Other Common Laboratory Equipment
Filter
Showing 181–210 of 387 results
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PCR-3A1, PCR-4A1 |
| Price | Upon Request |
| External Dimensions (L×W×H) | PCR-3A1: 1035 × 617 × 950 mm |
| PCR-4A1 | 1340 × 617 × 950 mm |
| Internal Dimensions (L×W×H) | PCR-3A1: 935 × 538 × 550 mm |
| PCR-4A1 | 1240 × 538 × 550 mm |
| Airflow Velocity | 0.30 m/s (60 fpm) |
| Power Supply | 230 VAC, 50 Hz |
| Pre-filter & HEPA Filter Efficiency | >99.99% at 0.3 µm |
| HEPA Service Life | ≥3 years (under typical lab conditions) |
| Control System | Esco Sentinel Microprocessor Controller |
| UV Timer & Alarm Functions | Yes |
| UV Lamp & Pre-filter Replacement Alerts | Yes |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Model | AC2-D |
| Certification | EN 12469 |
| Inflow Velocity | 0.45 m/s (90 fpm) |
| Downflow Velocity | 0.30 m/s (60 fpm) |
| Power Supply | 220 V, 50 Hz |
| ULPA Filter Efficiency | ≥99.999% @ 0.3 µm, ≥99.995% @ 0.1 µm |
| Work Surface | Seamless Stainless Steel |
| ISOCIDE™ Antimicrobial Coating | Yes |
| Control System | EscoSentinel Gold Microprocessor-Based Display |
| Connectivity | RS-232 Interface for BMS Integration |
| Available Widths | 1200 mm (4') and 1800 mm (6') |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Model | AC2-E |
| Certification | EN 12469 compliant |
| Airflow (Inflow) | 0.45 m/s (90 fpm) |
| Airflow (Downflow) | 0.30 m/s (60 fpm) |
| Power Supply | 230 V, 50/60 Hz |
| Filtration | ULPA filter with ≥99.995% efficiency at 0.1 µm |
| Surface Coating | Esco ISOCIDE® antimicrobial coating |
| Construction | Seamless stainless steel work chamber |
| Ergonomic Design | Integrated handrests, sloped front grille, spill-containment work surface |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Certification | EN 12469, IEST-RP-CC001, ISO 5 (Class 100) |
| Filter Efficiency | ULPA ≥99.995% @ 0.1 µm, ≥99% @ 0.3 µm |
| Inflow Velocity | 0.45 m/s (90 fpm) |
| Downflow Velocity | 0.30 m/s (60 fpm) |
| Power Supply | 220 V, 50 Hz |
| Construction | Stainless Steel Work Surface, ISOCIDE® Antimicrobial Coating |
| Control System | Sentinel Gold™ Microprocessor-Based Display |
| Connectivity | RS-232 Interface for BMS Integration |
| Noise Level | ≤65 dB(A) |
| Compliance | Meets NSF/ANSI 49, EN 12469, and EU Directive 2014/34/EU (ATEX) for optional UV configurations |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LA2-A |
| Pricing | Available Upon Request |
| External Dimensions (L×W×H) | Varies by variant (LA2-3A to LA2-8A) |
| Internal Work Area Dimensions | 970–2440 mm (L) × 623 mm (W) × 670 mm (H) |
| Inflow Velocity | 0.53 m/s (105 fpm) |
| Downflow Velocity | 0.35–0.33 m/s (70–65 fpm) |
| Power Supply | 220 VAC, 50 Hz |
| Filtration | Dual Minipleat ULPA filters (≥99.999% @ 0.1–0.3 µm) |
| Compliance | NSF/ANSI 49, EN 12469, YY 0569, JIS K 3800 |
| Control System | Sentinel Gold microprocessor-based digital display with RS232 interface |
| Ergonomics | 10° forward tilt, ADA-compliant angled control panel and handrest, seamless stainless steel work surface, ISOCIDE antimicrobial coating |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Model | LA2-G4 |
| External Dimensions (W×D×H) | 1035 × 815 × 1570 mm |
| Internal Dimensions (W×D×H) | 915 × 625 × 720 mm |
| Inflow Velocity | 0.53 m/s (105 fpm) |
| Downflow Velocity | 0.30 m/s (60 fpm) |
| Power Supply | 220–240 VAC, 50/60 Hz |
| Filtration | ULPA (≥99.999% @ 0.12 µm) |
| Work Area Cleanliness | ISO Class 3 |
| Noise Level | ≤56 dBA |
| Fan Type | DC-ECM (70% energy reduction vs. AC motors) |
| Compliance | NSF/ANSI 49-2022, EN 12469:2000, AS 2252.2–2013 |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Model | LB2-B |
| Certification | NSF/ANSI 49, YY0569 |
| Airflow Inflow | 0.53 m/s |
| Downflow Velocity | 0.31 m/s |
| Power Supply | 220 VAC, 50 Hz |
| Construction | Seamless Stainless Steel Work Chamber |
| Filtration | ULPA (≥99.999% @ 0.12 µm) |
| Compliance | Fully compliant with NSF/ANSI 49-2022 for Class II, Type B2 cabinets |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | LBC |
| Pricing | Available Upon Request |
| Capacity Range | 35–175 L |
| Static Evaporation Rate | 0.36–0.87 L/day |
| Static Hold Time | 97–202 days |
| Neck Opening Diameter | 125–216 mm |
| Outer Dimensions (Ø × H) | 451–680 mm × 700–1130 mm |
| Net Weight | 17.2–56 kg |
| Construction | Dual-Wall Aluminum with High-Vacuum Insulation |
| Vacuum Warranty | 5 Years |
| Compliance | For Research & Industrial Use Only (Not for Medical, Clinical, or Diagnostic Applications) |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Model | ACB-A1 |
| External Dimensions (W × D × H) | 1340 × 629.5 × 983 mm |
| With Stand Dimensions | 1340 × 629.5 × 1694 mm |
| Internal Dimensions | 1270 × 525 × 570 mm |
| Inflow Velocity | 0.30 m/s |
| Power Supply | 230 V, 50 Hz |
| Compliance | EN 12469 |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TCB |
| Quotation | Upon Request |
| Work Area Dimensions (W×D×H) | 1230 × 600 × 550 mm (TCB-4E1-CN), 1840 × 600 × 550 mm (TCB-6E1-CN) |
| Overall Dimensions with Stand (W×D×H) | 1340 × 685 × 1810 mm (TCB-4E1-CN), 1950 × 685 × 1810 mm (TCB-6E1-CN) |
| Work Surface Area | 0.74 m² (TCB-4E1-CN), 1.10 m² (TCB-6E1-CN) |
| Initial Air Velocity | 0.30–0.45 m/s (adjustable) |
| Air Exchange Volume (at 0.35 m/s) | 705 m³/h (TCB-4E1-CN), 1066 m³/h (TCB-6E1-CN) |
| HEPA Filter Efficiency | ≥99.99% for particles >0.3 µm |
| Cleanroom Class | ISO 5 (equivalent to Fed. Std. 209E Class 100) |
| Noise Level | <65 dBA |
| Illumination | >900 lux |
| UV Lamp | Standard timer-based scheduling |
| Construction | 1.0 mm cold-rolled steel housing with Esco IsoCide™ antimicrobial epoxy-phenolic coating |
| Work Chamber Interior | 1.0 mm 304 stainless steel work surface and sidewalls |
| Side Panels | 5 mm UV-blocking tempered glass |
| Power Supply | 220–240 V, 50 Hz, single-phase, 5 A |
| Compliance | YY/T 1539–2017, JG/T 292–2010, AS 1386.5, IEST-RP-CC002.2, ISO 14644-1 |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SCR-2A1 |
| Pricing | Upon Request |
| External Dimensions (L×W×H) | 730 × 617 × 950 mm |
| Internal Dimensions (L×W×H) | 630 × 538 × 550 mm |
| Airflow Velocity | 0.275–0.325 m/s |
| Power Supply | 230 VAC, 50 Hz |
| Brand | ESCO/Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SCI Series |
| Pricing | Upon Request |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VBD-4A1 |
| Price | Upon Request |
| External Dimensions (L×W×H) | 1247 × 760 × 1966–2271 mm |
| Internal Dimensions (L×W×H) | 1040 × 680 × 594 mm |
| Inflow Air Velocity | 0.35 m/s |
| Power Supply | 220–240 VAC, 50 Hz |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VDA-A |
| Pricing | Available Upon Request |
| External Dimensions (L×W×H) | 1340 × 762 × 1961 mm (Low-Height Configuration) / 1340 × 762 × 2245 mm (High-Height Configuration) |
| Internal Work Area (L×W×H) | 1100 × 465 × 564 mm |
| Downflow Air Velocity | 0.24 m/s (47 fpm) |
| Power Supply | 220–240 VAC, 50/60 Hz, Single-Phase |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Model | VA2-A1-E |
| External Dimensions (L×W×H) | 1423 × 815 × 1510 mm |
| Internal Work Area (L×W×H) | 1270 × 623 × 680 mm |
| Inflow Velocity | 0.45 m/s |
| Downflow Velocity | 0.35 m/s |
| Power Supply | 220–240 VAC, 50/60 Hz |
| Filtration | Dual ULPA (≥99.999% @ 0.12 µm MPPS) |
| Pre-filter | Polyester pleated, 85% arrestance |
| Compliance | ISO 14644-1 Class 3 (equivalent to Fed Std 209E Class 1), NSF/ANSI 49 compliant design principles, GLP-aligned operational safeguards |
| Brand | ESI |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | LabStation |
| Pricing | Upon Request |
| Brand | ESI |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | TRAXStation |
| Pricing | Available Upon Request |
| Brand | EXPEC |
|---|---|
| Model | ETV 720 |
| Origin | Zhejiang, China |
| Type | Solid Direct Introduction Electrothermal Vaporization System |
| Max Temp | 3000 °C (infrared non-contact detection + PID control) |
| Sample Capacity | 40 boats |
| Motion Control | Micrometer-level precision positioning |
| Gas Flow Control | Milliliter-level accuracy |
| Automation | Fully automated sample loading, insertion, and thermal program execution |
| Compliance | Designed for ISO/IEC 17025-aligned workflows, compatible with GLP/GMP data integrity requirements |
| Brand | EURO TECH |
|---|---|
| Origin | Shanghai, China |
| Model | ET3303 |
| Sample Capacity | 12 positions (compatible with 50 mL and 200 mL glass tubes) |
| Temperature Range | Ambient to 60 °C |
| Gas Pressure Range | 0–25 psi (adjustable) |
| Endpoint Detection Options | 0.5 mL or 1.0 mL (optical sensor-based) |
| Display | 8-inch capacitive touchscreen |
| Power Supply | 220 VAC, 50 Hz |
| Dimensions (W×H×D) | 54 cm × 31 cm × 35 cm |
| Net Weight | 25 kg |
| Exhaust Duct | 5.1 cm ID × 3.0 m length included |
| Timer Range | 1–999 minutes |
| Gas Inlet Requirement | Minimum 40 psi supply pressure, regulated to ≤100 psi maximum |
| Brand | EuroTech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ET3301B |
| Price Range | USD 7,000 – 14,000 |
| Sample Capacity | Up to 60 positions |
| Water Bath Temperature Range | Ambient to 95 °C |
| Timer Range | 1–999 minutes |
| Gas Inlet Pressure | 60–100 psi |
| Nitrogen Flow per Nozzle | Up to 2 L/min |
| Flow Control | Digital Pressure-Regulated |
| Independent Channels | 6 |
| Display | 7-inch LCD touchscreen |
| Dimensions (W×H×D) | 54 × 31 × 35 cm |
| Net Weight | 25 kg |
| Power Supply | 230 V, 50 Hz (optional 110 V, 60 Hz) |
| Brand | EWIN-TECH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM/ODM) |
| Country of Origin | China |
| Model | HA-300 |
| Pressure Rating | 3–5 MPa |
| Construction Material | 316L Stainless Steel Endplates, Nickel-Plated Flow Field Plates |
| Fluid Configuration | Single-Side Inlet/Outlet (Bottom-In/Top-Out) |
| Active Area | Customizable |
| Interface | Open Mechanical & Electrical Interface for User-Provided MEA/GDL |
| Compliance | Designed for ASTM D7284, ISO 22742, and IEC 62282-6-100-aligned test protocols |
| Brand | EWIN-TECH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | HC-100 |
| Material | PEEK + 316L Stainless Steel + PFA |
| Active Area | 0.5 cm² |
| Operating Temperature Range | Ambient to 95 °C |
| Relative Humidity Control | Up to 100 % RH |
| Gas Supply Interface | Standardized mass flow-controlled O₂ inlet |
| Electrolyte Compatibility | Acidic (e.g., 0.1 M HClO₄, 0.5 M H₂SO₄) and alkaline media |
| Three-Phase Interface Design | Gas–Solid–Liquid |
| Compliance | Designed for ASTM D7212, ISO 23841, and fuel cell catalyst R&D workflows per DOE Hydrogen Program Targets |
| Brand | EWIN-TECH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | HC-100H |
| Pricing | Upon Request |
| Construction Materials | PEEK + ASTM F138 Grade 316L Stainless Steel |
| Operating Temperature Range | 25–95 °C |
| Relative Humidity Control | 0–100% RH (Auto-humidification via integrated water vapor diffusion manifold) |
| Compatible Electrode Formats | GDEs up to 5 cm² active area |
| Measurement Capabilities | Polarization curve acquisition, electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), chronoamperometry (CA) |
| Fluidic Interface | Dual gas inlets (anode/cathode), liquid water injection ports, integrated pressure regulation (0–300 kPa gauge) |
| Compliance | Designed per ISO 8502-3 (surface cleanliness), ASTM D7234 (adhesion testing for coated substrates), and compatible with GLP-compliant test protocols |
| Brand | EWIN-TECH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | HM-200 |
| Pricing | Available Upon Request |
| Compatible MEA Size | 5 cm × 5 cm (customizable active area & flow field pattern) |
| End Plates | 316L stainless steel |
| Current Collectors | Gold-plated copper |
| Bipolar Plates | Graphite |
| Sealing | Viton® gaskets |
| Max Operating Pressure | 3 bar (gauge) |
| Max Operating Temperature | 80 °C |
| Electrical Contact Resistance | < 5 mΩ (typical, under 1.5 MPa clamping force) |
| Brand | EWIN-TECH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | HM-200H |
| Pricing | Available Upon Request |
| Humidity Control | Integrated 100% RH self-humidification module |
| MEA Active Area | 5 cm × 5 cm (standard) |
| Flow Field Options | Customizable (serpentine, interdigitated, parallel) |
| End Plate Material | 316L stainless steel |
| Current Collector | Gold-plated copper |
| Bipolar Plate Material | Graphite |
| Electrical Connection | Four-terminal Kelvin sensing compatible |
| Operating Temperature Range | 25–80 °C (ambient to mild thermal control support) |
| Brand | EWIN-TECH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | HP-300 |
| Temperature Range | RT+5°C to 90°C |
| Maximum Operating Pressure | 3–5 MPa |
| Flow Configuration | Bottom-in/Top-out (single-sided) |
| Customization | Active Area, Flow Field Design, Core Material |
| Brand | EWIN-TECH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | PCT-100 |
| Pricing | Available Upon Request |
| Actuation | Pneumatic |
| Pressure Control | Closed-loop regulated |
| Active Area Compatibility | ≤25 cm² |
| Modular Design | Interchangeable flow field plates |
| Optional Modules | In-situ compression monitoring, current distribution mapping, temperature-controlled platens |
| Brand | EXPEC (Hangzhou Superspectra Technology Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 270 |
| Dilution Range | Up to 10,000× |
| Number of Independent Channels | 6 |
| Pressure Measurement Principle | Absolute Pressure Transducers |
| Dead Volume | Minimized via Optimized Flow Path Design |
| Tubing Material | Chemically Inert, Passivated Stainless Steel |
| Optional Module | Humidification Kit for Calibration Gas |
| Control Interface | Integrated Tablet via Wi-Fi (No External PC Required) |
| Data Management | Local Storage with Label Printing Support |
| Brand | EXPEC (Puyu Technology) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 271 |
| Sampling Principle | Negative-Pressure Passive Draw |
| Flow Range | 0.2–500 mL/min |
| Response Time for Instantaneous Retention | ≤60 s after threshold exceedance |
| Channel Configuration | Dual independent sampling channels |
| Standard Sampling Positions | 8 (expandable to 16) |
| Flow Path Treatment | Electropolished stainless steel with SilcoNert®/Sulfinert® inert coating and active heating (60–120 °C) |
| Compliance | Designed to meet HJ 759–2015 requirements for ambient VOC monitoring |
| Brand | EXPEC (Furui Technology) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 272 |
| Sample Capacity | 16 positions standard, expandable to 48 positions (3 × 16) |
| Sample Types | Electropolished SUMMA canisters (6–30 L), gas sampling bags (Tedlar®, FlexFoil®), and crimp-top or screw-cap sampling vials |
| Flow Path | Fully inertized (SilcoNert®/Sulfinert®-treated stainless steel), heated to 110 °C ± 5 °C |
| Automation Functions | Automated leak check (pressure decay method), flow path purge & bake-out, sequence-based auto-injection |
| Compliance | Designed for EPA Method TO-14A, TO-15A, ASTM D6196, and ISO 16017-1 workflows |