Oxygen Permeability Tester
Filter
Showing 31–60 of 87 results
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Region | Domestic (China) |
| Model | Y310-1 |
| Pricing | Upon Request |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Region Classification | Domestic (China) |
| Model | Y310-2 |
| Price Range | USD 14,000 – 70,000 |
| Test Range | 0.02–16,500 cm³/(m²·24h) (film) |
| O₂ Resolution | 0.001 cm³/(m²·24h) |
| Temperature Control | 15–45 °C (optional 5–50 °C) |
| Temp Accuracy | ±0.1 °C |
| Humidity Range | 0%, 30–90%, or 100% RH |
| Humidity Accuracy | ±1% RH |
| Test Area | 50.24 cm² |
| Specimen Size | Φ100 mm |
| Max Thickness | ≤3 mm |
| Sample Capacity | 1–3 specimens per test cycle |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Gas Inlet | 1/8″ stainless steel tubing |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 100 kg |
| Power | 750 W, AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | Y310-3 |
| Price Range | USD 14,000 – 72,000 |
| Test Range | 0.02–16,500 cm³/(m²·24h) (film) |
| O₂ Detection Resolution | 0.001 cm³/(m²·24h) |
| Temperature Control | 15–45°C (5–50°C optional) |
| Humidity Control | 0%RH (dry), 30–90%RH, 100%RH |
| Test Area | 50.24 cm² |
| Specimen Size | Ø100 mm |
| Max Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Gas Inlet | 1/8″ stainless steel tubing |
| Dimensions (W×D×H) | 700×560×370 mm |
| Weight | 100 kg |
| Power | 750 W |
| Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Regional Category | Domestic (China) |
| Model | Y310-6 |
| Price Range | USD 14,000 – 70,000 |
| Test Range | 0.02–16,500 cm³/(m²·24h) (film) |
| O₂ Detection Resolution | 0.001 cm³/(m²·24h) |
| Temperature Control | 15–45 °C (optional 5–50 °C) |
| Temp. Accuracy | ±0.1 °C |
| Humidity Control | 0% RH (dry), 30–90% RH |
| Humidity Accuracy | ±1% RH |
| Test Area | 50.24 cm² |
| Specimen Size | Ø100 mm |
| Max. Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Gas Inlet | 1/8″ stainless steel tubing |
| Dimensions (W×D×H) | 700×560×370 mm |
| Weight | 100 kg |
| Power | 750 W |
| Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Region | Domestic (China) |
| Model | Y310-7 |
| Price Range | USD 14,000 – 70,000 |
| Test Range | 0.02–16,500 cm³/(m²·24h) (film) |
| O₂ Resolution | 0.001 cm³/(m²·24h) |
| Temp Control | 15–45°C (5–50°C optional) |
| Temp Accuracy | ±0.1°C |
| RH Control | 0% (dry), 30–90% RH |
| RH Accuracy | ±1% RH |
| Test Area | 50.24 cm² |
| Specimen Size | Ø100 mm |
| Max Thickness | ≤3 mm |
| Specimen Qty | 1–3 pcs per test |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Gas Inlet | 1/8″ stainless steel tubing |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 100 kg |
| Power | 750 W, AC 220 V, 50 Hz |
| Compliance | GB/T 19789–2005, ASTM D3985, ASTM F1927, ASTM F1307, ASTM F2622, ISO 15105-2, YBB00082003–2015, DIN 53380-3, JIS K-7126-B |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | Y310-8 |
| Price Range | USD 14,000 – 70,000 |
| Test Range | 0.02–16,500 cm³/(m²·24h) (film) |
| O₂ Resolution | 0.001 cm³/(m²·24h) |
| Temp Control | 15–45°C (5–50°C optional) |
| Temp Accuracy | ±0.1°C |
| RH Control | 0% (dry), 30–90% RH |
| RH Accuracy | ±1% RH |
| Test Area | 50.24 cm² |
| Specimen Size | Ø100 mm |
| Max Thickness | ≤3 mm |
| Sample Capacity | 1–3 specimens per test cycle |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Gas Inlet | 1/8″ stainless steel tubing |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 100 kg |
| Power | 750 W, AC 220 V, 50 Hz |
| Compliance | GB/T 19789–2005, ASTM D3985, ASTM F1927, ASTM F1307, ASTM F2622, ISO 15105-2, YBB00082003–2015, DIN 53380-3, JIS K-7126-B |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Y310-A0 |
| Price Range | USD 14,000 – 70,000 |
| Test Range | 0.02–16,500 cm³/(m²·24h) (film) |
| O₂ Resolution | 0.001 cm³/(m²·24h) |
| Temp Control | 15–45°C (5–50°C optional), ±0.1°C accuracy |
| RH Control | 0% (dry), 30–90% RH, ±1% RH accuracy |
| Test Area | 50.24 cm² |
| Specimen Size | Ø100 mm |
| Max Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Interface | 1/8″ stainless steel tubing |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 100 kg |
| Power | 750 W, AC 220 V, 50 Hz |
| Compliance | GB/T 19789–2005, ASTM D3985, ASTM F1927, ASTM F1307, ASTM F2622, ISO 15105-2, YBB00082003–2015, DIN 53380-3, JIS K-7126-B |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Y310-A1 |
| Price Range | USD 14,000 – 70,000 |
| Test Range | 0.02–16,500 cm³/(m²·24h) (film) |
| O₂ Resolution | 0.001 cm³/(m²·24h) |
| Temperature Control | 15–45°C (optional 5–50°C), ±0.1°C accuracy |
| Humidity Control | 0%RH (dry), 30–90%RH, 100%RH |
| Test Area | 50.24 cm² |
| Specimen Size | Ø100 mm |
| Max Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Gas Inlet | 1/8″ stainless steel tubing |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 100 kg |
| Power | 750 W, AC 220 V, 50 Hz |
| Compliance | GB/T 19789–2005, ASTM D3985, ASTM F1927, ASTM F1307, ASTM F2622, ISO 15105-2, YBB00082003–2015, DIN 53380-3, JIS K-7126-B |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Producer |
| Region | Domestic (China) |
| Model | Y310-A2 |
| Price Range | USD 14,000 – 70,000 |
| Test Principle | Isostatic (Equal-Pressure) Coulometric Detection |
| Standards Compliance | ASTM D3985, ASTM F1927, ASTM F1307, ASTM F2622, ISO 15105-2, GB/T 19789–2005, YBB00082003–2015, DIN 53380-3, JIS K-7126-B |
| Measurement Range | 0.02–16,500 cm³/(m²·24h) (film) |
| O₂ Resolution | 0.001 cm³/(m²·24h) |
| Temp Control | 15–45°C (5–50°C optional) |
| RH Control | 0%, 30–90%, 100% RH |
| Test Area | 50.24 cm² |
| Specimen Size | Φ100 mm |
| Max Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Gas Interface | 1/8″ stainless steel tubing |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 100 kg |
| Power | 750 W, AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Y310-A7 |
| Price Range | USD 14,000 – 70,000 |
| Test Range | 0.02–16,500 cm³/(m²·24h) (film) |
| O₂ Resolution | 0.001 cm³/(m²·24h) |
| Temperature Control | 15–45°C (5–50°C optional), ±0.1°C accuracy |
| Humidity Control | 0%RH (dry), 30–90%RH, ±1%RH accuracy |
| Test Area | 50.24 cm² |
| Specimen Size | Ø100 mm |
| Max Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Gas Inlet | 1/8″ stainless steel tubing |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 100 kg |
| Power | 750 W, AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | Y310-B1 |
| Price Range | USD 14,000 – 70,000 |
| OTR Range | 0.02–16,500 cm³/(m²·24h) (film) |
| OTR Resolution | 0.001 cm³/(m²·24h) |
| Temperature Control | 15–45 °C (optional 5–50 °C) |
| Temp Accuracy | ±0.1 °C |
| Humidity Control | 0% RH (dry), 30–90% RH |
| RH Accuracy | ±1% RH |
| Test Area | 50.24 cm² |
| Specimen Size | Ø100 mm |
| Max Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Gas Inlet | 1/8″ stainless steel tubing |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 100 kg |
| Power | 750 W, AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Region of Manufacture | Domestic (China) |
| Model | Y310-B2 |
| Price Range | USD 14,000 – 70,000 |
| Brand | GBPI |
|---|---|
| Model | Y310-T |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Price Range | USD 14,000 – 70,000 |
| Test Range | 0.02–16,500 cm³/(m²·24h) (film) |
| O₂ Resolution | 0.001 cm³/(m²·24h) |
| Temperature Control | 15–45°C (5–50°C optional), ±0.1°C accuracy |
| Humidity Control | 30–90% RH, ±1% RH accuracy |
| Test Area | 50.24 cm² |
| Specimen Size | Ø100 mm |
| Max Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Power | AC 220 V, 50 Hz, 750 W |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 100 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic |
| Model | Y310-T2 |
| Price Range | USD 14,000 – 70,000 |
| Test Range | 0.02–16,500 cm³/(m²·24h) (film) |
| O₂ Resolution | 0.001 cm³/(m²·24h) |
| Temp Control | 15–45°C (5–50°C optional), ±0.1°C accuracy |
| RH Control | 0% (dry), 30–90% RH, ±1% RH accuracy |
| Test Area | 50.24 cm² |
| Specimen Size | Ø100 mm |
| Max Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Interface | 1/8″ stainless steel tubing |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 100 kg |
| Power | 750 W, AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | Y310C |
| Price | USD 54,800 (FOB Guangzhou) |
| Test Principle | Coulometric Sensor (ASTM D3985 / ISO 15105-2) |
| Measurement Range | 0.05–1000 cm³/(m²·24 h) (up to 260,000 cm³/(m²·24 h) with mask accessory) |
| Resolution | 0.001 cm³/(m²·24 h) |
| Temperature Control | 15–45 °C ±0.1 °C |
| Permeation Area | 50.24 cm² (customizable down to 0.785 cm²) |
| Sample Size | Ø100 mm |
| Max Sample Thickness | ≤3 mm |
| Sample Capacity | 3 independent test cells |
| Carrier Gas Pressure | ≥0.1 MPa |
| Pneumatic Clamping Pressure | ≥0.3 MPa |
| Power | 750 W |
| Electrical Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Model | Y310E |
| Origin | Guangdong, China |
| Manufacturer | GBPI Packaging Instruments Co., Ltd. |
| Test Range | 0.02–16,500 cm³/(m²·24h) (film) |
| O₂ Detection Resolution | 0.001 cm³/(m²·24h) |
| Temperature Control | 15–45°C (5–50°C optional), ±0.1°C accuracy |
| Humidity Control | 30–90% RH (0–100% RH optional), ±1% RH accuracy |
| Test Area | 50.24 cm² |
| Specimen Size | Ø100 mm |
| Max. Specimen Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Gas Inlet | 1/8″ stainless steel tubing |
| Dimensions (W×D×H) | 700×560×370 mm |
| Weight | 100 kg |
| Power | 750 W, AC 220 V, 50 Hz |
| Compliance | GB/T 19789–2005, ASTM D3985, ASTM F1927, ASTM F1307, ASTM F2622, ISO 15105-2, YBB 00082003–2015, DIN 53380-3, JIS K-7126-B |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer | GBPI Packaging Instruments Co., Ltd. |
| Model | Y310G |
| Test Range | 0.02–16,500 cm³/(m²·24h) (film) |
| O₂ Resolution | 0.001 cm³/(m²·24h) |
| Temperature Control | 15–45 °C (optional 5–50 °C), ±0.1 °C accuracy |
| Humidity Control | 30–90 %RH (optional 0–100 %RH), ±1 %RH accuracy |
| Test Area | 50.24 cm² |
| Specimen Size | Ø100 mm |
| Max Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Power Supply | AC 220 V, 50 Hz, 750 W |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 100 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | Y310M |
| Price Range | USD 14,000 – 70,000 |
| Test Range | 0.02–16,500 cm³/(m²·24h) (film) |
| O₂ Detection Resolution | 0.001 cm³/(m²·24h) |
| Temperature Control | 15–45°C (5–50°C optional) |
| Humidity Control | 30–90% RH (100% RH optional) |
| Test Area | 50.24 cm² |
| Specimen Size | Ø100 mm |
| Max Thickness | ≤3 mm |
| Sample Capacity | 1–3 specimens per test cycle |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Gas Inlet | 1/8″ stainless steel tubing |
| Dimensions (W×D×H) | 700×560×370 mm |
| Weight | 100 kg |
| Power | 750 W, AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer | GBPI Packaging Instruments Co., Ltd. |
| Model | Y310P |
| Test Range | 0.02–16,500 cm³/(m²·24h) (film) |
| O₂ Resolution | 0.001 cm³/(m²·24h) |
| Temperature Control | 15–45 °C (5–50 °C optional), ±0.1 °C accuracy |
| Humidity Control | 30–90% RH (100% RH optional), ±1% RH accuracy |
| Test Area | 50.24 cm² |
| Specimen Size | Ø100 mm |
| Max Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Power | 750 W, AC 220 V, 50 Hz |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 100 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Region | Domestic (China) |
| Model | Y310T |
| Price Range | USD 14,000 – 70,000 |
| Test Range | 0.02–16,500 cm³/(m²·24h) (film) |
| O₂ Resolution | 0.001 cm³/(m²·24h) |
| Temp Control | 15–45°C (5–50°C optional) |
| Temp Accuracy | ±0.1°C |
| RH Control | 30–90% RH (0–100% RH optional) |
| RH Accuracy | ±1% RH |
| Test Area | 50.24 cm² |
| Specimen Size | Φ100 mm |
| Max Thickness | ≤3 mm |
| Sample Capacity | 1–3 specimens per test cycle |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Gas Inlet | 1/8″ stainless steel tubing |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 100 kg |
| Power | 750 W |
| Supply | AC 220 V, 50 Hz |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region | Domestic (China) |
| Model | C106H |
| Price Range | USD 14,000 – 98,000 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | C130H |
| Price Range | USD 14,000 – 85,000 |
| Brand | Labthink |
|---|---|
| Model | C203H |
| Principle | Coulometric oxygen sensor + isobaric method |
| Standards | ASTM D3985, ASTM F1307, GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015 |
| Test Range | 0.02–200 cc/(m²·day) (50 cm²), extendable to 400,000 cc/(m²·day) |
| Resolution | 0.0001 cc/(m²·day) |
| Repeatability | ±0.02 cc/(m²·day) or ±1%, whichever is greater |
| Temperature Range | 15–50 °C (standard), 5–60 °C (optional) |
| Temp. Stability | ±0.05 °C |
| Humidity Range | 0–90 %RH ±2 %RH |
| Test Area | 50 cm² (standard), 5 cm² / 1 cm² (optional masks) |
| Sample Size | 11.2 cm × 11.2 cm |
| Max. Thickness | 3 mm |
| Gas Supply | 99.999% N₂, 99.5% O₂ |
| Inlet Pressure | ≥280 kPa |
| Power | 120 VAC ±10% 60 Hz / 220 VAC ±10% 50 Hz |
| Dimensions | 600 mm × 500 mm × 700 mm |
| Weight | 100 kg |
| Brand | Labthink |
|---|---|
| Model | C203H |
| Measurement Principle | Coulometric Sensor + Isobaric Method |
| Standards Compliance | ASTM D3985, ASTM F1307, GB/T 19789, ISO 15105-2 (implied), JIS K7126-2-B |
| Test Area | 50 cm² (standard, triple independent chambers) |
| OTR Range | 0.01–200 cc/(m²·day) (50 cm²) |
| Resolution | 0.0001 cc/(m²·day) |
| Repeatability | ±0.01 cc/(m²·day) or ±1%, whichever is greater |
| Temperature Control | 15–50 °C (±0.05 °C stability) |
| RH Control | 0–90% RH (±1% for O₂ side, ±2% for carrier gas side) |
| Sensor Lifetime | ≥3× conventional coulometric sensors |
| Sample Thickness Limit | ≤3 mm |
| Power Supply | 120 VAC ±10% / 60 Hz or 220 VAC ±10% / 50 Hz |
| Net Weight | 100 kg |
| Dimensions | 600 × 500 × 700 mm |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | C203H-Labthink |
| Price Range | USD 28,000 – 98,000 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | C203H |
| Price Range | USD 14,000 – 98,000 |
| Test Principle | Isostatic (Equal-Pressure) Method with Coulometric Oxygen Sensor |
| Standards Compliance | ASTM D3985, ASTM F1307, ASTM F1927 (optional), GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015 |
| Test Area | 50 cm² (standard), 5 cm² / 1 cm² (optional), custom up to 400,000 cc/(m²·day) |
| Measurement Range | 0.01–200 cc/(m²·day) (50 cm²) |
| Resolution | 0.0001 cc/(m²·day) |
| Repeatability | ±0.01 cc/(m²·day) or ±1%, whichever is greater |
| Temperature Control Range | 15–50 °C (standard), 5–60 °C (custom) |
| Temp Stability | ±0.05 °C |
| RH Control Range | 0–90% RH (O₂ side: ±1% |
| carrier gas side | ±2%, optional) |
| Chamber Configuration | Triple independent test cells |
| Sample Size | 11.2 cm × 11.2 cm (4.4″ × 4.4″) |
| Max Sample Thickness | 3 mm (120 mil) |
| Gas Requirements | ≥99.999% N₂ (carrier), ≥99.5% O₂ (permeant) |
| Power Supply | 120 VAC ±10% / 60 Hz OR 220 VAC ±10% / 50 Hz |
| Dimensions | 600 × 500 × 700 mm |
| Weight | 100 kg (220 lbs) |
| Key Sensor | ppb-level Coulometric O₂ sensor (3× service life vs. conventional) |
| Automation | Fully automated sample clamping, drawer-style chamber actuation, real-time T/RH monitoring, closed-loop flow/temperature/humidity control |
| Software | Embedded industrial PC, Windows-based 12″ touch HMI, CFR 21 Part 11 & GMP-compliant modules (optional), DataShield™ data integrity suite |
| Brand | Labthink |
|---|---|
| Model | C203H |
| Measurement Principle | Isobaric Coulometric Sensor Method (ASTM D3985 compliant) |
| Test Area | 3 × 50 cm² independent chambers |
| OTR Range | 0.01–200 cc/(m²·day) (standard) |
| Resolution | 0.0001 cc/(m²·day) |
| Repeatability | ±0.01 cc/(m²·day) or ±1%, whichever is greater |
| Temperature Control | 15–50 °C (±0.05 °C stability) |
| RH Control | 0–90% RH (±1% for O₂ side |
| Sample Size | 11.2 cm × 11.2 cm |
| Max Thickness | 3 mm |
| Gas Requirements | 99.999% N₂ (carrier), 99.5% O₂ (permeant) |
| Power | 120 VAC ±10% / 60 Hz or 220 VAC ±10% / 50 Hz |
| Dimensions | 600 × 500 × 700 mm |
| Weight | 100 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | C206H |
| Price Range | USD 14,000 – 98,000 |
| Test Principle | Isobaric Method with Coulometric Oxygen Sensor |
| Standards Compliance | ASTM D3985, ASTM F1307, GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015 |
| Test Area | 50 cm² (standard), optional 5 cm² or 1 cm² MASK fixtures |
| OTR Range | 0.02–200 cc/(m²·day) [50 cm²], up to 400,000 cc/(m²·day) (custom) |
| Resolution | 0.0001 cc/(m²·day) |
| Repeatability | ±0.02 cc/(m²·day) or ±1%, whichever is greater |
| Temperature Range | 15–50 °C (standard), 5–60 °C (optional) |
| Temp Stability | ±0.15 °C |
| Humidity Range | 0% RH, 5–90% RH ±2% RH |
| Chamber Count | 6 independent test cells |
| Sample Size | 11.2 cm × 11.2 cm (4.4" × 4.4") |
| Max Thickness | 3 mm (120 mil) |
| Gas Supply | ≥280 kPa (40.6 PSI) N₂ (99.999%), O₂ (99.5%) |
| Power | 120 VAC ±10% 60 Hz / 220 VAC ±10% 50 Hz |
| Dimensions | 600 × 490 × 660 mm |
| Weight | 100 kg (220 lbs) |
| Control Interface | 12" Windows-based industrial touchscreen tablet |
| Data Security | Embedded industrial PC with CFR 21 Part 11-compliant audit trail option (optional) |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | C206H |
| Price Range | USD 14,000 – 98,000 |
| Test Principle | Isobaric Coulometric Sensor Method (ASTM D3985 Compliant) |
| Test Range | 0.02–200 cc/(m²·day) @ 50 cm² (standard) |
| optional MASK areas | 5 cm² (0.2–2000 cc/(m²·day)) and 1 cm² (1–10,000 cc/(m²·day)) |
| Resolution | 0.0001 cc/(m²·day) |
| Repeatability | ±0.02 cc/(m²·day) or ±1%, whichever is greater |
| Temperature Range | 15–50 °C (standard) |
| Temp. Stability | ±0.15 °C |
| Humidity Range | 0% RH, 5–90% RH ±2% RH |
| Test Chambers | 6 independent chambers |
| Chamber Area | 50 cm² (standard) |
| Sample Size | 11.2 cm × 11.2 cm |
| Max. Sample Thickness | 3 mm |
| Gas Supply | ≥99.999% N₂, ≥99.5% O₂ (user-supplied) |
| Inlet Pressure | ≥280 kPa (40.6 PSI) |
| Interface | 1/8" stainless steel tubing |
| Dimensions | 600 × 490 × 660 mm |
| Power | 120 VAC ±10% / 60 Hz OR 220 VAC ±10% / 50 Hz |
| Weight | 100 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | C230H Blister Oxygen Permeation Analyzer |
| Price Range | USD 14,000 – 70,000 |