wavelength Range | Typically 200–900 nm (Xenon Lamp Source) |
| Excitation/Emission Monochromators | Czerny-Turner with Holographic Grating |
| Slit Width (Spectral Bandpass) | 1–20 nm |
| Optical Resolution | ≤1 nm (FWHM at 546.1 nm) |
| Wavelength Accuracy | ±1 nm |
| Sensitivity | >300 P-P, >1200 RMS, >15,000 RMS (Background-Subtracted) |
| Light Source | 150 W Pulsed or Continuous Xenon Arc Lamp |
| Detector | R928P Photomultiplier Tube (PMT) |
| Data Acquisition Modes | Emission Scan, Excitation Scan, Synchronous Scan, Time-Based Intensity Monitoring, 3D Excitation-Emission Matrix (EEM) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | FlashSENS |
| Price | USD 84,000 (FOB Beijing) |
| Dispersive Element | Holographic Grating |
| Slit Width (Spectral Bandpass) | 0.01–3 mm (motorized, programmable) |
| Spectral Resolution | 0.6 nm @ 300 grooves/mm |
| Sensitivity | 0.00024 OD (optical density) |
| Wavelength Accuracy | ±0.8 nm @ 300 grooves/mm |
| Detection Light Source | LDLS-based Supercontinuum White Light (190–2100 nm) |
| Time Resolution | <7 ns (optional ultrafast mode: 3 ns) |
| Sample Compatibility | Solid films, liquid solutions, colloidal suspensions, thin-film devices |
| Measurement Modes | Transient Absorption Kinetics (ΔA vs. t), Transient Absorption Spectra (ΔA vs. λ), Dual-mode (kinetics + spectra) |
| Monochromator | Omni-λ300i, 300 mm focal length |
| Detector Options | Si photodiode (300–1100 nm), InGaAs array (900–1600 nm), ICCD (180–850 nm, gated, -25°C thermoelectric cooling) |
| Pump Laser Compatibility | Nd:YAG harmonics (1064/532/355/266 nm), tunable OPO (210–2400 nm) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Flex One |
| Price | USD 70,000 (approx.) |
| Dispersive Element | Holographic Grating & Interference Filters |
| Slit Width (Spectral Bandpass) | 0.05 nm |
| Optical Resolution | 0.1 nm |
| Wavelength Accuracy | ±0.2 nm |
| Spectral Range | 300–2200 nm (standard configuration) |
| Spatial Resolution | <50 µm |
| Excitation Wavelength Options | 266, 325, 405, 442, 473, 532, 633, 785 nm |
| Detector Options | Cooled Si CCD (2000×256), PMT, Single-Point InGaAs, Cooled InGaAs Array (512×1), or Custom Detector Modules |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Steady-State & Time-Resolved Fluorescence Spectrometer |
| Dispersive Element | Grating + Bandpass Filters |
| Integration Configuration | Glovebox-Compatible Fiber-Coupled Optical Path (Y-Fiber Geometry) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Steady-State & Time-Resolved Fluorescence Spectrometer |
| Dispersive Elements | Holographic Grating + Bandpass/Notch Filters |
| Excitation Sources | CW Laser Diode, Pulsed Laser (ns–ps range), Electrical Probe Station (for e-pumped lasing) |
| Detection Mode | Confocal Micro-Spectroscopy with Back-Illuminated CCD or EMCCD |
| Spatial Resolution | Diffraction-Limited (~300 nm lateral at 532 nm) |
| Spectral Range | 200–1100 nm (configurable) |
| Temporal Resolution | Down to <100 ps (with TCSPC option) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | MiniPL 5.0 eV |
| Excitation Wavelengths | 224 nm (5.5 eV) or 248.6 nm (5.0 eV) |
| Spectral Range (Standard) | 190–650 nm |
| Spectral Range (Optional) | 190–850 nm |
| Resolution (Standard) | 0.2 nm @ 1200 g/mm grating |
| Resolution (Optional) | 0.07 nm @ 3600 g/mm grating |
| Detector | High-sensitivity PMT |
| Signal Processing | Built-in boxcar averager for pulsed signal integration |
| Sample Stage | Manual XYZ adjustment, max. 50 mm diameter |
| Optional | Motorized XY scanning stage for PL mapping |
| Dimensions | 15 × 18 × 36 cm |
| Weight | < 8 kg |
| Software Platform | LabVIEW-based control & spectral analysis suite |