Other Industrial Process Control & Online Analyzers
Filter
Showing 391–420 of 553 results
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | SFA |
| Pricing | Upon Request |
| Brand | Shanda |
|---|---|
| Model | SD-NIR-AC |
| Housing Material | 304 Stainless Steel |
| Measurement Principle | Near-Infrared Reflectance Spectroscopy (NIRS) at Water-Absorbing Wavelengths (e.g., 1450 nm, 1940 nm) |
| Moisture Range | 0–100% w/w |
| Accuracy | ±0.2% w/w (under stable composition conditions) |
| Temperature Compensation | Built-in, automatic |
| Optical Path | Non-contact, reflective configuration |
| Spot Diameter | 60–75 mm |
| Measurement Height | 350 mm ± 100 mm |
| Optical Window | High-borosilicate quartz glass |
| Light Source | Imported high-stability NIR LED/Laser |
| Signal Processing | Full digital signal processing with adaptive digital filtering |
| Output Interfaces | RS485, 4–20 mA, RS232, Ethernet (LAN), LoRa wireless |
| Power Supply | 220 VAC / 50 Hz |
| Power Consumption | 60 W |
| Operating Environment | −40 °C to +70 °C, 5–95% RH (non-condensing) |
| Ingress Protection | IP65 |
| Optional Features | Integrated temperature sensing (0–500 °C), multi-channel spectral acquisition (50 channels) |
| Brand | Baoying Technology |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | C1000 |
| Price Range | USD 28,000 – 70,000 |
| Brand | Shengyan Ultrasonics / SYCS |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SCQ-170206B |
| Price | USD 26,500 (FOB Shanghai) |
| Overall Dimensions (L×W×H) | 6000 × 1500 × 1200 mm |
| Power Supply | AC 220 V, 50 Hz ±10% |
| Total Power Consumption | ~80 kW |
| Tank Capacity (per tank) | 525 L |
| Tank Material | Full SUS304 stainless steel (2.5 mm wall thickness for Tanks 1–2 |
| Heating Power (Tanks 1, 2 & 4) | 12 kW each |
| Temperature Range | Ambient to 80 °C |
| Timer Units | Dual independent timers (Yatai, Shanghai) |
| Temperature Display | Omron digital controller |
| Filtration System | Stainless steel housing (Ø220 × 830 mm) with #2 filter bag |
| Circulation Pump | Ø300 mm × 980 mm (stainless steel wetted parts) |
| Insulation | Integral thermal insulation layer |
| Air Agitation | Pneumatic stirrer (TMH-0.1, Shanghai Maiyang) — external compressed air supply required |
| Inlet/Drain/Overflow Ports | Standard rear-mounted drain outlets with overflow weir |
| Basket Support | Reinforced stainless steel mesh frame (load-rated) |
| Brand | Shinsei |
|---|---|
| Origin | Japan |
| Model | XO-326IIs |
| Sensor Type | Galvanic (Diffusion-Type Membrane) |
| Measurement Range | O₂: 0–25.0 vol% |
| Full-Scale Extended Range | 25.1–40.0 vol% |
| Accuracy | ±0.5 vol% |
| Response Time (t₉₀) | ≤20 s |
| Repeatability | ±0.5 vol% (typical) |
| Resolution | 0.1 vol% (3-digit LCD display) |
| Operating Temperature | 0–40 °C |
| Power Supply | Two AA alkaline batteries |
| Battery Life | Approx. 8,000 hours continuous operation |
| Enclosure Rating | Intrinsically Safe Ex ia IIB T3 |
| Dimensions (XO-326IIsB variant) | 66 × 120 × 29 mm |
| Weight (XO-326IIsB) | ~265 g |
| Brand | SIELINS |
|---|---|
| Model | XLZ-1090JRC |
| Measurement Principle | Paramagnetic Detection |
| Measurement Range | 0–100% O₂ (selectable sub-ranges: 0–2%, 0–5%, 0–10%, 0–21%, 0–50%, 0–100%) |
| Zero Drift | ±2% FS |
| Span Drift | ±2% FS/year |
| Linearity Error | ±1% FS |
| Repeatability | ≤1% FS |
| Response Time (T₉₀) | ≤40 s |
| Power Consumption | <80 W |
| Supply Voltage | 220 ± 22 VAC, 50 Hz |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤80% RH (non-condensing) |
| Weight | ~15 kg |
| Enclosure | 19″ rack-mount chassis (4U height) |
| Output Signals | Isolated 4–20 mA (default, load ≤400 Ω) and 1–5 V DC (default, load ≥250 Ω) |
| Communication Interface | RS232 |
| Environmental Requirements | Non-corrosive atmosphere |
| Brand | SIELINS |
|---|---|
| Model | XLZ-1090JRD |
| Measurement Principle | Thermal Conductivity Detection |
| Measurement Range | 0–100% H₂ (selectable sub-ranges: 0–1%, 0–10%, 35–75%, 40–80%, 75–100%, 80–100%) |
| Zero Drift | ±1% FS |
| Span Drift | ±1% FS |
| Linearity Error | ±1% FS |
| Repeatability | ≤0.5% FS |
| Response Time (T₉₀) | ≤25 s |
| Power Consumption | <80 W (including heater) |
| Supply Voltage | (220 ± 22) VAC, (50 ± 0.5) Hz |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤80% RH |
| Enclosure | 19" rack-mount chassis (standard industrial format) |
| Output Signals | Isolated 4–20 mA (default), 0–20 mA, 0–5 V, 1–5 V (load-dependent) |
| Communication Interface | RS232 (ASCII protocol) |
| Weight | ~10 kg |
| Environmental Constraints | Non-corrosive atmosphere |
| Brand | SIGAS |
|---|---|
| Origin | Jiangsu, China |
| Model | S-SYSTEM CEMS |
| Detection Gases | Flue Gas |
| Accuracy | ±1% FS |
| Response Time | T90 < 2 s at 60 L/h flow |
| Warm-up Time | ~2 min |
| Resolution | 0.01 ppm |
| Linearity Error | ≤ ±2% FS to ±5% FS |
| Zero Calibration | Clean Air |
| Inlet Gas Temperature Range | 5–30 °C |
| Display Units | ppm, mg/m³ |
| Output Signals | 4–20 mA, RS485 |
| Enclosure Rating | IP42 (EN 60529) |
| Brand | Sinoptic |
|---|---|
| Model | iLAS |
| Type | In-Situ Cross-Beam Tunable Diode Laser Absorption Spectroscopy (TDLAS) Gas Analyzer |
| Origin | Hubei, China |
| Manufacturer | Sinoptic Instrument Co., Ltd. |
| Explosion Protection | Exd II CT6 |
| IP Rating | IP66 |
| Optical Path Length | ≤15 m |
| Sample Gas Temperature | ≤800 °C |
| Ambient Temperature | −30 to 55 °C |
| Humidity | ≤90% RH (non-condensing) |
| Power Supply | AC 220 V / DC 24 V |
| Analog Inputs | 2 × 4–20 mA |
| Analog Outputs | 2 × 4–20 mA (max. load 750 Ω) |
| Digital Interface | RS485, MODBUS RTU |
| Relay Outputs | 3 × (24 V, 1 A) |
| Purge Gas | N₂, 0.4–0.6 MPa |
| Measurable Gases | O₂, CO, CO₂, CH₄, NH₃, HCl, HF, H₂S, C₂H₆, HCN, H₂O (customizable) |
| Detection Limit | 0.01% vol |
| Full Scale Range | 0–99.99% vol |
| Operating Pressure | Atmospheric ±5 kPa |
| Brand | Sinoptic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | iLAS-200 |
| Pricing | Upon Request |
| Brand | SITA |
|---|---|
| Origin | Germany |
| Model(s) | CleanoSpector, ProLinet15, ConSpector |
| Measurement Principle | Bubble Pressure Method (Dynamic/Static Surface Tension), UV-Induced Fluorescence (Contamination Quantification), Confocal UV Fluorescence (Surface Residue Detection) |
| Compliance | Designed for ISO 9001, IATF 16949, and GLP-aligned process validation |
| Software | SITA LabSoft v5.2 with Audit Trail, Data Export (CSV/PDF), Multi-User Access Control |
| Certifications | CE, RoHS, Factory Calibration Certificate per Unit |
| Operating Environment | 10–40 °C, 30–80% RH non-condensing |
| Brand | Southland |
|---|---|
| Origin | USA |
| Model | H2S-150-NG |
| Measurement Principle | Electrochemical Fuel Cell Sensor |
| Range Options | 0–200 ppm (H2S-1X) or 0–2000 ppm (H2S-2X) |
| Accuracy | < ±2% of Full Scale |
| Response Time (T90) | 60 s |
| Operating Temperature | 0–50 °C |
| Sample Flow Rate | 0.5–2.0 SCFH |
| Inlet Pressure Range | 0.1–50 PSI |
| Output Signal | 4–20 mA or 1–5 VDC |
| Enclosure Rating | Class 1, Div 2, Groups C & D |
| Dimensions | 11.25 × 12.0 × 5.50 in |
| Weight | 12.5 lbs |
| Sensor Lifetime | 12 months |
| Calibration Interval | Every 1–3 months with certified span gas |
| Gas Connection | 1/4" compression fitting |
| Electrical Isolation | Galvanically isolated power and analog outputs |
| Optional | Dual-loop configuration, RS-485 Modbus RTU interface |
| Brand | Southland |
|---|---|
| Origin | USA |
| Model | H2S-625 |
| Linear Error | < ±1% FS |
| Repeatability | < ±1% FS |
| Span Drift | < ±1% FS |
| Response Time (T90) | 45 s |
| Explosion Protection Rating | Class I, Division 1, Group B, C, D |
| Brand | Southland |
|---|---|
| Model | MOMD-525 |
| Measurement Principle | Electrochemical Fuel Cell (TO2-1x Sensor) |
| Range Options | 0–10 ppm / 0–100 ppm / 0–1,000 ppm / 0–1% / 0–25% O₂ |
| Accuracy | < ±1% FS |
| Response Time | T₉₀ ≤ 10 s |
| Operating Temperature | 0–50 °C |
| Enclosure Rating | IP66 / NEMA 4X |
| Output Signal | 4–20 mA (isolated) |
| Power Supply | 14–28 VDC or 100–240 VAC via included adapter |
| Display | Color backlit LCD |
| Data Logging | USB flash drive (up to 8 GB, supports ~50 years of timestamped data) |
| Sensor Lifetime | 20–25 months |
| Calibration | Manual zero/span via front panel or remote command |
| Mounting | Wall-mounted |
| Warranty | 12 months |
| Brand | Southland |
|---|---|
| Model | MOMD-580 |
| Measurement Range | 0–10 ppm / 0–100 ppm / 0–1000 ppm / 0–1% O₂ / 0–25% O₂ |
| Accuracy | ±1% of Full Scale |
| Power Supply | Rechargeable Lithium-ion Battery |
| Display | Color Digital LCD |
| Ingress Protection | IP66 / NEMA 4X |
| Origin | Beijing, China |
| Distribution Type | Authorized Distributor |
| Brand | Southland |
|---|---|
| Model | MOMD-640 |
| Origin | USA |
| Measurement Range | 0–1 ppm, 0–10 ppm, 0–100 ppm, 0–1,000 ppm, 0–25% O₂ |
| Accuracy | <1% FS |
| Response Time (T90) | 10 s |
| Operating Temperature | 0–50 °C |
| Dimensions | 10.9 × 10.0 × 4.9 in |
| Weight | 11.75 lb |
| Housing | Brushed Stainless Steel |
| Inlet Pressure Range | 0–50 PSI |
| Power | Rechargeable Battery + 100–240 VAC Adapter |
| Sensor Lifetime | 20–25 months |
| Analog Output | 0–1 VDC |
| Data Storage | Removable 8 GB USB Flash Drive (CSV format, supports >50 years of logging at 1-min intervals) |
| Display | Backlit, Sunlight-Readable LCD |
| Sensor Type | Electrochemical Fuel Cell (SSO2 series) |
| Warranty | 12 months |
| Compliance | Designed for GLP-compliant field use |
| Brand | Southland |
|---|---|
| Origin | Beijing, China |
| Model | MTO2-133 |
| Measurement Principle | Microcombustion Cell |
| Output Signal | 520–1020 µA |
| Range | 0–10 ppm (Low Range) / 0–10,000 ppm (Full Scale) |
| Response Time (T90) | 7 s |
| Accuracy | ±1% FS |
| Repeatability | ±0.5% FS |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OMD-150-M |
| Price Range | USD 1,400 – 4,200 |
| Measurement Ranges | 0–10 ppm / 0–100 ppm / 0–1,000 ppm / 0–1 % / 0–25 % / 0–100 % (configurable per sensor variant) |
| Accuracy | < ±1 % FS |
| Certifications | CE |
| Dimensions | 241 × 165 × 96 mm |
| Operating Temperature | −10 to +50 °C |
| Temperature Compensation | Built-in |
| Sensor Type | Miniaturized Electrochemical Fuel Cell |
| Power Supply | 12–24 VDC |
| Current Consumption | 25 mA |
| Analog Output | 6-wire MODBUS RTU |
| Sample Flow Rate | 230–2500 mL/min |
| Compatible Media | N₂, Ar, He, H₂, hydrocarbon streams |
| Warranty | 12 months |
| Intrinsic Safety Option | Available with MTL Zener barrier integration |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OMD-401D |
| Price Range | USD 1,400 – 4,200 |
| Measurement Ranges | 0–1%, 0–5%, 0–10%, 0–25%, 0–100% O₂ (selectable) |
| Accuracy | < ±1% FS |
| Certifications | CE |
| Dimensions | 241 × 165 × 96 mm |
| Operating Temperature | −10 to +50 °C |
| Temperature Compensation | Built-in |
| Sensor Type | Micro-fuel-cell electrochemical oxygen sensor |
| Warranty | 12 months |
| Power Supply | 12–24 VDC |
| Current Draw | 25 mA |
| Analog Outputs | 4–20 mA and 0–10 VDC (isolated, configurable) |
| Sample Flow Rate | 230–2500 mL/min |
| Compatible Media | N₂, Ar, He, H₂, hydrocarbon streams, and other inert or reducing gases |
| Acid-Gas Option | Available with acid-resistant sensor for CO₂, H₂S, or SO₂-containing streams |
| Enclosure Rating | IP65 (industrial-grade front panel) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OMD-675 |
| Price Range | USD 4,200 – 7,000 |
| Brand | Southland Sensing |
|---|---|
| Origin | Beijing, China |
| Model | FSR-600FB |
| Linear Error | ≤ ±1% F.S. |
| Repeatability | ≤ ±1% F.S. |
| Span Drift | ≤ ±1% F.S. / 7 days |
| Response Time (T90) | ≤ 1 s |
| Explosion Protection Rating | Ex d II C T6 |
| Sample Flow Rate | 0.3–0.5 L/min |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Operating Temperature | −5 °C to +45 °C |
| Relative Humidity | ≤ 90% RH |
| Inlet Pressure Range | 0.05–0.1 MPa |
| Analog Output | 4–20 mA |
| Electrical Interface | 1/2 NPT |
| Sample Port | G1/2 |
| Zero Drift | ±1% F.S. / 7 days |
| Resolution | 0.01% vol |
| Warm-up Time | 10 min |
| MTBF | > 3 years |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | H2S-150 |
| Price Range | USD 1,400 – 4,200 |
| Measurement Ranges | 0–10, 0–50, 0–100, 0–200, 0–500, 0–1,000, 0–2,000 ppm (selectable, auto/manual switching) |
| Accuracy | < ±2% FS |
| Certifications | CE, UL Class I, Div 1, Groups B, C, D |
| Dimensions | 241 × 165 × 96 mm |
| Operating Temperature | −10 to +50 °C |
| Temperature Compensation | Built-in |
| Sensor Type | Electrochemical Fuel Cell (H₂S-specific) |
| Power Supply | 12–24 VDC |
| Current Draw | 25 mA |
| Output Signals | 4–20 mA, 0–10 VDC, MODBUS RTU over RS-485 (ASCII bi-directional) |
| Sample Flow Rate | 230–2500 mL/min |
| Enclosure Rating | IP65 |
| Warranty | 12 months |
| Sample Media | Natural gas streams, biogas, sour gas, treated/untreated process gas |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | H2S-150-NG |
| Measurement Range | 0–10 / 0–50 / 0–100 / 0–200 / 0–500 / 0–1000 / 0–2000 ppm (selectable, auto/manual switching) |
| Accuracy | < ±2% FS |
| Certifications | CE, UL Class I, Div 1, Groups B, C, D |
| Dimensions | 241 × 165 × 96 mm |
| Operating Temperature | –10 to +50 °C |
| Temperature Compensation | Yes |
| Sensor Technology | Electrochemical Fuel Cell (H₂S-specific) |
| Power Supply | 12–24 VDC |
| Current Consumption | 25 mA |
| Output Signals | 4–20 mA, 0–10 VDC, MODBUS RTU over RS-485 (ASCII bi-directional) |
| Sample Flow Rate | 230–2500 mL/min |
| Sample Medium | Natural gas streams (pre- and post-desulfurization), landfill gas, refinery off-gas |
| Warranty | 12 months |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | H2S-725 |
| Measurement Ranges | 0–10, 0–50, 0–100, 0–200, 0–500, 0–1000, 0–2000 ppm (selectable, auto/manual switching) |
| Accuracy | < ±2% FS |
| Certifications | CE, UL Class I, Div 1, Groups B, C, D |
| Operating Temperature | −10 to +50 °C |
| Sensor Type | Micro-fuel-cell electrochemical H₂S sensor |
| Warm-up Time | < 60 s |
| Response Time (T90) | < 30 s |
| Output Signals | 4–20 mA, 0–10 VDC, MODBUS RTU over RS485 (ASCII bi-directional) |
| Power Supply | 12–24 VDC, 25 mA typical |
| Sample Flow Rate | 230–2500 mL/min (with integrated 4-way valve, bypass, needle valve & rotameter) |
| Dimensions | 241 × 165 × 96 mm |
| Temperature Compensation | Built-in |
| Warranty | 12 months |
| Sample Media | Natural gas, biogas, sour gas streams in upstream & midstream processing |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | H2S-725D |
| Measurement Ranges | 0–10, 0–50, 0–100, 0–200, 0–500, 0–1000, 0–2000 ppm (selectable & auto-switching) |
| Accuracy | < ±2% FS |
| Certifications | CE, UL Class I, Div 1, Groups B, C, D |
| Operating Temperature | −10 to +50 °C |
| Sensor Type | Micro-fuel-cell electrochemical H₂S sensor |
| Output | 4–20 mA, 0–10 VDC, MODBUS RTU over RS-485 (ASCII bi-directional) |
| Power Supply | 12–24 VDC |
| Current Consumption | 25 mA |
| Sample Flow Rate | 230–2500 mL/min |
| Dimensions | 241 × 165 × 96 mm |
| Temperature Compensation | Integrated |
| Warranty | 12 months |
| Compliance | Designed for hazardous area installation per NEC/CEC Article 500 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | H2S-725M |
| Measurement Ranges | 0–10, 0–50, 0–100, 0–200, 0–500, 0–1000, 0–2000 ppm (user-selectable or auto-ranging) |
| Accuracy | < ±2% FS |
| Certifications | CE, UL Class I, Div 1, Groups B, C, D |
| Dimensions | 241 × 165 × 96 mm |
| Operating Temperature | –10 to +50 °C |
| Temperature Compensation | Built-in |
| Sensor Type | Micro-fuel-cell electrochemical H₂S sensor |
| Power Supply | 12–24 VDC |
| Current Draw | 25 mA |
| Output Signals | 4–20 mA, 0–10 VDC, MODBUS RTU over RS-485 (ASCII bi-directional) |
| Sample Flow Rate | 230–2500 mL/min (with integrated 4-way sampling valve, bypass valve, needle valve, and flowmeter) |
| Warranty | 12 months |
| Application Media | Natural gas streams, biogas, sour gas, desulfurized process gas |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | H2S-780 |
| Measurement Ranges | 0–10, 0–50, 0–100, 0–200, 0–500, 0–1000, 0–2000 ppm (selectable & auto-switching) |
| Accuracy | < ±2% FS |
| Certifications | CE, UL Class I, Div 1, Groups B, C, D |
| Operating Temperature | –10 to +50 °C |
| Sensor Type | Electrochemical (Fuel Cell) H₂S Sensor |
| Output | 4–20 mA, 0–10 VDC, MODBUS RTU over RS-485 (ASCII bi-directional) |
| Power Supply | 12–24 VDC |
| Current Draw | 25 mA |
| Sample Flow Rate | 230–2500 mL/min |
| Dimensions | 241 × 165 × 96 mm |
| Temperature Compensation | Yes |
| Warranty | 12 months |
| Sample Medium | Natural gas streams (upstream, midstream, and processing environments) |
| Brand | Southland Sensing |
|---|---|
| Model | MOMD-480 |
| Origin | USA (California) |
| Measurement Principle | Electrochemical Fuel Cell |
| Range Options | 0–1%, 0–5%, 0–10%, 0–25%, 0–100% O₂ (selectable) |
| Accuracy | < ±1% FS |
| Response Time | ≤10 s to T90 |
| Operating Temperature | 0–50 °C |
| Gas Pressure Range | 0–50 PSI (inlet) |
| Power | Rechargeable Li-ion battery + 100–240 VAC adapter |
| Dimensions | 8.80 × 7.50 × 3.90 in (223.5 × 190.5 × 99.1 mm) |
| Weight | 4.8 lb (2.18 kg) |
| Enclosure Material | Polypropylene |
| Sensor Lifetime | 60 months |
| Analog Output | 0–1 VDC |
| Data Logging | USB flash drive (up to 8 GB, supports >50 years of timestamped data at 1-min intervals) |
| Display | Backlit high-contrast LCD |
| Warranty | 12 months |
| Compliance | Designed for GLP-compliant field use |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OMD-150 |
| Price Range | USD 1–9,999 |
| Safety Option | Intrinsically Safe (MTL Zener Barrier Compatible) |
| Measurement Ranges | 0–10 ppm, 0–100 ppm, 0–1,000 ppm, 0–1 %, 0–25 %, 0–100 % O₂ (configurable per sensor variant: TO2-1x, TO2-2x, PO2-160, PO2-24) |
| Accuracy | < ±1 % FS |
| Certifications | CE |
| Dimensions | 241 × 165 × 96 mm |
| Operating Temperature | –10 to +50 °C |
| Temperature Compensation | Integrated |
| Sensor Type | Miniaturized Electrochemical Fuel Cell |
| Warranty | 12 months |
| Power Supply | 12–24 VDC |
| Current Draw | 25 mA |
| Analog Outputs | 4–20 mA and 0–10 V (isolated) |
| Sample Flow Rate | 230–2500 mL/min |
| Compatible Gas Matrices | N₂, Ar, He, H₂, hydrocarbon streams |
| Enclosure Rating | IP65 (standard) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OMD-150-1 |
| Measurement Ranges | 0–1 ppm, 0–10 ppm, 0–100 ppm, 0–1000 ppm, 0–25% O₂ |
| Accuracy | <1% FS |
| Certifications | CE, Optional ATEX/IECEx Intrinsically Safe (with MTL Zener barrier) |
| Dimensions | 241 × 165 × 96 mm |
| Operating Temperature | –10 to 50 °C |
| Temperature Compensation | Built-in |
| Sensor Type | Miniaturized Electrochemical Fuel Cell |
| Warranty | 12 months |
| Power Supply | 12–24 VDC |
| Current Consumption | 25 mA |
| Analog Outputs | 4–20 mA and 0–10 VDC |
| Sample Flow Rate | 230–2500 mL/min |
| Compatible Gases | N₂, Ar, He, H₂, other inert or reducing gases (H₂S/SO₂/CO₂-compatible variants available on request) |