| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | DA7440 |
| Instrument Type | Online |
| Principle | Grating Scanning |
| Wavelength Range | 950–1650 nm |
| Scan Speed | 30 subspectra/sec |
| Data Sampling Interval | User-Configurable |
| Measurement Mode | Diffuse Reflectance / Transflectance |
| Chemometrics Software | Unscrambler X, Percal |
| Brand | Perten |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FT 9700 |
| Instrument Type | Laboratory |
| Application Domain | General-purpose (Academic & Research) |
| Operating Principle | Fourier Transform (FT) |
| Wavelength Range | 700–2500 nm (14,300–4000 cm⁻¹) |
| Scan Speed | <1 minute per spectrum |
| Data Sampling Interval | Adjustable |
| Sample Measurement Modes | Diffuse Reflectance and Transflectance |
| Chemometrics Software | PerCal |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | IM 8800 |
| Instrument Type | Portable |
| Application Field | Cereals & Oilseeds |
| Measurement Principle | Grating-based diode array (non-scanning) |
| Wavelength Range | 850–1050 nm |
| Scan Time | 20 seconds |
| Data Sampling Interval | 5 nm |
| Measurement Mode | Transmission |
| Chemometrics Software | Unscrambler® |
| GPS Integration | Yes |
| Power Supply | 12 V DC or internal rechargeable battery (2 h runtime) |
| Compliance | AACC Method 39-25 |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | IM9520 |
| Instrument Type | Benchtop Laboratory NIR Spectrometer |
| Application Domain | Cereal Grains & Milled Flour |
| Optical Principle | Grating Scanning Transmission NIR |
| Wavelength Range | 570–1100 nm |
| Scan Speed | 10 scans/minute |
| Data Acquisition Interval | 6 seconds per measurement |
| Sample Mode | Transmission |
| Chemometrics Software | Unscrambler® |
| Calibration Framework | NIST-traceable wavelength calibration |
| Compliance | ASTM D6341 (NIR for cereal analysis), ISO 12099:2017 (Animal feeding stuffs — General guidelines for the determination of chemical constituents by NIR spectroscopy), GLP-compliant data audit trail support via NetPlus™ |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | IM 9500plus |
| Instrument Type | Laboratory NIR Spectrometer |
| Application Domain | Cereal & Oilseed Analysis |
| Principle | Grating Scanning Transmission NIR |
| Wavelength Range | 570–1100 nm |
| Scan Speed | 10 scans/min |
| Data Acquisition Interval | 6 s/scan |
| Measurement Mode | Transmission |
| Chemometrics Software | Unscrambler X |
| Brand | Rayleigh |
|---|---|
| Origin | Beijing, China |
| Model | WQF-600N |
| Instrument Principle | Fourier Transform (FT) |
| Wavenumber Range | 3300–10000 cm⁻¹ |
| Spectral Resolution | < 4 cm⁻¹ |
| Wavenumber Accuracy | Better than half the set resolution |
| Transmittance Repeatability | ±0.5% T |
| Signal-to-Noise Ratio (S/N) | >10,000:1 (RMS, 32 scans at 4300–4400 cm⁻¹) |
| Beam Splitter | CaF₂ |
| Detector Options | DTGS (PbS, InGaAs optional) |
| Light Source | Air-cooled tungsten-halogen lamp |
| Data System | PC-based with Windows OS |
| Software | Full-featured FT-NIR acquisition, preprocessing, chemometric modeling, and spectral analysis suite compliant with ASTM E1655 and ISO 12099 |
| Brand | Resonon |
|---|---|
| Origin | USA |
| Model | Pika IR |
| Instrument Type | Online Hyperspectral Imager |
| Principle | Push-broom Imaging Spectroscopy |
| Spectral Range | 900–1700 nm |
| Spectral Resolution | 4.9 nm |
| Spectral Bands | 164 |
| Spatial Pixels per Line | 320 |
| Max Frame Rate | 520 fps |
| Bit Depth | 14-bit |
| Weight | 2.7 kg |
| Dimensions (L×W×H) | 11.0 × 29.6 × 8.9 cm |
| Interface | Gigabit Ethernet |
| Operating Temperature | 5–40 °C |
| Aperture | f/1.8 |
| Pixel Size | 30 µm |
| Average RMS Spot Radius | 10 µm |
| Smile (Peak-to-Peak) | 10 µm |
| Keystone (Peak-to-Peak) | 10 µm |
| Radiometric Calibration | Included |
| Pre-installed Software | SpectrononPro, Resonon Acquisition & Analysis Suite |
| Brand | Resonon |
|---|---|
| Origin | USA |
| Model | Pika IR+ |
| Instrument Type | Online Hyperspectral Imager |
| Principle | Push-broom Imaging Spectroscopy |
| Spectral Range | 900–1700 nm |
| Spectral Resolution | 2.5 nm |
| Spectral Bands | 328 |
| Spatial Pixels | 640 |
| Max Frame Rate | 249 fps |
| Data Bit Depth | 14-bit |
| Weight | 2.7 kg |
| Dimensions (L×W×H) | 11.0 × 29.6 × 8.9 cm |
| Interface | GigE Vision |
| Operating Temperature | 5–40 °C |
| Aperture | f/1.8 |
| Pixel Size | 15 µm |
| RMS Spot Radius (avg.) | 10 µm |
| Smile (peak-to-peak) | 10 µm |
| Keystone (peak-to-peak) | 10 µm |
| Radiometric Calibration | Included |
| Pre-installed Software | SpectrononPro, Resonon Acquisition & Analysis Suite |
| Brand | SAMA |
|---|---|
| Origin | Japan |
| Model | S-7010 |
| Instrument Type | Portable |
| Principle | Multi-channel Fourier Transform NIR |
| Wavelength Range | 700–1050 nm |
| Scan Speed | 1 s per spectrum |
| Data Sampling Interval | 3 s |
| Measurement Time | 2–3 s per sample |
| Chemometrics Software | S-7010 Software |
| Light Source | Halogen lamp (avg. lifetime: 40,000 h) |
| Detector | 16-bit ADC |
| Interface | USB 2.0 |
| Power Supply | 6 × rechargeable AA batteries |
| Operating Time | ~1 h |
| Dimensions (W×H×D) | 296 × 98 × 233 mm |
| Weight | 5.3 kg |
| Application Scope | Academic research & QC in meat science, food chemistry, and agricultural laboratories |
| Brand | SEI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PSP-1100 |
| Instrument Type | Portable |
| Operating Principle | Fixed-grating array detector (non-scanning) |
| Wavelength Range | 320–1100 nm |
| Integration Time | 8–2000 ms |
| Sampling Interval | 1.5 nm |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | DARWin SP |
| Optical Resolution | 3.2 nm (FWHM) |
| Stray Light | <0.05% @ 700 nm |
| Detector | 512-element silicon photodiode array (25 µm × 2.5 mm pixel size) |
| A/D Conversion | 16-bit |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ±0.1 nm |
| NEΔL (400 nm, 1 s) | 8.0×10⁻¹⁰ W/cm²/nm/sr |
| NEΔL (700 nm, 1 s) | 7.0×10⁻¹⁰ W/cm²/nm/sr |
| NEΔL (900 nm, 1 s) | 1.5×10⁻⁹ W/cm²/nm/sr |
| Max Radiance @700 nm | 1.5×10⁻⁴ W/cm²/nm/sr |
| Input Port | 25° fiber optic coupling |
| Slit Width | 50 µm |
| Power Supply | Internal 2800 mAh rechargeable Li-ion battery (operating time >4 h) |
| Dimensions | 17.8 × 8.3 × 14.6 cm |
| Weight | <1.8 kg |
| Communication Interfaces | USB 2.0, Bluetooth 4.0 |
| Compliance | CE, FCC Part 15, RoHS |
| Brand | Lumex |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | S400 Near-Infrared Spectrometer |
| Pricing | Available Upon Request |
| Wavelength Range | 1300–2500 nm |
| Wavelength Repeatability | ≤1 nm |
| Scan Interval Options | 4 cm⁻¹, 8 cm⁻¹, 16 cm⁻¹ |
| Absorbance Repeatability | ≤0.002 A |
| Signal-to-Noise Ratio | ≥10³ (at 2100 nm, 32 scans) |
| Display | 800 × 600 true-color LCD touchscreen |
| Communication Interface | RS-232 serial port |
| Printer Compatibility | Standard inkjet printers |
| Detector | Cooled PbS photodetector (Japan-sourced) |
| Integrating Sphere Reflectance | ≥95% |
| Sample Rotation Stage | Motorized 360° continuous rotation |
| Integrated Sample Holders | Dual-configurable cup and flat-surface cells |
| Scan Time | <120 seconds per spectrum |
| Brand | Spectral Engines |
|---|---|
| Origin | Finland |
| Model | NIRONE DEVICE |
| Instrument Type | Portable NIR Spectrometer |
| Operating Principle | Micro-Electro-Mechanical Systems (MEMS)-Based Fabry–Pérot Interferometer |
| Wavelength Range | 1150–1950 nm (standard configuration) |
| Spectral Acquisition Time | <50 ms per spectrum |
| Spectral Sampling Interval | Adjustable from 1 to 10 nm |
| Optical Measurement Modes | Diffuse Reflectance and Transmission |
| Detector | Single-pixel InGaAs photodiode with integrated thermoelectric stabilization |
| Spectral Resolution (FWHM) | 15–25 nm |
| Wavelength Tuning Speed | <1 ms per step |
| Tuning Step Size | 0.1 nm (up to 512 discrete wavelengths) |
| Data Interfaces | Bluetooth 5.0 + USB 2.0 (micro-USB) |
| Onboard Power | Rechargeable Li-ion battery (≥8 h typical operation) |
| Software Suite | NIRSA Chemometrics Platform + SensorControl PC/Android/iOS Application |
| Compliance | CE, RoHS, FCC Part 15 Class B |
| Firmware Architecture | Field-upgradable via OTA or USB |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NIRONE SENSOR |
| Instrument Type | Portable |
| Application Domain | General-purpose (Universities & Research Labs) |
| Operating Principle | MEMS-based Fabry–Pérot Interferometer |
| Wavelength Ranges | 1150–1350 nm (S 1.4) |
| Scan Speed | <50 ms per spectrum |
| Spectral Sampling Interval | Adjustable from 1–10 nm |
| Measurement Modes | Diffuse Reflectance & Transmission |
| Chemometrics Software | NIRSA |
| Brand | Spectral Evolution |
|---|---|
| Origin | USA |
| Model | LF2500/1250/880 |
| Instrument Type | Portable Field Spectroradiometer |
| Optical Design | Fixed Holographic Grating + Linear Array Detector (Non-scanning) |
| Wavelength Range | 350–2500 nm (LF2500), 350–1250 nm (LF1250), 350–880 nm (LF880) |
| Spectral Sampling Interval | ≤1.5 nm (LF2500), ≤1.0 nm (LF1250), ≤0.6 nm (LF880) |
| Integration Time | 8 ms – 2000 ms |
| Full-Spectrum Acquisition Speed | ≤100 ms (up to 10 Hz) |
| Measurement Mode | Diffuse Reflectance, Irradiance, Radiance, Transmittance |
| Calibration | NIST-Traceable Absolute Radiometric & Spectral Calibration |
| Software | DARWin SP v5.x (Windows-based, FDA 21 CFR Part 11 compliant audit trail option available) |
| Power | Rechargeable Li-ion Battery (≥8 h field operation) |
| Communication | Integrated Bluetooth 5.0 & USB-C |
| Housing | Anodized Aluminum (IP54 rated, thermal stability ±0.05 nm/°C) |
| Brand | Spectral Evolution |
|---|---|
| Model | LF780/500 |
| Origin | USA |
| Instrument Type | Portable Field Spectroradiometer |
| Optical Design | Fixed Holographic Grating + Linear Array Detector (Non-scanning) |
| Wavelength Range | 350–2500 nm (simultaneous coverage across UV-Vis-NIR) |
| Spectral Sampling Interval | ≤1.5 nm (VIS-NIR), ≤3.0 nm (SWIR) |
| Spectral Resolution (FWHM) | ≤3 nm (350–1000 nm), ≤10 nm (1000–2500 nm) |
| Integration Time | 8 ms to 2000 ms (programmable) |
| Measurement Mode | Diffuse Reflectance, Irradiance, Radiance |
| Calibration Traceability | NIST-traceable, factory-calibrated with spectralon-based standards |
| Data Acquisition Software | DARWin SP v5.x (Windows OS compatible) |
| Communication | Bluetooth 5.0 + USB-C |
| Power | Removable Li-ion battery (≥8 h field operation) |
| Housing | Anodized aluminum alloy (IP54-rated, thermal-stabilized chassis) |
| Built-in Features | Motorized shutter, drift-compensated auto-calibration, laser targeting module (635 nm, <1 mW), internal reference lamp |
| Brand | Spectral Evolution |
|---|---|
| Origin | USA |
| Model | oreXpress |
| Instrument Type | Portable |
| Optical Principle | Fixed-grating array-detector (non-scanning) |
| Wavelength Range | 350–2500 nm |
| Sampling Interval | 1.5 nm (350–1000 nm), 3.8 nm @ 1500 nm, 2.5 nm @ 2100 nm |
| Measurement Mode | Diffuse Reflectance |
| Software | DARWin SP (data acquisition), EZ-ID (mineral identification), SpecMIN™, GRAMS®, TSG® |
| Detector Architecture | Dual silicon & InGaAs linear array |
| Battery | Removable high-capacity Li-ion |
| Integrated Field Terminal | GETAC PS336 with GPS, auto-focus camera, digital compass, altimeter, voice memo |
| Probe | Contact reflectance probe with pistol-grip handle, integrated 5W tungsten lamp, sapphire window |
| Brand | Spectral Evolution |
|---|---|
| Origin | USA |
| Model | Platinum |
| Instrument Type | Portable |
| Optical Principle | Fixed-grating array detector (non-scanning) |
| Wavelength Range | 350–2500 nm |
| Data Sampling Interval | 1 nm |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | DARWin SP |
| Mineral Identification Software | EZ-ID |
| Integrated Hardware | GETAC PS336 rugged handheld (GPS, auto-focus camera, digital compass, altimeter, voice memo), replaceable Li-ion battery, pistol-grip contact probe with 5 W tungsten halogen source and sapphire window |
| Spectral Libraries | USGS, SpecMIN™, customizable user libraries |
| Brand | Spectral Evolution |
|---|---|
| Origin | USA |
| Model | SR-1900 |
| Instrument Type | Portable |
| Operating Principle | Grating-based, non-scanning array detector |
| Spectral Range | 350–2500 nm |
| Spectral Sampling Interval | 1.5 nm (350–1000 nm), 3.8 nm @ 1500 nm, 2.5 nm @ 2100 nm |
| Measurement Mode | Diffuse Reflectance |
| Calibration Traceability | NIST-traceable |
| Data Acquisition Software | DARWin SP (Windows) & DARWin CE Mobile (PDA-compatible) |
| Detector Configuration | 512-element enhanced Si array (350–1000 nm) + 256-element thermoelectrically cooled InGaAs array (900–2500 nm) |
| Weight | < 3.3 kg (< 8 lbs) |
| Interface | USB 2.0 and Bluetooth 4.0 |
| A/D Resolution | 16-bit |
| Dimensions | 21.6 × 30.5 × 8.9 cm (8.5″ × 12″ × 3.5″) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UDS-1100 |
| Price Range | USD 21,000–28,000 |
| Instrument Type | Online/Field-Deployable |
| Operating Principle | Fixed-grating spectrometer with linear silicon photodiode array (non-scanning) |
| Wavelength Range | 320–1100 nm |
| Integration Time | 8–2000 ms |
| Spectral Sampling Interval | 1.5 nm |
| Spectral Resolution (FWHM) | 3.2 nm |
| Detector | 512-element Si photodiode array |
| A/D Conversion | 16-bit |
| Slit Width | 50 µm |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ±0.1 nm |
| Radiometric Noise (NEΔL) | 8.0×10⁻¹⁰ W/cm²/nm/sr @400 nm (1 s), 7.0×10⁻¹⁰ W/cm²/nm/sr @700 nm (1 s), 1.5×10⁻⁹ W/cm²/nm/sr @900 nm (1 s) |
| Maximum Radiance @700 nm | 1.5×10⁻⁴ W/cm²/nm/sr |
| Calibration | NIST-traceable factory radiometric calibration |
| Dark Current Compensation | Automatic per-scan |
| Auto-Exposure Control | Yes |
| Measurement Geometry | Diffuse Reflectance / Hemispherical Radiance |
| Software | DARWin SP v5.x (Spectral Evolution) |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FluidScan 1000 |
| Instrument Type | Portable |
| Wavelength Range | 900–4000 cm⁻¹ |
| Measurement Principle | Fourier Transform Near-Infrared (FT-NIR) Spectroscopy |
| Sample Method | Direct Drop-on-Cell Dispersive Analysis |
| Software | Fluid Manager™ |
| Compliance | ASTM D7889, ASTM E2412, ASTM E1655 |
| Application Domain | Industrial Lubrication Monitoring in Petrochemical, Power Generation, and Heavy Machinery Sectors |
| Origin | UK |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | SpectroSense2 |
| Price | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | TCM 500 Turf Colorimeter |
| Pricing | Upon Request |
| Measurement System | Internal LED-based reflectance at red (650 nm) and near-infrared (850 nm) wavelengths |
| Measurement Area | ~7.75 cm diameter (3.0 in) |
| Output Units | RED (%) and NIR (%), Green Index (0–9.9), NDVI = (NIR − RED) / (NIR + RED) |
| Repeatability | ±5% of reading |
| Data Storage Capacity | 3,250 measurements (GPS/DGPS disabled) |
| Power Supply | 9 V alkaline battery (~3,000 measurements per charge) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | Antaris II |
| Instrument Type | Laboratory |
| Operating Principle | Fourier Transform (FT) |
| Wavelength Range | 3800–12000 cm⁻¹ |
| Scan Speed | 5 scans/sec |
| Data Sampling Interval | 2 cm⁻¹ |
| Measurement Modes | Transmission, Diffuse Reflectance, Transflectance, Transdiffuse |
| Chemometrics Software | TQ Analyst |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Antaris MX |
| Instrument Type | Online/At-line Portable FT-NIR Analyzer |
| Principle | Fourier Transform Near-Infrared Spectroscopy (FT-NIR) with Real-time Process Integration |
| Wavelength Range | 4000–12000 cm⁻¹ |
| Scan Speed | 5 scans per second |
| Spectral Resolution | 2 cm⁻¹ (data sampling interval) |
| Measurement Modes | Transmission, Transflection, Diffuse Reflectance |
| Chemometrics Software | TQ Analyst v9+ and RESULT v3.x |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Antaris Target In-Process Mixing Monitor |
| Instrument Category | Online Near-Infrared Spectrometer |
| Operating Principle | Fourier Transform (FT-NIR) |
| Wavelength Range | 5300–7500 cm⁻¹ |
| Scan Speed | 12.5 scans/second |
| Spectral Sampling Interval | 0.7 nm |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | TQ Analyst |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | microPHAZIR GP |
| Principle | Portable, Non-Destructive NIR Spectroscopy |
| Weight | 1.3 kg |
| Spectral Range | 1600–2400 nm |
| Measurement Time | ≤3 s (configurable) |
| Light Source | Tungsten-Halogen Lamp |
| Data Storage | Internal Memory |
| Data Transfer | USB (text-based .csv/.txt) |
| Operating Temperature | 5–40 °C |
| Battery | Rechargeable Li-ion with Hot-Swap Capability |
| Enclosure | Dust- and Splash-Resistant High-Impact Polymer Housing |
| Security | Multi-Level Password Protection |
| Standard Accessories | Rugged Waterproof Carry Case, Li-ion Battery Pack, 110/220 VAC Charger, Lanyard |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | microPHAZIR PC Carpet |
| Principle | Portable, On-Site NIR Spectroscopy |
| Weight | 1.25 kg |
| Measurement Time | 1.5 s |
| Light Source | Tungsten-Halogen Lamp |
| Display | Color LCD |
| Data Interface | USB to PC |
| Battery | Rechargeable Li-ion (≥5 h runtime, <2 h recharge time, dual-battery configuration) |
| Enclosure | Dust- and Splash-Resistant Engineering Plastic |
| Preloaded Library | Carpet Fiber Identification Database |
| Security | Multi-Level Password Protection |
| Calibration | Factory-Calibrated, Ready-to-Use Out-of-Box |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | microPHAZIR PC Plastics |
| Principle | Portable, On-Site NIR Spectroscopy |
| Spectral Range | 1600–2400 nm (6250–4100 cm⁻¹) |
| Measurement Time | <3 s |
| Sampling Mode | Diffuse Reflectance |
| Weight | 1.25 kg |
| Housing | High-Strength Dust-Resistant Polymer Enclosure |
| Light Source | Tungsten-Halogen Lamp |
| Data Storage | Internal Memory with USB Export |
| Interface | USB |
| Operating Temperature | 5–50 °C (non-condensing) |
| Power Supply | Dual Swappable Li-ion Batteries (4.5 h runtime), AC Adapter & Charger Included |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | microPHAZIR™ Rx |
| Instrument Category | Portable NIR Spectrometer |
| Principle | Portable, non-destructive near-infrared reflectance spectroscopy |
| Wavelength Range | 1600–2400 nm |
| Scan Rate | 2 spectra per second |
| Data Acquisition Interval | 0.5 s (2 Hz) |
| Measurement Mode | Contact-based diffuse reflectance NIR analysis |
| Chemometrics Software | Method Generator™ |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Models | TruScan RM, microPHAZIR RX |
| Principle | Portable, Non-Destructive, In-Situ Spectroscopic Identification |
| Regulatory Compliance | 21 CFR Part 11, USP <1119>, EP 2.2.48, ASTM E1840, ISO/IEC 17025 |