| Brand | Beifen Sanpu |
|---|---|
| Model | 76-1A |
| Power Supply | 220 V ±10 V, 50 Hz |
| Heating Power | 1000 W |
| Stirring Motor Power | 60 W |
| Temperature Control Accuracy | ±0.5 °C |
| Temperature Range | Ambient to 100 °C |
| Stirring Speed Range | 0–2000 rpm (infinitely variable) |
| Chamber Dimensions | Ø300 × 300 mm |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic (China) |
| Model | FD220 |
| Price | USD 9,400 (FOB Beijing) |
| Sensitivity (Radon) | ≥110 cpm/Bq |
| Sensitivity (Thoron) | ≥22 cpm/Bq |
| Background Count Rate | ≤2.5 cpm |
| Counting Capacity | 1–2³² pulses |
| Repeatability (RSD) | ≤2.7% (using ²⁴¹Am source, 8000 particles/2π·min) |
| Accuracy (Radon) | ±5% MPE at ≥37 Bq/g |
| Accuracy (Thoron) | ±8% MPE at ≥40.58 Bq/g |
| Detection Limit (Radon) | 0.01 Bq (5 min) |
| (Thoron) | 0.05 Bq (5 min) |
| Stability (RE) | ≤2.7% over 8 h |
| Operating Modes | Radon — single-point or continuous |
| Power Supply | 12 V DC / optional Li-ion rechargeable battery (≥48 h runtime) |
| Operating Temperature | –10 to +50 °C |
| Relative Humidity | ≤90% at +40 °C |
| Dimensions (W×D×H) | 310 × 250 × 213 mm |
| Weight | 11.0 kg |
| Certification | Verified and calibrated by National Institute of Metrology, P.R. China (NIM) |
| Brand | Beifen Sanpu |
|---|---|
| Model | FD901 |
| Chamber Effective Volume | 0.06 m³ |
| Temperature Control Range | +20–+30 °C |
| Temperature Accuracy | ±0.5 °C |
| Humidity Control Range | 30–60 %RH |
| Humidity Accuracy | ±5 %RH |
| Chamber Material | 304 Stainless Steel |
| Interface | USB |
| Power Supply | ~220 V / 50 Hz, ~800 W |
| Display | 5″ TFT Capacitive Touch LCD |
| Operating Ambient | +5–+40 °C, ≤95 %RH at +40 °C |
| Dimensions (W×D×H) | 850×420×740 mm |
| Weight | ~60 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | HD-2000 |
| Price | USD 2,250 (approx.) |
| Compliance | GB/T 4835.1–2012 |
| Metrological Approval Certificate | PA No. 2011A182-11 |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | HD-2000 |
| Measurement Principle | Scintillation-based gamma spectrometry with NaI(Tl) detector |
| Energy Threshold | 40 keV |
| Measurement Ranges | Equivalent Uranium (1–30,000 Ur), Exposure Rate (0.30–5,000 nC·kg⁻¹·h⁻¹), Air Kerma Rate (0.01–300 µGy·h⁻¹) |
| Sensitivity | ≥5 s⁻¹/Ur (Uranium), ≥30 s⁻¹/nC·kg⁻¹·h⁻¹ (Exposure) |
| Stability | ≤5% relative error over 8 h |
| Nonlinearity | ≤10% |
| Accuracy | ±5% for gamma measurement |
| GPS positional accuracy | ≤5 m |
| Power Supply | 4 × Ni-MH rechargeable batteries |
| Power Consumption | ≤700 mW (standalone), ≤900 mW (with GPS active) |
| Operating Temperature | −5 to +50 °C |
| Relative Humidity | ≤95% at +40 °C |
| Alarm Threshold | Numerically adjustable |
| Integration Time | 3–9,999 s selectable |
| Data Storage | 120,000 measurement records |
| Dimensions (Long) | 673 × 51 × 230 mm, 1.4 kg |
| Dimensions (Short) | 371 × 51 × 230 mm, 1.2 kg |
| Certification | Verified by Radioactive Exploration Measurement Station of Nuclear Industry |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | YDN100 |
| Display | 5-inch Color LCD with Chinese UI & Touchscreen Control |
| Kinematic Viscosity Range | 0.5–20,000 mm²/s |
| Dynamic Viscosity Range | 0.3–40,000 mPa·s |
| Temperature Control Range | Ambient to 150 °C |
| Temperature Accuracy | ±0.03 °C |
| Temperature Sensing Resolution | 0.01 °C |
| Timing Accuracy | ±0.1 s |
| Bath Volume | 10 L |
| Heating Power | 1000 W |
| Stirring Speed | 1300 rpm |
| Test Stations | 4 |
| Data Storage | 256 test records (non-volatile memory) |
| Power Supply | 220 V ±10%, 50 Hz |
| Dimensions | 440 × 320 × 450 mm |
| Compliance | GB/T 265, SY/T 5651, GB 1660, GB 1841, ASTM D445, GB/T 11137, SH/T 0173, JJG 155] |
| Brand | Belfort (USA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Model 6000 |
| Price | USD 9,200 (FOB US Port) |
| Discontinued — Replacement Model | Model 6400 |
| Measurement Principle | Forward Scatter (42° scattering angle) |
| Range | 6 m to 80 km |
| Accuracy | ±10% or ±3 m (whichever greater) |
| Light Source | High-output infrared LED |
| Analog Outputs | 0–1 V, 0–5 V, 0–10 V, 4–20 mA |
| Alarm Outputs | 2-channel TTL (user-configurable thresholds) |
| Digital Interface | RS-232 / RS-422, 300–38,400 baud |
| Operating Temperature | −40 °C to +55 °C |
| Relative Humidity | 0–100 % RH |
| Power Supply | 110 VAC / 220–240 VAC / 12 VDC |
| Power Consumption | 12 W (standard), 17 W (with Ambient Light Sensor), 25 W (with heated shroud) |
| Dimensions | 978 mm × 343 mm × 425 mm |
| Weight | 8.75 kg |
| Mounting | U-bolt bracket |
| Max Wind Speed Tolerance | 60 m/s |
| Housing Material | Corrosion-resistant aluminum alloy |
| Lens Heater | Standard |
| Optional Heated Shroud | Available (Part No. 96916-01) |
| Calibration Kit | Optional (Part No. 90001) |
| Compliance | CE Marked |
| FCC Compliance | 47 CFR Part 15 |
| Environmental Certification | IP65 equivalent |
| Brand | Belfort (USA) |
|---|---|
| Origin | USA |
| Model | Model 6400 |
| Measurement Range | 6 m to 80 km |
| Accuracy | ±10% MOR |
| Scattering Angle | 42° |
| Light Source | High-output infrared LED |
| Output | RS232 (300–38,400 bps), SPDT relay |
| Operating Temperature | −40 °C to +55 °C |
| Relative Humidity | 0–100% RH |
| Power | 6 W (standby), 30 W (heater active) |
| Supply Voltage | 12 VDC @ 500 mA |
| Dimensions | 97 × 33 × 41 cm |
| Weight | 7.9 kg |
| Ingress Protection | IP66 |
| Lens Heater | Integrated |
| Optional | Calibration Kit (P/N 93001), Shroud Heater, Analog Output |
| Brand | Belfort (USA) |
|---|---|
| Origin | USA |
| Model | 6450 |
| Measurement Range | 6 m to 80 km |
| Accuracy | ±10% |
| Scattering Angle | 42° |
| Light Source | High-output Infrared LED |
| Output | RS232 (300–38,400 baud), SPDT Relay |
| Operating Temperature | −40 °C to +60 °C |
| Relative Humidity | 0–100% RH |
| Power Consumption | 12 W (sensor), 25 W (shroud heater) |
| Dimensions | 97 × 33 × 41 cm |
| Weight | 7.9 kg |
| Weather Phenomena Recognition | 15 WMO codes including rain (R, −R, R+), snow (S, −S, S+), freezing rain (FZRA), ice pellets (PL), fog (FG), mist (BR), haze (HZ), smoke (FU), sand (SA), and clear sky (NSW) |
| Precipitation Rate Measurement | 0.25–20.3 mm/h (±<5% error) |
| Lens Heater | Standard |
| Shroud Heater | Optional |
| Calibration Kit P/N | 92001 |
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | BET |
| Pricing | Upon Request |
| Heating Temperature | 70 °C |
| Internal Volume | 40 mL |
| Response Time | < 100 ms |
| Sample Line Length | 2 m |
| Clinical Compliance | ISO/IEC 60601-1 |
| Brand | BF-Agritech |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | PM-11 |
| Input Channels | 8 × 11-bit analog + dedicated digital RTH interface |
| Sampling Rate | Configurable from 1 s to 1 h |
| Memory | 512 KB non-volatile |
| Power Supply | 12 V DC (AC adapter 90–260 V AC / rechargeable battery / solar kit optional) |
| Communication | RS-232 (1 m), RS-485 (up to 1.2 km), or wireless modem (0.3–64 km range) |
| Enclosure | IP65-rated weatherproof housing |
| Dimensions | 18 W × 14 H × 11.5 L cm |
| Operating Temperature | 0–50 °C |
| Humidity Range | 0–100 % RH |
| Compatible Sensors | RTH (air T/RH/PAR/leaf wetness), SD-5M (stem diameter change, 0–5000 µm), SD-6M (trunk diameter change, 0–5000 µm), DE-1 (dendrometer, 0–10 mm), FI-LM/FI-MM/FI-SM (fruit expansion, 7–160 mm), LT-2M (leaf temperature, 5–50 °C), SF-4M/SF-5M (sap flow, up to ~3 mL/h), SA-20 (growth gauge, 0–2000 mm, ~2 mm resolution), TIR-4 (global solar radiation, 0–1000 W/m², 300–1100 nm), PAR-2 (photosynthetically active radiation, 0–2500 µmol/m²·s, 400–700 nm), ATH-2 (air T/RH), ST-21 (soil temperature, 0–50 °C) |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | MD Series Microwave Digestion System |
| Pricing | Upon Request |
| Cavity Volume | 56 L |
| Microwave Frequency | 2450 MHz |
| Output Power | 0–1600 W (non-pulsed, continuous, dual-magnetron) |
| Max. Operating Pressure | 15 MPa (2200 psi) |
| Max. Operating Temperature | 300 °C |
| Digestion Vessel Capacity | 56 mL |
| Vessel Material | TFM inner vessel, PEEK outer vessel |
| Temperature Measurement | Non-contact mid-infrared, 0–300 °C, ±1 °C accuracy |
| Temperature Control Stability | ±1 °C |
| Turntable Speed | 10 rpm, 360° rotation |
| Ventilation Rate | 5 m³/min (corrosion-resistant centrifugal blower) |
| Display | 7-inch color touchscreen controller |
| Dimensions (W×D×H) | 520 × 640 × 590 mm |
| Weight | 61 kg |
| Cavity Construction | 304 stainless steel, seamless welding, 6-layer PFA coating |
| Safety | Multi-layer explosion-proof door with microwave shielding and auto-locking mechanism |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Available Apertures | 0.15 mm (100 mesh), 0.25 mm (60 mesh), 0.5 mm (35 mesh), 1.0 mm (18 mesh), 2.0 mm (10 mesh), 4.0 mm (5 mesh), 5.0 mm, 9.5 mm, 10.0 mm, 22.4 mm |
| Diameter | 200 mm |
| Material | Stainless steel frame with PTFE-coated woven wire mesh |
| Compliance | Designed to meet HJ/T 557–2007 specifications for solid waste particle size analysis |
| Brand | BJBY |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BY-CEM |
| Pricing | Available Upon Request |
| Particle Detection | PM2.5 (0–10,000 µg/m³, ±10% accuracy, 1 µg/m³ resolution) |
| Display | 7-inch capacitive touchscreen |
| Power | AC adapter + internal rechargeable battery |
| Connectivity | 4G LTE, Wi-Fi, USB, RS485, external antenna port |
| Enclosure | Ruggedized portable housing with tripod mount and wall-mount bracket |
| Data Storage | Local buffered storage + cloud-synchronized time-series database |
| Compliance | Designed for alignment with ISO 16000-23 (indoor air quality — sensor performance evaluation), GB/T 18883-2022 (China Indoor Air Quality Standard), and WHO Air Quality Guidelines (2021) |
| Brand | BJBY |
|---|---|
| Origin | China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Hot-Wire Anemometer |
| Measurement Range | 0.00–25 m/s |
| Resolution | 0.01 m/s |
| Accuracy | ±(2% of reading + 0.1 m/s) |
| Operating Temperature | 0°C to 60°C |
| Sensor Type | Constant-Temperature Anemometry (CTA) Thermal Probe |
| Power Supply | 9 V alkaline battery or 220 V AC/DC adapter |
| Battery Life | >100 hours (on 9 V battery) |
| Display | Backlit LCD, simultaneous wind speed and temperature readout |
| Weight | <1.5 kg (including carrying case) |
| Compliance | Certified by National Institute of Metrology (NIM), P.R. China (CNAS-accredited calibration traceable to SI units) |
| Brand | BJBY |
|---|---|
| Model | DYM3 |
| Type | Aneroid Barometer |
| Measurement Range | 800–1064 hPa |
| Accuracy (after temperature, scale, and supplemental corrections) | ≤ ±2.0 hPa |
| Scale Division | 1 hPa |
| Thermometer Division | 1 °C |
| Operating Temperature | −10 to +40 °C |
| Dimensions | 156 × 156 × 115 mm |
| Weight | ≤ 1.5 kg |
| Origin | Tianjin, China |
| Compliance | Designed per GB/T 12159–2015 (Chinese National Standard for Aneroid Barometers) |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | Brewer MkIII Spectrophotometer |
| Measurement Principle | Double-monochromator UV spectrophotometry with PMT detection |
| Wavelength Range | 286.5–363 nm |
| Spectral Resolution | 0.6 nm |
| Wavelength Stability | ±0.01 nm over full operating temperature range |
| Power Supply | 230 VAC or 115 VAC / Optional DC input |
| Operating Temperature | −20 °C to +50 °C (−50 °C to +50 °C with optional cold-weather enclosure) |
| Measured Parameters | Total Ozone Column (TOC), SO₂ Column, Spectral UV Irradiance (286.5–363 nm), UVA (315–400 nm), UVB (280–315 nm), UVE (250–260 nm), UV Index (UVI) |
| Compliance | Designed to meet WMO/GAW reference instrument requirements for ground-based UV and ozone monitoring |
| Sample Compatibility | Direct solar irradiance (direct sun, zenith sky, and diffuse sky modes) |
| Software Interface | PC-based control with 24/7 autonomous operation capability, remote telemetry support |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | EM27/SUN |
| Spectral Range (NIR) | 5000–14500 cm⁻¹ |
| Spectral Range (MIR) | 750–5200 cm⁻¹ |
| Spectral Resolution (MIR, optional) | 0.2 cm⁻¹ (standard: 0.5 cm⁻¹) |
| Application | Ground-based solar absorption spectroscopy for atmospheric trace gas monitoring |
| Compliance | Designed for field-deployable, long-term unattended operation in remote environments |
| Software Interface | Integrated CAMTracker solar tracking control with real-time alignment feedback |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HI 90 |
| Pricing | Available Upon Request |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SIGIS II |
| Pricing | Upon Request |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | BSQ-20 |
| Power Supply | AC 220 V |
| Sample Vial Capacity | 12 mL |
| Vial Tray Configuration | 14 × 14 (196 positions) |
| Positioning Accuracy | ±0.01 mm |
| Controller Display | Blue TFT LCD |
| Dimensions (W × D × H) | 490 mm × 482 mm × 330 mm |
| Frame Material | Anodized Aluminum Alloy |
| Motion Control | Digital Stepper Motor with Microstepping Driver |
| Automation Level | Fully Unattended Operation |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AP200 |
| Pricing | Upon Request |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CPEC200 |
| Operating Temperature | −30 °C to +50 °C |
| Input Voltage | 10.5–16.0 Vdc |
| Typical Power Consumption | 12 W (max 35 W cold start) |
| System Dimensions | 52.1 × 44.5 × 29.7 cm |
| System Weight | 11.6 kg |
| Pump Module Flow Rate | 3–9 LPM (typ. 7 LPM) |
| Pump Pressure Range | 15–115 kPa |
| Valve Modules | 3-valve (zero, CO₂ span, H₂O span) or 6-valve (zero, four CO₂ spans, one H₂O span) |
| Data Storage | 2 GB CompactFlash card (≥60 days at 10 Hz) |
| Communication Interfaces | Ethernet, RS-232, short-haul modem, cellular, radio, satellite |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CPEC310 |
| Operating Temperature Range | −30 °C to +50 °C |
| Input Voltage | 10.5–16.0 V DC |
| Typical Power Consumption | 12 W |
| Max Power (Cold Start) | 35 W |
| Sample Cell Volume | 5.9 mL |
| Sample Residence Time | 50 ms @ 7 L/min |
| Frequency Response (−3 dB) | 5.8 Hz (CO₂/H₂O) |
| Cut-off Frequency (System) | 4.3 Hz |
| Pump Flow Rate | 3–9 L/min (Auto-Controlled, Default: 7 L/min) |
| Pressure Sensor Range | 15–115 kPa |
| Enclosure Dimensions (Control Box) | 54 × 44.5 × 29.7 cm |
| Weight (Control Box) | 15.36 kg (16.24 kg w/ CDM-A116) |
| Pump Module Dimensions | 35.6 × 29.2 × 13.5 cm |
| Weight (Pump Module) | 5.4 kg |
| Three-Valve Module Dimensions | 14.0 × 12.7 × 14.0 cm |
| Weight | 1.5 kg |
| Scrubber Module Heater Power | 8 W |
| Molecular Sieve Bead Size | 1.6–2.5 mm |
| Scrubber Cylinder Volume | 480 cm³ |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CS320 |
| Sensor Type | Thermopile-based Total Solar Radiation Sensor |
| Calibration Uncertainty | ±5% |
| Measurement Range | 0–2000 W/m² |
| Repeatability | <1% |
| Long-term Drift | <2% per year |
| Non-linearity | <1% |
| Spectral Range | 385–2105 nm |
| Field of View | 180° (hemispherical) |
| Response Time | 2 s |
| Temperature Dependence | <5% over −15 to +45 °C |
| Operating Temperature | −50 to +50 °C |
| Heating Power | 0.2 W |
| Supply Voltage | 6–24 VDC |
| Current Consumption | 5 mA (during measurement) |
| Output Protocol | SDI-12 digital interface |
| Sensor Diameter | 34.3 mm |
| Height | 39.6 mm |
| Mass | 64.9 g |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CSAT3 |
| Measurement Principle | Ultrasonic Time-of-Flight (TOF) in Three Orthogonal Axes |
| Vertical Path Length | 10 cm |
| Output Frequency | Up to 50 Hz |
| Output Options | Analog (±5 V) and Digital (SDM, RS-232) |
| Operating Temperature Range | –30°C to +50°C |
| Ingress Protection | IP66-rated enclosure |
| Compliance | Designed for eddy covariance systems compliant with AmeriFlux, ICOS, and FLUXNET protocols |
| Integrated Clock | Internal temperature-compensated crystal oscillator (TCXO), ±1 ppm stability over operating range |
| Synchronization | SDM-compatible for precise multi-sensor timing alignment |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | IRGASON |
| Measurement Principle | Simultaneous open-path infrared absorption (CO₂/H₂O) and ultrasonic anemometry (3D wind velocity, sonic temperature) |
| Output Frequency | Up to 60 Hz |
| Bandwidth | 20 Hz |
| Power Consumption | Low-power design compatible with solar power systems |
| Environmental Rating | IP65-rated enclosure |
| Calibration | Factory-calibrated for CO₂, H₂O, air temperature, barometric pressure, and sonic temperature across wide operational ranges |
| Diagnostic Capabilities | Comprehensive real-time diagnostics including signal strength, window contamination status, transducer health, and acoustic path integrity |
| Data Compatibility | Native support for Campbell Scientific CR series dataloggers (e.g., CR6, CR1000X) with full integration of setup, zero/span adjustment, and configuration via direct serial or SDI-12 interface |
| Rain Mitigation | Patented hydrophobic mesh + adaptive ultrasonic signal processing to maintain wind vector accuracy during precipitation |
| Optical Design | Angled optical windows with anti-water-adhesion geometry and tolerance for mild surface contamination |
| Thermal Management | Passive temperature compensation—no active heater required |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | SoilVUE10 |
| Measurement Principle | Time-Domain Reflectometry (TDR) |
| Output Protocol | SDI-12 v1.4 |
| Depth Options | 0.5 m (6 depth layers) or 1.0 m (9 depth layers) |
| Diameter | 5.2 cm (body), 5.8 cm (with threads) |
| Length | 0.55 m (0.5 m version) / 1.05 m (1.0 m version) |
| Weight | 1.9 kg / 3.6 kg |
| Operating Temperature | −30 °C to +40 °C |
| Volumetric Water Content Accuracy | ±1.5% (for most mineral soils) |
| Electrical Conductivity Range | 0–10 dS/m |
| Relative Permittivity Range | 1–80 |
| Relative Permittivity Accuracy | ±1 unit |
| Temperature Accuracy | ±0.15 °C |
| Power | ~64 mA dynamic / ~2.5 mA quiescent @ 12 VDC |
| IP Rating | IP67 (M12 connector) |
| Compliance | SDI-12 v1.4, RoHS, CE |
| Brand | Camsco |
|---|---|
| Dimensions | 6 mm OD × 4.5 in length |
| Sorbent | Tenax TA / Carboxen 1000 (dual-bed) |
| Conditioning | Pre-aged (baked out) |
| Cap | Stainless steel storage cap |
| Packaging | Individual sterile packaging |
| Compatibility | CDS thermal desorbers |
| Origin | Manufactured in USA, distributed by Sanpu (Beijing) |
| Brand | Casella |
|---|---|
| Origin | United Kingdom |
| Model | CEL-240 |
| Compliance | IEC 61672-1:2013 Class 2, ANSI S1.4-2014 Type 2 |
| Measurement Range | 30–130 dB(A), 35–130 dB(C) |
| Frequency Weighting | A, C, Z (Linear) |
| Time Weighting | Fast (F), Slow (S), Impulse (I) |
| Max Hold Function | Yes |
| Battery Life | >35 hours (alkaline) |
| Data Output | USB 2.0 (real-time & stored data) |
| Display | High-resolution backlit LCD with time-history trace |
| Operating Temperature | −10 °C to +50 °C |
| IP Rating | IP54 |
| Warranty | 2 years |