BrandHywell
ModelMHJ-98
Instrument TypeMicrowave Power Density Meter (Radiation Dosimetry Grade)
Measurement PrincipleBroadband RF Field Detection via Calibrated Diode-Based Sensor
Frequency Range0.9–3 GHz
Power Density Range0.01–9.99 mW/cm²
Accuracy (Full Scale)±1.5%
Calibration Uncertainty±0.75 dB
Operating Environment−10 °C to +40 °C, RH 51–81%, Light-Shielded Sensor
DisplayLED Digital, 3½-digit Resolution
Alarm OutputConfigurable Threshold, Audible + Visual + Dry Contact Switch (DC 24 V / 1 A max)
Dimensions100 × 210 × 35 mm
Weight0.5 kg
ComplianceDesigned for IEC 61326-1 (EMC), IEC 61000-4 Series Immunity Testing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHyeyan
ModelMHJ-99
Instrument TypeRF Power Density Meter (Metering/Dose Rate)
Frequency Range0.9–12.4 GHz
Measurement Range0.2 µW/cm² to 20 mW/cm²
DisplayLED Digital, 3.5-digit
Accuracy (Full Scale)±1.5%
Calibration Field Uncertainty±0.75 dB
Operating ModesContinuous Wave (CW) and Pulsed RF
Alarm ThresholdUser-Adjustable (Factory Default: 5 mW/cm²)
Dimensions100 × 210 × 35 mm
Weight~0.5 kg
Environmental Operating Range−10°C to +40°C, RH 51–81%, Atmospheric Pressure 720–780 mmHg
Sensor SensitivityOptimized for Wavelengths 3–33 cm
Internal ControlMicrocontroller-Based Architecture with Auto-Zero and Self-Test Functions
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuiyan
ModelMHJ-3
Instrument TypeMicrowave Power Density Meter
Frequency Range0.9–3 GHz
Antenna Gain>2 dBi
Measurement Range0.2 µW/cm² to 20 mW/cm²
Dimensions118 mm × 60 mm × 39 mm
Weight<80 g
Power SupplyPassive (RF-powered, no battery required)
ComplianceDesigned for IEC 60705:2017 (Household Microwave Ovens – Methods for Measuring Performance) and FDA 21 CFR §1030.10 (Performance Standard for Microwave and Radio Frequency Emitting Products)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHyundai
ModelMHJ-98A
Instrument TypeMicrowave Power Density Meter (Continuous & Pulsed Wave)
Measurement PrincipleBroadband Diode-Detector-Based RF Field Sensing
Frequency Range0.9–3 GHz
Power Density Range0.01–9.99 mW/cm²
Operating Temperature−10 °C to +40 °C
Calibration Uncertainty±0.75 dB
DisplayLED Digital, 3-digit
Analog Output0–5 V DC (proportional to measured power density)
Digital Switch OutputSPST, rated ≤24 V DC / 1 A
Overload Threshold100 mW/cm² (CW, non-destructive)
HousingCNC-Machined Aluminum Alloy (EMC-Optimized)
Power SupplyLinear Regulated DC Input
Dimensions152 × 104 × 42 mm
ComplianceIEC 61000-4 Series (EMC Immunity), ISO/IEC 17025 Traceable Calibration Protocol Support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuiyan
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelMY8C-1
PriceUpon Request
Microwave Frequency2450 MHz ± 50 MHz
Output Power Range0–200 W (continuous, linearly adjustable)
Waveguide StandardGB/T BJ-26 (FD-26 flange)
Cavity MaterialStainless Steel
Control InterfaceIndustrial-grade color touchscreen with embedded microcomputer controller
Power Density MonitoringReal-time display of source output power and cavity-internal power density
CalibrationUser-configurable power density calibration coefficient
Data VisualizationReal-time power density trend curve (sampling-based)
Operation ModesDual-mode dynamic power density regulation
Radiation ModeWaveguide-fed cavity irradiation or free-space radiation via optional waveguide antenna
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuiyan
OriginJiangsu, China
ModelML-91
Instrument TypeRF Power Density Meter (Radiation Dosimetry)
Frequency Range0.9–12.4 GHz
Measurement Range0.2 µW/cm² to 20 mW/cm²
Resolution0.2 µW/cm²
DisplayDigital LCD with Auto-ranging (3 ranges: 200 µW/cm², 2 mW/cm², 20 mW/cm²)
Alarm ThresholdFactory-set at 5 mW/cm² (adjustable only by manufacturer)
Operating ModesCW and Pulsed RF
Sensor Burnout Limit100 mW/cm² (CW), 3 W/cm² peak (pulsed)
Calibration Uncertainty±0.75 dB
Indicating Device Accuracy≤ ±1.5% of full scale
Dimensions (Indicator Unit)82 × 40 × 172 mm
Weight (Indicator Unit)~0.8 kg
Environmental Operating Range–10 °C to +40 °C, RH 51–81%, Atmospheric Pressure 720–780 mmHg