| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | PEN3-meteo |
| Compliance | EN 13725:2003 |
| Detection Principle | Metal Oxide Semiconductor (MOS) Sensor Array with Multivariate Pattern Recognition |
| Output Unit | Odor Units per cubic meter (OU/m³) |
| Data Transmission | Wi-Fi + Optional GSM/GPRS |
| Meteorological Integration | Integrated anemometer and wind vane |
| Operating Mode | Fully Automated, Unattended 24/7 Monitoring |
| Software Algorithms | PCA, PLS, Mahalanobis Distance, Euclidean Distance |
| Sensor Configuration | 10-channel MOS sensor array |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Pricing | Available Upon Request |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | AKS-P8018A |
| Pressure Range | 0–100 MPa |
| Adjustment Resolution | 0.1 kPa |
| Pressure Medium | P816C Hydraulic Oil |
| Pressure Port | Three M20×1.5 Female Quick-Connect Threads |
| Dimensions | 460 × 385 × 178 mm |
| Weight | 13.2 kg |
| Brand | EXPEC (Puyu Technology) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | ALG-300 |
| Pricing | Available Upon Request |
| Brand | AMAE |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AM-1026 |
| Pricing | Available Upon Request |
| Brand | AMAE |
|---|---|
| Origin | Jiangsu, China |
| Model | AM-1056 |
| Measurement Principle | Alternating Flow Modulated NDIR (Non-Dispersive Infrared) at 4.67 µm |
| Measurand | Carbon Monoxide (CO) in Ambient Air |
| Range | 0–10 / 25 / 50 ppm (field-expandable) |
| LOD | 0.2 ppm (2σ, ≤10 ppm range) or 0.5% F.S. (2σ, >10 ppm range) |
| Accuracy | ±1.0% F.S. |
| Linearity | ±1.0% F.S. |
| Zero Drift | ±0.5 ppm/day or ±1.0% F.S./day |
| Span Drift | ±1.0% F.S./day or ±3.0% F.S./week |
| Response Time (T90) | ≤80 s |
| Sample Flow Rate | ~1 L/min |
| Dimensions | 483 mm × 545 mm × 133 mm (L×W×H) |
| Power Consumption | 50 W |
| Connectivity | Embedded Web Server (Ethernet/Wi-Fi) |
| Calibration | Scheduled Auto-Calibration Support |
| Enclosure | Industrial Rack-Mountable Chassis (19″, 3U) |
| Brand | AMAE (Guoji Instruments) |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AM-3000 Series |
| Pricing | Available Upon Request |
| Brand | AMAE |
|---|---|
| Origin | Jiangsu, China |
| Model | AM-3100 |
| Detection Principle | Photoionization Detection (PID) with 10.6 eV UV Lamp |
| Measurement Range | 0–10,000 ppb (as isobutylene equivalent) |
| Detection Limit | ≤1 ppb (typical) |
| Response Time (T90) | <30 s |
| Operating Temperature | 0–45 °C |
| Humidity Range | 0–90% RH (non-condensing) |
| Data Storage Capacity | ≥3 years of continuous 1-minute interval data and system logs |
| Power Supply | 220 VAC ±10%, 50 Hz with integrated UPS backup |
| Communication Interfaces | RS485, RS232, Ethernet (Modbus TCP/RTU, HTTP API), optional 4G/LTE module |
| Enclosure Rating | IP54 |
| Dimensions | 482 × 360 × 177 mm (19″ rack-mountable) |
| Compliance | CE, RoHS, GB/T 3836.1–2010 (Explosion-Proof Optional) |
| Brand | AMAE (Guoji Instruments) |
|---|---|
| Origin | Jiangsu, China |
| Model | AM-3200 Series |
| Detection Methods | Dual-FID + Optional GC-MS |
| Target Compounds | 57 PAMS VOCs (Dual-FID), up to 117 VOCs including TO-15 compounds and carbonyls (GC-MS mode) |
| Expandable to Odorants | H₂S, CH₃SH, CH₃SCH₃, CH₃SSCH₃, CS₂ |
| Sample Introduction | Continuous, cryo-trap-assisted preconcentration |
| System Inertness | High-inertness valves, tubing, and switching manifolds |
| Software | AMAE proprietary intelligent chromatographic analysis platform with automated peak identification, calibration management, and audit-ready data logging |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | AM-IoT100 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | HCS-501 |
| Pricing | Available Upon Request |
| Brand | ANJIE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | AJ-600 |
| Pricing | Available Upon Request |
| Dispensing Volume Range | 50–1000 mL |
| Dispensing Accuracy | ≤ ±2% |
| Temperature Control Range | 4–60 °C |
| Temperature Stability | ±1 °C |
| Full-Volume Preparation Time | <15 min |
| Onboard Protocol Storage | ≥10 preloaded methods |
| Integrated Log System | Audit-trail-capable user activity logging |
| Touchscreen Interface | Color LCD with intuitive GUI |
| Built-in Functions | Automated stirring, temperature regulation, system self-cleaning, headspace liquid-path purging, method recall and execution |
| Brand | AP2E |
|---|---|
| Origin | France |
| Model | ProCeas® |
| Measurement Principle | Optical-Feedback Cavity-Enhanced Absorption Spectroscopy (OF-CEAS) |
| Detection Gases | CO₂, CH₄, N₂O, NH₃, H₂O |
| Sampling Rate | 2 Hz |
| Measurement Cavity Volume | 25 mL |
| Temperature Stability | ±0.002 K (1 s), ±5×10⁻⁵ K (30 min) |
| Pressure Stability | ±0.016 mbar |
| Accuracy (5 min avg) | <1 ppb (N₂O, CH₄, NH₃), <80 ppb (CO₂), <60 ppm (H₂O) |
| Drift (24 h) | <5 ppb (N₂O), <3 ppb (CH₄), <0.5 ppm (CO₂) |
| Response Time | <4 s |
| Operating Temperature | −10 to +45 °C |
| Relative Humidity | <99% RH (non-condensing) |
| Flow Rate | ~200 mL/min |
| Output Interfaces | Ethernet, Modbus TCP/IP & RS, Analog, USB |
| Power | 110–230 VAC, 50–60 Hz, 150 VA |
| Dimensions | 19″ rack mount, 4U |
| Weight | 20 kg |
| Brand | API |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | T700 |
| Pricing | Upon Request |
| Brand | API |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | T750 |
| Pricing | Upon Request |
| Brand | API |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | T750U |
| Pricing | Upon Request |
| Brand | Apogee |
|---|---|
| Origin | USA |
| Model | SM500 / SM600 |
| Temperature Range | –60 to +80 °C |
| Temp Accuracy | ±0.2 °C |
| Temp Drift | <0.02 °C/year |
| Temp Repeatability | <0.01 °C |
| Temp Response Time | 7 s |
| RH Range | 0–95 %RH |
| RH Accuracy | ±3 % @ 20–80 %RH |
| CO₂ Range | 0–2000 ppm |
| CO₂ Accuracy | ±50 ppm + 2 % of reading |
| CO₂ Response Time | 105 s |
| Barometric Pressure Range | 70–110 kPa |
| Spectral Range (SM500) | 389–692 nm |
| Spectral Range (SM600) | 383–757 nm |
| PAR/ePAR Range | 0–4000 µmol·m⁻²·s⁻¹ |
| Calibration Uncertainty | ±5 % |
| Long-term Instability | <2 %/year |
| Measurement Repeatability | <0.5 % |
| Field of View | 180° |
| Directional Response Error | ±5 % @ 75° zenith angle |
| Azimuthal Error | <0.5 % |
| Tilt Error | <0.5 % |
| Nonlinearity | <1 % |
| Sensor Response Time | 1 ms |
| Temp Coefficient | –0.11 % ±0.04 %/°C |
| Daily Integral Uncertainty | <5 % |
| Power Supply | 5–30 V DC |
| Power Consumption | 1.1–1.5 W |
| Data Storage | 9 months of 1-minute intervals |
| Output Interfaces | Modbus RTU (RS-232 & RS-485) and Bluetooth 5.0 |
| Operating Environment | –40 to +60 °C, 0–100 %RH |
| Enclosure Material | White ASA plastic |
| IP Rating | IP53 |
| Weight | 392 g |
| Dimensions | Ø105 mm × H157 mm |
| Cable Length | 5 m |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | O2S-F |
| Pricing | Available Upon Request |
| Diffusion-Type (D) | Height 1.375", Diameter 1.375", Mesh Size 125 |
| Flow-Through Type (F) | Length 3.5 cm, Diameter 3.5 cm, Tubing Port 1/8" NPT |
| Output (D/F) | ~50 mV at 20.95% O₂ (D), ~12 mV at 20.95% O₂ (F) |
| Lifetime | >10 years continuous (D), >5 years continuous (F) |
| Response Time (t₉₀) | 60 s (D), 12 s (F) |
| Measurement Range | 0–100% O₂ |
| Accuracy Drift | <0.01% O₂/day |
| Repeatability | ±0.001% O₂ (10 ppm) |
| Operating Temperature | 0–50 °C |
| Power Supply | 12 V for heater (TM variant), 5 V excitation for thermistor (TM) |
| Sensor Dimensions | Ø3.15 cm × 6.85 cm |
| Weight | 175 g |
| Standard Cable | 3 m (extendable) |
| Soil-Compatible Variant | O2S-S |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AquapHOx-LX |
| Pricing | Upon Request |
| Brand | DSE (Dongshen Electronics) |
|---|---|
| Model | AquaProfiler ST |
| Measurement Principle | Pulsed Doppler Acoustic Velocity Profiling |
| Operating Frequencies | 600 kHz or 2 MHz selectable |
| Measuring Range | River Width 0.25–120 m |
| Beam Configuration | Triple acoustic beam |
| Velocity Profiling Layers | Up to 64 depth cells |
| Integrated Parameters | Water Level, Velocity, Discharge, Water Temperature |
| Mounting Options | Horizontal or vertical fixed installation |
| Data Output | Real-time streaming, continuous logging, remote control via RS-485/Ethernet/4G |
| Compliance | Designed for ISO 748, ISO 10707, and ASTM D5389 field velocity profiling standards |
| Brand | ARALAB |
|---|---|
| Model | FitoClima 1000 ECV45 |
| Temperature Range | −45 °C to +180 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Uniformity | ±1 °C |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Range | 10–98% RH (at 10–90 °C) |
| Humidity Accuracy | ±0.1% RH |
| Humidity Fluctuation | ±1% RH |
| Humidity Uniformity | ±2% RH |
| Internal Volume | 1000 L |
| Vibration Mode | Horizontal Linear Motion & Vertical Elevating Motion |
| Control System | Integrated Programmable Environmental Controller |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Argonaut |
| Pricing | Available Upon Request |
| Weight (Air/Water) | 3.18 kg / 0.45 kg |
| Pressure Rating | 60 m submersion |
| 3D Probe Circumference | 130 mm |
| 2D Probe Circumference | 147 mm |
| Sampling Volume | 0.25 cm³ at 10 cm from transducer |
| Sampling Interval | User-configurable |
| Internal Memory | 4 MB (≥200,000 samples) |
| Velocity Range | ±0.001–6 m/s |
| Velocity Resolution | 0.0001 m/s |
| Velocity Accuracy | ±1% of measured value or ±0.001 m/s (whichever greater) |
| Temperature Sensor Resolution | 0.01 °C |
| Temperature Accuracy | ±0.1 °C |
| Operating Temperature | −5 °C to +40 °C |
| Storage Temperature | −10 °C to +50 °C |
| Power Input | 6–30 V DC |
| Power Consumption (continuous) | 0.2–0.5 W |
| Pressure Sensor Options | Strain-gauge (±0.1% FS) or Resonant Pressure Transducer (RPT, ±0.01% FS) |
| Communication Interfaces | RS-232 (standard), SDI-12, 4–20 mA, RS-422/RS-485 (optional) |
| Optional Sensors | Compass/inclinometer, Sea-Bird CTD, YSI multiparameter probes, SonWave wave spectral package, pressure-based water level sensor |
| Brand | Aria |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Models | AF101, AF111 |
| Wind Speed Range | 0.01–30 m/s |
| Temperature Range | −20–70 °C |
| Relative Humidity Range | 2–98 %RH |
| Wind Speed Resolution | 0.01 m/s (0.1 m/s above 10.0 m/s) |
| Accuracy | ±2 % or ±0.05 m/s (whichever is greater), ±0.5 °C, ±3 %RH |
| Operating Environment | −20–70 °C (non-condensing), 2–98 %RH |
| Response Time | 90 % in ≤1 s (wind speed 0–1 m/s), ≤60 s (RH, still air) |
| Power | 2 × AA alkaline batteries (approx. 20 h at 5 m/s, 20 °C) |
| Weight | 150 g (AF101), 175 g (AF111), incl. batteries |
| Communication | Bluetooth 4.0+, up to ~5 m line-of-sight |
| Probe | I/L dual-mode telescopic probe with mm scale markings |
| Mounting | 1/4″-20 tripod thread (also functions as hanging lug) |
| Brand | AZUP |
|---|---|
| Origin | Spain |
| Manufacturer | AZUP |
| Type | Imported |
| Model | Ariel |
| Frequency | 1.413 GHz (L-band) |
| Bandwidth | 20 MHz |
| Radiometric Accuracy | ±0.2 K |
| Temperature Resolution | 0.02 K |
| Sampling Rate | Up to 10 Hz |
| Polarization | Dual (H + V) |
| Beamwidth | 22° (aircraft-mounted) |
| Power Input | 12 V DC |
| Power Consumption | 0.5 A (electronics), 4 A (heating, aircraft mode) |
| GNSS | Integrated GPS/Glonass/BeiDou, WGS84 (EPSG:4326) |
| Data Interface | Ethernet |
| Onboard Storage | Internal |
| Dimensions (airborne) | 400 × 300 × 250 mm |
| Weight (airborne) | 15 kg |
| Platform Compatibility | Fixed-wing aircraft, UAVs, ground vehicles |
| Frequency Range | 20 Hz–8 kHz |
|---|---|
| Measurement Range | 30 dB–130 dB(A) |
| Exposure Range | 0–19.99 Pa²·h |
| Time Weighting | Fast (F), Slow (S) |
| Frequency Weighting | A-weighting |
| Measurement Durations | 10 s, 1 min, 5 min, 10 min, 15 min, 30 min, 1 h, 4 h, 8 h, 24 h |
| Microphone | Φ12.7 mm electret condenser sensor |
| Operating Voltage | 2.2–3.3 V DC |
| Battery | 2 × AAA, >24 h operation |
| Operating Temperature | −10 °C to +50 °C |
| Relative Humidity | 20–90 % RH |
| IP Rating | IP54 |
| Intrinsic Safety Certification | Exib I Mb |
| Dimensions | 116 × 61 × 25 mm |
| Weight | 160 g |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | ASR6 |
| Price Range | USD 280–700 |
| Frequency Range | 20 Hz–12.5 kHz |
| Measurement Range | 70–140 dB |
| Accuracy | ±1.5 dB |
| Measurement Durations | 10 s, 1 min, 5 min, 10 min, 15 min, 30 min, 1 h, 4 h, 8 h, 24 h |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ASV5910 |
| Pricing | Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | CM-800α Online Refractometer |
| Pricing | Available Upon Request |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-800α |
| Measurement Principle | LED-based Abbe Refractometry (D-line equivalent) |
| Measured Parameter | Brix (% w/w, ATC) & Temperature (°C/°F) |
| Accuracy | ±0.1% Brix, ±1°C/°F |
| Range | 0.00–80.00% Brix (ATC), −15–160.0°C |
| ATC Range | 5–100°C |
| Resolution | 0.01% or 0.1% Brix (user-selectable), 1°C/°F |
| Output | DC 4–20 mA, RS-232C (refractive index or Brix data selectable via host interface) |
| Sampling Interval | ~1 s (default) |
| IP Rating | IP67 |
| Light Source | High-stability LED (D-line equivalent, 589 nm) |
| Prism Material | Synthetic Sapphire |
| Body Material | SUS316L Stainless Steel |
| Dimensions | 160 × 167 × 110 mm |
| Weight | 2.4 kg |
| Power Supply | DC 24 V (AC 100 V optional with AD-32 adapter) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | PRM-100α DX |
| Measurement Range | nD 1.32000–1.55700 |
| Accuracy | ±0.00010 (nD), ±0.05% (Brix) |
| Temperature Range | −5.0–160.0 °C |
| Auto-Temperature Compensation | 5–100 °C |
| Output | 4–20 mA, RS-232C |
| IP Rating | IP67 |
| Pressure Rating | 0.98 MPa |
| Sample Cell Material | SUS316L |
| Prism Material | Synthetic Sapphire |
| Display | 7-segment LED |
| Power | AC 100–240 V, 50–60 Hz |
| Cable Length | Standard 15 m (extendable to 200 m) |