Oxygen Permeability Tester
Filter
Showing 61–87 of 87 results
| Brand | Labthink |
|---|---|
| Model | C230H |
| Principle | Coulometric O₂ Sensor + Isobaric Method |
| Standard Compliance | ASTM D3985, ASTM F1307, GB/T 19789, GB/T 31354 |
| Test Modes | Film, Sheet, Rigid/ Flexible Packaging (up to 3 L) |
| Chambers | 3 Independent Test Cells |
| OTR Range (Film) | 0.01–200 cm³/(m²·day) |
| OTR Range (Container) | 0.00005–1 cm³/(pkg·day) |
| Resolution | 0.001 cm³/(m²·day) |
| Repeatability | ±0.01 cm³/(m²·day) or ±2% (whichever is greater) |
| Temperature Control | 10–55 °C (±0.2 °C) |
| Humidity Control | 0–90% RH (±1%) |
| Sample Area | 50 cm² |
| Max Sample Thickness | ≤3 mm |
| Sample Size | 108 mm × 108 mm |
| Carrier Gas | ≥99.999% N₂, ≥0.28 MPa |
| Data Management | DataShield™ Audit-Trail Enabled |
| Regulatory Support | Optional 21 CFR Part 11 Compliance & GMP Computer System Validation |
| Brand | Labthink |
|---|---|
| Model | C230H |
| Measurement Principle | Coulometric Sensor + Isobaric Method |
| Standards Compliance | ASTM D3985, ASTM F1307, ASTM F1927, GB/T 19789, GB/T 31354, DIN 53380, JIS K7126-2-B, YBB 00082003-2015 |
| Test Range | 0.01–200 cm³/(m²·day) |
| Resolution | 0.001 cm³/(m²·day) |
| Repeatability | ±0.01 cm³/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C ±0.2 °C |
| Humidity Control | 0% RH, 5–90% RH ±1% RH, 100% RH |
| Test Chambers | 3 independent |
| Sample Area | 50 cm² (standard) |
| Max Sample Size | 108 mm × 108 mm |
| Max Sample Thickness | ≤3 mm |
| Package Testing Capacity | up to 3 L (optional) |
| Carrier Gas | ≥99.999% high-purity N₂, inlet pressure ≥0.28 MPa |
| Data Management | DataShield™ audit-trail-enabled software |
| Regulatory Support | Optional 21 CFR Part 11 compliance package |
| GMP/Computer System Validation Support | Optional |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | Labthink C230H OTR Tester |
| Price Range | USD 14,000 – 85,000 |
| Test Principle | Coulometric Oxygen Sensor + Isobaric Method |
| Standards Compliance | ASTM D3985, ASTM F1307, GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015 |
| Test Range | 0.01–200 cm³/(m²·day) |
| Resolution | 0.001 cm³/(m²·day) |
| Repeatability | ±0.01 cm³/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C ±0.2 °C |
| Humidity Control | 0% RH, 5–90% RH ±1% RH, 100% RH |
| Test Chambers | 3 independent chambers |
| Sample Area | 50 cm² (standard) |
| Max. Sample Size | 108 mm × 108 mm |
| Max. Sample Thickness | ≤3 mm |
| Package Testing Capacity | Up to 3 L (optional) |
| Carrier Gas | ≥99.999% high-purity N₂, inlet pressure ≥0.28 MPa (40.6 psi) |
| Interface | 1/8″ stainless steel tubing |
| Data Management | DataShield™ audit-trail-enabled software with CFR 21 Part 11 support (optional) |
| Operating System | Windows 10 on 12″ capacitive touchscreen |
| Connectivity | Ethernet, Wi-Fi (optional), third-party API integration supported |
| Brand | Labthink |
|---|---|
| Model | C230H |
| Test Principle | Isobaric Method with Coulometric Oxygen Sensor |
| Standards Compliance | ASTM D3985, ASTM F1307, ASTM F1927, GB/T 19789, GB/T 31354, DIN 53380, JIS K7126-2-B, YBB 00082003-2015 |
| Test Range | 0.01–200 cm³/(m²·day) |
| Resolution | 0.001 cm³/(m²·day) |
| Repeatability | ±0.01 cm³/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C (±0.2 °C) |
| Humidity Control | 0% RH, 5–90% RH (±1% RH), 100% RH |
| Test Chambers | 3 independent |
| Sample Size | 108 mm × 108 mm |
| Max Sample Thickness | ≤3 mm |
| Standard Test Area | 50 cm² |
| Carrier Gas | ≥99.999% high-purity N₂ (user-supplied) |
| Gas Inlet Pressure | ≥0.28 MPa (40.6 psi) |
| Gas Interface | 1/8″ stainless steel tubing |
| Optional Features | Package testing (up to 3 L), DataShield™ Data Integrity System, CFR 21 Part 11 compliance package, GMP-compliant computer system validation support |
| Brand | Labthink |
|---|---|
| Model | C230H |
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Price Range | USD 14,000 – 85,000 |
| Test Principle | Isobaric Method with Coulometric Oxygen Sensor |
| Standards Compliance | ASTM D3985, ASTM F1307, ASTM F1927 (optional), GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015 |
| Test Range | 0.01–200 cm³/(m²·day) [film] |
| Resolution | 0.001 cm³/(m²·day) |
| Repeatability | ±0.01 cm³/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C (±0.2 °C) |
| Humidity Control | 0–90% RH (±1% RH), 100% RH (optional) |
| Test Chambers | 3 independent chambers |
| Sample Area | 50 cm² (standard) |
| Max. Sample Size | 108 mm × 108 mm |
| Max. Thickness | ≤3 mm |
| Package Testing Capacity | up to 3 L |
| Carrier Gas | ≥99.999% high-purity N₂ |
| Inlet Pressure | ≥0.28 MPa (40.6 psi) |
| Gas Interface | 1/8″ stainless steel tubing |
| Optional Features | DataShield™ Data Integrity System, CFR 21 Part 11 Compliance Module, GMP Computer System Validation Support, Package Testing Mode |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | Labthink C230H |
| Price Range | USD 14,000 – 85,000 |
| Brand | Labthink |
|---|---|
| Model | C230H |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Price Range | USD 14,000 – 85,000 |
| Test Principle | Coulometric Sensor + Isobaric Method (ASTM D3985) |
| Test Range | 0.01–200 cm³/(m²·day) |
| Resolution | 0.001 cm³/(m²·day) |
| Repeatability | ±0.01 cm³/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C (±0.2 °C) |
| Humidity Control | 0% RH, 5–90% RH (±1% RH), 100% RH |
| Test Chambers | 3 independent |
| Sample Area | 50 cm² (standard) |
| Max. Sample Size | 108 mm × 108 mm |
| Max. Thickness | ≤3 mm |
| Package Testing Capacity | up to 3 L (optional) |
| Carrier Gas | ≥99.999% N₂, ≥0.28 MPa (40.6 psi) |
| Interface | 1/8″ stainless steel tubing |
| Data Compliance | Optional 21 CFR Part 11, GMP-compliant audit trail, DataShield™ secure data management |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | C230H |
| Price Range | USD 14,000 – 70,000 |
| Test Principle | Isobaric Coulometric Oxygen Sensor Method (ASTM D3985 compliant) |
| Test Range | 0.01–200 cm³/(m²·day) |
| Resolution | 0.001 cm³/(m²·day) |
| Temp Control | 10–55 °C ±0.2 °C |
| RH Control | 0%RH, 5–90%RH ±1%RH, 100%RH |
| Sample Capacity | 3 cavities |
| Max Package Volume | 3 L |
| Standard Test Area | 50 cm² |
| Specimen Size | 108 mm × 108 mm |
| Max Thickness | ≤3 mm |
| Carrier Gas | ≥99.999% N₂, ≥0.28 MPa |
| Interface | 1/8″ stainless steel tubing |
| Data Compliance | Optional 21 CFR Part 11, GMP audit trail, DataShield™ secure export |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | C230H |
| Price Range | USD 14,000 – 85,000 |
| Test Principle | Isobaric Method with Coulometric Oxygen Sensor |
| Standards Compliance | ASTM D3985, ASTM F1307, ASTM F1927, GB/T 19789, GB/T 31354, DIN 53380, JIS K7126-2-B, YBB 00082003-2015 |
| Test Range | 0.01–200 cm³/(m²·day) |
| Resolution | 0.001 cm³/(m²·day) |
| Repeatability | ±0.01 cm³/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C (±0.2 °C) |
| Humidity Control | 0% RH, 5–90% RH (±1% RH), 100% RH |
| Test Area | 50 cm² |
| Sample Size | 108 mm × 108 mm |
| Max Sample Thickness | ≤3 mm |
| Chamber Count | 3 |
| Package Testing Capacity | Up to 3 L (optional) |
| Carrier Gas | ≥99.999% N₂, ≥0.28 MPa (40.6 psi) |
| Gas Interface | 1/8″ stainless steel tubing |
| Data Management | DataShield™ audit-trail-enabled software |
| Regulatory Support | Optional 21 CFR Part 11 compliance package |
| OS | Windows 10 on 12″ industrial touchscreen |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Labthink-C230H |
| Price Range | USD 14,000 – 70,000 |
| Test Principle | Isostatic (Equal-Pressure) Method with Coulometric Oxygen Sensor |
| Standards Compliance | ASTM D3985, ASTM F1307, ASTM F1927, GB/T 19789, GB/T 31354, DIN 53380, JIS K7126-2-B, YBB 00082003-2015 |
| Test Range (Film) | 0.01–200 cm³/(m²·day) |
| Test Range (Package) | 0.00005–1 cm³/(pkg·day) |
| Resolution | 0.001 cm³/(m²·day) |
| Repeatability | ±0.01 cm³/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C ±0.2 °C |
| Humidity Control | 0% RH, 5–90% RH ±1% RH, 100% RH |
| Test Chambers | 3 independent |
| Sample Area | 50 cm² (standard) |
| Max. Package Volume | 3 L |
| Sample Size | 108 mm × 108 mm |
| Max. Sample Thickness | ≤3 mm |
| Carrier Gas | ≥99.999% N₂, inlet pressure ≥0.28 MPa (40.6 psi) |
| Gas Interface | 1/8″ stainless steel tubing |
| Optional Modules | DataShield™ Data Integrity System, CFR 21 Part 11 Compliance Package, GMP Computer System Validation Support, Package Testing Kit |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region | Domestic (China) |
| Model | C403H |
| Price Range | USD 28,000 – 115,000 |
| OTR Range | 0.01–200 cc/(m²·day) @ 50 cm² |
| WVTR Range | 0.005–40 g/(m²·day) @ 50 cm² |
| OTR Resolution | 0.0001 cc/(m²·day) |
| WVTR Resolution | 0.0001 g/(m²·day) |
| OTR Repeatability | ±0.01 cc/(m²·day) or ±1%, whichever is greater |
| WVTR Repeatability | ±0.005 g/(m²·day) or ±2%, whichever is greater |
| Temperature Range | 15–50 °C (optional 5–60 °C) |
| Temp Stability | ±0.05 °C |
| RH Range | 0–90 %RH ±2% |
| Test Chambers | 3 independent |
| Standard Test Area | 50 cm² |
| Sample Thickness Limit | ≤3 mm |
| Sample Size | 112 mm × 112 mm |
| Carrier Gas | ≥99.999% N₂, ≥99.5% O₂ |
| Inlet Pressure | ≥280 kPa |
| Power | 120 VAC ±10% / 60 Hz or 220 VAC ±10% / 50 Hz |
| Dimensions (W×D×H) | 600 × 500 × 700 mm |
| Net Weight | 100 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | C406H |
| Price Range | USD 28,000 – 98,000 |
| OTR Range | 0.02–200 cc/(m²·day) @ 50 cm² |
| WVTR Range | 0.02–40 g/(m²·day) @ 50 cm² |
| OTR Resolution | 0.0001 cc/(m²·day) |
| WVTR Resolution | 0.0001 g/(m²·day) |
| OTR Repeatability | ±0.02 cc/(m²·day) or ±1%, whichever is greater |
| WVTR Repeatability | ±0.02 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control Range | 10–50 °C (optional: 5–60 °C) |
| Temp Stability | ±0.15 °C |
| RH Range | 0%, 5–90% ±2%, 100% RH |
| Test Chambers | 6 independent chambers |
| Standard Test Area | 50 cm² |
| Sample Size | 11.2 cm × 11.2 cm |
| Max Sample Thickness | ≤3 mm |
| Carrier Gas | ≥99.999% N₂, ≥99.5% O₂ |
| Inlet Pressure | ≥280 kPa |
| Power Supply | 120 VAC ±10%, 60 Hz / 220 VAC ±10%, 50 Hz |
| Net Weight | 100 kg |
| Dimensions | 60 cm × 49 cm × 66 cm |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | DV-Series (Modular Platform) |
| Price Range | USD 14,000 – 70,000 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | PERME博密 VAC-V2 |
| Price Range | USD 14,000 – 98,000 |
| Brand | Labthink |
|---|---|
| Model | VAC-V2 |
| Principle | Differential Pressure Method |
| Test Gases | O₂, N₂, CO₂, H₂ |
| Standard Compliance | GB/T 1038-2000, ASTM D1434, ISO 2556, ISO 15105-1, JIS K7126, YBB00082003 |
| Measurement Range | 0.05–50,000 cm³/m²·24h·0.1MPa (extendable to ≥500,000 cm³/m²·24h·0.1MPa) |
| Test Chambers | 3 independent |
| Vacuum Resolution | 0.1 Pa |
| Vacuum Level in Test Chamber | <20 Pa |
| Temperature Control | 5–95 °C (±0.1 °C) |
| Humidity Control | 0%RH, 2–98.5%RH, 100%RH (optional humidifier) (±1%RH) |
| Specimen Size | Φ97 mm |
| Effective Permeation Area | 38.48 cm² |
| Test Pressure Range | −0.1 to +0.1 MPa |
| Gas Supply Pressure | 0.4–0.6 MPa |
| Data Interface | RS232 |
| Software Integration | Lystem™ Laboratory Data Management System |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® 2/22 H |
| Detection Principle | Coulometric Sensor (ASTM D3985) |
| Compliance | ASTM D3985, ISO 18369-4:2017, GB/T 11417.7–2012 |
| Sensor Type | Absolute, Zero-Calibration Coulometric Sensor |
| Measurement Range | Ultra-Low to High OTR (O₂) |
| Application Focus | Rigid Gas Permeable (RGP) & Soft Hydrogel/Silicone Hydrogel Contact Lens Materials |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® 2/22 |
| Detection Principle | Coulometric (COULOX®) Sensor-Based OTR Measurement |
| Compliance | ASTM D3985, ISO 15105-2, FDA 21 CFR Part 11 Ready (with optional software package) |
| Test Chamber | Horizontal, Interchangeable Sealed Test Cell with TruSeal® Dual-Gasket Design |
| Sample Handling | Manual single-sample loading per cycle |
| Typical OTR Range | 0.005–10,000 cm³/m²·day·atm (dependent on cell configuration and film barrier level) |
| Sensor Type | Absolute coulometric oxygen sensor (zero-calibration required) |
| Data Output | Real-time OTR curve, permeation onset time, steady-state slope calculation |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® 2/28 H |
| Detection Range | 0.05–200 cm³/(m²·day) |
| Sensor Type | Patented Coulometric Coulox® Absolute Sensor |
| Test Chambers | 4 Independent Horizontal Dual-Membrane Cells |
| Compliance | ASTM D3985, ISO 15105-2, FDA 21 CFR Part 11 (with optional audit trail software) |
| Temperature Control | Automatic, ±0.1 °C stability |
| Flow Control | Precision Mass Flow Controllers |
| Sealing Method | TruSeal™ Nitrogen Purge Ring |
| Sample Throughput | Up to 4 specimens simultaneously |
| Detection Limit | 0.05 cm³/(m²·day) |
| Response Time | <60 seconds to 90% signal stabilization |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® 2/40 |
| Test Principle | Coulometric Oxygen Detection |
| Sample Type | Whole Packages & Films |
| Standards Compliance | ASTM D3985, ASTM F1927, ISO 15105-2, JIS K-7126, ASTM F1307, GB/T 31354-2014 |
| Temperature Range | 10–50 °C (±0.2 °C) |
| Humidity Range | 5–90 %RH (±4 %RH) |
| OTR Range (Containers, Air) | 0.00025–1.0 cc/pkg·day |
| Resolution (Containers) | 0.0001 cc/pkg·day |
| Repeatability | ±0.0001 cc/pkg·day |
| Test Duration | 30–60 min |
| Sensor Type | Absolute Coulometric Oxygen Sensor (Faraday-based, calibration-free) |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® 2/48 |
| Compliance | ASTM D3985 |
| Sensor Type | Coulometric (Coulox®) |
| Chamber Configuration | 8-chamber (4 conditioning + 4 testing, parallel operation) |
| Humidity & Flow Control | Automated RH and carrier gas flow in both conditioning and test chambers |
| Sealing Technology | TruSeal® integrated seal verification |
| Warranty | 4-year sensor warranty |
| Software | MOCON Permatran-W® v6.x with 21 CFR Part 11 compliance options |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | Ox-TRAN® 2/48 |
| Compliance | ASTM D3985 |
| Sensor Technology | Coulometric (Coulox®) |
| Test Chambers | 8 (4 conditioning + 4 testing, parallel operation) |
| Humidity & Flow Control | Automated in both conditioning and test chambers |
| Sealing System | TruSeal® integrated |
| Warranty | 4-year sensor warranty |
| Software | Touchscreen GUI with audit trail, user-level access control, and GLP-compliant reporting |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® Model 2/12 |
| Test Range (Film) | 0.5–144,000 cc/m²·day |
| Test Range (Container) | 0.0025–720 cc/pkg·day |
| Resolution (Film) | 0.05 cc/m²·day |
| Repeatability | ±0.25 cc/m²·day |
| Temperature Range | 5–50 °C |
| Humidity Range (Film) | 0–90 %RH (±3 %RH) |
| Dual Test Cells | 2 × 50 cm² |
| Sample Size (Film) | 10.8 cm × 10.8 cm |
| Container Capacity | Up to 3 L |
| Compliance | ASTM F2622, ASTM D3985 |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® Model 2/22 |
| Standards Compliance | ASTM D3985, ASTM F1927, ASTM F1307, ISO 15105-2, GB/T 19789-2005, GB/T 31354-2014, YBB00082003-2015 |
| Test Range (Film) | 0.0005–200 cm³/(m²·day) |
| Resolution | 0.0002 cm³/(m²·day) |
| Temperature Control | 10–40 °C (±0.2 °C) |
| Humidity Control | 0–90% RH (dual-side independent) |
| Test Chamber | Dual 50 cm² chambers (standard), optional 5.64 cm² |
| Sample Format | Flat films (10.8 × 10.8 cm) or packages (≤3 L) |
| Sensor | Coulometric (Coulox®), NIST-traceable, zero-calibration required |
| Automation | Fully automated gas flow, pressure, temperature, and humidity control |
| Sealing Technology | TruSeal™ nitrogen curtain sealing |
| Interface | Integrated touchscreen, USB, Ethernet, remote operation via PermNet® Lite |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® Model 2/22 |
| Test Range (Film) | 0.05–200 cc/(m²·day) |
| Resolution | 0.02 cc/(m²·day) |
| Repeatability | ±0.02 cc/(m²·day) or ±1% |
| Temperature Control | 10–40 °C (±0.2 °C) |
| Humidity Control | 0–90% RH (dual-side independent) |
| Test Chamber | Dual 50 cm² chambers |
| Sample Size (Film) | 10.8 cm × 10.8 cm |
| Container Testing Capacity | Up to 3 L |
| Sensor Type | Coulometric (Coulox®) |
| Compliance | ASTM D3985, ISO 15105-2, YBB 00082003, GB/T 1038 |
| Interface | Touchscreen + USB + Ethernet |
| Optional | PermNet® Lite software, Package Test Conversion Chamber |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® Model 2/61 |
| Test Chambers | 6 × 10 cm² |
| Sample Types | Films & Rigid/ Flexible Packages (up to 3 L) |
| OTR Range (per chamber) | 0.5–1000 cm³/m²·day |
| Combined 6-chamber range | 0.1–200 cm³/m²·day |
| RH Control | 0–90% RH (film), 100% RH on O₂ side only |
| Temperature Range | Ambient to 65°C |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | OX2/231 |
| Price Range | USD 28,000 – 42,500 |
| Measurement Principle | Coulometric Sensor (ISO 15105-2 Compliant) |
| Test Method | Isobaric Equal-Pressure Mode |
| Chambers | 3 Independent Testing Cells |
| Temperature Control Range | 5–95 °C |
| Temp. Accuracy | ±0.1 °C |
| Humidity Control | 0%RH, 35–90%RH (±1%RH accuracy) |
| Film OTR Range | 0.01–6500 cm³/m²·d (standard), up to 63,000 cm³/m²·d (optional) |
| Container OTR Range | 0.0001–62 cm³/pkg·d |
| Film Resolution | 0.001 cm³/m²·d |
| Container Resolution | 0.00001 cm³/pkg·d |
| Test Area | 48 cm² |
| Sample Size (Film) | ≥150 mm × 94 mm or circular |
| Sample Size (Container) | ≤Φ120 mm × 400 mm (H) |
| Max. Thickness | 3 mm |
| Carrier Gas | 99.999% High-Purity N₂ |
| Flow Rate | 0–200 mL/min |
| Interface | 1/8″ Stainless Steel Tubing |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 730 × 590 × 350 mm |
| Net Weight | 56 kg |
| Standards Compliance | GB/T 19789, ASTM D3985, ASTM F2622, ASTM F1307, ASTM F1927, ISO 15105-2, JIS K7126-B, YBB 00082003 |
| Software | Embedded Win-based Control & Analysis Suite with Audit Trail, Multi-level User Access (5 tiers), Real-time Curve Logging (T, RH, Flow, OTR), Optional DSM Laboratory Data Management System Integration |
| Brand | Youyunpu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YP-DK3 |
| Price | USD 2,500 (FOB) |