Molecular Fluorescence Spectrometer
Filter
Showing 31–60 of 84 results
| Brand | HORIBA |
|---|---|
| Origin | Canada |
| Model | QuantaMaster 8000 |
| Wavelength Accuracy | ±0.3 nm |
| Spectral Resolution | 0.1 nm |
| Slit Width (Spectral Bandpass) | 0–30 µm |
| Sensitivity | >30,000:1 (Water Raman SNR) |
| Dispersive Element | Grating |
| Pulse Excitation Capability | Up to 100 MHz |
| NIR Phosphorescence Lifetime Range | Up to 5500 nm |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ratio Master |
| Price Range | USD 65,000 – 130,000 (FOB) |
| Monochromator Type | Grating-Based |
| Spectral Bandpass | Adjustable down to <1 nm (typical operational minimum) |
| Wavelength Accuracy | ±0.2 nm (calibrated with Hg/Ne lamp traceable to NIST standards) |
| Detection Speed | Sub-2 ms wavelength switching |
| Temporal Resolution | ≤5 ms per dual-wavelength ratio frame (with optional high-speed PMT or sCMOS detection) |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | Aqualog |
| Dispersion Element | Grating and Filter |
| Slit Width (Spectral Bandpass) | 5 nm |
| Resolution | 0.41 nm/pixel |
| Sensitivity | 20,000:1 (water Raman SNR, RMS, 350 nm excitation, 30 s integration) |
| Wavelength Accuracy | ±1 nm |
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Model | DeltaPro |
| Dispersion Element | Grating |
| Excitation Sources | NanoLED (up to 1 MHz), DeltaDiode (up to 100 MHz), SpectraLED (for phosphorescence, multi-wavelength) |
| Lifetime Range | 25 ps to >1 s |
| Detection Module | PPD photon counting detector (standard), optional NIR extension to ~1700 nm |
| Data Acquisition | Time-Correlated Single Photon Counting (TCSPC) with DeltaHub core (dead time: 10 ns) |
| Software Control | F-Link USB 2.0 interface, no PCI card required |
| Sample Compatibility | Liquid cuvettes (with temperature control & stirring), solid sample holders, large UV-grade sample chamber |
| Optional Accessories | Monochromators, motorized polarizers, automated optical components, PPD-850C/PPD-900C IR modules |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | DynaMyc |
| Detection Principle | Time-Correlated Single Photon Counting (TCSPC) |
| Lifetime Range | 100 ps – 10 µs |
| Spectral Detection Range | 185–650 nm / 300–850 nm (with TBX fast detector) |
| Spatial Resolution | 0.5 µm |
| Scan Stage Travel | 75 × 50 mm |
| Laser Source Options | Pulsed diode lasers (370–980 nm), DeltaDiode series, repetition rate up to 100 MHz, CW/pulsed mode selectable |
| Excitation Filtering | Motorized filter wheel with dichroic mirrors and pinholes (100–1000 µm) |
| Data Acquisition Modes | Single-point, multi-point, FLIM mapping |
| Software | DataStation (instrument control), DAS6 (lifetime decay analysis & deconvolution) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | FluoroCube |
| Price Range | USD 65,000 – 130,000 (FOB) |
| Dispersive Element | Grating |
| Slit Width (Spectral Bandpass) | 1–32 nm |
| Spectral Resolution | 1 nm |
| Sensitivity | >3000:1 (Signal-to-Noise Ratio) |
| Wavelength Accuracy | ±0.05 nm |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | Fluorolog-3 |
| Wavelength Range (Optional) | 185 nm – 14 µm |
| Excitation/Emission Monochromators | Single or Dual Grating |
| Slit Width (Spectral Bandpass) | 0–20 nm |
| Optical Resolution | 0.06 nm |
| Sensitivity | 20,000:1 (Signal-to-Noise Ratio) |
| Wavelength Accuracy | ±0.2 nm |
| Light Source | 450 W Xenon Arc Lamp |
| Detection Method | Photon Counting |
| Data Acquisition | TCSPC (Time-Correlated Single Photon Counting) for Lifetime Measurements |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | FluoroMax-4 |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth (Slit Width) | 0–30 nm |
| Optical Resolution | 0.2 nm |
| Sensitivity | >6000:1 (RMS method reported as up to 16,000:1) |
| Excitation Source | 150 W ozone-free Xenon lamp (vertically mounted) |
| Monochromator Type | Plane grating, Czerny-Turner design |
| Detection Mode | Photon counting |
| Optional Upgrades | TCSPC fluorescence lifetime module, phosphorescence lifetime unit, IR extension, integrating sphere, TIRF, Stop-Flow, polarization, temperature-controlled stages (Peltier & LN₂), microplate reader, microscope coupling |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | Nanolog® |
| Excitation Source | 450 W continuous xenon lamp |
| Wavelength Range | UV–NIR (200–1700 nm, extendable to ~3 µm) |
| Spectral Resolution | 0.06 nm |
| Slit Width (Spectral Bandpass) | 0–20 nm |
| Wavelength Accuracy | ±0.2 nm |
| Sensitivity | >20,000:1 (at 1,550 nm, using liquid-nitrogen-cooled InGaAs array) |
| Detection Modes | Steady-state, time-resolved (TCSPC), and combined steady-state/time-resolved spectroscopy |
| Detector Options | PMT (UV–NIR), Symphony II InGaAs array (800–1700 nm |
| Lifetime Range | Fluorescence 100 ps–1 ms |
| Software | NanoSizer® for SWNT characterization (diameter distribution, FRET analysis), FluoroLog®-based acquisition and analysis suite |
| Compliance | Fully compatible with GLP/GMP data integrity requirements |
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Model | Tempro |
| Excitation Source | Pulsed LED/Laser Diodes (255–NIR) |
| Detection Range | 185–650 nm (upgradable to 850 nm or 1700 nm with optional NIR detectors) |
| Lifetime Range | 100 ps to 1 s |
| Detection Method | Time-Correlated Single Photon Counting (TCSPC) |
| Wavelength Selection | Filter-based (monochromator optional) |
| Detector Type | PPD (Photon-Counting Photodiode) Module |
| Software | Horiba FluoroLog®-3 compatible analysis suite |
| Compliance | Designed for GLP/GMP environments |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Import Status | Imported |
| Model | InverTau |
| Pricing | Upon Request |
| Dispersive Element | Filter-Based |
| Resolution | 4096 × 4096 |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Model | FP-8000 Series |
| Wavelength Range | 200–750 nm (up to 900 nm or 1010 nm depending on model) |
| Excitation Source | 150 W Xenon Arc Lamp |
| Spectral Bandwidth (Slit) | 1–20 nm |
| Resolution | 1.0 nm |
| Wavelength Accuracy | ±1.0 nm |
| Sensitivity (S/N) | >500 (RMS, specified at water Raman peak) |
| Scan Speed | Up to 60,000 nm/min |
| Dynamic Range | >6.5 decades |
| Detection Capability | Phosphorescence lifetime down to 1 ms |
| Dispersion Element | Grating + Order-sorting Filters |
| Accessories Interface | IQ-enabled automatic accessory recognition |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | FluidMaster-Multi Phase |
| Wavelength Accuracy | ±2.0 nm |
| Spectral Bandwidth (Slit) | 1.5–20 nm |
| Optical Resolution | 1.0 nm |
| Sensitivity | 1% |
| Dispersive Elements | Grating and Interference Filters |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FluidMaster-Thermal |
| Dispersion Unit | Grating and Interference Filters |
| Slit Width (Spectral Bandpass) | 1.5 nm – 20 nm |
| Spectral Resolution | 1.0 nm |
| Sensitivity | 1% |
| Wavelength Accuracy | ±2.0 nm |
| Brand | LDI |
|---|---|
| Origin | Imported (Non-Chinese) |
| Manufacturer Status | Authorized Distributor |
| Instrument Type | Steady-State & Time-Resolved Fluorescence Spectrometer |
| Excitation/Emission Dispersion | Grating + Filter-Based Monochromators |
| Light Source | 10 W Xenon Arc Lamp (≈100,000 SFS acquisitions lifetime) |
| Excitation Range | 220–660 nm |
| Emission Range | 200–750 nm |
| Detector | Photomultiplier Tube (PMT) with Reference & Signal Photodiodes |
| Sample Compartment | Standard 12.5 × 12.5 × 45 mm Quartz Cuvette |
| Data Interface | USB |
| Power Supply | 12 VDC (AC Adapter: 100–240 V, 50–60 Hz) |
| Power Consumption | 20 W |
| Dimensions | 15 × 24 × 40 cm |
| Weight | 11 kg |
| Operating Temperature | 10–40 °C |
| Measurement Cycle | 2 min per scan |
| Detection Limits | Crude Oil (Heavy/Medium: 0.5 mg/L |
| Light | 0.3 mg/L), Kerosene (0.1 mg/L), Diesel/Gasoline/Lubricants (0.2–0.5 mg/L), Phenol (0.01 mg/L), Naphthalene (5 µg/L), Anthracene/Benzo[a]pyrene (1 µg/L), Chlorophyll-a (1 µg/L) |
| Compliance | Designed for ASTM D5869, ISO 10603, USP <1058>, and GLP/GMP-aligned data integrity workflows (audit trail, electronic signatures, 21 CFR Part 11–compatible software architecture) |
| Brand | Lengguang Tech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | F93 |
| Price Range | USD 1,400 – 7,000 |
| Dispersive Element | Holographic Grating |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Slit Width (Spectral Bandpass) | 12 nm |
| Spectral Resolution | 12 nm |
| Sensitivity | ≤1 × 10⁻⁹ mol/L (Quinine Sulfate in 0.1 M H₂SO₄) |
| Wavelength Accuracy | ±2.0 nm |
| Excitation Source | High-Stability LED |
| Brand | Lengguang Tech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Model | F96Pro |
| Wavelength Range (Excitation) | 200–850 nm |
| Wavelength Range (Emission) | 200–900 nm |
| Excitation Source | 150 W Ozone-Free Xenon Lamp (Hamamatsu, 2000 h lifetime) |
| Monochromator | Czerny-Turner grating monochromator with interference filters |
| Slit Width (Spectral Bandpass) | 10 nm |
| Spectral Resolution | 10 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | ≤0.5 nm |
| Sensitivity (S/N) | >150:1 (at water Raman peak, 350 nm excitation) |
| Scan Speed | Up to 48,000 nm/min (10-point resolution) |
| Linearity (R²) | ≥0.995 |
| Standard Excitation Filter | 365 nm interference filter |
| Software | Quantitative & qualitative analysis suite with derivative spectroscopy (1st–4th order), multi-curve overlay, kinetic time-scan, spectral math, peak integration, and calibration curve fitting (linear, quadratic, cubic) |
| Brand | Lengguang Tech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Model | F96S |
| Dispersion Element | Holographic Grating |
| Slit Width (Spectral Bandwidth) | 10 nm |
| Spectral Resolution | 10 nm |
| Sensitivity | >90:1 (Water Raman SNR) |
| Wavelength Accuracy | ±1.0 nm |
| Excitation Wavelength Range | 250–600 nm (LED-based) |
| Emission Wavelength Range | 200–650 nm |
| Emission Wavelength Repeatability | ≤0.5 nm |
| Standard Excitation Sources | 365 nm, 376 nm, 392 nm, 405 nm LEDs |
| Scan Speed | Up to 48,000 nm/min |
| Normalization Function | Fluorescence Intensity Normalization |
| Software Modes | Fluorescence Intensity & Luminescence Intensity |
| Data Processing | 1st–4th Derivative Spectra, Peak Detection, Area Integration, Multi-Curve Overlay, Ratio Analysis |
| Quantitative Methods | Calibration Curve (1st–3rd order), Coefficient Method |
| Sample Forms | Liquid, Powder, Thin Film |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory workflows, supports GLP documentation practices |
| Brand | Lengguang Tech. |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Models | F97 / F97PRO / F97XP |
| Price Range | USD 14,000 – 28,000 |
| Dispersive Element | Holographic Grating |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Slit Width (Spectral Bandwidth) | 2.0 nm to 20 nm |
| Resolution | 2.0 nm |
| Sensitivity | S/N > 200 (peak-to-peak, F97XP) |
| Wavelength Accuracy | ±0.4 nm (F97XP), ±1.0 nm (F97PRO) |
| Light Source | 150 W Ozone-Free Xenon Arc Lamp (Hamamatsu, 2000 h lifetime) |
| Brand | Lengguang Tech. |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Wavelength Range (Excitation) | 200–900 nm |
| Wavelength Range (Emission) | 200–900 nm |
| Slit Width (Spectral Bandpass) | 1.0–20.0 nm |
| Spectral Resolution | 1.0 nm |
| Wavelength Accuracy | ±0.4 nm |
| Signal-to-Noise Ratio (Water Raman Peak) | >350:1 (peak-to-peak) |
| Light Source | 150 W Ozone-Free Xenon Arc Lamp (Hamamatsu, 2000 h lifetime) |
| Detector | Hamamatsu R928 Red-Sensitive Photomultiplier Tube (PMT) |
| Optical Design | Horizontal Slit, Dual-Beam Ratio-Monitoring Excitation Path |
| Grating | Imported JY (Jobin Yvon) Blazed Grating |
| Excitation/Emisson Grating Blaze | 300 nm (EX), 400 nm (EM) |
| Linearity (Fluorescence Intensity) | ≥0.995 |
| Scan Speed | Up to 60,000 nm/min |
| Supported Scanning Modes | 3D Fluorescence Mapping, Time-Resolved Emission Scanning, Constant-Wavelength-Difference Synchronous Scanning, Constant-Wavenumber-Difference (Constant Energy Difference) Synchronous Scanning |
| Quantum Yield Measurement | Optional Integrated Accessory |
| Standard Cuvette Volume | 0.5 mL (10 mm pathlength) |
| Brand | Lengguang Tech. |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | F98 |
| Price Range | USD 14,000–28,000 |
| Dispersive Element | Dual Grating Monochromator |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Slit Width (Spectral Bandpass) | 1.0–20.0 nm |
| Spectral Resolution | 1.0 nm |
| Sensitivity | >350:1 (peak-to-peak) |
| Wavelength Accuracy | ±0.4 nm |
| Excitation Source | 150 W Ozone-Free Xenon Lamp (Hamamatsu, Japan) |
| Emission Detection Range | 200–900 nm |
| Excitation Range | 200–900 nm |
| Minimum Sample Volume | 0.5 mL (standard 10 mm cuvette) |
| Optical System | Dual-Beam Ratio-Monitoring with Horizontal Beam Geometry |
| Linearity | R² ≥ 0.995 |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Model | Fluorat-02-Panaroma |
| Wavelength Range (Excitation) | 210–840 nm |
| Wavelength Range (Emission) | 210–690 nm (up to 840 nm optional) |
| Spectral Resolution | <8 nm (15 nm optional) |
| Wavelength Accuracy | <3 nm |
| Signal-to-Noise Ratio | >100 (up to 200) |
| Slit Width (Spectral Bandpass) | 1.5 nm |
| Sensitivity | >200:1 |
| Detector | PMT |
| Light Source | Pulsed Xenon Lamp |
| Cuvette Volume | 0.01–3 mL |
| Dimensions | 400 × 355 × 150 mm |
| Weight | 13 kg |
| Power Supply | 110/220 V, 50/60 Hz, 60 W |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NS1 |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | FL 6500 |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth (Slit Width) | 1, 2.5, 5, 10, 20 nm |
| Resolution | 1.0, 2.5, 5, 10, 20 nm |
| Sensitivity | >750:1 (RMS) |
| Dispersion Element | Grating |
| Light Source | Pulsed Xenon Lamp |
| Brand | PerkinElmer |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | FL 8500 |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth (Slit Width) | 1, 2.5, 5, 10, 20 nm |
| Resolution | 1.0, 2.5, 5, 10, 20 nm |
| Sensitivity | 4000:1 (RMS), 1000:1 (Peak-to-Peak) |
| Dispersion Element | Holographic Grating |
| Excitation Source | Continuous Xenon Arc Lamp |
| Maximum Scan Speed | 60,000 nm/min |
| Footprint | 66 cm (26 in) width |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | LS-55 |
| Pricing | Upon Request |
| Brand | Resonon |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Resonon Bio-LIF Hyperspectral Fluorescence Imaging System |
| Price Range | USD 1,500–1,500,000 (FOB) |
| Spectral Resolution (FWHM) | 1.9 nm |
| Excitation Wavelength | 532 nm |
| Emission Range | 550–1000 nm |
| Spatial Resolution | 60 µm/pixel |
| Image Dimensions | 1600 × 2065 pixels |
| Spectral Bands per Pixel | 335 |
| Scan Time | 25 s |
| SNR (max) | 255 |
| Weight | 28 kg |
| Dimensions | 50 × 70 × 28 cm |
| Power Supply | 120/240 VAC |
| Operating Temperature | +10 to +35 °C |
| Sample Compatibility | 90 mm Ø Petri dishes or standard 96-well microplates (127 × 86 mm) |
| Brand | Ruihai Photonics (Oceanhood) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | PL980 |
| Instrument Type | Steady-State & Time-Resolved Fluorescence Spectrometer |
| Spectral Resolution | ~4 nm @ 25 µm slit |
| Wavelength Accuracy | ≤3% peak-to-peak (@ 2 hrs) |
| Excitation Wavelength | 976 ± 3 nm, Linewidth < 0.2 nm |
| Laser Power Stability | ≤3% P-P (@ 2 hrs) |
| Laser Lifetime | 10,000 hrs |
| Output Power Range | 0–500 mW adjustable |
| Optical Density (OD) of Notch Filter | OD8 |
| Probe Working Distance | 7.5 mm |
| Probe Fiber Length | ~1.5 m |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 5–80% RH |
| Excitation Fiber Core | 105 µm VIS-NIR |
| Emission Collection Fiber Core | 200 µm VIS-NIR |
| Spectral Range | 1000–1700 nm |
| Brand | SCINCO |
|---|---|
| Origin | South Korea |
| Model | Lumilux 5100 |
| Excitation/Emission Spectral Bandwidth | ≤ ±0.5 nm |
| Signal-to-Noise Ratio | > 1000:1 |
| Light Source | 150 W Xenon Arc Lamp |
| Detection Range | 190–900 nm |
| Detector Type | Photomultiplier Tube (PMT) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | RF-6000 |
| Wavelength Accuracy | ±1.0 nm |
| Spectral Bandwidth (Slit Width) | 1.0–20.0 nm |
| Optical Resolution | 1.0 nm |
| Sensitivity (S/N Ratio) | ≥1000:1 (RMS) |
| Wavelength Range | Excitation 200–900 nm, Emission 200–900 nm |
| Scan Speed | Up to 60,000 nm/min |
| Light Source | Long-life Xenon Lamp (2000 h typical lifetime) |
| Detector | Broadband Photomultiplier Tube (PMT), extended to 900 nm |
| Dispersion Element | Dual grating + interference filter system |
| Quantum Yield Measurement | Supported (absolute and relative) |