| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OMD-480 |
| Price Range | USD 1,400 – 4,200 (FOB) |
| Measurement Principle | Electrochemical Fuel Cell (Micro-Fuel Cell) |
| Range Options | 0–1% / 0–5% / 0–10% / 0–25% / 0–100% O₂ (selectable) |
| Detection Limit | 0.01 ppm (in low-range configurations) |
| Accuracy | < ±1% FS |
| Temperature Compensation | Built-in, automatic |
| Operating Temp. | –10 to 50 °C |
| Enclosure Dimensions | 241 × 165 × 96 mm |
| Power Supply | 12–24 VDC, 25 mA |
| Output Signals | 4–20 mA, 0–10 VDC, MODBUS RTU over RS485 (ASCII bi-directional) |
| Sample Flow Rate | 230–2500 mL/min |
| Sensor Lifetime | Typically > 24 months (under recommended conditions) |
| Certifications | CE, RoHS |
| Compliance | Designed for use in non-hazardous areas per IEC 61000-6-2/6-4 |
| Sensor Compatibility | Standard fuel cell for N₂, Ar, He, H₂, hydrocarbon matrices |
| Warranty | 12 months from shipment |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OMD-480P |
| Price Range | USD 4,200 – 7,000 (FOB) |
| Sensor Type | Micro-Fuel-Cell Oxygen Sensor |
| Measurement Range | 0–100% O₂ (selectable full-scale ranges: 1%, 5%, 10%, 25%, 100%) |
| Accuracy | < ±1% FS |
| Resolution | 0.01% O₂ (at 0–25% range) |
| Operating Temperature | –10 to +50 °C |
| Temperature Compensation | Built-in, automatic |
| Sample Flow Rate | 230–2500 mL/min |
| Power Supply | 12–24 VDC, 25 mA typical |
| Analog Outputs | 4–20 mA, 0–10 VDC |
| Digital Interface | MODBUS RTU over RS485 (ASCII protocol, bi-directional) |
| Data Storage | Removable 8 GB USB flash drive (log interval configurable) |
| Display | Backlit LCD, auto-ranging |
| Enclosure Dimensions | 241 × 165 × 96 mm (W × H × D) |
| Certifications | CE, RoHS |
| Warranty | 12 months from shipment |
| Compatible Gases | N₂, Ar, He, H₂, CH₄, CO₂ (with acid-resistant sensor option), C₂H₄, and other inert or reducing process gases |
| Optional Sensor Variant | Acid-Resistant Fuel Cell (for H₂S, SO₂, CO₂-containing streams) |
| Compliance | Designed per IEC 61000-6-2/6-4 EMC standards |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OMD-480P |
| Price Range | USD 1,400 – 4,200 (FOB) |
| Measurement Principle | Electrochemical Fuel Cell (Micro-Fuel Cell) |
| Range Options | 0–1%, 0–5%, 0–10%, 0–25%, 0–100% O₂ (selectable) |
| Accuracy | < ±1% FS |
| Resolution | 0.01% (full-scale dependent) |
| Display | Backlit LCD with auto-ranging |
| Operating Temperature | –10 to +50 °C |
| Temperature Compensation | Built-in, automatic |
| Sensor Lifetime | Typically >24 months (air ambient) |
| Power Supply | 12–24 VDC, 25 mA max |
| Analog Outputs | 4–20 mA (isolated), 0–10 VDC |
| Digital Interface | MODBUS RTU over RS485 (ASCII protocol, bi-directional) |
| Sample Flow Rate | 230–2500 mL/min (pump-suction driven) |
| Enclosure Dimensions | 241 × 165 × 96 mm |
| IP Rating | IP65 (front panel) |
| Certifications | CE, RoHS |
| Sensor Compatibility | Standard fuel cell (for N₂, Ar, He, H₂, hydrocarbons) |
| Gas Compatibility | Inert gases (N₂, Ar, He), reducing gases (H₂), non-corrosive process streams |
| Warranty | 12 months from shipment |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OMD-501D |
| Price Range | USD 1,400 – 4,200 (FOB) |
| Measurement Ranges | 0–10 ppm / 0–100 ppm / 0–1,000 ppm / 0–1% / 0–25% O₂ |
| Sensor Type | Miniaturized Electrochemical Fuel Cell |
| Accuracy | < ±1% FS |
| Certifications | CE Marked |
| Dimensions | 241 × 165 × 96 mm |
| Operating Temperature | −10 to +50 °C |
| Temperature Compensation | Built-in |
| Power Supply | 12–24 VDC |
| Current Consumption | 25 mA |
| Analog Outputs | 4–20 mA and 0–10 VDC (isolated) |
| Sample Flow Rate | 230–2,500 mL/min |
| Compatible Gases | N₂, Ar, He, H₂, hydrocarbon streams, and other inert or reducing matrices |
| Acid-Gas Option | Available with H₂S/CO₂/SO₂-resistant sensor |
| Warranty | 12 months |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OMD-507 |
| Price Range | USD $1,400 – $4,200 (FOB) |
| Sensor Technology | Micro-Fuel-Cell |
| Measurement Ranges | 0–10 ppm / 0–100 ppm / 0–1,000 ppm / 0–1 % / 0–25 % / 0–100 % O₂ |
| Accuracy | < ±1 % FS |
| Output Signals | 4–20 mA & 0–10 VDC |
| Sample Flow Rate | 230–2500 mL/min |
| Operating Temperature | −10 to +50 °C |
| Dimensions | 241 × 165 × 96 mm |
| Power Supply | 12–24 VDC |
| Current Draw | 25 mA |
| Temperature Compensation | Built-in |
| Certifications | CE |
| Warranty | 12 months |
| Compatible Gases | N₂, Ar, He, H₂, hydrocarbon streams |
| Sensor Lifetime | >2 years (typical in inert/reducing atmospheres) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OMD-507 |
| Measurement Ranges | 0–10 ppm, 0–100 ppm, 0–1000 ppm, 0–1%, 0–25%, 0–100% |
| Accuracy | <1% FS |
| Sensor Type | Micro Fuel Cell |
| Operating Temperature | –10 to 50 °C |
| Temperature Compensation | Yes |
| Power Supply | 12–24 VDC |
| Current Draw | 25 mA |
| Analog Outputs | 4–20 mA and 0–10 VDC |
| Sample Flow Rate | 230–2500 mL/min |
| Enclosure Dimensions | 241 × 165 × 96 mm |
| Certifications | CE |
| Compatible Gases | N₂, Ar, He, H₂, hydrocarbons (inert or reducing) |
| Warranty | 12 months |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OMD-507 |
| Price Range | USD 1,400 – 4,200 (FOB) |
| Measurement Ranges | 0–10 ppm / 0–100 ppm / 0–1,000 ppm / 0–1 % / 0–25 % (selectable) |
| Accuracy | < ±1 % FS |
| Sensor Type | Miniature Electrochemical Fuel Cell |
| Temperature Compensation | Built-in, Automatic |
| Operating Temp. | –10 to +50 °C |
| Dimensions | 241 × 165 × 96 mm |
| Power Supply | 12–24 VDC |
| Current Draw | 25 mA |
| Analog Outputs | 4–20 mA and 0–10 VDC (isolated) |
| Sample Flow Rate | 230–2,500 mL/min |
| Certifications | CE compliant |
| Warranty | 12 months |
| Compatible Media | N₂, Ar, He, H₂, hydrocarbon streams, and other inert or reducing gases |
| Acid-Gas Option | Available with H₂S/CO₂/SO₂-resistant sensor |
| Enclosure | IP65-rated housing |
| Calibration Interval | Recommended every 6–12 months per ISO 17025 guidelines |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OMD-507 |
| Price Range | USD 1,400 – 4,200 |
| Measurement Ranges | 0–10 ppm, 0–100 ppm, 0–1,000 ppm, 0–1 %, 0–25 %, 0–100 % |
| Accuracy | < ±1 % FS |
| Certifications | CE |
| Dimensions | 241 × 165 × 96 mm |
| Operating Temperature | –10 to +50 °C |
| Temperature Compensation | Yes |
| Sensor Type | Micro-fuel-cell oxygen sensor |
| Warranty | 12 months |
| Power Supply | 12–24 VDC |
| Current Consumption | 25 mA |
| Output Signals | MODBUS RTU over RS485 (ASCII), 4–20 mA, 0–10 VDC |
| Sample Flow Rate | 230–2500 mL/min |
| Compatible Gases | N₂, Ar, He, H₂, hydrocarbon mixtures |
| Enclosure | IP65-rated housing (standard) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OMD-525 |
| Price Range | USD 1,400 – 4,200 (FOB) |
| Measurement Principle | Electrochemical Fuel Cell (Micro-Fuel Cell) |
| Range Options | 0–10 ppm / 0–100 ppm / 0–1,000 ppm / 0–1% / 0–25% O₂ |
| Accuracy | < ±1% FS |
| Temperature Compensation | Integrated |
| Operating Temp. | −10 to +50 °C |
| Enclosure Dimensions | 241 × 165 × 96 mm |
| Power Supply | 12–24 VDC |
| Current Draw | 25 mA |
| Output Signals | 4–20 mA, 0–10 VDC, MODBUS RS485 (ASCII, bi-directional) |
| Sample Flow Rate | 230–2500 mL/min |
| Sensor Lifetime | >24 months (typical, under specified conditions) |
| Certifications | CE, RoHS |
| Sensor Compatibility | Standard fuel cell |
| Compatible Carrier Gases | N₂, Ar, He, H₂, hydrocarbon streams (non-corrosive, non-oxidizing) |
| Warranty | 12 months from shipment |
| Brand | Southland Sensing |
|---|---|
| Model | OMD-525X |
| Origin | USA |
| Housing | ABS, IP65-rated |
| Sensor Types | TO2-1x (0–10 ppm), TO2-2x (0–10 ppm), PO2-160/24/1120 (0–100% O₂) |
| Measurement Range | 0.01 ppm–100% O₂ (selectable via hardware switch) |
| Accuracy | ±1% of reading |
| Response Time (t₉₀) | ≤15 s |
| Operating Temp. | 5–45°C (TO2), −20–45°C (PO2) |
| Pressure Range | 0–3 MPa inlet, ambient exhaust |
| Flow Rate | 0.25–2.5 L/min (recommended: 1 L/min) |
| Output | 4–20 mA analog + dual relay alarms |
| Power | 9–28 VDC |
| Display | Backlit LCD, 0.01 ppm resolution |
| Data Storage | 8 GB USB logging |
| Compensation | Automatic temperature & pressure |
| Calibration | Certified span gas (~80% of selected range) |
| Sensor Lifetime | 24 months at 25°C |
| Warranty | 12 months (instrument & sensor) |
| Enclosure Rating | IP65 |
| Sample Interface | 1/4" compression fittings |
| Linearity | >0.995 R² across full scale |
| Sensitivity | <0.5% FS |
| Sample Compatibility | N₂, Ar, He, H₂, CO₂, C₂H₂, C₂H₄, C₄H₆, hydrocarbons (CnHm), and inert or reducing matrices |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OMD-580 |
| Price Range | USD 1,400 – 4,200 (FOB) |
| Measurement Principle | Electrochemical Fuel Cell (Micro-Fuel Cell) |
| Range Options | 0–1 ppm, 0–10 ppm, 0–100 ppm, 0–1,000 ppm, 0–1%, 0–25%, 0–100% O₂ |
| Accuracy | < ±1% FS |
| Operating Temp. | –10 to 50 °C |
| Output Signals | 4–20 mA, 0–10 VDC, MODBUS RTU over RS485 (ASCII bi-directional) |
| Power Supply | 12–24 VDC |
| Current Draw | 25 mA |
| Sample Flow Rate | 230–2500 mL/min |
| Enclosure Dimensions | 241 × 165 × 96 mm |
| Certifications | CE, RoHS |
| Temperature Compensation | Built-in |
| Sensor Lifetime | Typically >2 years (field-replaceable) |
| Compatible Gases | N₂, Ar, He, H₂, CH₄, CO₂ (with acid-resistant sensor option), C₂H₄, etc. |
| Optional Sensor Configurations | Standard fuel cell |
| Warranty | 12 months from shipment |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OMD-625 |
| Price Range | USD 4,200 – 7,000 (FOB) |
| Certifications | CE, ATEX/IECEx Class I, Div 2, Groups B, C, D Compliant |
| Measurement Ranges | 0–10 ppm / 0–100 ppm / 0–1,000 ppm / 0–1% / 0–25% O₂ |
| Accuracy | < ±1% FS |
| Sensor Type | Electrochemical Fuel Cell (Micro-Fuel Cell) |
| Operating Temperature | −10 to +50 °C |
| Temperature Compensation | Integrated |
| Power Supply | 12–24 VDC |
| Current Draw | 25 mA |
| Output Signals | 4–20 mA, 0–10 VDC, MODBUS RTU over RS485 (ASCII bi-directional) |
| Sample Flow Rate | 230–2500 mL/min |
| Enclosure Dimensions | 241 × 165 × 96 mm |
| Sensor Lifetime | >24 months typical (dependent on exposure profile) |
| Warranty | 12 months |
| Compatible Gases | N₂, Ar, He, H₂, CH₄, CO₂ (with acid-resistant sensor option), natural gas streams, syngas, inert/reducing atmospheres |
| Optional Acid-Resistant Sensor | Available for H₂S, SO₂, and CO₂-laden streams |
| Calibration | Zero & span via external gas ports or digital interface |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OMD-625-M |
| Price Range | USD 4,200 – 7,000 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OMD-625D |
| Price Range | USD 4,200 – 7,000 |
| Certification | UL Class I, Div 2, Groups B, C, D |
| Measurement Ranges | 0–10 ppm / 0–100 ppm / 0–1000 ppm / 0–1% / 0–25% O₂ |
| Accuracy | < ±1% FS |
| Sensor Type | Micro-fuel-cell (electrochemical) |
| Operating Temperature | −10 to +50 °C |
| Sample Flow Rate | 230–2500 mL/min |
| Output Signals | 4–20 mA, 0–10 VDC, MODBUS RTU over RS485 (ASCII bi-directional) |
| Power Supply | 12–24 VDC |
| Current Consumption | 25 mA |
| Dimensions | 241 × 165 × 96 mm |
| Temperature Compensation | Built-in |
| Enclosure Rating | IP65 |
| Sensor Lifetime | Typically >24 months in clean inert gas streams |
| Compliance | Meets IEC 60079-0, IEC 60079-11, ATEX Directive 2014/34/EU (via equivalent Class I, Div 2 certification), FDA 21 CFR Part 11 ready (when integrated with compliant SCADA/HMI) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OMD-640 |
| Price Range | USD 1,400 – 4,200 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OMD-645 |
| Price Range | USD 1,400 – 4,200 |
| Sensor Technology | Micro-Fuel-Cell |
| Measurement Range | 0–1 ppm / 0–10 ppm / 0–100 ppm / 0–1,000 ppm / 0–25% O₂ (auto-ranging) |
| Accuracy | < ±1% FS |
| Operating Temperature | −10 to +50 °C |
| Output Signals | 4–20 mA, 0–10 VDC, MODBUS RS485 (ASCII, bi-directional) |
| Power Supply | 12–24 VDC, 25 mA |
| Sample Flow Rate | 230–2500 mL/min (with integrated needle valve, bypass valve, flowmeter & 4-way selector) |
| Data Storage | Removable 8 GB USB flash drive |
| Display | Backlit LCD with auto-scaling range indication |
| Certifications | CE |
| Enclosure Dimensions | 241 × 165 × 96 mm |
| Temperature Compensation | Built-in |
| Compatible Gases | N₂, Ar, He, H₂, CH₄, C₂H₆, and other inert/reducing gases |
| Acidic Gas Options | Optional H₂S/CO₂/SO₂-resistant sensor variant available |
| Warranty | 12 months |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | OMD-675-1 |
| Price Range | USD 4,200 – 7,000 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OMD-675-10 |
| Measurement Ranges | 0–10 ppm, 0–100 ppm, 0–1,000 ppm, 0–1% O₂, 0–25% O₂ |
| Sensor Type | Micro-fuel-cell electrochemical sensor |
| Accuracy | <1% FS |
| Certifications | CE, Class I, Div 2, Groups B, C, D |
| Operating Temperature | –10 to 50 °C |
| Dimensions | 241 × 165 × 96 mm |
| Power Supply | 12–24 VDC, 25 mA |
| Output Signals | 4–20 mA, 0–10 VDC, MODBUS RS485 (ASCII, bi-directional) |
| Sample Flow Rate | 230–2500 mL/min |
| Temperature Compensation | Integrated |
| Warranty | 12 months |
| Compatible Gases | N₂, Ar, He, H₂, hydrocarbons, CO₂ (with acid-resistant sensor option), H₂S/SO₂/CO₂ (with optional corrosion-resistant sensor) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OMD-677-1 |
| Price Range | USD 4,200 – 7,000 |
| Measurement Ranges | 0–10 ppm / 0–100 ppm / 0–1,000 ppm / 0–1% / 0–25% O₂ |
| Accuracy | < ±1% FS |
| Sensor Type | Miniature Fuel Cell (Electrochemical) |
| Operating Temperature | −10 to +50 °C |
| Sample Flow Rate | 230–2,500 mL/min |
| Output Signals | 4–20 mA, 0–10 VDC, MODBUS RTU over RS485 (ASCII bi-directional) |
| Power Supply | 12–24 VDC |
| Current Consumption | 25 mA |
| Enclosure Dimensions | 241 × 165 × 96 mm |
| Certifications | CE |
| Temperature Compensation | Built-in |
| Optional Sensor Variant | Acid-Gas Resistant (for CO₂, H₂S, SO₂ environments) |
| Warranty | 12 months |
| Compatible Media | N₂, Ar, He, H₂, hydrocarbon streams, and other inert or reducing gases |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OMD-677-1 |
| Price Range | USD 4,200 – 7,000 |
| Measurement Range | 0–1 ppm, 0–10 ppm, 0–100 ppm, 0–1,000 ppm, 0–25% O₂ |
| Accuracy | < ±1% FS |
| Certifications | CE |
| Dimensions | 241 × 165 × 96 mm |
| Operating Temperature | −10 to +50 °C |
| Temperature Compensation | Built-in |
| Sensor Type | Micro-fuel-cell electrochemical sensor |
| Warranty | 12 months |
| Sample Gas Flow Rate | 230–2500 mL/min |
| Power Supply | 12–24 VDC |
| Current Consumption | 25 mA |
| Analog Outputs | 4–20 mA and 0–10 VDC |
| Compatible Gases | N₂, Ar, He, H₂, hydrocarbon streams (non-acidic) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OMD-677-10 |
| Measurement Ranges | 0–10 ppm, 0–100 ppm, 0–1000 ppm, 0–1%, 0–25% O₂ |
| Accuracy | <1% FS |
| Sensor Type | Micro-fuel-cell (electrochemical) |
| Operating Temperature | –10 to 50 °C |
| Enclosure Dimensions | 241 × 165 × 96 mm |
| Power Supply | 12–24 VDC, 25 mA |
| Output Signals | 4–20 mA, 0–10 VDC, MODBUS RTU over RS485 (ASCII bi-directional) |
| Sample Flow Rate | 230–2500 mL/min |
| Temperature Compensation | Built-in |
| Certifications | CE |
| Warranty | 12 months |
| Compatible Gases | N₂, Ar, He, H₂, hydrocarbons |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OMD-740 |
| Price Range | USD 4,200 – 7,000 (FOB) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OMD-775 |
| Price Range | USD 6,800 – 13,600 (FOB) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PO2-1120 |
| Output Signal | 285–590 µA (fuel cell, linear vs. O₂ concentration) |
| Measurement Ranges | 0–1%, 0–5%, 0–10%, 0–25%, 0–100% O₂ (selectable via configuration) |
| Response Time (T90) | ≤13 s |
| Full-Scale Accuracy | ±1% FS |
| Repeatability | ±0.5% FS |
| Temperature Coefficient | 2.54%/°C |
| Operating Temperature | 0–50°C |
| Storage Temperature | 0–45°C |
| Recommended Flow Rate | 0.5–5 SCFH |
| Humidity Range | 0–100% RH (non-condensing) |
| Expected Service Life | 20–25 months (under nominal operating conditions) |
| Warranty | 12 months |
| Electrical Interface | PCB-mounted, center foil (negative), outer foil (positive) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PO2-160 |
| Price Range | USD 1–9,999 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PO2-1X |
| Price Range | USD 1–9,999 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PO2-24 |
| Price Range | USD 1–9,999 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PO2-2X |
| Price Range | USD 1–9,999 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TO2-133 |
| Price Range | USD 1–9,999 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TO2-133-T |
| Output Signal | 285–590 µA (linear vs. O₂ concentration) |
| Measurement Ranges | 0–1 ppm / 0–10 ppm / 0–100 ppm / 0–1000 ppm / 0–1% / 0–25% O₂ (auto-ranging) |
| Response Time (T₉₀) | ≤13 s |
| Full-Scale Accuracy | ±1% FS |
| Repeatability | ±0.5% FS |
| Temperature Coefficient | 2.54%/°C |
| Operating Temp. | 0–50°C |
| Storage Temp. | 0–45°C |
| Recommended Flow Rate | 0.5–5 SCFH |
| Humidity Range | 0–100% RH (non-condensing) |
| Expected Service Life | 20–25 months (under typical operating conditions) |
| Warranty | 12 months |
| Electrical Interface | PCB-mounted, center foil (cathode), outer foil (anode) |