Other Spectroscopy Instruments
Filter
Showing 31–60 of 138 results
| Brand | Ekspla |
|---|---|
| Origin | Lithuania (EU) |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | SFG PS |
| Price | Upon Request |
| Spectral Range | 625–4300 cm⁻¹ |
| Spectral Resolution | <6 cm⁻¹ (optional <2 cm⁻¹) |
| Pulse Duration | 29 ± 5 ps |
| Repetition Rate | 50 Hz |
| IR Tuning Range | 2.3–10 µm (optionally up to 16 µm) |
| VIS Wavelength | 532 nm (optional 1064 nm or tunable 420–680 nm) |
| Beam Geometry | Co-propagating, non-collinear (optional collinear) |
| Incidence Angles | Fixed (~60° VIS, ~55° IR |
| Polarization Control | Motorized s/p selection for IR, VIS, and SFG (purity > 1:100) |
| Detection | Time-gated photomultiplier tube (PMT) |
| Laser Source | Diode-pumped mode-locked Nd:YAG (PL2231 series) |
| OPG System | PG501-DFG (standard) or PG511-DFG (high-resolution) |
| Sample Compartment | Vertically oriented, customizable, compatible with Langmuir-Blodgett troughs, temperature/humidity cells, and in situ reaction chambers |
| Brand | Ekspla |
|---|---|
| Origin | Lithuania |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | SFG |
| Price | Upon Request |
| IR Tuning Range | 2.3–10 µm (4300–1000 cm⁻¹) |
| Spectral Resolution | < 6 cm⁻¹ |
| Detection Sensitivity | ~10 photons/shot |
| Acquisition Rate | 10 Hz |
| VIS Beam | 532 nm, < 2 cm⁻¹ linewidth, ~1 mJ pulse energy, 20–30 ps pulse duration, linear polarization (>100:1 extinction ratio) |
| IR Beam | 2.3–10 µm tuning, < 6 cm⁻¹ linewidth, linear polarization (>100:1), 20–200 µJ pulse energy |
| SFG Output Wavelength | 432–505 nm (with 532 nm VIS pump) |
| Optional Extension | Up to 16 µm (625 cm⁻¹) IR coverage |
| Brand | Ekspla |
|---|---|
| Origin | Lithuania |
| Model | T-SPEC |
| Spectral Bandwidth | up to 4.5 THz |
| Dynamic Range | >70 dB at 0.4 THz |
| Acquisition Rate | up to 10 spectra/sec |
| Spectral Resolution | down to 2.5 GHz |
| Delay Line | Bearing-Free Optical Delay Stage |
| Operation Modes | Transmission & Reflection |
| Imaging Capability | High-Spatial-Resolution THz Imaging |
| Control | Fully Computer-Controlled via Dedicated Software |
| Key | Brand: Ekspla |
|---|---|
| Origin | Imported (Lithuania) |
| Model | Ekspla-THz |
| Spectral Range | 0.1–3 THz |
| Temporal Resolution | <1 ps |
| Emitter Substrate | Low-Temperature-Grown GaAs (LT-GaAs) |
| Integrated Optics | Hyper-spherical high-resistivity silicon lens |
| Pump Laser Requirement | <150 fs pulses, 800 nm central wavelength |
| Detection Bandwidth (FWHM) | >700 GHz |
| Typical Output Power | >10 µW (with 100 mW Ti:Sapphire laser) |
| Compliance | Designed for ASTM E2964-compliant THz-TDS configurations |
| Software Interface | Compatible with LabVIEW, MATLAB, and Python-based acquisition frameworks |
| Brand | Ekspla |
|---|---|
| Origin | Imported (Lithuania) |
| Model | THz-1000 |
| Wavelength Compatibility | 1030 nm and shorter (optimized for 1000 nm pump) |
| Emitter Material | Low-Temperature-Grown GaBiAs |
| Detector Material | GaBiAs Epitaxial Layer |
| Spectral Range | 0.2–5 THz |
| Emitter Antenna | Coplanar Hertzian dipole, 70 µm arm width, 20 µm photosensitive gap |
| Detector Electron Mobility | ~5000 cm²/V·s |
| Detector Carrier Lifetime | < 0.5 ps |
| Integrated Optics | Hemispherical high-resistivity silicon lens (Ø15 mm) |
| Bias Voltage Range (Emitter) | Adjustable DC bias (typ. 0–30 V) |
| THz Power Conversion Efficiency | 7×10⁻⁴ |
| Detector Mounting | In-plane micro-positioning optomechanical holder with SMA RF output |
| Compliance | Designed for ultrafast laser-driven THz time-domain spectroscopy (TDS) systems |
| Brand | Ekspla |
|---|---|
| Origin | Imported (Lithuania) |
| Model | THz-TDS |
| Pump Laser | Mode-locked Ti:Sapphire, 760–840 nm, >60 mW avg. power, pulse width <50 fs (optional 20 fs), rep rate 50–100 MHz |
| THz Bandwidth | 0.1–3 THz (3.3–100 cm⁻¹) |
| Spectral Resolution | >15 GHz (corresponding to >70 ps time-domain scan window) |
| Dynamic Range | >1000:1 (electric field amplitude at 0.6 THz) |
| THz Emitter & Detector | LT-GaAs photoconductive antennas with integrated hyperhemispherical Si lenses, mounted on precision X-Y stages |
| Delay Line | Motorized optical delay line, max. scan range 300 ps (extendable) |
| Detection | Lock-in amplified electro-optic or photoconductive sampling |
| Polarization | Linear, configurable for horizontal/vertical THz polarization |
| Incidence Angle for Reflection | Adjustable 30°–50° |
| Imaging Resolution | ~1 mm (raster-scanned 2D transmission/reflection mapping) |
| Software | Real-time acquisition, FFT-based spectral extraction, transmission/reflection coefficient calculation, raw data export (.txt, .mat), source code available for customization |
| Compliance | Designed for GLP-compliant lab environments |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | FASP-05B |
| Price | Upon Request |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Flex-CLUE |
| Pricing | Available Upon Request |
| Brand | Fluxim |
|---|---|
| Origin | Switzerland |
| Model | OLED/PeLED |
| Angular Range | −90° to +90° |
| Spectral Range | 360–1100 nm |
| Spectral Resolution | 2.5 nm |
| Signal-to-Noise Ratio | 300:1 |
| Voltage Range | ±20 V |
| Current Range | ±120 mA |
| Current Resolution | <100 pA |
| Polarizer Rotation | 0–360° (continuous) |
| Sample Stage | 40 × 40 mm² |
| PL Excitation Wavelength | 275–405 nm (default 365 nm) |
| PL Spot Size | 5 × 3 mm² |
| Dimensions | 50 × 29 × 24 cm³ |
| Weight | 18 kg |
| Brand | Fluxim |
|---|---|
| Origin | Switzerland |
| Model | PHELOS |
| Angular Range | –90° to +90° |
| Spectral Range | 360–1100 nm |
| Spectral Resolution | 2.5 nm |
| Angular Resolution | < 0.5° |
| SNR | 300:1 |
| Voltage Range | ±20 V |
| Current Range | ±120 mA |
| Current Resolution | < 100 pA |
| Polarizer Rotation | 0–360° (continuous) |
| Sample Stage | 40 × 40 mm² |
| PL Excitation Wavelength | 275–405 nm (default 365 nm) |
| PL Spot Size | 5 × 3 mm² |
| Dimensions | 50 × 29 × 24 cm³ |
| Weight | 18 kg |
| Brand | FPI |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | SupNIR-1200 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | SupNIR-1500 |
| Pricing | Available Upon Request |
| Brand | GKINST |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Customizable |
| Pricing | Available Upon Request |
| Absorption Wavelength Range | 200–1100 nm |
| Emission Wavelength Range | 350–1100 nm |
| Excitation Laser Wavelength | 350–800 nm |
| Spatial Spot Size | 10 µm – 1 mm (continuously adjustable) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HandySpec |
| Pricing | Available Upon Request |
| Brand | McScience |
|---|---|
| Origin | South Korea |
| Model | HEXA 70 |
| Type | Portable Dual-Mode (Tristimulus & Spectral) Colorimeter |
| Communication | Bluetooth 5.0 & USB-C |
| Interface Compatibility | Windows 10/11, Android 8.0+, SCPI-compliant test instrumentation |
| Compliance | ISO/CIE 15:2018, CIE 179:2015, ASTM E308-22 |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Manufacturer |
| Import Status | Imported |
| Model | HCLUE |
| Pricing | Upon Request |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | HCLUE |
| Spectral Range (with dual detectors) | 185–2500 nm |
| Coupling Method | Mirror-based direct coupling |
| Detector Configuration | Dual-detector compatible |
| Spectrometer Focal Length Options | 320 mm, 500 mm, 550 mm |
| Grating Options | Multiple selectable gratings |
| Measurement Modes | Point spectrum, line scan, hyperspectral mapping |
| Compliance | Designed for integration with SEM/FIB platforms per ISO 16700 (electron probe microanalysis) and ASTM E1508 (quantitative cathodoluminescence) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | Flex-CLUE |
| Spectral Range | 200–1000 nm or 400–1700 nm |
| Optical Coupling | Fiber-coupled |
| Spectrometer Focal Length Options | 140 mm, 200 mm, 320 mm |
| Grating Options | Multiple selectable |
| Measurement Modes | Point acquisition, line scan, hyperspectral mapping |
| Detector Compatibility | Open-electrode CCD, EMCCD, InGaAs arrays |
| Integration | SEM-compatible (FE-SEM, SEM, STEM) |
| Spatial Resolution | Sub-100 nm (dependent on electron beam conditions and sample properties) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | LEM |
| Pricing | Available Upon Request |
| Brand | IdeaOptics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | TEMBO-300 |
| Pricing | Available Upon Request |
| Brand | Princeton Instruments (Teledyne) |
|---|---|
| Origin | USA |
| Model | IsoPlane SCT-320, IsoPlane 160 |
| Focal Length | 320 mm (SCT-320), 203 mm (160) |
| Aperture Ratio | f/4.6 (SCT-320), f/3.88 (160) |
| Spectral Resolution (PMT) | 0.05 nm (SCT-320), 0.10 nm (160) |
| Spectral Resolution (CCD, 1200 gr/mm, 435 nm, 20 µm pixels, 10 µm slit) | 0.08 nm (SCT-320), 0.15 nm (160) |
| Grating Mount | Motorized triple-grating turret with auto-recognition |
| Wavelength Range | UV to mid-IR (193 nm–>5 µm, depending on grating & detector) |
| Optical Coating Options | Acton #1900 enhanced Al (193 nm–mid-IR), protected Ag (>98% avg. reflectance), Au (NIR/SWIR) |
| Detector Compatibility | PIXIS, ProEM, PI-MAX4, NIRvana series |
| Software Platform | LightField v8+ (64-bit), supports LabVIEW, MATLAB, EPICS, and FDA 21 CFR Part 11-compliant audit trail modules |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FI/IR NRS |
| Price | Upon Request |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VAP-8010 |
| Pricing | Available Upon Request |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | Brewer MkIII |
| Wavelength Range | 286.5–363 nm |
| Spectral Resolution | 0.6 nm |
| Wavelength Stability | ±0.01 nm (over full operating temperature range) |
| Detector | Photomultiplier Tube (PMT) |
| Optical Design | Dual Monochromator |
| Power Supply | 230 VAC or 115 VAC |
| Operating Temperature | −20 °C to +50 °C (−50 °C to +50 °C with optional cold-weather housing) |
| Measured Parameters | Total Ozone Column, SO₂ Column, Spectral UV Irradiance (UVA, UVB, UVE), UV Index (UVI) |
| Brand | Sichuan Xinxianda |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | L Boundary Density Meter |
| Pricing | Upon Request |
| Brand | LI-COR |
|---|---|
| Origin | USA |
| Model | LI-180 |
| Spectral Range | 380–780 nm |
| Wavelength Resolution | 1 nm (FWHM ≈ 12 nm) |
| Measurement Parameters | PPFD (1–3,000 µmol·m⁻²·s⁻¹), Irradiance (0.5–1,000 W·m⁻²), Illuminance (70–150,000 lx) |
| Detector | CMOS linear image sensor with cosine-corrected optical input |
| Display | 3.5″ 320×420 touchscreen LCD |
| Data Storage | 8 GB SD card (up to 68,000 files) |
| Battery Life | 5 h continuous operation (2500 mAh Li-ion) |
| Accuracy | PPFD ±5%, Illuminance ±5%, Chromaticity (x,y) ±0.0025, CCT ±2%, CRI (Ra) ±1.5% |
| Compliance | JIS C 1609-1:2006 Class AA, DIN 5032-7 Class B |
| Interface | Mini USB 2.0, Wi-Fi SD card, microSD (up to 32 GB) |
| Output Formats | .txt, .jpg |
| Operating Temperature | 0–35 °C |
| Dimensions | 200 × 77 × 26 mm |
| Weight | 0.28 kg |
| Brand | Fluxim |
|---|---|
| Origin | Switzerland |
| Model | LITOS |
| Channel Capacity | 16–32 parallel channels |
| Environmental Chambers | 4 independent, sealed chambers with individual temperature/humidity/light control |
| Temperature Range | 0–125 °C |
| Voltage Range | −10 V to +10 V |
| Current Range | ±20 mA per channel |
| Sample Size Support | up to 2-inch substrates |
| Compliance | ISOS protocols (ISOS-L-1, ISOS-L-2, ISOS-O-1, ISOS-D-1) |
| Optional In Situ Spectroscopy | UV-VIS absorption (PV mode) or electroluminescence (OLED mode) |
| Integrated PAIOS Transient Platform Support | J-V, CELIV, DLTS, TPV, TPC, TEL, IMPS/IMVS, IS/CV |
| Automation | Full script-driven operation with timestamped data logging and real-time curve generation |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model | Acton LS 785 |
| Focal Length | 85 mm |
| Aperture Ratio | f/2.0 |
| Spectral Resolution | 5 cm⁻¹ (with 25 µm fiber) |
| Linear Dispersion | 6.13 nm/mm @ 900 nm |
| Grating | 1200 g/mm, gold-coated |
| Wavelength Range | 750–1100 nm (tunable via micrometer-driven grating stage) |
| Optical Design | Prism-based, AR-coated fused silica prism + optimized f/2 imaging optics |
| Detector Compatibility | Fully compatible with Teledyne Princeton Instruments PIXIS and PyLoN deep-depletion CCD cameras |
| Brand | Ocean Optics |
|---|---|
| Model | FD-LTMS |
| Wavelength Range | 400–700 nm |
| Detector | 1024-element linear array |
| Optical Design | Asymmetric crossed Czerny-Turner spectrometer |
| Spectral Sampling Interval | 10 nm |
| FWHM | 6 nm |
| Light Source | Pulsed LED (>250 million measurements lifetime) |
| Sample Holders | 10 mm pathlength cuvette & flow-cell interface |
| Connectivity | USB 2.0 |
| OS Compatibility | Windows 7+, 64-bit |
| Enclosure Rating | IP67 |
| Origin | Shanghai, China |
| Manufacturer | Ocean Optics (Shanghai) |
| Brand | McPherson |
|---|---|
| Origin | USA |
| Model | 234/302 |
| Optical Configuration | Seya-Namioka (S-N) |
| Wavelength Range | 30–2200 nm |
| Resolution | 0.1 nm |
| Focal Length | 2000 mm |