Empowering Scientific Discovery

Onkel Limited

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnseros
OriginGermany
ModelSIM 6300
Ozone Measurement PrincipleNon-dispersive UV absorption
Ozone Range0–100 / 1,000 / 10,000 pphm
Response Time5 s
Detection Limit1 pphm
Accuracy±0.2% of reading
Repeatability±0.2% of full scale
Temperature Control Range15–70 °C (RT = 23 °C)
Temp. Accuracy±5 K
Temp. Ramp Rate0.4 K/min
Humidity Range30–80% RH
Humidity Accuracy–1 to +4% RH
Humidity Stabilization Time to 95%≤20 min
Ozone Control Range20–200 pphm
Ozone Control Accuracy±1 pphm
Ozone Stabilization Time to 95%10 min
Airflow Velocity in Chamber600 mm/s
Air Exchange Rate400 L/h
Chamber Internal Dimensions680 × 650 × 400 mm
External Dimensions950 × 870 × 610 mm
Power Supply230 V / 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAOM Systems
OriginGermany
ModelSpraySpy LabLine / SpraySpy ProcessLine
Measurement PrincipleLaser-based Time-of-Flight Droplet Sizing & Velocimetry
Output ParametersDroplet Diameter (µm), Velocity (m/s), Number Density (1/cm³), Transparency Classification, Volumetric Flow Density (mL/min·cm²), Momentum (kg·m/s)
Environmental RatingATEX Zone 1/21 Certified
Data ComplianceFDA 21 CFR Part 11 Ready (Audit Trail & Electronic Signature Optional)
Software PlatformSprayAI v4.2 (Real-time AI Analytics Engine)
Integration InterfaceEtherCAT, PROFINET, OPC UA, RESTful API
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnseros
OriginGermany
ModelSIM6200-T-CL
Chamber Volume230 L
Internal Dimensions (H×W×L)50 × 68 × 68 cm
Total Dimensions (H×W×L)181 (+43) × 99 × 120 (+10) cm
Weight400 kg
Power Supply230/120 VAC, 50/60 Hz
Ozone Concentration Range0–1000 pphmv
Airflow Velocity (in chamber)8–16 mm/s (longitudinal, laminar flow)
Reynolds Number (Re)300–1000
Loading FactorG = 12 s/m (per ISO 1431-1)
Certified Ozone AnalyzerMP60602
Ozone GeneratorMaintenance-Free Type
Control SystemSiemens SIMATIC S7-300 PLC with 15″ Touchscreen HMI
Data InterfaceRS232, USB
Safety FeaturesCatalytic ozone destruct, activated carbon filter, turbofan recirculation, interlocked safety door, audible/visual alarms
ComplianceASTM D1149, ISO 1431-1, DIN ISO 1431-1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANSEROS
OriginGermany
ModelSIM 8000
Chamber Volume8000 L
Temperature Range15–70 °C (RT = 23 °C)
Humidity Range30–80 % RH
Ozone Concentration Control20–200 pphm
Ozone Measurement PrincipleNon-dispersive UV Absorption
Ozone Detection Limit1 pphm
Response Time5 s
Accuracy±1 pphm (ozone), ±5 K (temperature), −1 to +4 % RH (humidity)
Airflow Velocity in Test Zone600 mm/s
Air Exchange Rate400 L/h
Power Supply230 V / 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnseros
OriginGermany
ModelSIM 6010T
Temperature Range26–60 °C (standard), 15–70 °C (extended)
Humidity Range30–80 % RH
Ozone Concentration Control Range20–200 pphm
Ozone Measurement PrincipleNon-dispersive UV absorption
Ozone Measurement Range0–100 / 1,000 / 10,000 pphm
Detection Limit1 pphm
Response Time5 s
Accuracy±0.2 % of reading (ozone sensor)
Airflow Velocity in Chamber600 mm/s
Air Exchange Rate400 L/h
Recovery Time to 95 % Set Ozone Level≤10 min
Recovery Rate0.4 K/min
Temperature CompensationAutomatic, 0–60 °C ±1 °C
Pressure CompensationAutomatic, 600–1500 mbar ±2 mbar
Zero DriftAuto-zeroing cycle every 2 s
Span DriftNone (single-beam optical design)
Power Supply230 V / 50 Hz
External Dimensions950 × 870 × 610 mm
Usable Internal Volume680 × 650 × 400 mm
Generator/Controller/Detector Cabinet1600 × 550 × 600 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANSEROS
OriginGermany
ModelSIM6300-T-CL
ComplianceASTM D1149, ISO 1431-1, DIN ISO 1431-1
Ozone GenerationMaintenance-free corona discharge generator
Ozone MonitoringCertified ozone analyzer (MP series) with closed-loop feedback control
Control SystemProgrammable logic controller (PLC) with interrupt-resume functionality for long-term durability testing
Air CirculationRecirculating turbojet system integrated with catalytic ozone destruct unit and activated carbon filter
Sample MountingDual-mode fixture—static test racks and dynamic rotating sample disc (4-position V-groove clamping)
Data InterfaceRS232 serial port for real-time logging to ANSEROS on-board monitoring software
Chamber ConfigurationClimate-controlled enclosure with temperature stabilization (ambient to +70 °C, ±0.5 °C uniformity)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANSEROS
OriginGermany
ModelSIM-6300
Internal Dimensions680 × 680 × 500 mm
External Dimensions1610 × 1500 × 1000 mm
Gas Flow Velocity8–700 mm/s
Air Exchange Rate50–500 L/min
Air Replacement Rate1–2000 dm³/h (33 L/min)
Temperature RangeRT to 70 °C ±0.5 °C
Humidity Range30–90 %RH (±1/+4 %RH)
Ozone Measurement PrincipleSingle-beam NDUV Photometry
Ozone Concentration Range0–1999 mg O₃/Nm³ or 0–1000 ppmv
Sensitivity0.001 ppmv
Accuracy<1 % SCE
Linearity98 % SCE
Ozone Generation MethodCorona Discharge (COM-ADM)
Ozone Output Capacity10–2000 mg/h
Ozone Flow Rate100–2000 NL/h
Power Consumption3000 W
Voltage230 V, 10 A
Weight250 kg
Compliant StandardsASTM D1149, ASTM D2802, ASTM D4246-02, ASTM D4575, ASTM D470, ASTM D518, BS 903 A43, DIN 53509-2-1, FORD FLTM BP101-01, GB/T 11206-2009, GB/T 13642-1992, GB/T 2951.1–2951.10-1997, GB/T 2951.21-2008, GB/T 7762-2003, HG/T 2716-2008, HG/T 2869-1997, ISO 1431-1 & -3, MIL-STD-1344A, NGF 37112, SAE J1401, SIS 16 12 10
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnseros
OriginGermany
ModelSIM 6050-T
Temperature Range15–70 °C (RT = 23 °C)
Humidity Range30–80 % RH
Ozone Concentration Control Range20–200 pphm
Ozone Measurement PrincipleNon-dispersive UV absorption
Ozone Detection Limit1 pphm
Response Time5 s
Temperature Accuracy±5 K
Humidity Accuracy−1 to +4 % RH
Airflow Velocity in Test Chamber600 mm/s
Air Exchange Rate400 L/h
Chamber Internal Dimensions425 × 460 × 270 mm
External Dimensions670 × 620 × 510 mm
Power Supply230 V / 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnseros
OriginGermany
ModelSIM 7500
Temperature Range26–60 °C (RT = 23 °C)
Humidity Range30–80 % RH
Ozone Concentration Control Range20–200 pphm
Ozone Measurement PrincipleNon-dispersive ultraviolet (NDUV) absorption
Ozone Detection Limit1 pphm
Response Time5 s
Temperature Accuracy±5 K
Humidity Accuracy−1 to +4 % RH
Airflow Velocity600 mm/s
Air Exchange Rate400 L/h
Chamber Internal Dimensions425 × 460 × 270 mm (standard)
Power Supply230 V / 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNorman Tool
OriginUSA
Manufacturer TypeAuthorized Distributor
Product CategoryImported Instrument
ModelRCA7-IBB
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCoatmaster
OriginSwitzerland
ModelCoatmaster Inline, Coatmaster Flex
Measurement PrincipleThermal-Optical (Patented)
ApplicationNon-destructive, real-time thickness measurement of wet/dry/powder coatings on carbon fiber composites and other non-metallic substrates
ComplianceDesigned for GLP/GMP environments
IP RatingIP20 (Flex), IP65-rated enclosure options available for Inline
Measurement Distance Range2–15 cm (Flex), 10–120 cm (Inline)
Tilt Tolerance±45° (substrate-dependent)
Repeatability<1% RSD (Flex), <2% RSD (Inline, Al substrate, 60 µm uncured powder)
ThroughputUp to 120 m/min (Inline)
Coating TypesAll colors including white
OutputReal-time dry-film equivalent (DFE) thickness from wet or uncured layers
Data AccessBrowser-based cloud dashboard + ERP integration
Measurement Speed0.3 s (Flex), 0.5 s (Inline)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAdam
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPMB
PricingAvailable Upon Request
Capacity50 g / 200 g
Readability0.001 g / 0.01 % (PMB 53)
Repeatability (S.D.)0.005 g / 0.05 % (10 g sample, PMB 53)
Pan DiameterØ90 mm
Heating Range50–160 °C
Max. Test Duration99 minutes
Heating Source400 W Halogen Lamp
Heating ModesRamp, Step, Standard
Stabilization Time2–3 s
DisplayDual-line LED backlight with range-tracking indicator
InterfacesUSB Host, USB I/O, RS-232
Internal Memory99 test results, 49 test methods
External StorageUSB flash drive support
CalibrationExternal calibration only
Power Supply110/220 V, 50/60 Hz
Operating Temperature0–40 °C
Dimensions (W×D×H)360 × 250 × 185 mm
Net Weight6 kg
LanguagesEnglish, German, French, Spanish
Unitsg, % liquid, % solid, ATRO % M (moisture on dry basis), ATRO % S (solids on dry basis)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCoatmaster
OriginSwitzerland
ModelCoatmaster Inline
ComplianceISO 2808, ASTM D7091, ISO 2360 (eddy current & thermal principles adapted), CE, RoHS
Measurement PrincipleAdvanced Thermal Optics (ATO) with Digital Signal Processing (DSP)
Substrate CompatibilityFerrous metals (steel, galvanized steel), aluminum alloys
Coating TypesLiquid paints (e-coat, primer, basecoat, clearcoat), powder coatings, UV-curable coatings
Operating EnvironmentIndustrial paint shop (temperature: 15–40 °C
humidity30–80% RH non-condensing)
Measurement SpeedUp to 3 m/s conveyor speed
Spot SizeØ3–5 mm (adjustable via optical configuration)
Repeatability≤ ±0.5 µm (on stable steel substrates with uniform coating)
Data OutputReal-time thickness values (wet & predicted dry film thickness), statistical summaries (X̄, R, Cpk), alarm triggers (configurable thresholds), CSV/Excel export
Software InterfaceCoatmaster Control Suite v5.x with audit trail, user role management, and 21 CFR Part 11–compliant electronic signatures (optional module)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSITA
OriginGermany
ModelCleanoSpector, Fluoscan 3D
Detection PrincipleUV-Induced Fluorescence (Confocal Optical Method)
Measurement Range0–100% Relative Contamination Index (RCI)
Resolution0.1% RCI
Repeatability±0.5% RCI
Sample TypeMetallic substrates (steel, aluminum, titanium, sintered metal components)
ComplianceISO 8502-10, ASTM D7235, VDA 19.1, ZVEI Guideline “Cleanliness in Electrical Contacts”
SoftwareSITA CleanControl v4.x with Audit Trail, Electronic Signature, and 21 CFR Part 11 Compliance Mode
Data ExportCSV, PDF, XML
InterfaceUSB 3.0, Ethernet, Optional Bluetooth
Operating Temperature10–40 °C
CalibrationTraceable to NIST-traceable reference standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabman
OriginGermany
ModelTIDAS
Measurement PrincipleHegman-type grind gauge imaging analysis
Sample ApplicationLiquid dispersions (paints, inks, coatings, slurries)
Plate Range Compatibility0–15 µm, 0–25 µm, 0–50 µm, 100 µm, 250 µm (custom plates available)
Imaging ResolutionHigh-definition digital capture
Analysis Time≤1 s per image
Total Cycle Time~15 s (including auto-coating)
Software PlatformWindows 7/8/10 native
Data OutputHistograms, particle size distribution profiles, pass/fail grading per ISO 1524 or ASTM D1316
Compliance SupportAudit-trail ready, GLP/GMP-compatible metadata logging
InterfaceUSB 2.0
System Lifespan≥12 years (field-validated)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHNPM
OriginGermany
Modelmzr-4605
Drive TypeElectric
Speed Range0–300 rpm
Flow Rate1 µL/h – 1.1 L/h
Dimensions (L)143 mm
Viscosity RangeCompatible with methanol, water, solvents, adhesives, oils, gels
TechnologyRotating micro annular gear
Pulse DampeningLow-pulsation delivery
Shear StressLow-shear transport
Optional ModulesThermal insulation kit, fluid-sealed air/moisture barrier, electric heating module (up to 150 °C), dual-shell temperature control (–20 °C to +150 °C), torque reducer, mzr-S05/S05E control console
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-LAB
OriginUSA
ModelXe-1
Xenon Lamp Power1800 W
Lamp CoolingAir-cooled
Lamp Lifetime~1500 hours
Filter OptionsDaylight-F / Daylight-Q / Daylight-B/B / Window-Q / Window-B/SL / Window-SF-5 / Window-IR / Extended UV-Q/B
Sample MountingHorizontal flat tray
Chamber TypeBenchtop
ComplianceASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 105-B02, GB/T 16422.2
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTQC
OriginNetherlands
ModelSP4300
Instrument TypeAutomatic
Drive MechanismElectronic micro-stepping motor
Stroke Range0–12 mm
Stroke Resolution0.01 mm
Punch Speed Range0.01–0.70 mm/s
Speed Accuracy±1% of set value
Stroke Accuracy±0.01 mm
Max. Test Panel Width100 mm
Max. Steel Thickness0.8 mm
Max. Aluminum Thickness1.2 mm
Dimensions (D×W×H)450 × 350 × 600 mm
Net Weight~31 kg
Power Supply115–230 V, 50–60 Hz
Max. Power Consumption80 W
DisplayBacklit LCD with multilingual UI
Safety FeaturesEmergency stop button, audible alarm
ComplianceISO 1520, DIN EN ISO 1520, DIN 53156, DIN 53232, BS 3900-E4, NBN T22-104, NF T30-019
CertificationQualicoat & QIB Laboratory Accredited
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-LAB
OriginCanada
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelQUV (Imported from USA)
QuotationUpon Request
Illuminant Temperature Range (°C)Configurable per test standard
Black Panel Temperature Range (°C)35–80 °C (typical operating range)
UV Wavelength Range (nm)295–400 nm (selectable via lamp type: UVA-340 or UVB-313)
Chamber Dimensions (L×W×H)1100 × 500 × 420 mm (standard QUV se model)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDefelsko
OriginUSA
ModelPosiTest F/G
Measurement PrincipleElectromagnetic Induction (F-type) / Eddy Current (G-type)
F-Type Range0–2000 µm (0–80 mils)
G-Type Range0–200 µm (0–8 mils)
F-Type Accuracy±5 µm (≤100 µm), ±5% of reading (>100 µm)
G-Type Accuracy±1 µm (≤20 µm), ±5% of reading (>20 µm)
Probe TypePermanent Magnet (F) / High-Frequency Eddy Current (G)
ComplianceASTM D7091, ISO 2178, ISO 2360, SSPC-PA 2, GB/T 4956, GB/T 4957
Power SourceNone (magnet-driven)
Environmental RatingIP65-equivalent robust housing
CalibrationNIST-traceable certificate supplied with each unit
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
ModelXe-3-HDS
Lamp TypeAir-Cooled Xenon Arc Lamp (3-lamp configuration)
Spectral RangeFull-spectrum solar simulation (290–800 nm)
Irradiance ControlSOLAR EYE® broadband or narrowband (340 nm, 420 nm, or TUV 300–400 nm)
Black Panel Temperature Range42–120 °C
Chamber Air Temperature RangeAmbient to 90 °C (with optional refrigerated cooling unit)
Relative Humidity Control10–95% RH (standard)
Sample Tray Dimensions451 mm × 718 mm
Sample CapacityUp to 51 specimens (51 mm × 102 mm)
Dual Spray SystemStandard (deionized water + secondary solution, e.g., acid rain or detergent)
CalibrationAUTOCAL® automated calibration system
ComplianceASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 11341, IEC 60068-2-9
InterfaceTouchscreen controller with built-in Ethernet, self-diagnostic alerts, GLP/GMP-ready audit trail logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-LAB
OriginUSA
ModelQUV/SE
Chamber Dimensions (L×W×H)114 × 50 × 40 cm
Light Source OptionsUVA-340 or UVB-313 fluorescent lamps
Irradiance ControlSolar Eye® closed-loop feedback system
Black Panel Temperature Range35–80 °C
Condensation Temperature Range40–60 °C
Illumination Temperature Range45–80 °C
Sample Capacity48 specimens (75 × 150 mm)
Power Supply120 V / 60 Hz, 16 A or 230 V / 50–60 Hz, 8 A
Water Consumption8 L/day (condensation mode)
Lamp Life (avg.)5000 h
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCoatmaster
OriginSwitzerland
ModelCoatmaster EX Inline
TypeNon-contact, Photothermal (ATO) Wet-Film & Dry-Film Thickness Gauge
ComplianceATEX/IECEx Zone 1/21 Certified for Hazardous Areas
Measurement PrinciplePulsed Optical Heating + High-Speed Infrared Thermography + Dynamic Thermal Decay Analysis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-LAB
OriginUSA
ModelQ-SUN B02-S
Xenon Lamp Power1800 W
ComplianceISO 105-B02, ISO 105-B04, AATCC TM 16 (Option 2 & 3), AATCC TM 169, M&S C9/C9A
Sample Capacity31 AATCC pre-cut specimens (1882 cm² total exposure area)
Lamp TypeAir-cooled xenon arc lamp
Lamp Life~1500 hours
Temperature ControlBlackboard temperature (35–103 °C), chamber air temperature
Humidity ControlRelative humidity (RH) with optional water spray
Filter SystemDual-filter assembly (outer borosilicate tube + inner 7-element filter set) for Window-IR (ISO/M&S) or Window-B/SL (AATCC) spectral profiles