| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LIF/PLIF Combustion Diagnostics System |
| Pricing | Available Upon Request |
| Tunable Dye Laser Wavelength Range | 220–780 nm (extendable to 200–4500 nm) |
| Spectral Linewidth | 0.06 cm⁻¹ |
| Pulse Energy | 110 mJ @ 560 nm |
| Laser Repetition Rate | 10 Hz |
| Laser Sheet Thickness | 0.1–0.3 mm |
| Temporal Delay Range | 0–2000 s |
| Timing Resolution | 5 ps |
| Synchronization Channels | 4 (expandable to 8) |
| ICCD Optical Gate Width | <2 ns |
| ICCD Delay Resolution | 10 ps |
| ICCD Insertion Delay | ≥19 ns |
| ICCD Photocathode Repetition Rate | up to 500 kHz |
| ICCD Cooling | −40 °C (TE-cooled) |
| iStar sCMOS Resolution | 2560 × 2160 pixels |
| iStar sCMOS Full-Frame Rate | 50 fps |
| ROI Frame Rate (512×512) | 203 fps |
| USB Interface | USB 2.0 (iStar ICCD) / USB 3.0 (iStar sCMOS) |
| PIV Mode Minimum Inter-Frame Interval | 200 ns |
| Intelligate™ UV/VUV Gating Extinction Ratio | ≥10⁸:1 |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | Medical Endoscopic Raman Spectroscopy System |
| Pricing | Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (PRC) |
| Model | MegaLED-Fluo |
| Pricing | Available Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Model | Omni-iSpecT Fiber-Coupled Raman Spectroscopy System |
| Laser Options | 532 nm (100 mW), 785 nm (350 mW) |
| Raman Shift Range | 200–4000 cm⁻¹ (532 nm) |
| Spectral Resolution | <10 cm⁻¹ (typical, @50 µm slit) |
| CCD Detector | Back-illuminated deep-depletion CCD, 2000 × 256 pixels, 15 µm pixel size, -60 °C cooling, read noise <5 e⁻/pixel |
| Probe Working Distance | 3 mm / 7 mm (standard), customizable |
| Operating Temperature | 0–325 °C (customizable up to 400 °C) |
| Max Pressure Rating | 6000 psi |
| Probe Material | Hard-anodized aluminum + 316 stainless steel |
| Sealing | Perfluoroelastomer (FFKM) O-rings standard |
| Fiber Core | 100/100 µm (standard), SMA/MPO/10 mm cylindrical interface |
| Optical Throughput | F/1.8 (532 nm), F/2.3 (785 nm) |
| Grating | 1800 l/mm VPH (532 nm), 1200 l/mm VPH (785 nm) |
| Weight | 5.0 kg (spectrometer), 5.8 kg (full system) |
| Brand | ZOLIX |
|---|---|
| Model | OmniPL-LF325 |
| Excitation Source | HeCd Laser (325 nm, 20 mW) |
| Rayleigh Cutoff Filter | OD > 6 |
| Spectral Range | 300–850 nm (extendable to 2500 nm) |
| Spectral Resolution | < 0.2 nm (@1200 g/mm grating) |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ±0.1 nm |
| Detector | Scientific-Grade Cooled Back-Illuminated CCD (300–1000 nm) |
| Cryogenic Compatibility | Optional Closed-Cycle Cryostat (down to 2 K) |
| Software | Customizable Acquisition Protocol, Spectral Arithmetic, Batch Processing, and GLP-Compliant Data Archiving |
| Brand | ZOLIX |
|---|---|
| Model | OmniPL-MicroS |
| Origin | Beijing, China |
| Manufacturer | ZOLIX Optics Co., Ltd. |
| Type | Integrated Micro-PL Spectrometer |
| Spectral Range | 200–1600 nm |
| Excitation Wavelengths (Optional) | 325, 405, 442, 473, 532, 633, 785 nm |
| Mapping Area | 50 mm × 50 mm (customizable) |
| Cryogenic Compatibility | Down to 10 K (with optional cryostat) |
| Software Features | Emission Spectrum Correction, Auto-Mapping, EL & Raman Expansion Modules |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | PMEye-3000 |
| Pricing | Upon Request |
| Brand | ZOLIX |
|---|---|
| Model | PMEye-3000 Series |
| Origin | Beijing, China |
| Manufacturer | ZOLIX (Producer) |
| Laser Options | 266 nm, 405 nm, 442 nm, 532 nm, 785 nm (internal) |
| Mapping Speed | >20 points/sec |
| Spatial Resolution | 10 µm (objective mode), 50 µm (lens mode) |
| Spectral Resolution | 0.1 nm @ 1200 grooves/mm |
| Max Sample Size | 8-inch wafer |
| Spectrometer | 500 mm focal length, triple-grating DSP-scanning monochromator |
| Detector Options | Si photodiode (200–1100 nm), R1527 PMT (200–680 nm), CR131 PMT (200–900 nm), DSi300 Si detector (200–1100 nm), DInGaAs1700 RT InGaAs (800–1700 nm), DInGaAs1900 cooled InGaAs (800–1900 nm), DInGaAs2200 cooled InGaAs (800–2200 nm), DInGaAs2600 cooled InGaAs (800–2600 nm) |
| Wavelength Accuracy | ±0.2 nm (@ 300 nm, 1200 g/mm), ±0.6 nm (@ 500 nm, 600 g/mm), ±0.8 nm (@ 1250 nm, 300 g/mm) |
| XY Stage | 200 × 200 mm travel, <3 µm repeatability |
| Minimum Step Size | 1 µm |
| Data Acquisition | DCS300PA digitizer with preamplifier |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Remote Raman System |
| Pricing | Upon Request |
| Excitation Wavelengths | 405, 514, 532, 633, 670, 671, 785, 808 nm |
| Spectral Range | 100–4000 cm⁻¹ (laser-dependent) |
| Focal Length Options | 20–100 mm (probe), 1000 mm (telescope) |
| Spot Size | ~100 µm @ 100 µm core fiber |
| Working Distance | 20–100 mm (probe) |
| Numerical Aperture | 0.22 @ 40 mm focal length |
| Probe Dimensions | 2.25" L × 0.96" W × 0.58" H |
| Probe Housing Material | Hard-anodized aluminum or 316 stainless steel |
| Telescope Interface | FC/APC (laser), SMA (spectrometer) |
| Spectrometer Types | Czerny-Turner imaging-corrected (320 mm focal length, F/4.2) or VPH grating-based (85 mm focal length, F/1.8) |
| Spectral Resolution | <2 cm⁻¹ @ 1800 l/mm (CT), ~5 cm⁻¹ @ 1800 l/mm (VPH) |
| Detector Options | ICCD (1024×1024, 13 µm pixels, <2 ns gate width, 280–810 nm) or back-illuminated deep-depletion CCD (2000×256, 15 µm pixels, 200–1100 nm) |
| Laser Options | Pulsed Nd:YAG (532 nm, 290 mJ, 10 Hz) or CW diode (532/785 nm, 100 mW) |
| Optical Density of Notch Filters | OD >6 |
| Operating Temperature | 0–85 °C |
| Max Pressure Rating | 15 psi |
| Fiber Core | 100/100 µm standard (FC or SMA interface) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic (China) |
| Model | Spectral Angular Distribution System |
| Wavelength Range | 200 nm – IR |
| Angular Positioning Repeatability | ±0.005° |
| Angular Resolution | 0.00125° |
| Optional Functionality | Diffraction Efficiency Measurement of Gratings |
| Brand | ZOLIX |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Ultrafast Spectroscopy Test System |
| Pricing | Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Type | Domestic |
| Model | Ultrafast Time-Resolved Spectroscopy System |
| Pricing | Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Ultrafast Time-Resolved Spectroscopy System |
| Pricing | Upon Request |
| Spectral Range | 200–900 nm (UV-VIS-NIR) |
| Temporal Resolution | ≤5 ps |
| Lifetime Measurement Range | 50 ps – 100 µs |
| Spectral Resolution | <0.1 nm |
| Single-Shot Spectral Coverage | ≥200 nm |
| Operation Modes | Steady-State Spectra, Transient Absorption Imaging, Time-Resolved Fluorescence Decay, Striped Streak Camera-Based Detection |
| Core Components | Imaging Spectrograph, Streak Camera Detector, Precision Coupling Optics, Integrated Control & Data Processing Software |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | X-Ray Bent-Crystal Spectrometer |
| Pricing | Available Upon Request |
| Brand | ZOLIX |
|---|---|
| Model | ZL-xx |
| Origin | Beijing, China |
| Manufacturer | ZOLIX Optics Co., Ltd. |
| Spectral Range | 200–2200 nm |
| Transmittance Range | τ(λ) = 0.1–0.9 |
| Uncertainty (Vis/UVA/UVB) | U < 0.015 |
| Uncertainty (UVC/NIR) | U < 0.02 |
| Repeatability | R < 0.01 |
| Accuracy | ±2% (for optical transmittance >10%) |
| Light Sources | Automatically switched deuterium lamp and tungsten-halogen lamp |
| Sample Positioning | ±150 mm in Z/Y axes, ±90° rotation about θz, ±45° rotation about θy |
| Software | Integrated spectral acquisition, filter wheel control, transmittance calculation, parameter auto-save, and direct print export |
| Brand | ZOLIX |
|---|---|
| Model | ZLX-RS-532 |
| Excitation Wavelength | 532 nm DPSS Laser |
| Output Power | ≥50 mW |
| Spectrometer Focal Length | 300 mm |
| f/# | f/3.9 |
| Grating | 1200 g/mm, Blaze @ 500 nm |
| Slit Width Range | 0.01–3 mm (0.01 mm resolution) |
| Spectral Range | 200–900 nm |
| Spectral Resolution | <0.1 nm (@ 435.83 nm) |
| Wavelength Accuracy | ≤ ±0.2 nm |
| Wavelength Repeatability | ≤ 0.1 nm |
| Stray Light | ≤ 10⁻⁴ |
| Linear Dispersion | 2.7 nm/mm |
| SNR | >12,000:1 (water Raman peak, 532 nm excitation, 1 s integration) |
| Detector | High-sensitivity PMT with photon counting electronics |
| Interface | USB 2.0 |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | ZW |
| Pricing | Upon Request |