Other Spectroscopy Instruments
Filter
Showing 91–120 of 138 results
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | xSORT |
| Type | Handheld ED-XRF Spectrometer |
| Safety Compliance | CE, IEC 62471, EN 61000-6-3/6-4 |
| Regulatory Conformance | RoHS/WEEE Compliant, ASTM E2857, ISO 21043, USP <232>/<233> for Elemental Impurities |
| Detection Range | Mg (12) to U (92) |
| Light Element Capability | Mg, Al, Si, P analyzed in air |
| Typical Analysis Time | 2–60 s |
| Sample Form | Solids, powders, soils, sludges, filters, thin films, alloys, ores |
| Calibration | Built-in ICAL self-calibration reference |
| Data Storage | Onboard memory with timestamp, GPS coordinates, and CCD image capture |
| Software | SPECTRO XRF Analyzer Suite (supports GLP/GMP audit trails, 21 CFR Part 11 optional modules) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 785 Raman Spectrometer |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | HyperChannel Hyperspectral Imaging Spectrometer |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | LIBS-1000 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | MultiChannel Multichannel Spectrometer |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | Raman Spectrometer |
| Pricing | Available Upon Request |
| Brand | SRS/Stanford Research Systems |
|---|---|
| Origin | USA |
| Model | RGA100 |
| Mass Range | 1–100 amu |
| Resolution | <1 amu |
| Dynamic Range | 6 decades |
| Detection Limit | 5×10⁻¹⁴ Torr |
| Interface | RS-232 |
| Software | RGA Windows & LabVIEW |
| Replaceable Components | Field-replaceable electron multiplier and filament |
| Compliance | Designed for UHV and HV vacuum environments per ASTM E1981 and ISO 14523-2 |
| Brand | StellarNet |
|---|---|
| Origin | USA |
| Model | StellarCASE-NIR |
| Optical Configuration | Reflectance & Transmission (Fiber-Coupled) |
| Spectral Range | 900–1700 nm |
| Spectral Resolution | ~3–5 nm (FWHM) |
| Detector | InGaAs Linear Array |
| Integration Time | 1 ms – 10 s |
| Interface | USB 2.0 |
| Power | Internal Rechargeable Li-ion Battery (8 h typical) |
| Dimensions | 185 × 120 × 65 mm |
| Weight | 1.2 kg |
| Calibration Support | Factory NIST-Traceable Wavelength & Radiometric Calibration |
| Software Compatibility | Windows 10/11, StellarNet SpectraWiz® Suite v8.5+ |
| Data Export | CSV, TXT, XML, ASTM E131-compliant format |
| Key Specifications | Origin: USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | SWIR Short-Wave Infrared Spectrometer |
| Pricing | Upon Technical Consultation |
| Brand | Ekspla |
|---|---|
| Origin | Lithuania |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | T-FIBER |
| Pricing | Upon Request |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model | HRS-300, HRS-500 |
| Focal Length | 300 mm (HRS-300), 500 mm (HRS-500) |
| f-number | f/3.9 (HRS-300), f/6.5 (HRS-500) |
| Linear Dispersion | 2.38 nm/mm (HRS-300), 1.52 nm/mm (HRS-500) |
| PMT Resolution (1200 g/mm grating, 435.8 nm, 10 µm slit) | 0.09 nm (HRS-300), 0.05 nm (HRS-500) |
| CCD Resolution (1200 g/mm grating, 435.8 nm, 20 µm pixel & slit) | 0.10 nm (HRS-300), 0.07 nm (HRS-500) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | ARL 3460 |
| Condition | Refurbished & Fully Qualified |
| Compliance | Meets ASTM E1184, ISO 11577, and EN 10052 for metallic alloy analysis |
| Software | ARL SpectraGraph v8.x (with full calibration history and audit trail) |
| Detector Type | Photomultiplier Tube (PMT) array |
| Excitation Source | High-energy spark discharge (400–1000 V, adjustable frequency) |
| Typical Analysis Time | 20–45 s per sample |
| Wavelength Range | 120–800 nm |
| Resolution | ≤ 0.01 nm at 200 nm |
| Sample Form | Solid metal discs or pins (Ø 25–40 mm, thickness ≥ 5 mm) |
| Gas Requirement | Argon purge (99.995% purity, flow rate 3–5 L/min) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-manufactured) |
| Model | Nicolet Apex FTIR Spectrometer |
| Pricing | Request Quote |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestically Manufactured |
| Model | Nicolet Summit X FTIR Spectrometer (Domestically Manufactured) |
| Pricing | Available Upon Request |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | TR-PLIF |
| Laser Repetition Rate | ≥1 kHz |
| Excitation Source | Frequency-Doubled Nd:YAG (532 nm), Pumped by High-Repetition-Rate YAG Laser |
| Detection | Intensified CCD or sCMOS Camera with Sub-Microsecond Gating |
| Temporal Resolution | <100 ns (adjustable via optical delay and camera gating) |
| Spatial Resolution | ≤50 µm (system-limited, dependent on optics and pixel binning) |
| Spectral Bandwidth | Tunable via narrowband interference filters (FWHM ≈ 1–5 nm) |
| Compliance | CE Marked, RoHS Compliant |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | DMA-500 |
| Sample Introduction | Solid, Liquid, Gas (Direct Analysis, No Digestion Required) |
| Detection Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) with Thermal Release and Dual-Absorption-Cell Optical Path |
| Automation | 4-Axis Robotic Autosampler (100-position) |
| Temperature Control | PID-Controlled Ashing & Catalytic Combustion Furnaces |
| Mercury Trap | Constant-Power Heated Trap (Rapid Thermal Response, Zero Memory Effect) |
| Optical System | Dual-Beam Light Source with Real-Time Drift Compensation |
| Compliance | Designed for ISO 17025-accredited laboratories |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | TPZG-6H |
| Spectral Range | 350–800 nm |
| CCD Sensor Type | High-Precision Linear CCD |
| Spectral Bandwidth (FWHM) | 2 nm |
| Spectral Resolution / Repeatability | 0.2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Illuminance Accuracy | Class I (±4% of reading ±1 digit) |
| Chromaticity Coordinate Accuracy | ±0.0025 (traceable to NIM-standard stable source, drift <±0.0005) |
| Correlated Color Temperature (CCT) Range | 1,000 K – 100,000 K |
| Stray Light | ≤0.3% |
| Illuminance Measurement Range | 5 lx – 200 klx |
| Integration Time | 50 µs – 10,000 ms |
| Display | 5.0-inch HD capacitive touchscreen |
| Data Export | Micro USB interface |
| Storage | Pre-installed 8 GB microSD card |
| Power | Rechargeable Li-ion battery |
| Operating Temp./RH | −10 °C to +40 °C, <70% RH (non-condensing) |
| Storage Temp./RH | −20 °C to +45 °C, <70% RH (non-condensing) |
| Dimensions / Weight | 138.5 × 81 × 23 mm / ~430 g (with battery, no accessories) |
| Brand | TTI |
|---|---|
| Origin | USA |
| Model | FTE-7000 |
| Wavelengths | 850, 1300, 1310, 1550 nm ±20 nm |
| Dynamic Range | 27/26 dB (MM), 32/30 dB (SM) |
| Event Dead Zone | 2 m |
| Attenuation Dead Zone | 5 m |
| Distance Range | 1–64 km (MM), 1–240 km (SM) |
| Pulse Width | 20–10,000 ns |
| Resolution | 0.25–64 m |
| Distance Uncertainty | ±(0.75 m + 0.005% × distance + sampling resolution) |
| Sampling Rate | 4 Hz typical real-time refresh |
| Refractive Index Range | 1.024–2.048 |
| Linearity | ±0.05 dB/dB |
| Onboard Storage | 1,000 traces |
| Battery Life | 4 hours |
| Operating Temperature | −10 to 50 °C |
| Storage Temperature | −20 to 60 °C |
| Dimensions (L×W×H) | 194 × 99 × 40 mm |
| Weight | 0.73 kg |
| Interface | USB |
| Connector Types | Interchangeable FC/ST/SC |
| Included Software | Windows-based Telcordia SR-4731 compliant OTDR analysis suite |
| Brand | TTI |
|---|---|
| Origin | USA |
| Model | FTE-8000 |
| Wavelength Range | FTE-8000S: 1492–1528 nm (200.9–196.2 THz) |
| FTE-8000C | 1530–1561 nm (196.0–192.0 THz) |
| FTE-8000L | 1572–1608 nm (190.5–186.3 THz) |
| FTE-8000CWDM | 1271–1611 nm |
| Wavelength Accuracy | ±0.1 nm |
| Channel Spacing | 50 GHz, 100 GHz, or 20 nm (CWDM) |
| Power Range | +10 dBm to –50 dBm |
| Absolute Power Accuracy | ±1 dB |
| Resolution | 0.01 dB |
| Polarization-Dependent Loss (PDL) | ±0.15 dB |
| Optical Attenuation Ratio | 40 dBc (@50 GHz) |
| Sweep Time | <0.5 s |
| Return Loss | >40 dB |
| Optical Connector | Universal UPC (FC/SC compatible) |
| Display | 4-inch TFT color LCD |
| Dimensions | 19.7 × 11.45 × 5.6 cm |
| Weight | 0.91 kg |
| Battery | Rechargeable NiMH, 8-hour runtime |
| Operating Temperature | –10 °C to +50 °C |
| Storage Capacity | 1000 test records |
| Interface | USB host/device (for PC and USB flash drive) |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HVG-A |
| Pricing | Upon Request |
| Brand | Yokogawa |
|---|---|
| Model | AQ6370D |
| Wavelength Range | 600–1700 nm |
| Wavelength Accuracy | ±0.01 nm |
| Wavelength Resolution | 0.02 nm |
| Dynamic Range | 78 dB (typ.) |
| Power Range | +20 to −90 dBm |
| Sweep Time | 0.2 s (for 100 nm span) |
| Fiber Compatibility | Single-mode and multimode fiber |
| Origin | Japan (manufactured in Yokogawa facilities |
| Brand | ZHUOLIHANG |
|---|---|
| Origin | Shanghai, China |
| Model | XS11639-350-1050-25 |
| Detector | Hamamatsu S11639 InGaAs-enhanced CCD linear array |
| Spectral Range | 350–1050 nm |
| Pixels | 2048 |
| Slit Width | 25 µm |
| Optical Resolution | ~1.5 nm (FWHM @ 200 µm fiber) |
| Wavelength Accuracy | < ±0.5 nm |
| SNR | 300:1 (full signal, 100 ms integration) |
| Dark Noise | 50 RMS counts (100 ms) |
| Dynamic Range | 1300:1 (@ 100 ms) |
| A/D Resolution | 16-bit |
| Integration Time | 1 ms – 65 s |
| Interface | USB-Micro |
| Dimensions | 75 × 63.5 × 31.5 mm |
| Weight | 185 g |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | Chame-3000 |
| Pricing | Upon Request |
| Spectral Range | 380–780 nm |
| Measurement Speed (Optical) | 30 ms |
| Measurement Speed (Electrical) | 20–120 ms (model-dependent) |
| Voltage Range | 0–10.00 V |
| Current Range | 0–500 mA (SL series), up to ±1500 mA (SH series) |
| Luminous Intensity Sensitivity | 5 mcd – 30,000 mcd |
| Colorimetric Accuracy (x,y) | ±0.005 |
| Dominant Wavelength Accuracy | ±1 nm |
| IV Repeatability | ±2% |
| Spectral Resolution | 1 nm |
| Interface | USB 2.0 |
| Power Supply | USB 2.0 or DC 5 V |
| Dimensions | 140 × 80 × 180 mm |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | Chameleon-QY |
| Pricing | Upon Request |
| Excitation Source | 460 nm Blue LED |
| Detection System | SGM100 Spectrograph with TCD1304DG Linear CCD Array |
| Integration Sphere | 110 mm Diameter, >96% Reflectance (380–1400 nm) |
| Spectral Range | 400–780 nm |
| Spectral Resolution | 1.62 nm |
| Wavelength Accuracy | ±0.5 nm |
| Integration Time | 7.2 ms – 64 s |
| Optical Design | Asymmetric Crossed Czerny-Turner (C-T) |
| Focal Length | 100 mm |
| f-number | f/2.95 |
| Slit Width | 100 µm |
| Pixel Count | 3648 |
| Pixel Size | 8 µm × 200 µm |
| PRNU | ≤10% |
| Communication Interface | USB 2.0 |
| Power Supply | 5 VDC @ 350 mA (USB-powered or external adapter) |
| Spectrograph Dimensions | 203 × 160 × 90 mm |
| Spectrograph Weight | 4 kg |
| Integrating Sphere Dimensions | 130 × 130 × 165 mm |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Laser Wavelengths | 405/514/532/633/670/671/785/808 nm |
| Raman Shift Range | 100–4000 cm⁻¹ (laser-dependent) |
| Spectral Resolution | <10 cm⁻¹ (guaranteed) |
| Probe Working Distance | 3 mm / 7 mm (standard), customizable up to 18 mm |
| Operating Temperature | 0–325 °C (customizable) |
| Max Pressure Rating | 6000 psi |
| Probe Material | Hard-anodized aluminum & 316 stainless steel |
| Fiber Core/Clad | 100/100 µm (standard), custom options available |
| Detector | Back-illuminated deep-depletion CCD (2000 × 256 pixels, 15 µm pitch, -60 °C cooling, read noise <4.5 e⁻) |
| Optical Interface | SMA/MPO/10 mm cylindrical |
| Filter OD | >6 (long-pass, laser-line rejection) |
| System Weight | 5.0–5.8 kg |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Endoscopic Raman Spectroscopy System |
| Pricing | Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Gas Phase Raman Spectrometer |
| Pricing | Available Upon Request |
| Brand | ZOLIX |
|---|---|
| Model | Gas Raman Analyzer |
| Origin | Beijing, China |
| Manufacturer | ZOLIX Optics Co., Ltd. |
| Type | Raman Spectroscopy-Based Gas Analyzer |
| Laser Excitation | 532 nm (0–1.5 W, power stability <3% RMS) |
| Optical Architecture | High-throughput transmissive imaging spectrometer with deep-cooled high-sensitivity CCD/CMOS detector |
| Enhanced Optical Path | Optimized Raman collection geometry with gas cell integration |
| Detection Modes | Static gas cell, high-pressure folded-path cell, integrating sphere, photonic crystal fiber (PCF) gas cell |
| Compliance | Designed for GLP/GMP-aligned operation |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | GX |
| Pricing | Available Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Models | iKon-M SO |
| Pricing | Upon Request |