| Brand | McPherson |
|---|---|
| Origin | USA |
| Model | Model 218 |
| Focal Length | 300 mm |
| Optical Design | Crossed Czerny-Turner |
| Beam Angle (Input/Output) | 44° |
| f/# | f/5.3 |
| Grating Size | 50 × 50 mm |
| Wavelength Accuracy | ±0.10 nm (mechanical counter, 1200 grooves/mm grating) |
| Wavelength Repeatability | ±0.005 nm (1200 grooves/mm grating) |
| Focal Plane Width | up to 17 mm |
| Wavelength Range | configurable per grating selection (VUV to LWIR) |
| Brand | McPherson |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Model 234/302 |
| Pricing | Upon Request |
| Focal Length | 200 mm |
| Optical Design | Modified Seya-Namioka |
| f/# | 4.5 |
| Grating Size | 40 × 45 mm |
| Wavelength Accuracy | ±0.10 nm (with 1200 g/mm grating) |
| Wavelength Repeatability | ±0.05 nm (with 1200 g/mm grating) |
| Slit-to-Slit Working Distance | 229 mm |
| Input/Output Beam Angle | 64° or 180° selectable |
| Focal Plane Width | 25 mm |
| Focal Plane Tilt | ~30° |
| Grating Options | 300–2400 g/mm |
| Resolution @ 313.1 nm | 0.06–0.3 nm (dependent on grating) |
| Reciprocal Linear Dispersion | 2–816 nm/mm |
| Detector Interface | CCD or MCP imaging array |
| Vacuum Compatibility | Standard UHV option (10⁻¹⁰ Torr with all-metal seals) |
| Residual Gas Analysis | Performed pre-shipment |
| Brand | McScience |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | M20 |
| Pricing | Upon Request |
| Spectral Range | 380–780 nm |
| Spectral Resolution | 1 nm |
| Luminance Measurement Range (Illuminant A) | 0.1–100,000 cd/m² |
| Imaging Capability | Integrated CCD Camera |
| Optional Accessories | Close-up Lens, Neutral Density Filters |
| Interface Compatibility | Windows PC & Android Tablet |
| Compliance | Designed for display metrology per CIE S 026/E:2015, ISO 13406-2, and VESA DisplayHDR™ test protocols |
| Brand | Micheem / BEIJING MICHEM TECHNOLOGY LTD. |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | M4000 |
| Pricing | Upon Request |
| Origin | Imported |
|---|---|
| Manufacturer Type | Distributor |
| Model | NIR/MIR |
| Price | Upon Request |
| Wavelength Range (NIR) | 0.6–1.7 µm, 0.9–2.1 µm |
| Wavelength Range (MIR) | 2.5–5 µm, 5–10 µm |
| Spectral Resolution | <9 nm (NIR), <12 nm (NIR), <30 nm (MIR), <50 nm (MIR) |
| Wavelength Accuracy | <0.5 nm (NIR), <2 nm (MIR) |
| SNR | >7000:1 (NIR), >1000:1 (NIR), >500:1 (MIR), >500:1 (MIR) |
| Integration Time | 4 ms |
| Dimensions (NIR) | 107 × 66 × 80 mm |
| Dimensions (MIR) | 107 × 110 × 80 mm |
| Power Supply | 9–18 V DC (NIR), 18–36 V DC (MIR) |
| Interface | USB, RS-485 |
| Detector Cooling | Optional thermoelectric (TE) cooling |
| Input Coupling | Free-space or fiber-optic |
| Brand | REMEX (Xi’an Remex Analytical Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Model | MPI-F |
| Type | Flow Injection Chemiluminescence (FICL) Analyzer |
| Detection Principle | Photomultiplier Tube (PMT)-based chemiluminescence detection with integrated flow injection manifold and electrochemical compatibility |
| Compliance Framework | Designed for GLP-compliant laboratories |
| Software Interface | Windows-native USB communication protocol (USB 2.0 compliant), real-time data streaming to host PC |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | OPA-1000 |
| Pricing | Upon Request |
| Brand | NCS (China Iron and Steel Research Institute Group) |
|---|---|
| Model | OPA-500 |
| Optical System | Czerny-Turner spectrometer with 500 mm focal length |
| Grating | 2700 lines/mm |
| Linear dispersion | 0.7407 nm/mm |
| Spectral resolution | ≤0.01 nm |
| Wavelength range | 160–650 nm |
| Excitation source | High-stability continuous spark source, no pre-burn required |
| Data acquisition rate | 100 kHz |
| Scanning platform | Siemens CNC-controlled 3-axis system (X: 360 mm, Y: 247 mm, Z: 350 mm) |
| Positioning accuracy (bidirectional) | X-axis ±0.016/±0.010 mm, Y/Z-axis ±0.012/±0.010 mm |
| Repeatability (bidirectional) | ±0.008/±0.006 mm (X/Y/Z) |
| Maximum scan area | 300 × 200 mm |
| Sample weight capacity (uniform load) | 200 kg |
| Compressed air requirement | 0.6 MPa |
| Power supply | 220 VAC ±10%, 50 Hz |
| Dimensions (W×D×H) | 1929 × 1428 × 2016 mm |
| Scan patterns | Rectangular, circular, cross (“rice”), sector, and custom-defined contours |
| Data interface | Ethernet |
| Software compliance | Supports audit trail, user access control, and electronic signature per FDA 21 CFR Part 11 requirements |
| Brand | Neaspec |
|---|---|
| Origin | Germany |
| Configuration | Near-field infrared and terahertz pump-probe nanoscopy system with visible–NIR excitation and mid-IR/THz detection |
| Spatial Resolution | 20–50 nm |
| Temporal Resolution | down to 50 fs |
| Probe Spectral Ranges | 650–2200 cm⁻¹ (mid-IR) or 0.5–2 THz |
| Pump Laser Compatibility | tunable visible to near-infrared sources |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | SWS6211 |
| Spectral Range | 1250–2500 nm |
| Interface | USB 2.0 |
| Detector | Single-element InGaAs photodiode |
| Optical Coupling | Fiber-optic (SMA 905 connector) |
| Power Consumption | <1.5 W |
| Dimensions | 72 × 52 × 32 mm |
| Weight | <120 g |
| Compliance | CE, RoHS, FCC Class B |
| Brand | NLIR |
|---|---|
| Origin | Denmark |
| Model | S2050-400 / S2050-1k / S2050-130k |
| Spectral Range | 2.0–5.0 µm |
| Full-Spectrum Readout Rate | up to 130 kHz |
| Sensitivity | −80 dBm/nm |
| Resolution | down to 2.5 cm⁻¹ (2048-pixel detector array) |
| Input | fiber-coupled (SMF-28, FC/PC optional) |
| Software Interface | native GUI + MATLAB/Python/C (DLL) APIs |
| Compliance | compatible with GLP/GMP data integrity workflows via timestamped, audit-trail-enabled acquisition logs |
| Brand | NLIR |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | S76120 Prototype |
| Spectral Range | 7.6–12 µm |
| Resolution | 8–10 cm⁻¹ |
| Full-Spectrum Readout Rate | 50 Hz |
| Sensitivity (Full Aperture) | 200 pW/nm (−67 dBm/nm) |
| Exposure Time | 1–200 ms |
| Field of View (FWHM, full angle) | 2.1° |
| ADC Bit Depth | 14-bit |
| Dark Noise RMS (100 ms) | 7 counts |
| Minimum Detectable Power (100 ms) | 200 pW/nm |
| Input Interface | Free-Space Optical |
| Polarization Sensitivity | Vertical |
| Max Operating Temperature | 30 °C |
| Dimensions (H×L×W) | 100 × 306 × 200 mm³ |
| Weight | 5 kg |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | QE Pro High-Performance Spectrometer |
| Detector Type | Back-Thinned CCD |
| Optical Resolution (FWHM) | Configurable from 0.14 nm to 10 nm (dependent on grating and slit) |
| Wavelength Range | 200–1100 nm (model-dependent configurations) |
| Signal-to-Noise Ratio | Up to 80,000:1 (at full signal, 10 s integration) |
| Dynamic Range | >85,000:1 (with 15,000-spectrum onboard memory buffer) |
| Integration Time | 8 ms – 60 s |
| Thermoelectric Cooling | Down to –15 °C below ambient |
| Interface | USB 3.0 |
| Compliance | CE, RoHS, FDA 21 CFR Part 11 ready (via OceanView software configuration) |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | QE65 Pro Research-Grade Spectrometer |
| Detector | Hamamatsu S7031-1006 back-illuminated CCD |
| Quantum Efficiency | up to 90% |
| Cooling | TEC-controlled, down to −15 °C |
| Spectral Range (configurable) | 200–950 nm or 350–1100 nm |
| Slit Options | Interchangeable SMA905-mount slits |
| Stray Light Rejection | Enhanced via optimized grating and optical design |
| Signal-to-Noise Ratio | 1000:1 (full signal, 1 s integration) |
| Thermal Wavelength Stability | <0.005 nm/°C |
| Trigger Interface | TTL-compatible hardware trigger input/output |
| Brand | Other Brands |
|---|---|
| Origin | Domestic |
| Manufacturer Type | General Distributor |
| Origin Category | Imported |
| Model | PEM Photoelastic Modulator (Domestic) |
| Price | Upon Request |
| Brand | Picarro |
|---|---|
| Origin | USA |
| Model | G2301 |
| Measurement Principle | Cavity Ring-Down Spectroscopy (CRDS) |
| Simultaneous Target Gases | CO₂, CH₄, H₂O |
| Detection Sensitivity | <0.5 ppb (CH₄), <70 ppb (CO₂), <80 ppm (H₂O) |
| Precision (1σ, 5 s) | CO₂ <70 ppb, CH₄ <0.5 ppb, H₂O <80 ppm |
| Precision (1σ, 5 min) | CO₂ <25 ppb, CH₄ <0.22 ppb, H₂O <30 ppm |
| Max Drift (24 h, STP) | CO₂ <120 ppb, CH₄ <1 ppb, H₂O <100 ppm |
| Water Vapor Correction | Automatic dry-mole-fraction reporting |
| Operating Pressure Range | 300–1000 Torr (40–133 kPa) |
| Sample Flow Rate | <0.4 SLM at 760 Torr |
| Temperature Control Stability | ±0.005 °C (cavity) |
| Pressure Control Stability | ±0.0002 atm (cavity) |
| Sample Temp. Range | −10 to +45 °C |
| Ambient Temp. Range (operational) | 10 to 35 °C |
| Data Interfaces | RS-232, Ethernet, USB, analog (0–10 V optional) |
| Dimensions (Analyzer) | 43.2 × 17.8 × 44.5 cm (W×H×D) |
| Weight | 26.9 kg (incl. external pump) |
| Power | 100–240 VAC, 47–63 Hz, <375 W peak |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | PolyPen Aqua PA210 |
| Spectral Range (UVIS) | 380–790 nm |
| Spectral Range (NIR) | 640–1050 nm |
| Optical Resolution (FWHM) | 8 nm |
| Stray Light | −30 dB |
| Optical Aperture | 7 mm |
| Measurement Chamber Volume | 4 mL |
| Light Source | Pulsed Xenon Lamp |
| OD Wavelengths (UVIS) | 600, 680, 735, 750 nm |
| OD Wavelengths (NIR) | 680, 735, 750 nm |
| Display | 240 × 320 px TFT touchscreen (65,535 colors) |
| Onboard Memory | 16 MB (≥4,000 spectra) |
| ADC | 16-bit |
| Dynamic Range | 1:4,300 (high gain), 1:13,000 (low gain) |
| Scan Time | ~100 ms per spectrum |
| GPS Accuracy | <1.5 m (CE-certified module) |
| Dimensions | 150 × 75 × 40 mm |
| Weight | 300 g |
| Enclosure | IP54-rated splash-resistant housing |
| Battery | Rechargeable 2600 mAh Li-ion (USB charging) |
| Operating Time | Up to 48 h continuous measurement |
| Operating Temp. | 0–55 °C |
| Storage Temp. | −10–60 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Brand | Princeton Instruments (Teledyne) |
|---|---|
| Origin | USA |
| Sensor Type | Back-illuminated, fully depleted silicon CCD |
| Pixel Format | 1340 × 100 (HR/LD) or 1340 × 400 (HR/LD) |
| Pixel Size | 20 × 20 µm |
| QE | 75% @ 1000 nm (HR), optimized dark current < 0.0005 e⁻/pix/s (LD) |
| Readout Speed | Up to 32 MHz dual-ADC (HR), 16 MHz (LD) |
| Spectral Acquisition Rate | Up to 1650 spectra/s (continuous), 215 kHz (kinetics mode, HR only) |
| Cooling | ArcTec™ multi-stage thermoelectric cooling |
| Interface | USB 3.0 (5 Gb/s), optional fiber-optic USB extender (50 m) |
| Software | LightField 64-bit with PICAM SDK, IntelliCal wavelength & intensity calibration, LabVIEW/MATLAB/EPICS compatibility |
| Brand | Princeton Instruments / Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model | FER-SCI-BRX, FER-SCI-BX |
| Focal Length | 80.8 mm |
| Aperture | f/4 |
| Spectral Resolution (full focal plane) | 0.20–0.24 nm |
| Wavelength Range | UV-NIR (200–1100 nm) and VIS-NIR (400–1100 nm) |
| Grating Options | 295, 600, 1200 g/mm (interchangeable single-grating turret) |
| Slit Widths | 10–500 µm (laser-cut, height 3.3 mm) |
| CCD Type | Back-illuminated, deep-depletion, frame-transfer architecture with eXcelon and UV coating |
| Sensor Format | 1024 × 256 active + 1024 × 256 storage (total 1024 × 512) |
| Peak Quantum Efficiency | 95% |
| Cooling | Thermoelectric to −60 °C |
| Read Noise | 10 e⁻ rms @ 1 MHz |
| Integration Time | Up to 40 minutes (FER-SCI-BRX), several hours (FER-SCI-BX) |
| Spectral Acquisition Rate | 292 fps (FVB mode, FER-SCI-BRX), 124 fps (FVB mode, FER-SCI-BX) |
| Kinetic Mode Speed | >10,000 spectra/s (10-row binning, FER-SCI-BRX), >5,000 spectra/s (10-row binning, FER-SCI-BX) |
| Wavelength Accuracy | 0.26 nm |
| Repeatability | 0.13 nm |
| Spatial Resolution | 38.5 lp/mm @ 50% contrast (Nyquist-limited, full focal plane) |
| Line Transfer Speed | Adjustable 5.6–35 µs/line (FER-SCI-BRX), 15.2–95 µs/line (FER-SCI-BX) |
| Nonlinearity | <1% @ 1 MHz |
| Gain Options | 1.5 or 3 e⁻/ADU |
| Interface | USB 3.0 (3 m cable included) |
| I/O | Three MCX coaxial ports (2 trigger outputs, 1 trigger input), onboard programmable timing generator |
| Software | 64-bit LightField with real-time processing engine, IntelliCal lamp integration for automated wavelength and intensity calibration |
| Brand | Princeton Instruments (Teledyne) |
|---|---|
| Origin | USA |
| Model | IsoPlane81-BRX/BX-VR, IsoPlane81-BRX-UR |
| Spectral Range | 200–1100 nm |
| Focal Length | 80.0 mm |
| f-number | f/4 |
| Spectral Resolution (FWHM) | 0.1 nm |
| Slit Width | 10–500 µm |
| Sensor Format | 1024 × 256 |
| Cooling | Thermoelectric to –45 °C |
| Peak Quantum Efficiency | >95% (up to >97% with eXcelon™) |
| Interface | USB 3.0 |
| Grating Options | 150–4320 g/mm |
| Optical Coating | Protected silver |
| Brand | Princeton Instruments / Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Models | SP2150, SP2300, SP2500, SP2750 |
| Pricing | Upon Request |
| Brand | Princeton Instruments (Teledyne) |
|---|---|
| Origin | USA |
| Model Variants | TR555, TR557, TR777, DM55, DM77 |
| Spectral Range | 200 nm – 2.2 µm |
| Resolution (Additive Mode) | up to 0.13 cm⁻¹ (TR777) |
| Resolution (Subtractive Mode) | up to 0.4 cm⁻¹ |
| Stray Light Rejection | <1×10⁻⁶ (enabling Raman measurements within 5 cm⁻¹ of Rayleigh line) |
| Focal Length Options | 500 mm, 750 mm, 1000 mm, 1500 mm, 1750 mm, 2250 mm |
| Aperture Ratio | f/6.5 – f/9.7 |
| Grating Compatibility | Up to 1800 grooves/mm |
| Operating Modes | Additive (high-resolution), Subtractive (ultra-low stray light), Independent Dual/Triple Stage |
| Brand | PULUODY |
|---|---|
| Model | P-ICP-II |
| Origin | Shaanxi, China |
| Detection Principle | Rotating Disc Electrode Atomic Emission Spectrometry (RDE-AES) |
| Spectral Range | 190–800 nm |
| Optical Resolution | ≤0.015 nm |
| RF Generator Frequency | 27.12 MHz (stability ≤0.05%) |
| RF Power Output | 800–1600 W (stability ≤0.2%) |
| Grating Density | 2400 lines/mm |
| Grating Area | 80 × 110 mm |
| Sample Volume Required | >1 mL |
| Operating Temperature | 20–45 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Elemental Detection Capability | ≥61 elements |
| Detection Limit | down to 1 ppb (µg/L) for most metals |
| Linear Dynamic Range | 5 orders of magnitude |
| Analysis Speed | ≥4 elements per minute |
| Precision (RSD) | ≤1.5% |
| Stability (RSD) | ≤2.0% |
| Accuracy | ±3% (method-dependent) |
| Compliance Standards | ASTM D6595, ASTM D6728, NB/SH/T 0865, SN/T 1652, DL/T 1550, JJF (Defense) 1752018 |
| Brand | Rayscience |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | THz |
| Spectral Range | 0.1–4.0 THz |
| Spectral Resolution | <50 GHz (after FFT) |
| Dynamic Range | >70 dB (at peak) |
| Operation Modes | Transmission or Reflection |
| Sample-to-Source Distance | 1–40 cm |
| Emitter | Photoconductive Antenna |
| Detector | ZnTe Electro-Optic Crystal |
| Control Software | LabVIEW-based GUI |
| Interface | USB 2.0 & Bluetooth |
| Dimensions | 10.5" × 6.25" × 2.75" (267 × 159 × 70 mm) |
| Weight | <4.2 lbs (1.9 kg) |
| Brand | REMEX (Xi’an Remex Analytical Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RPSE-A |
| Pricing | Upon Request |
| Electrochemical Potential Range | −10 V to +10 V |
| Current Range | ±250 mA |
| Reference Electrode Input Impedance | ≥10 MΩ |
| Current Sensitivity | 1 × 10⁻⁹ A to 1 × 10⁻² A (8 decades) |
| Input Bias Current | <50 pA |
| Potential Increment | 1 mV |
| Scan Rate | 0.001–65 V/s |
| Wavelength Range (Monochromator) | 300–800 nm (standard), optional 200–800 nm |
| Spectral Resolution | 4.32 nm (adjustable via slit pairs: 0.4–7.2 nm, slit widths 0.05–1.0 mm) |
| Wavelength Accuracy | ±0.2% |
| Wavelength Repeatability | ±0.15% |
| Monochromator Scan Speed | 50 nm/s (standard), 100 nm/s (high-speed) |
| Exit Slit Width | 600 µm |
| Scan Modes | Time-based, fixed-point, range-scan, cyclic scan |
| Photodetector Wavelength Range | 230–700 nm |
| Peak Sensitivity Wavelength | 420 nm |
| Detection Method | Single-Photon Counting |
| Integration Times | 1 ms to 3600 s (12 selectable steps) |
| Origin | Shaanxi, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | RFFS-1 |
| Price | Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SIS-5100 |
| Pricing | Upon Request |
| Brand | SPECIM |
|---|---|
| Origin | Finland |
| Model | ArtScanner |
| Spectral Ranges | VNIR (400–1000 nm), NIR (900–1700 nm), SWIR (1000–2500 nm) |
| Maximum Scan Length | 190 cm |
| Illumination Source | Broadband Halogen Lamp (400–2500 nm) |
| Camera Mounting | Easy-Lock Modular Interface |
| Compatible Platform | Fully Interoperable with SisuCHEMA Hyperspectral Data Acquisition Suite |
| Brand | Specim |
|---|---|
| Origin | Finland |
| Model | sCMOS VNIR |
| Spectral Range | 400–1000 nm |
| Spectral Resolution (FWHM) | 2.9 nm (30 µm slit) |
| Spectral Sampling | 0.63–5.07 nm (adjustable via binning) |
| Spatial Resolution | 2184 pixels |
| Spectral Bands | 946 |
| Frame Rate | 100 fps (full frame), higher with binning |
| Pixel Size | 6.5 µm |
| Peak SNR | 170:1 (no binning) to 680:1 (8×2 binning) |
| Output | 16-bit CameraLink |
| Detector | Thermally Stabilized sCMOS |
| F-number | f/2.4 |
| Slit Width Options | 18, 30, 50, 80, or 150 µm |
| Effective Slit Length | 14.2 mm |
| Operating Temperature | +5 to +40 °C (non-condensing) |
| Storage Temperature | −20 to +50 °C |
| Dimensions | 400 × 110 × 120 mm |
| Weight | 2.0 kg |
| Power Supply | 110/230 V AC, 50/60 Hz or 24 V DC |
| Power Consumption | 60 W |
| Interface | CameraLink with BitFlow Carbon frame grabber |
| Exposure Time Range | 8.1–100 ms |
| Mechanical Shutter | Electromechanical |
| Mounting | Standard C-mount |