Packaging Industry Specialized Instruments
Filter
Showing 961–990 of 1185 results
| Brand | MOCON |
|---|---|
| Origin | Denmark |
| Model | LeakPointer 3 |
| Detection Limit | 50 µm |
| Test Cycle Time | 10 s per package |
| Max. Chamber Vacuum | –750 mbar |
| CO₂ Sensor Type | NDIR |
| Operating Temperature | +5 °C to +35 °C |
| Power Supply | 100–260 VAC, 50/60 Hz |
| Dimensions (open lid) | 617 mm H × 543 mm W × 400 mm D |
| Weight | 20 kg |
| Data Storage Capacity | >1,000,000 test records |
| Compliance | CE-marked |
| Recommended CO₂ Ambient Level | <1500 ppm |
| Calibration Interval | Every 12 months |
| Brand | MOCON (Dansensor) |
|---|---|
| Model | Lippke 5000 |
| Origin | Denmark |
| Application | Medical, Pharmaceutical & Food Packaging Seal Integrity Testing |
| Test Principles | Pressure Decay, Burst, Creep, Bubble, and Combined Testing |
| Compliance | ASTM F1140, F2054, F2095, F2096 |
| Max Test Volume | 90 L |
| Pressure Range | 10–5000 mbar |
| Resolution | 0.1 mbar (0–1000 mbar), 1 mbar (1000–5000 mbar) |
| Accuracy | ±0.5 mbar or ±1% of reading (whichever is greater) |
| Test Duration | 1–500 s |
| Data Storage | >1,000,000 records |
| Interface | USB 2.0 (Host & Device), RJ-45 Ethernet |
| Power | 90–264 VAC, 47–63 Hz, ≤50 W |
| Dimensions | 284 × 236.5 × 185 mm |
| Weight | 3.4 kg |
| IP Rating | IP20 |
| Operating Temp | +2 °C to +25 °C |
| Humidity | 10–90% RH (non-condensing) |
| Brand | Mocon |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Dansensor MAP Check 3 |
| Price Range | USD 6,800 – 13,600 |
| Oxygen Sensor Type | Electrochemical, Range: 0–100% O₂, Accuracy: ±0.01% abs (≤1% O₂), ±1% rel (>1% O₂) |
| CO₂ Sensor Type | Heated Dual-Beam NDIR, Range: 0–100% CO₂, Accuracy: ±0.5% abs, ±1.5% rel |
| Warm-up Time | 10 min (O₂), 8 min (CO₂) |
| Gas Flow Rate | 6–500 L/min |
| Inlet Pressure | 2–10 bar |
| Pressure Drop | 1 bar @ 10 bar inlet |
| Communication Interfaces | 2× RS232C, LAN 10/100 Mbit (Modbus TCP), USB, 4–20 mA / 0–10 V analog outputs, 24 VDC logic I/O |
| Power Supply | 103–132 / 207–264 VAC, auto-ranging, 47–63 Hz |
| Dimensions (H×W×D) | 192 × 230 × 375 mm |
| Weight | 8.5–11.5 kg |
| Enclosure Rating (optional) | IP45 (NEMA 3S) |
| Compliance | CE-marked, RoHS-compliant |
| Brand | Mocon |
|---|---|
| Origin | Denmark |
| Model | MAP Mix 9001 ME |
| Gas Channels | 2 or 3 |
| Flow Range | 20–400 L/min (40–850 SCFH) |
| Max Output Pressure | 6 bar |
| Input Pressure Range | 5.5–10 bar (varies by configuration) |
| Accuracy | ±2% (at 15–100% flow, 10–90% blend ratio) |
| Housing Material | Stainless Steel |
| Compliance | CE-marked |
| Dimensions (D×H×W) | 420 × 194 × 235 mm |
| Weight | 10–12 kg |
| Brand | Mocon |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MAP Mix Provectus |
| Price Range | USD 13,500 – 27,000 |
| Gas Types Supported | O₂, N₂, CO₂, Air, Ar (optional) |
| Mixing Configurations | 2-gas or 3-gas |
| Max Total Output Flow | 1500 L/min (3-gas mode) |
| Flow Accuracy | ±2% at ≥50 L/min |
| Input Pressure Range | 2–10 bar |
| Pressure Drop | ≤1 bar at 10 bar inlet |
| Flow Control Range per Gas | 6–500 L/min |
| Operating Temperature | 0–50 °C |
| Display | Touchscreen LCD |
| Connectivity | RS232 ×2, Ethernet (10/100 Mbit, Modbus TCP), USB, 24 VDC I/O |
| Power Supply | 103–132 / 207–264 VAC, 47–63 Hz or 24 VDC |
| Dimensions (H×W×D) | 192 × 230 × 375 mm |
| Weight | 12.0–14.0 kg |
| IP Rating (with optional kit) | IP45 (NEMA 3S) |
| Compliance | CE-marked |
| Predefined Programs | Up to 10 standard gas mixtures |
| Data Logging | Timestamped flow, pressure, mixture ratio, runtime, total consumption |
| Integration | Fully compatible with Dansensor MAP Check 3 gas analyzers |
| Brand | MOCON |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MultiCheck 2 |
| Price Range | USD 13,500 – 27,000 |
| Brand | Mocon |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Optech-O2 P |
| Power Supply | USB-powered (2.5 W) |
| Operating Temperature | 5–40 °C (Headspace Mode), 10–35 °C (Dissolved O₂ Mode) |
| Measurement Principle | Fluorescence-based Confocal Optical Sensing |
| Detection Range (Headspace) | 0.050%–25% O₂ (500 ppm–250,000 ppm) |
| Detection Range (ImPULSE™ Adhesive Sensor) | 0.001%–25% O₂ (10 ppm–250,000 ppm) |
| Repeatability (Needle Probe, 0–150 mmHg) | ±0.100% O₂ or ±5% of reading (whichever is greater) |
| Repeatability (Needle Probe, 150–1000 mmHg) | ±0.015% O₂ or ±2% of reading (whichever is greater) |
| Repeatability (ImPULSE™ Sensor) | ±0.015% O₂ or ±3% of reading (whichever is greater) |
| Probe Dimensions (w/ Needle) | 4.83 × 3.30 × 15.24 cm (H×W×D) |
| Probe Dimensions (w/o Needle) | 4.83 × 3.30 × 22.86 cm (H×W×D) |
| Preheat Time | 20 min |
| Compliance | CE, CSA, UL certified |
| Pressure Compensation | Integrated for needle-based measurements |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® 2/22 H |
| Detection Principle | Coulometric Sensor (ASTM D3985) |
| Compliance | ASTM D3985, ISO 18369-4:2017, GB/T 11417.7–2012 |
| Sensor Type | Absolute, Zero-Calibration Coulometric Sensor |
| Measurement Range | Ultra-Low to High OTR (O₂) |
| Application Focus | Rigid Gas Permeable (RGP) & Soft Hydrogel/Silicone Hydrogel Contact Lens Materials |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® 2/22 |
| Detection Principle | Coulometric (COULOX®) Sensor-Based OTR Measurement |
| Compliance | ASTM D3985, ISO 15105-2, FDA 21 CFR Part 11 Ready (with optional software package) |
| Test Chamber | Horizontal, Interchangeable Sealed Test Cell with TruSeal® Dual-Gasket Design |
| Sample Handling | Manual single-sample loading per cycle |
| Typical OTR Range | 0.005–10,000 cm³/m²·day·atm (dependent on cell configuration and film barrier level) |
| Sensor Type | Absolute coulometric oxygen sensor (zero-calibration required) |
| Data Output | Real-time OTR curve, permeation onset time, steady-state slope calculation |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® 2/28 H |
| Detection Range | 0.05–200 cm³/(m²·day) |
| Sensor Type | Patented Coulometric Coulox® Absolute Sensor |
| Test Chambers | 4 Independent Horizontal Dual-Membrane Cells |
| Compliance | ASTM D3985, ISO 15105-2, FDA 21 CFR Part 11 (with optional audit trail software) |
| Temperature Control | Automatic, ±0.1 °C stability |
| Flow Control | Precision Mass Flow Controllers |
| Sealing Method | TruSeal™ Nitrogen Purge Ring |
| Sample Throughput | Up to 4 specimens simultaneously |
| Detection Limit | 0.05 cm³/(m²·day) |
| Response Time | <60 seconds to 90% signal stabilization |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® 2/40 |
| Test Principle | Coulometric Oxygen Detection |
| Sample Type | Whole Packages & Films |
| Standards Compliance | ASTM D3985, ASTM F1927, ISO 15105-2, JIS K-7126, ASTM F1307, GB/T 31354-2014 |
| Temperature Range | 10–50 °C (±0.2 °C) |
| Humidity Range | 5–90 %RH (±4 %RH) |
| OTR Range (Containers, Air) | 0.00025–1.0 cc/pkg·day |
| Resolution (Containers) | 0.0001 cc/pkg·day |
| Repeatability | ±0.0001 cc/pkg·day |
| Test Duration | 30–60 min |
| Sensor Type | Absolute Coulometric Oxygen Sensor (Faraday-based, calibration-free) |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® 2/48 |
| Compliance | ASTM D3985 |
| Sensor Type | Coulometric (Coulox®) |
| Chamber Configuration | 8-chamber (4 conditioning + 4 testing, parallel operation) |
| Humidity & Flow Control | Automated RH and carrier gas flow in both conditioning and test chambers |
| Sealing Technology | TruSeal® integrated seal verification |
| Warranty | 4-year sensor warranty |
| Software | MOCON Permatran-W® v6.x with 21 CFR Part 11 compliance options |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | Ox-TRAN® 2/48 |
| Compliance | ASTM D3985 |
| Sensor Technology | Coulometric (Coulox®) |
| Test Chambers | 8 (4 conditioning + 4 testing, parallel operation) |
| Humidity & Flow Control | Automated in both conditioning and test chambers |
| Sealing System | TruSeal® integrated |
| Warranty | 4-year sensor warranty |
| Software | Touchscreen GUI with audit trail, user-level access control, and GLP-compliant reporting |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® Model 2/12 |
| Test Range (Film) | 0.5–144,000 cc/m²·day |
| Test Range (Container) | 0.0025–720 cc/pkg·day |
| Resolution (Film) | 0.05 cc/m²·day |
| Repeatability | ±0.25 cc/m²·day |
| Temperature Range | 5–50 °C |
| Humidity Range (Film) | 0–90 %RH (±3 %RH) |
| Dual Test Cells | 2 × 50 cm² |
| Sample Size (Film) | 10.8 cm × 10.8 cm |
| Container Capacity | Up to 3 L |
| Compliance | ASTM F2622, ASTM D3985 |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® Model 2/22 |
| Standards Compliance | ASTM D3985, ASTM F1927, ASTM F1307, ISO 15105-2, GB/T 19789-2005, GB/T 31354-2014, YBB00082003-2015 |
| Test Range (Film) | 0.0005–200 cm³/(m²·day) |
| Resolution | 0.0002 cm³/(m²·day) |
| Temperature Control | 10–40 °C (±0.2 °C) |
| Humidity Control | 0–90% RH (dual-side independent) |
| Test Chamber | Dual 50 cm² chambers (standard), optional 5.64 cm² |
| Sample Format | Flat films (10.8 × 10.8 cm) or packages (≤3 L) |
| Sensor | Coulometric (Coulox®), NIST-traceable, zero-calibration required |
| Automation | Fully automated gas flow, pressure, temperature, and humidity control |
| Sealing Technology | TruSeal™ nitrogen curtain sealing |
| Interface | Integrated touchscreen, USB, Ethernet, remote operation via PermNet® Lite |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® Model 2/22 |
| Test Range (Film) | 0.05–200 cc/(m²·day) |
| Resolution | 0.02 cc/(m²·day) |
| Repeatability | ±0.02 cc/(m²·day) or ±1% |
| Temperature Control | 10–40 °C (±0.2 °C) |
| Humidity Control | 0–90% RH (dual-side independent) |
| Test Chamber | Dual 50 cm² chambers |
| Sample Size (Film) | 10.8 cm × 10.8 cm |
| Container Testing Capacity | Up to 3 L |
| Sensor Type | Coulometric (Coulox®) |
| Compliance | ASTM D3985, ISO 15105-2, YBB 00082003, GB/T 1038 |
| Interface | Touchscreen + USB + Ethernet |
| Optional | PermNet® Lite software, Package Test Conversion Chamber |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | OX-TRAN® Model 2/61 |
| Test Chambers | 6 × 10 cm² |
| Sample Types | Films & Rigid/ Flexible Packages (up to 3 L) |
| OTR Range (per chamber) | 0.5–1000 cm³/m²·day |
| Combined 6-chamber range | 0.1–200 cm³/m²·day |
| RH Control | 0–90% RH (film), 100% RH on O₂ side only |
| Temperature Range | Ambient to 65°C |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | PERMATRAN-C® 4/30 |
| Detection Limit | 0.5 cm³/(m²·day) |
| Measurement Principle | Modulated Infrared Spectroscopy |
| Compliance | ASTM F2476 |
| Test Chamber | Dual independent horizontal chambers with interchangeable fixtures |
| Temperature Control | Automated, ±0.1 °C stability |
| Flow Control | Fully automated mass flow regulation |
| Throughput | High—real-time CO₂ concentration monitoring enables rapid equilibrium detection |
| Sample Types | Films, laminates, pouches, trays, bottles, and rigid containers |
| Range | 0.5–8,000 cm³/(m²·day), extendable to ~72,000 cm³/(m²·day) via area reduction factor (×9) |
| Brand | Mocon |
|---|---|
| Origin | USA |
| Model | PERMATRAN-W® 1/50 |
| Test Range | 0.1–100 cm³/m²·day |
| Temperature Range | 5–50 °C (W-type configuration) |
| Humidity Range | 35–90 %RH (standard), up to 100 %RH (W-type) |
| Test Area | 2 chambers × 50 cm² |
| Repeatability | ±0.05 g/m²·day or ±3 % of reading (whichever is greater) |
| RH Sensor Accuracy | ±3 %RH |
| Carrier Gas | Dry nitrogen or oil-free compressed air |
| Compliance | ASTM E398, ISO 15106-1, GB/T 30412–2013 |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PERMATRAN-W® Model 101K |
| Quotation | Upon Request |
| Test Range | 500–100,000 g/m²·day |
| Test Temperature | 20–50 °C with Automatic Temperature Control |
| Atmospheric Pressure Compensation | Standard |
| Flow Rate Compensation | Standard |
| Number of Test Cells | 6 |
| Cell Area | 10 cm² per cell |
| Compliance | ASTM D6701, WSP 001.0.R3 (12) (EDANA & INDA) |
| Brand | Mocon |
|---|---|
| Origin | USA |
| Model | PERMATRAN-W® Model 3/34 |
| Test Range (Film) | 0.005–100 g/(m²·day) |
| Resolution | 0.001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2% |
| Temperature Range | 10–40 °C (±0.2 °C) |
| Humidity Range | 5–90% RH, up to 100% RH |
| Test Chamber | Dual 50 cm² chambers |
| Sample Size (Film) | 10.8 × 10.8 cm |
| Package Capacity | Up to 3 L |
| Compliance | ASTM F1249, ISO 15106-2, JIS K7129, TAPPI T557, GB/T 26253–2010, GB/T 31355–2014, YBB00092003–2015 |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | PERMATRAN-W® Model 3/34G |
| Test Range (Film) | 0.005–100 g/(m²·day) |
| Resolution | 0.001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2% |
| Temperature Control | 10–40 °C (±0.2 °C) |
| Humidity Range | 5–90% RH, up to 100% RH |
| Test Chamber Area | 2 × 50 cm² |
| Sample Size (Film) | 10.8 cm × 10.8 cm |
| Package Capacity | Up to 3 L |
| Sensor Type | Coulometric Moisture Detector |
| Sealing Technology | TruSeal™ Nitrogen Perimeter Purge |
| Interface | Touchscreen + Ethernet/USB |
| Data Storage | Internal (100 test records) + PermNet® Lite remote software support |
| Compliance | ASTM F1249, ISO 15106-3, TAPPI T464, USP <671>, FDA 21 CFR Part 11 (with audit trail enabled) |
| Brand | Mocon |
|---|---|
| Origin | USA |
| Model | PERMATRAN-W® Model 3/61 |
| Test Principle | Infrared Detection (ASTM F1249-compliant) |
| Sample Capacity | 6 independent test cells (10 cm² each) |
| WVTR Range (per cell) | 0.05–500 g/m²·day |
| Combined 6-cell Range | 0.01–85 g/m²·day |
| RH Control | 35–90% RH (film), up to 100% RH (container mode) |
| Temperature Range | Ambient to 65°C |
| Calibration Traceability | NIST-traceable standard films |
| Sample Types | Flat films (10.8 × 10.8 cm), rigid/flexible packages (≤3 L) |
| Brand | Norman Tool |
|---|---|
| Origin | USA |
| Model | RCA 7-IBB-CC |
| Load Options | 55 g / 175 g / 275 g |
| Counter Type | Digital LCD (0–999,999 cycles) |
| Sample Mounting | Flat & 3D fixtures |
| Compliance | ASTM F2357-04 |
| Power Supply | 220 V, 50/60 Hz, 5 A |
| Weight | ~17 kg |
| Accessories | Calibration plate (certified), surface flatness gauge, hex key set, LED magnifier, two counterweights (55 g & 175 g), three O-rings, 3D sample holder |
| Brand | Norman Tool |
|---|---|
| Origin | USA |
| Type | RCA-Type Rotating Drum Abrasion Tester |
| Compliance | ASTM F2357-04 |
| Load Options | 55 g / 175 g / 275 g (standard: 275 g) |
| Counter Type | Digital LCD (0–999,999 cycles, programmable) |
| Sample Mounting | Flat & 3D fixtures included |
| Magnification | Integrated lamp-equipped magnifier |
| Power Supply | 220 V, 50/60 Hz, 5 A |
| Weight | ~17 kg |
| Accessories | Calibration plate (certified), surface level gauge, hex key set, two O-rings, stereo sample holder, two counterweight masses (55 g & 175 g) |
| Brand | Norman Tool |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | RCA7-IBB |
| Pricing | Upon Request |
| Brand | Normantool |
|---|---|
| Origin | USA |
| Model | 7-IBB |
| Load Options | 55 g, 175 g, 275 g |
| Rotational Speed | 16 rpm (50 Hz) / 18 rpm (60 Hz) |
| Counter Type | Mechanical rotary counter |
| Sample Mounting | Dual-mode (flat & 3D) |
| Power Supply | 220 V, 50/60 Hz, 5 A |
| Weight | ~17 kg |
| Compliance | ASTM F2357-04 |
| Brand | Normantool |
|---|---|
| Origin | USA |
| Model | 7-IBB / 7-IBB-CC |
| Compliance | ASTM F2357-04 |
| Load Options | 55 g, 175 g, 275 g |
| Counter Type | Mechanical (7-IBB) or Digital LCD (0–999,999 cycles, 7-IBB-CC) |
| Sample Mounting | Flat & 3D Fixtures |
| Power Supply | 220 V, 50/60 Hz, 5 A |
| Weight | ~17 kg |
| Accessories | Calibration Plate (certified), Surface Level Gauge, Hex Key Set, LED Magnifier, Two Counterweights (55 g & 175 g), O-Rings (×3), 3D Sample Holder |
| Brand | North Guang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BG-8205 |
| Load on Specimen | 26.7 ± 0.2 N |
| Roller Shaft Speed | 76 ± 2 rpm |
| Abrasive Wheel Speed | 34 ± 1 rpm |
| Adjustable Angle Between Roller and Wheel | 15° or 25° |
| Power Supply | AC 220 V |
| Power Consumption | 250 W |
| Dimensions (L×W×H) | 600 × 480 × 400 mm |
| Net Weight | 60 kg |
| Brand | North Guang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CZF-5 |
| Price | USD 1,700 (FOB Beijing) |
| Burner Tip ID | 9.5 mm ± 0.3 mm |
| Burner Length | 100 mm ± 10 mm |
| Flame Angle Adjustment | 0–45° (manual, calibrated scale) |
| Ignition Support | Medical-grade cotton pad |
| Fuel Gas | 98% methane (calibrated), or natural gas (37 MJ/m³ ± 1 MJ/m³), or propane |
| Flame Temperature Ramp | 100°C ± 5°C to 700°C ± 3°C in 44 s ± 2.0 s or 54 s ± 2.0 s (verified with thermal calibration kit) |
| Calibration Kit Options | φ5.5 mm Cu slug (1.76 ± 0.01 g) or φ9 mm Cu slug (10.00 ± 0.05 g), imported controller |
| Thermocouple | K-type, insulated, high-temp armored, Ø0.5 mm |
| Timing Range | 1.0 s – 999.9 s (digital presettable) |
| Repetition Cycles | 1 – 9999 (digital presettable) |
| Chamber Volume | 0.75 m³ (optional: 0.5 m³ or 1.0 m³) |
| External Dimensions | 1330 mm (W) × 730 mm (D) × 1500 mm (H) |
| Enclosure Material | Powder-coated steel plate |
| Exhaust Port | Ø100 mm |
| Power Supply | AC 220 V, 50 Hz, 5 A |