Packaging Industry Specialized Instruments
Filter
Showing 1051–1062 of 1062 results
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YL-8809B |
| Price | USD 700 (FOB Guangdong) |
| Sampling Thickness | 0.1–1.5 mm (foam tape), 0.1–0.25 mm (PET protective film), 0.1–0.6 mm (fabric-backed tape) |
| Sampling Width | 15 mm, 24 mm, 25.4 mm (customizable) |
| Sampling Length | 300 mm |
| Sample Quantity per Cycle | 7 strips |
| Sampling Accuracy | ±0.01 mm |
| Dimensions (L×W×H) | 470 × 285 × 155 mm |
| Weight | 8 kg |
| Brand | Yuelian |
|---|---|
| Model | YL-S70 |
| Application | Peel Adhesion Testing of Pressure-Sensitive Adhesives (e.g., 3M VHB™ Tapes) |
| Load Capacity Options | 10 N to 5 kN (dual-range configurable) |
| Force Resolution | 1/500,000 full scale |
| Accuracy | Better than Class 0.5 per ISO 7500-1 |
| Crosshead Speed Range | 0.01–500 mm/min (adjustable in 0.01 mm/min increments) |
| Effective Travel | 450 mm |
| Data Acquisition Rate | 50 Hz |
| Compliance | ASTM D3330, ASTM D903, ISO 8510-2, PSTC-101, FINAT FTM 1 |
| Software | Windows-based control & analysis suite with audit trail, user-level permissions, and 21 CFR Part 11 readiness (optional validation package) |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Model | YL-S70CR |
| Load Capacity Options | 10 N to 5 kN (dual-capacity configuration available) |
| Control System | Full PC-based closed-loop servo control |
| Force Resolution | 1/500,000 of full scale |
| Force Accuracy | Better than ±0.5% FS |
| Displacement Resolution | 1/500,000 mm |
| Sampling Rate | 50 Hz |
| Effective Stroke | 450 mm |
| Speed Range | 0.01–500 mm/min (customizable) |
| Test Space Diameter | Φ140 mm |
| Power Supply | 220 V, 50–60 Hz |
| Net Weight | 45 kg |
| Dimensions (W×D×H) | 520 × 590 × 1061 mm |
| Interface | USB & RS-232 |
| Compliance | Designed for ASTM D3787, ISO 1798, IEC 61340-2-3, and GB/T 2423.17 environmental test alignment |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Model | YLB-SA20C |
| Force Range | 1–30 kN (Crush), 1–300 kg (Penetration) |
| Crush Load Accuracy | ±0.1 N |
| Penetration Force Accuracy | ±1% |
| Crush Speed | (5 ± 1) mm/s |
| Penetration Speed | 10–40 mm/s |
| Crush Stroke | 200/300 mm |
| Penetration Stroke | 200/300 mm |
| Test Chamber Dimensions | 250 × 300 × 250 mm (L×W×H) |
| Maximum Crush Load | 20 kN (default test setpoint: 13 ± 0.2 kN, held for 60 s) |
| Standard Crush Platen Area | 150 mm² or 200 mm² |
| Needle Diameters | φ3 / φ5 / φ8 mm stainless steel, 100 mm length |
| Chamber Material | Interior – 304 stainless steel |
| Viewing Window | 300 × 300 × 20 mm tempered blast-resistant glass + removable stainless-steel wire mesh guard |
| Interface | RS-232 and USB 2.0 |
| Power Supply | AC 380 V, 50 Hz |
| Net Weight | ~220 kg |
| Compliance | GB 31241-2014, GB/T 8897.4-2008 (IEC 60086-4:2007), YD/T 2344.1-2011, GB/T 21966-2008, YD 1268-2003, GB/T 19521.11-2005, UL 1642, UL 2054, IEC 62281:2004 |
| Brand | Yuelian/PW |
|---|---|
| Origin | USA |
| Model | HSR-2000 |
| Load Cell Options | 5 lb (standard), 2 lb & 10 lb (optional) |
| Force Accuracy | ±0.1% of full scale |
| Speed Modes | Constant (30–1000 fpm / 10–300 mpm) & Ramp (0–5 m/s in 1 m/s increments) |
| Temperature Range | 0–70 °C (32–150 °F) |
| Touchscreen | 5.7" integrated LCD |
| Dimensions (H×W×D) | 35 × 53 × 28 cm |
| Weight | 11 kg |
| Power Input | 85–265 VAC, 50/60 Hz |
| Data Sampling | Up to 400 points per test, adaptive sampling rate |
| Output Units | g, kg, oz, lb, N |
| Compliance | FINAT FTM 4 |
| Software Integration | EZ Data (USB export) |
| Brand | ZHENHUAFENXI |
|---|---|
| Origin | Hunan, China |
| Model | SQ006F |
| Maximum Furnace Temperature | 500 °C |
| Temperature Control Accuracy | ±2 °C at 500 °C |
| Effective Chamber Dimensions | 350 × 350 × 350 mm |
| Cold-to-500 °C Ramp Time | 120 min |
| Heating Power | 5 kW |
| Timer Range | 0–180 min |
| Air Compressor Capacity | 30 L |
| Air Compressor Power | 1 kW |
| Human-Machine Interface | 7-inch Touchscreen Industrial PC with SCADA-based Configuration Software |
| Compliance | GB/T 25994–2010, GB/T 3810.9–2016 |
| Brand | Zhongke Instrument (ZKDZ) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LSSD-01H |
| Pricing | Upon Request |
| Test Range | 0.00–600.00 kPa (standard), up to 1.60 MPa (optional) |
| Accuracy | Better than Class 0.5 |
| Pneumatic Interface | Φ6 mm polyurethane tubing |
| Air Supply Requirement | 0.4–0.9 MPa clean, dry air (user-supplied) |
| Flow Rate Control | 0.01–10 L/min |
| Pressure Holding Time | 0.1 s – 999999.9 s |
| Standard Nozzle Diameter | Φ6 mm (Φ4 mm and Φ1.6 mm optional) |
| Dimensions (L×W×H) | 420 × 320 × 150 mm |
| Test Chamber Footprint | 380 × 260 × 365 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 15 kg |
| Data Storage Capacity | 2000 test records |
| Compliance Standards | ISO 11607-1, ISO 11607-2, ASTM F1140, ASTM F2054, GB/T 10440, GB 18454, GB 19741, GB 17447, GB/T 17876, GB/T 10004, BB/T 0025, QB/T 1871, YBB00252005, YBB 00162002 |
| Brand | ZK Electronics |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BLD-200H |
| Force Capacity Options | 5 N / 10 N / 30 N / 50 N / 100 N / 200 N |
| Accuracy | Better than Class 0.5 |
| Resolution | 0.001 N |
| Test Speed Range | 0–500 mm/min (infinitely variable) |
| Clamp Width | 30 mm |
| Dimensions (L×W×H) | 450 × 380 × 240 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | ~38 kg |
| Compliance Standards | GB 4850, GB 7754, GB 8808, GB 13022, GB 7753, GB/T 17200, GB/T 2790, GB/T 2791, GB/T 2792, QB/T 2358 |
| Brand | ZK Electronics |
|---|---|
| Model | HGT-01H |
| Origin | Shandong, China |
| Manufacturer | Yes |
| Type | Domestic |
| Measured Gases | O₂ (standard), CO₂ (optional) |
| Principle | Electrochemical (O₂), NDIR Infrared Absorption (CO₂) |
| Sample Volume | O₂ ≤ 8 mL, CO₂ ≤ 15 mL (standard mode) |
| Resolution | 0.01% |
| Accuracy | ±0.2% (O₂), ±(0.03% + 5% of reading) (CO₂) |
| Response Time | ≤8 s (O₂), ≤10 s (CO₂) |
| Dimensions | 230 × 120 × 82 mm |
| Weight | 0.7 kg |
| Data Storage | 2000 records |
| Power | AC 220 V, 50 Hz |
| Brand | ZK Electronics |
|---|---|
| Model | HST-T01 |
| Origin | Shandong, China |
| Manufacturer | ZK Electronics Co., Ltd. |
| Type | Benchtop Pneumatic Heat Sealing Tester |
| Temperature Range | Ambient to 250 °C |
| Sealing Pressure | 50–700 kPa |
| Sealing Time | 0.01–99.99 s |
| Temperature Control Accuracy | ±1 °C |
| Sealing Area | 300 mm × 10 mm (customizable) |
| Heating Configuration | Dual-zone independent heating (top & bottom jaws) |
| Operating Modes | Manual & Automatic |
| Air Supply Requirement | ≤0.7 MPa, Φ6 mm polyurethane tubing |
| Power | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 550 × 330 × 460 mm |
| Net Weight | ~30 kg |
| Brand | ZKDZ |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SFJ-121 |
| Price Range | USD 170 – 1,400 |
| Standard Compliance | YBB00062004-2015, YBB00252003-2015 |
| Stainless Steel Sieve Mesh Apertures | 0.3 mm, 0.425 mm, 0.5 mm, 0.85 mm |
| Sieve Diameter | Φ200 mm |
| Vibratory Sieving Frequency (Optional Motorized Shaker) | 1400 cycles/min |
| Sieving Particle Size Range (with Motorized Shaker) | 0.025–3 mm |
| Standard Components | Quenched Steel Mortar & Pestle, Magnetic Separator, Four-Stage Stainless Steel Sieve Set (including sieve base and cover) |
| Optional Accessories | Electric Vibratory Sieve Shaker, Pre-Crushing Container |
| Brand | ZKWN |
|---|---|
| Origin | Beijing, China |
| Model | PMLS-1000 |
| Max. Load Capacity | 0–1000 N |
| Load Accuracy | ±1% of reading |
| Displacement Resolution | 0.01 mm |
| Displacement Accuracy | ±1% of reading |
| Crosshead Speed Range | 0.05–300 mm/min |
| Speed Accuracy | ±1% |
| Test Stroke | 0–800 mm (excluding fixtures) |
| Dimensions (L×W×H) | 435 × 275 × 1700 mm |
| Power Supply | 220 V, 50 Hz |
| Compliance | GB/T 6344–2008, GB/T 10808–2006, ISO 1798–1997 |