Other Environmental Monitoring Instruments
Filter
Showing 691–720 of 1329 results
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6720-DP Grid |
| Instrument Type | Pitot Tube Anemometer |
| Resolution | 0.01 m/s (air velocity), 1 m³/h (airflow), 0.001 Pa (differential pressure) |
| Measurement Range | 0.15–40 m/s (pitot tube), 0.15–15 m/s (grid sensor), −2500–2500 Pa (dP), 40–4300 m³/h (airflow) |
| Accuracy | ±3% ±0.05 m/s (>0.25 m/s, air velocity), ±3% ±8 m³/h (>85 m³/h, airflow), ±1.5% ±0.25 Pa (differential pressure) |
| Operating Temperature | 0–60 °C (non-condensing) |
| Operating Humidity | 0–100 %RH |
| Display | 4.3-inch full-color capacitive touchscreen |
| Data Storage | 8,000 records (device), 10,000 records (mobile app) |
| Battery Life | ~14 hours (4 × AA alkaline batteries) |
| Weight | ~3.6 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6720-DP Grid |
| Instrument Type | Pitot Tube Anemometer |
| Velocity Range | 0.15–40 m/s (Pitot Tube), 0.15–15 m/s (Grid Probe) |
| Differential Pressure Range | −2500 to +2500 Pa |
| Velocity Resolution | 0.01 m/s |
| DP Resolution | 0.001 Pa |
| Velocity Accuracy | ±3% of reading ±0.05 m/s (>0.25 m/s) |
| DP Accuracy | ±1.5% of reading ±0.25 Pa |
| Airflow Range | 40–4300 m³/h |
| Airflow Accuracy | ±3% of reading ±8 m³/h (>85 m³/h) |
| Airflow Resolution | 1 m³/h |
| Operating Temperature | 0–60 °C (non-condensing) |
| Operating Humidity | 0–100 %RH |
| Display | 4.3-inch full-color touchscreen |
| Data Storage | 8,000 records (instrument), 10,000 records (mobile app) |
| Battery Life | ~14 h (4 × AA alkaline) |
| Weight | ~3.6 kg |
| Connectivity | Bluetooth 4.2, USB 2.0 |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6750 |
| Resolution | 1 m³/h |
| Measurement Range | ±8–600 m³/h |
| Accuracy | ±(3% of reading + 1 m³/h) for 8–350 m³/h |
| Operating Temperature | 0–50 °C |
| Operating Humidity | 0–100 %RH |
| Display | Full-color TFT LCD with transparent viewing window |
| Connectivity | Bluetooth 4.2 (BLE) for wireless data transmission |
| Power Supply | Rechargeable Li-ion battery (up to 8 h continuous operation) |
| Compliance | CE, RoHS, JIS B 8623 (Air Flow Measuring Instruments) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6750+ |
| Resolution | 1 m³/h |
| Measurement Range | ±8–600 m³/h |
| Accuracy | ±(3% of reading + 1 m³/h) for 8–350 m³/h |
| Operating Temperature | 0–50 °C |
| Operating Humidity | 0–100 %RH |
| Display | 160×80 mm color LCD |
| Data Storage | Up to 6,000 records (internal) |
| Communication | Bluetooth v4.0, USB output |
| Power | 4 × AA batteries or AC adapter |
| Battery Life | Approx. 8 hours |
| Dimensions (hood) | 355(W)×355(H)×450(D) mm |
| Hood Aperture | 355×355 mm |
| Weight | 1.5 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6750 |
| Resolution | 1 m³/h |
| Flow Range | ±8–600 m³/h |
| Accuracy | ±(3% of reading + 1 m³/h) for 8–350 m³/h |
| Operating Temperature | 0–50 °C |
| Operating Humidity | 0–100 %RH |
| Temperature Measurement Range | 0–50 °C |
| Temperature Accuracy | ±0.5 °C |
| Display | Dual-parameter (airflow + temperature), battery level, unit toggle (m³/h / CFM, °C), on-device data processing |
| Communication | Bluetooth 4.0, USB output |
| Data Storage | Up to 6,000 records (internal memory) |
| Power | 4 × AA alkaline batteries or AC adapter |
| Battery Life | Approx. 8 hours continuous operation |
| Dimensions (Hood) | 355 × 355 × 450 mm (W×H×D) |
| Hood Aperture | 355 × 355 mm |
| Display Module | 160 × 80 × 45 mm |
| Weight | 1.5 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6750 |
| Instrument Type | Pitot-Static Air Flow Hood |
| Flow Range | ±8–600 m³/h |
| Accuracy | ±(3% of reading + 1 m³/h) for 8–350 m³/h |
| Temperature Range | 0–50 °C |
| Temp. Accuracy | ±0.5 °C |
| Display | 160×80 mm full-color LCD |
| Data Storage | 6,000 records (internal) |
| Connectivity | Bluetooth 4.0, USB output |
| Power | 4 × AA batteries or AC adapter |
| Operating Time | ~8 hours |
| Dimensions (hood) | 355 × 355 × 450 mm (W×H×D) |
| Weight | 1.5 kg |
| Probe Material | Fiberglass support rod |
| Compliance | Designed for HVAC commissioning per ASHRAE 111, ISO 16813, and EN 12599 |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 6822 / 6824 |
| Instrument Type | Vane Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.2–20.0 m/s |
| Accuracy | ±3% of reading or ±0.1 m/s (whichever is greater) |
| Operating Temperature | −20 to +100 °C |
| Operating Humidity | 5.0–95.0 %RH |
| Temperature Accuracy | ±1.0 °C |
| Probe Diameter | 70 mm |
| Power Supply | 3 × AA batteries |
| Battery Life | Approx. 150 hours |
| Dimensions (W×H×D) | 81 × 165 × 38 mm |
| Weight | 175 g (including batteries) |
| Air Volume Range | 0–9,999 CFM |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3000-0C |
| Compliance | GB 2626–2019, GB 19083–2010, OSHA 1910.134, CSA Z94.4, ISO 16900-1 |
| Test Method | Controlled Negative Pressure (CNP) / Ambient Aerosol Condensation Nucleus Counting (CNC) |
| Supported Respirator Types | Disposable particulate respirators (N95, KN95, KP95, N99, KN100), half-mask and full-face elastomeric respirators, PAPRs, surgical masks (for qualitative/quantitative fit assessment) |
| Language Interface | English, French, German, Spanish, Japanese |
| Connectivity | USB 2.0, Ethernet (10/100BASE-T), Wi-Fi 802.11 b/g/n |
| Multi-unit Control | Up to 4 units via single PC |
| Data Management | Audit-trail enabled, GLP-compliant export (CSV, PDF), optional 21 CFR Part 11 software module |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | AccuFIT 9000 |
| Particle Detection Method | Condensation Particle Counter (CPC) |
| Particle Size Range | 0.02–1.0 µm |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Calculation | Direct Cout/Cin Ratio |
| Challenge Agent | ≥99.5% Isopropanol or Ethanol |
| Display | 7-inch Full-Color Touchscreen (Chinese, English, Japanese, French, Spanish, Portuguese) |
| Compliance Standards | OSHA 1910.134, CSA Z94.4, ANSI/AIHA Z88.10, UK HSE INDG479, GB 19083–2010, GB 2626–2019, GB/T 32610–2016 |
| Data Interface | USB, Ethernet, Wi-Fi |
| Software Control | Single PC manages up to 4 units simultaneously |
| Operating Environment | 10–35°C, 20–85% RH (non-condensing) |
| Dimensions | 208 × 117 × 262 mm (W×H×D) |
| Weight | 2.3 kg |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | AccuFIT 9000 |
| Compliance | GB 2626–2019, GB 19083–2010, OSHA 1910.134, CSA Z94.4, ISO 16900-1/3 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | AccuFIT 9000 |
| Compliance | GB 2626–2019, GB 19083–2010, OSHA 29 CFR 1910.134, CSA Z94.4, NIOSH-approved fit test protocols |
| Test Method | Controlled Negative Pressure (CNP) / Ambient Aerosol Condensation Nucleus Counting (CNC) |
| Supported Respirator Types | Disposable particulate respirators (N95, KN95, KP95, N99, KN100), half-face and full-face elastomeric respirators, PAPRs (with appropriate adapters) |
| Language Interface | English, French, German, Spanish, Japanese |
| Connectivity | USB 2.0, Ethernet (10/100 Mbps), Wi-Fi 802.11 b/g/n |
| Multi-unit Control | Up to 4 units via single PC |
| Data Output | CSV, PDF reports with audit trail |
| Software | AccuFIT Manager v4.x (Windows 10/11, 64-bit) |
| Regulatory Support | FDA 21 CFR Part 11 compliant configuration available (electronic signatures, audit trail, user access control) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | AccuFIT 9000 |
| Compliance | GB 2626–2019, GB 19083–2010, OSHA 29 CFR 1910.134, CSA Z94.4, NIOSH-approved fit test protocols |
| Test Method | Controlled Negative Pressure (CNP) / Ambient Aerosol Condensation Nucleus Counting (CNC) |
| Supported Respirator Types | Disposable particulate respirators (N95, KN95, KP95, N100, KN100), half-face and full-face elastomeric respirators, powered air-purifying respirators (PAPRs) |
| TIL (Total Inward Leakage) Evaluation Basis | Per-test subject (10-subject panel), per-operation (5 operations × 10 subjects), pass thresholds per standard (e.g., KN95/KP95: TIL < 8% for ≥8 of 10 subjects) |
| Interface Options | USB 2.0, Ethernet, Wi-Fi (IEEE 802.11 b/g/n), multi-language UI (English, Chinese, Japanese, Korean, Spanish) |
| Software Control | Standalone operation or PC-synchronized control (up to 4 units per host) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3000-0C |
| Compliance | GB 2626–2019, GB 19083–2010, OSHA 29 CFR 1910.134, CSA Z94.4, EN 13274-1/EN 13274-7 |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | Dependent on Interchangeable Probe (e.g., 0.05–30 m/s for standard hot-wire probe) |
| Accuracy | ±2% of reading |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 2.0–98.0% RH |
| Data Storage Capacity | Up to 20,000 records |
| Probe Interface | Standardized 8-pin detachable connector supporting eight interchangeable probe types |
| Built-in Calculations | Volumetric airflow (m³/h, CFM) via user-defined duct geometry (rectangular, circular, oval cross-sections with dimensional input) |
| On-device Statistics | Real-time min/max/average of velocity, temperature, humidity, and pressure |
| Data Hold & Recall | Instant freeze-display and historical retrieval |
| Accessories Included | 2 m probe cable ×1, carrying case ×1, operation manual ×1 |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | T6900 |
| Flow Range (Matrix) | 36–640 m³/h |
| Flow Range (Nozzle) | 4–36 m³/h |
| Flow Accuracy | ±2.5% of reading ±0.1 m³/h |
| Flow Resolution | 0.01 m³/h |
| Static Pressure Range | ±2500 Pa |
| Pressure Accuracy | ±1% of reading ±1 Pa |
| Pressure Resolution | 0.1 Pa |
| Temperature Range | 0–60 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Barometric Pressure Range | 70–130 kPa |
| Barometric Accuracy | ±2% of reading |
| Barometric Resolution | 0.1 kPa |
| Power Supply | DALT6900-0E: 110–120 V, 1Φ, 50/60 Hz, 16 A |
| DALT6900-1E | 220–240 V, 1Φ, 50/60 Hz, 10 A |
| Net Weight | ~72 kg |
| Dimensions (W×D×H) | 54 × 50 × 120 cm |
| Data Storage | 1000 test records |
| Display | 5-inch color LCD touchscreen |
| Compliance Standards | EN 1507:2006, EN 12237:2002, Eurovent 2/2, DW/143, SMACNA HVAC Air Duct Leakage Testing Standard, GB 50243–2002 |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DAL T6900 |
| Price | Upon Request |
| Flow Range | 36–640 m³/h (main duct) / 4–36 m³/h (nozzle bank) |
| Accuracy | ±2.5% of reading ±0.1 m³/h (flow), ±1% of reading ±1 Pa (static pressure), ±0.5 °C (temperature), ±2% of reading (atmospheric pressure) |
| Resolution | 0.01 m³/h (flow), 0.1 Pa (pressure), 0.1 °C (temperature), 0.1 kPa (atmospheric pressure) |
| Static Pressure Range | ±2500 Pa |
| Temperature Range | 0–60 °C |
| Atmospheric Pressure Range | 70–130 kPa |
| Power Supply | DAL T6900-0E: 110–120 V, 1-phase, 50/60 Hz, 16 A |
| DAL T6900-1E | 220–240 V, 1-phase, 50/60 Hz, 10 A |
| Net Weight | ~72 kg |
| Dimensions | 540 × 500 × 1200 mm |
| Data Storage | 1000 test records |
| Display | 4.7-inch color LCD touchscreen |
| Compliance Standards | EN 1507:2006, EN 12237:2002, Eurovent 2/2, DW/143, SMACNA HVAC Air Duct Leakage Testing Standard, GB 50243–2002 |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DAL T6900 |
| Flow Range | 36–640 m³/h (nozzle mode: 4–36 m³/h) |
| Accuracy | ±2.5% of reading ±0.1 m³/h (flow), ±1% of reading ±1 Pa (static pressure), ±0.5 °C (temperature), ±2% of reading (atmospheric pressure) |
| Resolution | 0.01 m³/h (flow), 0.1 Pa (pressure), 0.1 °C (temperature), 0.1 kPa (atmospheric pressure) |
| Static Pressure Range | ±2500 Pa |
| Temperature Range | 0–60 °C |
| Atmospheric Pressure Range | 70–130 kPa |
| Power Supply | DAL T6900-0E: 110–120 V, 1-phase, 50/60 Hz, 16 A |
| DAL T6900-1E | 220–240 V, 1-phase, 50/60 Hz, 10 A |
| Net Weight | ~72 kg |
| Dimensions | 540 × 500 × 1200 mm |
| Data Storage | 1000 test records |
| Display | 4.7-inch color LCD touchscreen |
| Compliance Standards | EN 1507:2006, EN 12237:2002, Eurovent 2/2, DW/143, SMACNA HVAC Air Duct Leakage Testing Standard, GB 50243–2002 |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DAL T6900 |
| Flow Range | 36–640 m³/h (nozzle range: 4–36 m³/h) |
| Accuracy | ±2.5% of reading ±0.1 m³/h (flow), ±1% of reading ±1 Pa (static pressure), ±0.5 °C (temperature), ±2% of reading (atmospheric pressure) |
| Resolution | 0.01 m³/h (flow), 0.1 Pa (pressure), 0.1 °C (temperature), 0.1 kPa (atmospheric pressure) |
| Static Pressure Range | ±2500 Pa |
| Temperature Range | 0–60 °C |
| Atmospheric Pressure Range | 70–130 kPa |
| Power Supply | DAL T6900-0E: 110–120 V, 1-phase, 50/60 Hz, 16 A |
| DAL T6900-1E | 220–240 V, 1-phase, 50/60 Hz, 10 A |
| Net Weight | ~72 kg |
| Dimensions | 540 × 500 × 1200 mm |
| Data Storage | 1000 test records |
| Display | 4.7-inch color LCD touchscreen |
| Compliance Standards | EN 1507:2006, EN 12237:2002, Eurovent 2/2, DW/143, SMACNA HVAC Air Duct Leakage Testing Standard, GB 50243–2002 |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DAL T6900 |
| Flow Range (Matrix) | 36–640 m³/h |
| Flow Range (Nozzle) | 4–36 m³/h |
| Flow Accuracy | ±2.5% of reading ±0.1 m³/h |
| Flow Resolution | 0.01 m³/h |
| Static Pressure Range | ±2500 Pa |
| Pressure Accuracy | ±1% of reading ±1 Pa |
| Pressure Resolution | 0.1 Pa |
| Temperature Range | 0–60 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Barometric Pressure Range | 70–130 kPa |
| Barometric Accuracy | ±2% of reading |
| Barometric Resolution | 0.1 kPa |
| Power Supply | DAL T6900-0E: 110–120 V, 1φ, 50/60 Hz, 16 A |
| DAL T6900-1E | 220–240 V, 1φ, 50/60 Hz, 10 A |
| Net Weight | ~72 kg |
| Dimensions (W×D×H) | 54 × 50 × 120 cm |
| Data Storage Capacity | 1000 test records |
| Brand | Kanomax |
|---|---|
| Origin | China (Liaoning) |
| Model | DALT 6900 |
| Airflow Range | 36–640 m³/h (nozzle range: 4–36 m³/h) |
| Accuracy | ±2.5% of reading ±0.1 m³/h (airflow), ±1% of reading ±1 Pa (static pressure) |
| Resolution | 0.01 m³/h (airflow), 0.1 Pa (pressure), 0.1 °C (temperature), 0.1 kPa (atmospheric pressure) |
| Static Pressure Range | ±2500 Pa |
| Temperature Range | 0–60 °C |
| Atmospheric Pressure Range | 70–130 kPa |
| Power Supply | DALT 6900-0E: 110–120 V, 1Φ, 50/60 Hz, 16 A |
| DALT 6900-1E | 220–240 V, 1Φ, 50/60 Hz, 10 A |
| Weight | ~72 kg |
| Dimensions | 540 × 500 × 1200 mm |
| Data Storage | 1000 test records |
| Display | 4.7-inch color LCD touchscreen |
| Brand | Kanomax |
|---|---|
| Model | DAL.T6900 |
| Origin | China (Liaoning) |
| Power Supply | DAL.T6900-0E: 110–120 V, 1-phase, 50/60 Hz, 16 A |
| DAL.T6900-1E | 220–240 V, 1-phase, 50/60 Hz, 10 A |
| Airflow Range | 36–640 m³/h (main duct) |
| Accuracy | ±2.5% of reading ±0.1 m³/h (airflow) |
| Resolution | 0.01 m³/h (airflow) |
| Static Pressure Range | ±2500 Pa |
| Temperature Range | 0–60 °C |
| Atmospheric Pressure Range | 70–130 kPa |
| Data Storage | 1000 test records |
| Display | 4.7-inch color LCD touchscreen |
| Dimensions (W×D×H) | 540 × 500 × 1200 mm |
| Net Weight | ~72 kg |
| Brand | Kanomax |
|---|---|
| Model | DALT-6905 |
| Flow Range (Large Nozzle) | 70–820 m³/h |
| Flow Range (Small Nozzle) | 4–70 m³/h |
| Flow Accuracy | ±2.5% of reading ±0.1 m³/h |
| Flow Resolution | 0.01 m³/h |
| Static Pressure Range | ±2500 Pa |
| Pressure Accuracy | ±1% of reading ±1 Pa |
| Pressure Resolution | 0.1 Pa |
| Temperature Range | 0–60 °C |
| Temp Accuracy | ±0.5 °C |
| Temp Resolution | 0.1 °C |
| Atmospheric Pressure Range | 70–130 kPa |
| Atmos. Pressure Accuracy | ±2% of reading |
| Atmos. Pressure Resolution | 0.1 kPa |
| Power Supply | 100–120 V / 200–240 V, 1-phase, 50/60 Hz |
| Net Weight | 59.8 kg |
| Dimensions (W×D×H) | 480 × 627 × 1124 mm |
| Data Storage | 1000 test records |
| Display | 5-inch color LCD touchscreen |
| Compliance Standards | EN 1507:2006, EN 12237:2003, Eurovent 2/2, DW/143, SMACNA, AABC, GB 50243–2002/2016 |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DALT6900 |
| Flow Range | 36–640 m³/h (nozzle range: 4–36 m³/h) |
| Accuracy | ±2.5% of reading ±0.1 m³/h (flow), ±1% of reading ±1 Pa (static pressure), ±0.5 °C (temperature), ±2% of reading (atmospheric pressure) |
| Resolution | 0.01 m³/h (flow), 0.1 Pa (pressure), 0.1 °C (temperature), 0.1 kPa (atmospheric pressure) |
| Static Pressure Range | ±2500 Pa |
| Temperature Range | 0–60 °C |
| Atmospheric Pressure Range | 70–130 kPa |
| Power Supply | DALT6900-0E: 110–120 V, 1Φ, 50/60 Hz, 16 A |
| DALT6900-1E | 220–240 V, 1Φ, 50/60 Hz, 10 A |
| Net Weight | ~72 kg |
| Dimensions | 540 × 500 × 1200 mm |
| Data Storage | 1000 test records |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DALT6900 |
| Flow Range | 36–640 m³/h (nozzle range: 4–36 m³/h) |
| Accuracy | ±2.5% of reading ±0.1 m³/h (flow), ±1% of reading ±1 Pa (static pressure), ±0.5 °C (temperature), ±2% of reading (atmospheric pressure) |
| Resolution | 0.01 m³/h (flow), 0.1 Pa (pressure), 0.1 °C (temperature), 0.1 kPa (atmospheric pressure) |
| Static Pressure Range | ±2500 Pa |
| Temperature Range | 0–60 °C |
| Atmospheric Pressure Range | 70–130 kPa |
| Power Supply | DALT6900-0E: 110–120 V, 1-phase, 50/60 Hz, 16 A |
| DALT6900-1E | 220–240 V, 1-phase, 50/60 Hz, 10 A |
| Weight | ~72 kg |
| Dimensions | 540 × 500 × 1200 mm |
| Data Storage | 1000 test records |
| Display | 4.7-inch color LCD touchscreen |
| Compliance Standards | EN 1507:2006, EN 12237:2002, Eurovent 2/2, DW/143, SMACNA HVAC Air Duct Leakage Testing Standard, GB 50243–2002 |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DALT6900 |
| Flow Range | 36–640 m³/h (nozzle mode: 4–36 m³/h) |
| Accuracy | ±2.5% of reading ±0.1 m³/h (flow), ±1% of reading ±1 Pa (static pressure), ±0.5 °C (temperature), ±2% of reading (atmospheric pressure) |
| Resolution | 0.01 m³/h (flow), 0.1 Pa (pressure), 0.1 °C (temperature), 0.1 kPa (atmospheric pressure) |
| Static Pressure Range | ±2500 Pa |
| Temperature Range | 0–60 °C |
| Atmospheric Pressure Range | 70–130 kPa |
| Power Supply | DALT6900-0E: 110–120 V, 1Φ, 50/60 Hz, 16 A |
| DALT6900-1E | 220–240 V, 1Φ, 50/60 Hz, 10 A |
| Weight | ~72 kg |
| Dimensions | 540 × 500 × 1200 mm |
| Data Storage | 1000 test records |
| Display | 4.7-inch color LCD touchscreen |
| Compliance Standards | EN 1507:2006, EN 12237:2002, Eurovent 2/2, DW/143, SMACNA HVAC Air Duct Leakage Testing Standard, GB 50243–2002 |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DALT6900 |
| Flow Range | 36–640 m³/h (nozzle range: 4–36 m³/h) |
| Accuracy | ±2.5% of reading ±0.1 m³/h (flow), ±1% of reading ±1 Pa (static pressure), ±0.5 °C (temperature), ±2% of reading (atmospheric pressure) |
| Resolution | 0.01 m³/h (flow), 0.1 Pa (pressure), 0.1 °C (temperature), 0.1 kPa (atmospheric pressure) |
| Static Pressure Range | ±2500 Pa |
| Temperature Range | 0–60 °C |
| Atmospheric Pressure Range | 70–130 kPa |
| Power Supply | DALT6900-0E: 110–120 V, 1-phase, 50/60 Hz, 16 A |
| DALT6900-1E | 220–240 V, 1-phase, 50/60 Hz, 10 A |
| Net Weight | ~72 kg |
| Dimensions | 540 × 500 × 1200 mm |
| Data Storage | 1000 test records |
| Display | 4.7-inch color LCD touchscreen |
| Compliance Standards | EN 1507:2006, EN 12237:2002, Eurovent 2/2, DW/143, SMACNA HVAC Air Duct Leakage Testing Standard, GB 50243–2002 |
| Brand | KANOMAX |
|---|---|
| Model | DALT6900 |
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Flow Range | 36–640 m³/h (main duct), 4–36 m³/h (nozzle bank) |
| Accuracy | ±2.5% of reading ±0.1 m³/h (flow), ±1% of reading ±1 Pa (static pressure), ±0.5 °C (temperature), ±2% of reading (atmospheric pressure) |
| Resolution | 0.01 m³/h (flow), 0.1 Pa (pressure), 0.1 °C (temperature), 0.1 kPa (atmospheric pressure) |
| Static Pressure Range | ±2500 Pa |
| Temperature Range | 0–60 °C |
| Atmospheric Pressure Range | 70–130 kPa |
| Power Supply | DALT6900-0E: 110–120 V, 1Φ, 50/60 Hz, 16 A |
| DALT6900-1E | 220–240 V, 1Φ, 50/60 Hz, 10 A |
| Dimensions | 540 × 500 × 1200 mm |
| Net Weight | ~72 kg |
| Data Storage | 1000 test records |
| Display | 4.7-inch color LCD touchscreen |
| Compliance Standards | EN 1507:2006, EN 12237:2002, Eurovent 2/2, DW/143, SMACNA HVAC Air Duct Leakage Testing Standard, GB 50243–2002 |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DALT6900 |
| Price | Upon Request |
| Flow Range | 36–640 m³/h (nozzle range: 4–36 m³/h) |
| Accuracy | ±2.5% of reading ±0.1 m³/h |
| Resolution | 0.01 m³/h |
| Static Pressure Range | ±2500 Pa |
| Pressure Accuracy | ±1% of reading ±1 Pa |
| Pressure Resolution | 0.1 Pa |
| Temperature Range | 0–60 °C |
| Temp Accuracy | ±0.5 °C |
| Temp Resolution | 0.1 °C |
| Barometric Pressure Range | 70–130 kPa |
| Baro Accuracy | ±2% of reading |
| Baro Resolution | 0.1 kPa |
| Power Supply | DALT6900-0E: 110–120 V, 1-phase, 50/60 Hz, 16 A |
| DALT6900-1E | 220–240 V, 1-phase, 50/60 Hz, 10 A |
| Net Weight | ~72 kg |
| Dimensions | 540 × 500 × 1200 mm |
| Data Storage | 1000 test records |
| Display | 4.7-inch color LCD touchscreen |
| Compliance Standards | EN 1507:2006, EN 12237:2002, Eurovent 2/2, DW/143, SMACNA HVAC Air Duct Leakage Testing Standard, GB 50243–2002 |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | DALT6900 |
| Price | Upon Request |
| Flow Range | 36–640 m³/h (nozzle range: 4–36 m³/h) |
| Accuracy | ±2.5% of reading ±0.1 m³/h |
| Resolution | 0.01 m³/h |
| Static Pressure Range | ±2500 Pa |
| Pressure Accuracy | ±1% of reading ±1 Pa |
| Pressure Resolution | 0.1 Pa |
| Temperature Range | 0–60 °C |
| Temp Accuracy | ±0.5 °C |
| Temp Resolution | 0.1 °C |
| Barometric Range | 70–130 kPa |
| Baro Accuracy | ±2% of reading |
| Baro Resolution | 0.1 kPa |
| Power Supply | DALT6900-0E: 110–120 V, 1Φ, 50/60 Hz, 16 A |
| DALT6900-1E | 220–240 V, 1Φ, 50/60 Hz, 10 A |
| Net Weight | ~72 kg |
| Dimensions | 540 × 500 × 1200 mm |
| Data Storage | 1000 test records |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DALT6900 |
| Flow Range | 36–640 m³/h (nozzle range: 4–36 m³/h) |
| Accuracy | ±2.5% of reading ±0.1 m³/h (flow), ±1% of reading ±1 Pa (static pressure), ±0.5 °C (temperature), ±2% of reading (atmospheric pressure) |
| Resolution | 0.01 m³/h (flow), 0.1 Pa (pressure), 0.1 °C (temperature), 0.1 kPa (atmospheric pressure) |
| Static Pressure Range | ±2500 Pa |
| Temperature Range | 0–60 °C |
| Atmospheric Pressure Range | 70–130 kPa |
| Power Supply | DALT6900-0E: 110–120 V, 1-phase, 50/60 Hz, 16 A |
| DALT6900-1E | 220–240 V, 1-phase, 50/60 Hz, 10 A |
| Weight | ~72 kg |
| Dimensions | 540 × 500 × 1200 mm |
| Data Storage | 1000 test records |
| Display | 4.7-inch color LCD touchscreen |
| Compliance Standards | EN 1507:2006, EN 12237:2002, Eurovent 2/2, DW/143, SMACNA HVAC Air Duct Leakage Testing Standard, GB 50243–2002 |