| Brand | TH-analyzer |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Manufacture | Domestic (China) |
| Model | THA100R |
| Measurement Principle | Thermal Conductivity Detection |
| Measuring Range | H₂ 0–100% vol |
| Standard H₂ Ranges | 0–1%, 0–10%, 35–75%, 40–80%, 75–100%, 98–100% |
| Operating Ambient Temperature | 5–45 °C |
| Stability | ±2% FS / 7 days |
| Repeatability | ±1% FS |
| Linearity Deviation | ±2% FS |
| Response Time (T₉₀) | ≤30 s |
| Output | Isolated 4–20 mA current loop |
| Digital Outputs | 8 relay (switching) outputs |
| Display | Color LCD with touch interface |
| Enclosure | 483 mm (19″) rack-mount chassis |
| Certification | Non-explosion-proof (not for hazardous areas) |
| Pressure Compensation | Built-in atmospheric pressure compensation |
| Temperature Control | Precision thermostatic regulation of sensor block |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Thermo Fisher 8000 Series Online Gas Chromatograph |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | alpha-DO2000 |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | CFNN11 |
| Pricing | Available upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | LevelPRO Series |
| Product Type | Nuclear Level Gauge |
| Radiation Source | Cs-137 or Co-60 |
| Source Activity Range | 1–10,000 mCi (Cs-137) / 1,000–3,000 mCi (Co-60) |
| Beam Angles | 30°, 45°, 60° |
| Measurement Accuracy | ±0.5% of span |
| Long-Term Stability | ±0.05% drift over 6 months (radiation-induced) |
| Temperature Drift | ±0.009% per °C |
| Response Time | 1–65,535 s |
| Detector Length | 1–12 ft (PVT scintillator, modular) |
| Operating Temperature | −40 °C to +75 °C |
| Enclosure Rating | NEMA 4X / IP65 |
| Power Supply | 115/230 VAC ±10%, 50/60 Hz or 24 VDC |
| Communication Interfaces | RS232, RS485, HART-certified, 10/100 M Ethernet, USB |
| Analog I/O | 4× 4–20 mA inputs, 2× 4–20 mA outputs, 2× 0–10 VDC inputs, 2× digital inputs/outputs, Pt100 RTD input |
| Safety Compliance | Meets IEC 60068-2-6 (sinusoidal vibration), IEC 60068-2-64 (random vibration), IEC 60068-2-27 (shock), IEC 60068-2-38 (temp/humidity cycling) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Level Meter |
| Model | Nitus |
| Compliance | Designed for industrial process environments requiring non-intrusive, radiation-based measurement |
| Radiation Source | Low-activity gamma emitter (e.g., Am-241 or Cs-137, configured per regional regulatory approval) |
| Installation | Single-side mounting (source and detector co-located) |
| Maximum Cable Length | 50 ft (15.2 m) between detector and secondary instrument |
| Operating Temperature Range | –20 °C to +60 °C (–4 °F to +140 °F) |
| Measurement Principle | Gamma backscatter spectroscopy |
| Regulatory Alignment | Compliant with ANSI N43.3, IEC 61000-6-2/6-4, and applicable national radiation safety codes (e.g., NRC 10 CFR 34, UK IR(ME)R) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | CFAN10 |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | CFSS12 |
| Pricing | Upon Request |
| Brand | PROCESS INSTRUMENTS |
|---|---|
| Origin | USA |
| Model | CG1000 |
| Type | Portable Oxygen Analyzer |
| Application | Industrial Process Control & Online Monitoring |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Tianyan Instrument Co., Ltd. |
| Model | TY-NIR-HT |
| Temperature Range | 0–500 °C |
| Moisture Range | 0–100 wt% |
| Moisture Accuracy | ±0.2 wt% (under stable composition conditions) |
| Temperature Accuracy | ±1% FS or ±1.5 °C |
| Optical Spot Diameter | 60–75 mm |
| Measurement Height Adjustment Range | 350 mm ± 100 mm |
| Filter Cycle | 1–60 s |
| Number of Calibration Channels | 50 |
| Optical Window | High-borosilicate quartz glass |
| Power Supply | 220 VAC / 50 Hz |
| Power Consumption | 60 W |
| Ingress Protection | IP65 |
| Curve Fitting | Supports >10 auto-calibration points per moisture calibration curve |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Model | TY-NIR-HT |
| Measurement Principle | Near-Infrared Reflectance Spectroscopy (NIRS) |
| Moisture Range | 0–100% w/w |
| Moisture Accuracy | ±0.2% (dependent on material composition stability) |
| Temperature Monitoring | Integrated infrared port, range 0–500 °C, accuracy ±1% FS or ±1.5 °C |
| Optical Spot Diameter | 60–75 mm |
| Installation Height Range | 350 mm ± 100 mm |
| Sampling Channels | 50 |
| Light Source | Imported high-efficiency NIR source |
| Filter Cycle | 1–60 s adjustable |
| Optical Window | High-borosilicate quartz glass |
| Power Supply | 220 VAC, 50 Hz |
| Power Consumption | 60 W |
| Enclosure Rating | IP65 |
| Calibration Support | Auto-calibration with ≥10 user-defined moisture calibration points |
| Operating Environment | High-temperature industrial settings |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Tianyan Instrument Co., Ltd. |
| Model | TY-NIR-T |
| Measurement Principle | Near-Infrared Reflectance Spectroscopy (NIRS) |
| Measurement Range | 0–100% w/w (water content by weight) |
| Accuracy | ±0.2% w/w (dependent on material homogeneity and spectral stability) |
| Light Source | Imported high-stability NIR LED array |
| Optical Spot Diameter | 60–75 mm |
| Working Distance | 350 mm ± 100 mm |
| Spectral Channels | 50 discrete wavelength bands |
| Filter Integration Time | 1–60 s adjustable |
| Probe Window Material | High-borosilicate quartz glass |
| Operating Temperature | −40 °C to +70 °C |
| Relative Humidity | 5–95% RH (non-condensing) |
| Enclosure Rating | IP65 |
| Power Supply | 220 VAC, 50 Hz |
| Output Interfaces | RS485, 4–20 mA analog, RS232, Ethernet (LAN), LoRa wireless |
| Display | Integrated industrial-grade capacitive touchscreen |
| Probe Housing | Anodized aluminum alloy (ASTM B557-19 compliant) |
| Signal Processing | Full digital signal chain with adaptive noise filtering and baseline correction |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TMA-202 |
| Pricing | Upon Request |
| Brand | Truelab |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | A-1H, A-2H |
| Inlet Pressure Rating | 15 MPa |
| Adjustable Outlet Pressure Range | 0.12–0.99 MPa |
| High-Pressure Gauge Range | 0–25 MPa |
| Low-Pressure Gauge Range | 0–0.16 / 0–0.6 / 0–1.0 / 0–1.6 MPa |
| Inlet Connection | G5/8 (Right), W21.8-14 (Right or Left) |
| Outlet Connection | 8 mm Flexible Tube Fitting with Threaded Port |
| Regulatory Compliance | Designed per GB/T 25127.2–2010 and ISO 8503-2 for industrial gas handling systems |
| Key | Brand: Truelab |
|---|---|
| Origin | Beijing, China |
| Model Series | A-1H / A-2H / Ba-1H / Ba-2H / Sa-1H / Sa-2H |
| Inlet Pressure Range | 0–15 MPa |
| Outlet Pressure Range | 0–0.12 / 0.4 / 0.6 / 0.99 MPa |
| High-Pressure Gauge Range | 0–25 MPa |
| Low-Pressure Gauge Range | 0–0.16 / 0.6 / 1 / 1.6 MPa |
| Inlet Connection | G5/8 (RH), W21.8-14 (RH or LH) |
| Outlet Connection | 8 mm soft tubing with threaded ferrule |
| Material | Brass body with stainless steel diaphragm and internal components (A-series) |
| Dead Volume | < 1.2 mL |
| Operating Temperature | –10 °C to +50 °C |
| Compliance | Designed per ISO 8503-2 (surface profile), compatible with ASTM E2653 (gas purity verification protocols), suitable for GLP/GMP environments requiring traceable gas delivery |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 1,700 (FOB) |
| Compliance | GB/T 4857.3–1992, GB/T 4857.4–1992 |
| Load Capacity | Up to 5,000 N (configurable) |
| Displacement Resolution | 0.01 mm |
| Test Speed Range | 1–500 mm/min (adjustable) |
| Data Storage | 20 test records |
| Output | Thermal printer interface, USB data export |
| Brand | FPI (Focus Photonics) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-made) |
| Model | UTS-2000 |
| Pricing | Upon Request |
| Brand | Vaisala |
|---|---|
| Origin | Finland |
| Manufacturer | Vaisala Oyj |
| Type | Optimus™ OPT100 DGA |
| Application | Online dissolved gas analysis (DGA) for sealed power transformers |
| Measurement Principle | Non-dispersive infrared (NDIR) spectroscopy with vacuum-assisted headspace gas extraction |
| Calibration | Automatic in-situ zero/span correction using internal reference gas cell |
| Materials in contact with oil | 316 stainless steel and anodized aluminum |
| Pumping system | Magnet-driven gear pump |
| Maintenance interval | Maintenance-free design (no consumables, no scheduled servicing) |
| Installation time | <2 hours |
| Data output interval | Configurable down to 1-hour intervals (no data averaging required) |
| User interface | Web-based HTML5 interface with TLS-secured remote access |
| Environmental rating | IP65 enclosure |
| Compliance | Designed for IEC 60599, IEEE C57.104, and compatible with ISO/IEC 17025-accredited DGA workflows |
| Brand | VC Plasma |
|---|---|
| Model | JBT460 |
| Track Length | 850 mm |
| PCB Size Range | 30–460 mm |
| Conveyor Height | 900 ± 20 mm |
| Transmission Direction | Left-to-Right or Right-to-Left |
| Power Supply | 220 V / 50 Hz |
| Control System | Single-Chip Microcomputer |
| Conveyor Type | Flat Belt |
| Communication Interface | Dual SMEMA (Standardized Machine Equipment Manufacturer’s Association) |
| Dimensions (L×W×H) | 850 × 820 × 1100 mm |
| Brand | VC Plasma |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Dry Ice Capacity Options | 20 kg / 40 kg / 60 kg / 100 kg |
| Core Insulation Materials | Vacuum Insulation Panels (VIPs, 280–330 kg/m³) + Hollow Density Board (90 kg/m³) + Polyurethane (PU) Foam (55–60 kg/m³) |
| Thermal Conductivity (λ) | <0.0025 W/m·K |
| Average Daily Dry Ice Sublimation Rate | ≤5% |
| Brand | VC Plasma |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Application | Plasma Process Simulation & Industrial Plasma Source Driving |
| Key Features | Simple Operation, High Cost Performance, Low-Temperature Anti-Static Design, Compatible with Pointed and Rotating Transmitters |
| Brand | VC Plasma |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Power Architecture | DPM-Based Digital Platform |
| Input Power Factor Correction (PFC) | Integrated |
| Output Topology | High-Efficiency Full-Bridge Inverter |
| Output Waveform | Quasi-Sinusoidal |
| Control Method | Vector-Controlled Constant-Power Delivery |
| Frequency Management | Digital Variable-Frequency & Dynamic Frequency-Hopping |
| Human-Machine Interface | Touchscreen with Real-Time Parameter Visualization |
| Operating Temperature Range | 50–70 °C (customizable) |
| Output Potential | <23 V (customizable) |
| Energy Intensity Monitoring | Integrated Spectroscopic Detection |
| Emitter Compatibility | Direct-Injection & Rotary Plasma Emitters |
| Fault Diagnostics | 21-Channel Real-Time Fault Logging & Alarm System |
| Monitoring Capabilities | Dual-Loop Real-Time Supervision of Power Supply (voltage, current, power, air pressure, operating frequency, spray gun RPM, module temperature, fan status, communication integrity) and Motor Subsystem (voltage, current, power, torque, operational mode, health index, communication return rate, speed profile) |
| Brand | VC Plasma |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | NA |
| Pricing | Available Upon Request |
| Brand | Vcam |
|---|---|
| Model | GA2000 CH1-14 |
| Origin | Guangdong, China |
| Channel Capacity | 2–14 configurable analog input channels |
| Measurement Range | 1 ppm – 25% O₂ (full-scale selectable per channel) |
| Accuracy | ±3% of reading for 25%–1% O₂ |
| Response Time (T90) | <60 s |
| Output Interface | 4–20 mA / RS485 Modbus RTU / Ethernet (optional) |
| Compliance | Designed to support GLP/GMP-aligned process validation and FDA 21 CFR Part 11 audit-trail readiness via optional software module |
| Brand | Vcam |
|---|---|
| Model | GA2000-1 |
| Origin | Guangdong, China |
| Measurement Range | 25%–1% ±3% |
| Response Time | T90 < 60 s |
| Brand | Vcam |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NS100 |
| Pricing | Available Upon Request |
| Brand | VEGA |
|---|---|
| Origin | Germany |
| Manufacturer | VEGA Grieshaber KG |
| Product Type | Conductive Level Switch |
| Model | EL 1 |
| Electrode Insulation | PTFE |
| Max. Electrode Length | 4 m |
| Compatible Controllers | VEGATOR 131, VEGATOR 132, VEGATOR 130 Series |
| Application | Overflow & Dry-Run Protection |
| Compliance | ATEX, IECEx, SIL 2 (per IEC 61508), RoHS, CE |
| Brand | VEGA |
|---|---|
| Origin | Germany |
| Manufacturer | VEGA Grieshaber KG |
| Product Type | Level Switch |
| Model | VEGASWING 53 |
| Application | Liquid level limit detection (density range: 0.5–2.5 g/cm³) |
| Maximum extension tube length | 1 m |
| Mounting flexibility | Top, side, or bottom |
| Certification | Overflow protection, dry-run protection, pump protection compliant with IEC/EN 61508 SIL 2 and ATEX/IECEx for hazardous areas |
| Enclosure rating | IP66/IP67/IP69K |
| Process connection | G1½", NPT 1½", or flange options |
| Operating temperature | –40 °C to +80 °C (extended range up to +150 °C with optional high-temp fork) |
| Electrical output | PNP/NPN, relay, or 4–20 mA with HART |
| Brand | VEGA |
|---|---|
| Origin | Germany |
| Manufacturer | VEGA Grieshaber KG |
| Product Type | Vibrating Fork Level Switch |
| Model | VEGAVIB 61 |
| Application | Point level detection for bulk solids |
| Density Range | ≥ 20 g/L |
| Design | Compact, hygienic fork geometry with smooth, edge-free surfaces |
| Compliance | ATEX, IECEx, SIL 2 (IEC 61508), IP66/IP67/IP69K, FDA-compliant materials available |