Multicomponent Gas Analyzer
Filter
Showing 121–143 of 143 results
| Brand | SDL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Online Continuous Emission Monitoring System (CEMS) |
| Model | MODEL 1080 |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption Spectroscopy |
| Response Time | ≤30 s (T90) |
| Repeatability | ≤±1% FS (for CO, CO₂, CH₄, SO₂, NO) |
| Output Interfaces | 4–20 mA analog outputs (up to 8 channels), relay contact outputs (6 configurable), RS-485/Modbus RTU, optional Ethernet |
| Calibration | Automatic zero/span calibration with built-in reference cell or external gas cylinder |
| Display | 5.7″ TFT LCD with bilingual (Chinese/English) menu interface |
| Warm-up Time | ≤5 min |
| Enclosure Rating | IP65 (standard) |
| Compliance | Meets HJ 76-2017, HJ 1013-2018 (China EPA CEMS Technical Specifications), CE marked for industrial environments |
| Brand | Servomex |
|---|---|
| Origin | United Kingdom |
| Model | 5100 i.s |
| Type | Portable Multicomponent Gas Analyzer |
| Certification | ATEX Ex II 1G Ex ia IIC T4, IECEx Ex ia IIC T4 |
| Protection Rating | IP65 |
| Measurement Principles | Paramagnetic (O₂), Single-Beam Single-Wavelength NDIR (CO₂) |
| Response Time | <15 s (T₉₀) |
| Repeatability | ±0.1% vol O₂, ±0.2% vol CO₂ |
| Operating Temperature | −20 °C to +50 °C |
| Battery Life | Up to 12 h (Li-ion rechargeable) |
| Data Storage | 200 measurement records |
| Display | Backlit monochrome LCD |
| Optional Accessories | Integrated sample pump, sampling probe, soft carry case, shoulder strap |
| Brand | Servomex |
|---|---|
| Origin | United Kingdom |
| Model | 5200 Multipurpose |
| Type | Portable Multicomponent Gas Analyzer |
| Measurement Principle | Paramagnetic (O₂) + NDIR (CO, CO₂, CH₄) |
| Response Time | <15 s (typical for O₂, CO, CO₂) |
| Repeatability | ±0.1% of full scale (for O₂ with high-accuracy sensor) |
| Power Options | AC 100–240 V, DC 12/24 V (vehicle), or rechargeable Li-ion battery (8–36 h runtime, sensor- and pump-dependent) |
| Output Interfaces | RS-232, 4–20 mA (optional), backlit LCD display |
| Data Logging | 200-point internal memory |
| Compliance | USP <91> for Medical Oxygen, NF for Nitrogen, FDA 21 CFR Part 11–ready software architecture (audit trail & user access control enabled) |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Online Fixed-Mount Analyzer |
| Model | NSA-3080A |
| Measurement Principle | Non-Dispersive Infrared (NDIR) + Electrochemical (EC) + Paramagnetic (O₂) |
| Gas Components | SO₂, NOₓ, CO, CO₂, O₂ (up to 5 simultaneously) |
| Detection Ranges | NOₓ (100–2500 ppm), SO₂ (100–5000 ppm), CO (100 ppm–1 vol%), CO₂ (5–20 vol%), O₂ (0–25 vol%) |
| Calibration | Automated hourly or weekly zero/span correction |
| Operating Ambient Temperature | −5 to 40 °C |
| Power Supply | AC 220 V ±10%, 50 Hz, ~700 VA |
| Data Storage | Removable SD card interface |
| Compliance | Designed for continuous emissions monitoring (CEMS) per Chinese HJ 75/76 standards |
| Brand | SIELINS |
|---|---|
| Model | XLZ-1090 |
| Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Configuration | Online Fixed-Mount Analyzer |
| Response Time | T90 ≤ 15 s |
| Repeatability | ≤ 1% FS |
| Stability | Drift ≤ ±1% FS / 15 days |
| Linearity Error | ≤ ±1% FS |
| Gas Flow Rate | 0.5–3 L/min |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤ 90% RH |
| Power Supply | 220 V ±10%, 50 Hz ±0.5 Hz, 150 W |
| Simultaneous Measurement Channels | Up to 4 gases |
| Measured Gases | CO, CO₂, SO₂, CH₄, NH₃ (configurable per application) |
| Brand | SIELINS |
|---|---|
| Origin | Beijing, China |
| Model | XLZ-1090GXH |
| Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Type | Online Fixed-Mount Gas Analyzer |
| Response Time (T90) | ≤15 s |
| Repeatability | ≤1% FS |
| Zero Drift | ≤±1% FS / 48 h |
| Span Drift | ≤±1% FS / 48 h |
| Linearity Error | ≤±1% FS |
| Detection Range | 0–50 ppm to 0–100% v/v (configurable) |
| Resolution | 1 ppm (trace), 0.01% v/v (major) |
| Sample Flow Rate | 0.5–3 L/min |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤90% RH |
| Power Supply | 220 V ±10%, 50 ±0.5 Hz, 150 W |
| Output Signals | 4–20 mA, 0–20 mA, 0–10 mV, 1–5 V (load ≤600 Ω) |
| Display | Digital LCD with real-time concentration readout |
| Brand | SIELINS |
|---|---|
| Model | XLZ-1090GXH |
| Origin | Beijing, China |
| Instrument Principle | Non-Dispersive Infrared (NDIR) Absorption Spectroscopy |
| Configuration | Online Fixed-Mount Analyzer |
| Response Time | ≤20 s |
| Repeatability | ≤0.5% FS |
| Zero Drift | ±1% FS |
| Span Drift | ±1% FS |
| Linearity Error | ±1% FS |
| Measurement Ranges | CO (0–30 ppm), CO₂ (0–30 ppm), CH₄ (0–300 ppm), SO₂, NH₃ (configurable per gas) |
| Output Signals | Isolated 4–20 mA (default, load ≤400 Ω) and 1–5 V (default, load ≥250 Ω) |
| Power Supply | (220 ± 22) VAC, (50 ± 0.5) Hz |
| Power Consumption | <100 W |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤80% RH |
| Enclosure | 19″ rack-mount chassis (standard depth), IP20-rated |
| Weight | ~15 kg |
| Compliance | Designed for continuous emission monitoring (CEM), process safety integrity level (SIL)-aware deployment, and GLP/GMP-aligned data handling |
| Brand | SIGAS |
|---|---|
| Model | S-ANALYZER ATEX V5.0 |
| Type | Online Industrial Explosion-Proof Multicomponent Gas Analyzer |
| Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Channels | Up to 5 simultaneous gas measurements |
| Response Time | <25 s (t90 @ 60 L/h constant flow) |
| Repeatability | CH₄, CO, CO₂, O₂, and other supported gases |
| Enclosure Rating | Ex d IIC T6 Gb (certified per GB3836.1–2010 & GB3836.2–2010, NEPSI certified) |
| Operating Temperature | 5–45 °C |
| Inlet Flow Rate | 0.4–0.8 L/min (±0.02 L/min stability) |
| Power Supply | (198–242) V AC, 50/60 Hz, <125 W |
| Weight | ~50 kg |
| Dimensions | Not specified in input |
| Analog Output | 4–20 mA (2 mA fault signal), load: 250–350 Ω |
| Relay Outputs | 6 configurable dry-contact relays (1 A @ 250 V AC / 2 A resistive) |
| Gas Inlet | NPT 1/8″ female |
| Moisture Requirement | Non-condensing |
| Particulate Limit | ≤100 µg/m³, ≤1 µm |
| Zero Gas | 99.999% N₂ |
| Span Gas Range | 75–125% of full scale |
| Mid-point Calibration Gas | 37.5–62.5% of full scale |
| Ingress Protection | Not explicitly stated |
| Compliance | GB3836.1/2–2010, NEPSI-certified, suitable for Zone 1/21 hazardous areas |
| Brand | SIGAS |
|---|---|
| Origin | Jiangsu, China |
| Model | SPTr-GAS®300 Tracer |
| Type | Portable |
| Response Time | <20 s |
| Repeatability | ±0.1% FS for NH₃, CH₃Br, SO₂, etc. |
| Operating Temperature | 50 °C (thermostatically stabilized) |
| Detection Principle | Photoacoustic Spectroscopy (PAS) |
| Dimensions | 483 mm × 390 mm × 177 mm (19″ 1/2-rack form factor) |
| Weight | ~15 kg |
| Enclosure Rating | IP42 |
| Power Supply | 198–242 V AC, 50/60 Hz |
| Analog Output | 4–20 mA (250–350 Ω load) |
| Communication | RS223 (7-pin blue/black cable) |
| Preheat Time | ~30 min |
| Resolution | 0.1 ppm (typical, gas-dependent) |
| Zero Calibration | Auto or manual air-based calibration |
| Brand | Signal |
|---|---|
| Origin | UK |
| Model | PULSAR-01 |
| Type | Portable |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Response Time | < 2 s |
| Gas Species | O₂, CO, CO₂, CH₄, NO, N₂O, SO₂, HCl |
| Repeatability | High (per ISO 12039 and EN 15267-3 certified performance) |
| Compliance | CE-marked, RoHS-compliant, designed for EPA Method 10/18 and EN 14181 QAL1/QAL2 environments |
| Software Interface | S4i Remote Monitoring & Diagnostics Platform |
| Calibration | Multi-range, user-selectable, auto-calibration with relay-controlled gas switching |
| Display | Optional integrated touchscreen with USB/SD data logging |
| Brand | SIGNAL |
|---|---|
| Origin | United Kingdom |
| Model | S4-PULSAR |
| Principle | Non-Dispersive Infrared (NDIR) with Gas Filter Correlation (GFC) |
| Type | Online Fixed-Mount Analyzer |
| Response Time | Gas- and concentration-dependent (typically < 15 s for major components) |
| Repeatability | ±0.5 ppm or ±1% of full scale (whichever is greater) for CO, CO₂, NO, SO₂, N₂O, CH₄, HCl, O₂ |
| Linearity | Better than ±1% FS |
| Display | 5.7″ color TFT touchscreen |
| Data Storage | Integrated SD card logging (all channels, timestamped) |
| Connectivity | USB host/device port |
| Software | Free PC-based data acquisition and configuration suite included |
| Compliance | Designed for continuous emissions monitoring (CEM) and laboratory-grade trace gas analysis |
| Sample Compatibility | Dry or humidified gas streams |
| Brand | AZ (Beijing Aozuo) |
|---|---|
| Origin | Beijing, China |
| Manufacturer | AZ Instrument Co., Ltd. |
| Model | SoilGAS |
| Instrument Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Configuration | Online, Automated Chamber-Based System |
| Measured Gases | CO₂, CH₄, N₂O, H₂O |
| Repeatability | ≤0.15 ppm (CO₂), ≤10 ppb (CH₄), ≤10 ppb (N₂O), ≤1 ppm (H₂O) |
| Chamber Options | iChamber-S120 (Ø1.2 m × 2.0 m), iChamber-S62 (Ø0.62 m × 1.1 m), iChamber-S35 (Ø0.35 m × 0.5 m) |
| Optical Transmittance | >92% (UV-Vis-NIR range) |
| Height Adjustment | Motorized, continuous, plant-height adaptive (0.5–2.0 m) |
| Compliance | ASTM D6584, ISO 14064-3, IPCC Tier 2/3 methodology support, GLP-aligned data traceability |
| Brand | SRS (Stanford Research Systems) |
|---|---|
| Origin | USA |
| Model | BGA244 |
| Principle | Non-dispersive Infrared (NDIR) Absorption |
| Form Factor | Portable |
| Response Time | <5 s |
| Repeatability | ±0.1% of full scale |
| Measurement Frequency | 4 Hz |
| Interface Options | USB, RS-232, RS-422 |
| Display | Capacitive Touchscreen |
| Software | BGAMon Data Acquisition & Control Suite |
| Compliance | CE, RoHS, NIST-traceable calibration support |
| Brand | SRS (Stanford Research Systems) |
|---|---|
| Origin | USA |
| Model | UGA Series |
| Type | Portable Residual Gas Analyzer |
| Mass Range Options | 100 amu / 200 amu / 300 amu |
| Resolution | Better than 0.5 amu (at 10% peak height) |
| Detection Limit | <1 ppm |
| Operating Pressure Range | 1×10⁻⁶ Torr to 760 Torr (via configurable inlet) |
| Inlet Configurations | Stainless-steel capillary (1–760 Torr), tubular channel (10⁻¹–10⁻⁴ Torr), 2.75" CF flange (<10⁻⁴ Torr) |
| Flow Rate | 1–10 sccm (at STP) |
| Detector | Faraday Cup & Electron Multiplier |
| Vacuum Pumping System | Integrated Turbo-Molecular Pump + Low-Pressure Diaphragm Pump |
| Interface | GPIB, RS-232 |
| Software | Windows-based RGA Control Suite with Real-Time Spectral Acquisition, Leak Detection Mode, Time-Pressure Plotting, and Multicomponent Quantitative Analysis |
| Brand | SRS/Stanford Research Systems |
|---|---|
| Origin | USA |
| Model | PG108 |
| Type | Portable Vacuum Measurement System |
| Operating Temperature | Up to 150 °C |
| Sealing | All-metal construction with copper knife-edge gasket |
| Pressure Range | 1 × 10⁻⁸ Torr to 1000 Torr (dependent on ion gauge configuration) |
| Controller Compatibility | Fully compatible with SRS IGC100 Intelligent Gauge Controller |
| Filament Options | ThO₂/Ir or tungsten, single- or dual-filament |
| Ion Gauge Types Supported | Glass-envelope, metal-envelope, and ultra-high-vacuum (UHV)-rated Bayard-Alpert gauges |
| Compliance | Designed for integration into GLP/GMP-compliant vacuum systems requiring traceable, stable pressure monitoring |
| Brand | SRS/Stanford Research Systems |
|---|---|
| Origin | USA |
| Model | RGA |
| Mass Range | 100 amu / 200 amu / 300 amu |
| Resolution | < 0.5 amu |
| Dynamic Range | 6 decades |
| Detection Limit | 5 × 10⁻¹⁴ Torr (with EM detector) |
| Sensitivity | 2 × 10⁴ A/Torr (FC), >200 A/Torr (EM) |
| Operating Pressure Range | 10⁻⁴ Torr to UHV (FC) |
| Max. Probe Temperature | 300 °C (without ECU) |
| Max. ECU Temperature | 70 °C |
| Detector Options | Faraday Cup (standard), Electron Multiplier (optional) |
| Interface | RS-232 |
| Software | Real-time RGA Windows & LabVIEW drivers |
| Replaceable Components | Filament and electron multiplier in situ |
| Brand | TH-analyzer |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | THA100NO |
| Instrument Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Type | Online Fixed-Mount Analyzer |
| Response Time (T90) | ≤25 s |
| Repeatability | ±1% FS |
| Measurement Range (NO) | 0–500 mg/m³ or 0–50% vol |
| Operating Temperature | 5–45 °C |
| Zero/Full-Scale Stability | ±2% FS / 7 days |
| Linearity Error | ±2% FS |
| Temperature Drift | ±2% FS (5–45 °C) |
| Interference Error | ±2% FS |
| Pressure Compensation | Yes |
| Output | 4–20 mA analog, 8 isolated relay outputs |
| Display | Color LCD with capacitive touch interface |
| Multi-Gas Capability | Up to 3 components (e.g., NO + optional O₂ + one additional IR-active gas) |
| Optical Core | MEMS-based pulsed infrared source, dual-channel pyroelectric detector |
| Environmental Compliance | Designed for continuous operation in industrial CEMS and laboratory-grade monitoring environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | APIX |
| Detection Range | 1–300 AMU |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Online Multicomponent Gas Analyzer |
| Model | TP203 |
| Detection Principle | Temperature-Compensated Thermal Conductivity Detection (TCD) |
| Response Time | ≤120 s |
| Repeatability | ±0.1% (within 90–100% SF₆ range) |
| Measurement Range | 0–100% SF₆ by volume |
| Resolution | 0.01% |
| Sampling Flow Rate | 0.5–0.6 L/min |
| Operating Temperature | −10 to +50 °C |
| Power Supply | Internal Li-ion battery (6600 mAh), ≤50 W |
| Battery Life | ≥8 h |
| Charging Time | ≥4 h (intelligent charge protection) |
| Dimensions | 310 × 290 × 280 mm |
| Weight | ~4 kg |
| Display | High-resolution true-color TFT touchscreen |
| Data Storage | Up to 100 records |
| Interface | Standard USB port for data export to USB drive |
| Environmental Monitoring Compliance | Designed for IEC 62271-1, IEEE C37.122.1, and DL/T 917–2017 SF₆ gas quality monitoring applications |
| Brand | TimePower |
|---|---|
| Model | TP207 |
| Type | Online Multicomponent SF₆ Gas Analyzer |
| Origin | Beijing, China |
| Manufacturer | TimePower (Domestic Producer) |
| Measurement Principles | Electrochemical (SO₂, H₂S, CO), Semiconductor/NDIR (HF, optional), Capacitive Dew Point & Thermal Conductivity (SF₆ Purity) |
| Flow Rate | ~900 mL/min |
| Repeatability | ±2% FS for SO₂, H₂S, CO |
| Detection Ranges | SO₂: 0–100 µL/L |
| H₂S | 0–100 µL/L |
| CO | 0–1000 µL/L |
| HF (optional) | 0–10 µL/L |
| SF₆ Purity | 0–100% vol |
| Dew Point | –80 to +20°C |
| Operating Pressure | <1 MPa |
| Display | 800×480 TFT capacitive touchscreen |
| Data Output | USB 2.0 interface |
| Storage Capacity | 1000 records |
| Power Supply | Rechargeable Li-ion battery + AC/DC adapter |
| Dimensions | 400 × 370 × 180 mm |
| Weight | ~8 kg |
| Operating Environment | –20 to +50°C, <80% RH |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | TOF2000 |
| Instrument Principle | Single-Photon Ionization Time-of-Flight Mass Spectrometry (SPI-TOF-MS) |
| Configuration | Online Fixed/Mobile Deployment |
| Response Time | Sub-second (≤1 s) |
| Analyte Capacity | >300 Atmospheric Volatile Organic Compounds (VOCs) |
| Mass Resolution | >2000 FWHM (Toluene) |
| Linear Dynamic Range | 4 orders of magnitude |
| Vacuum System | Turbo-molecular pump cascade (3-stage) + backing mechanical pump |
| Ionization Source | 10.8 eV VUV lamp (soft ionization) |
| Mass Analyzer | Orthogonal acceleration reflectron TOF with second-order spatial and energy focusing |
| Detection Mode | Direct ambient sampling, no pre-concentration or chromatographic separation required |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | VM1750 |
| Instrument Principle | Cryogenic Preconcentration Coupled with Gas Chromatography–Mass Spectrometry (GC-MS) |
| Configuration | Online Continuous Monitoring System |
| Response Time | ≤5 s (T90) |
| Target Analytes | 116 VOCs including PAMS, TO-14/TO-15 compounds, and C1–C10 aldehydes & ketones |
| Detection Capability | Sub-ppt (pg/m³) level quantification |
| Detector Configuration | Dual-channel detection via Flame Ionization Detector (FID) and Quadrupole Mass Spectrometer (MS) |
| Sample Introduction | Automated, unattended, real-time ambient air sampling |
| Surface Treatment | Fully passivated gas pathways (SilcoNert® or equivalent inert coating) |
| Compliance Readiness | Designed to support EPA Method TO-14A, TO-15, ASTM D5504, and ISO 16017-1 workflows |
| Brand | Wisdom Optics |
|---|---|
| Origin | Beijing, China |
| Model | GGA-313 |
| Detection Principle | Mid-Infrared Cavity Ring-Down Spectroscopy (CRDS) |
| Configuration | Online Continuous Monitoring System |
| Response Time | <1 s (t₉₀) |
| Repeatability | ±0.2 ppm CO₂, ±0.2 ppb N₂O, ±300 ppm H₂O (1σ, 1 s) |
| Drift | ≤2 ppm CO₂, ≤2 ppb N₂O over 24 h |
| Linear Range | 0–2000 ppm CO₂, 0–10 ppm N₂O, 0–3% H₂O |
| Sample Flow Rate | ~200 sccm |
| Operating Temperature | 0–45 °C |
| Power Consumption | 70 W (startup/heating), 45 W (steady-state) |
| Input Voltage | 200–240 VAC, 50/60 Hz |
| Dimensions (W×D×H) | 530 × 430 × 225 mm |
| Weight | 15 kg |
| Inlet/Outlet Fitting | 1/4″ Swagelok® |
| Communication Interfaces | RS-232, USB |