Packaging Industry Specialized Instruments
Filter
Showing 1021–1050 of 1062 results
| Brand | WEISSTECH |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | WSPL-M |
| Price | ¥19,900 |
| Test Method | Semi-Automatic |
| Measurement Range | 200–5600 kPa |
| Unit Options | kPa, psi (lbf/in²), kgf/cm² |
| Accuracy | ±0.5% FS |
| Clamping Ring Diameter | Upper & Lower Rings: 31.5 mm |
| Hydraulic Oil Speed | 170 ± 15 mL/min |
| Display | LED Digital Display |
| Hydraulic Medium | Imported Silicone Oil |
| Power Supply | 220 V, 50 Hz |
| Safety Protection | Automatic pressure relief upon overpressure detection |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.161 |
| Compliance Standards | JIS C 3003, IEC 60172, IEC 60851 |
| Test Principle | Gravimetric static elongation under controlled suspension time |
| Measurement Output | Dimensional change (mm) of wound coil after 1-minute load retention and 1-minute recovery |
| Operating Mode | Manual loading, gravity-driven extension, timed dwell |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.162 |
| Standard Compliance | JIS P8147, ASTM D1894, ASTM D3248, TAPPI T503, TAPPI T542, TAPPI T815 |
| Measurement Principle | Inclined-plane static/dynamic friction coefficient determination via tangent of slip initiation angle (tanθ) |
| Test Surface Length | 600 mm |
| Specimen Platform | Tempered glass top plate |
| Slider Dimensions | 60 mm × 100 mm |
| Slider Mass | 1000 g |
| Tilt Angle Range | 0–70° (graduated in 0.25° increments) |
| Tilt Speed | 1°/s (adjustable) |
| Power Supply | 220 V, single-phase, 3 A, 50/60 Hz |
| Dimensions (W×D×H) | 750 × 350 × 425 mm |
| Weight | ~29 kg |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.162-FS |
| Standards Compliance | JIS K7125, ISO 8295, ASTM D3247, TAPPI T816, P8147 |
| Measurement Principle | Lateral pull-type static & kinetic COF determination via load cell transduction |
| Sample Mounting | Dual-surface clamping (stationary bed + sliding sled) |
| Output | μs (static) and μk (kinetic) values |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.162-S5 |
| Test Method | Inclined-plane static/dynamic COF measurement |
| Standards | JIS P8147, ASTM D1894, ASTM D3248, TAPPI T503, T542, T815 |
| Stations | 5 parallel test positions |
| Display | Integrated LCD with print output |
| Data Output | Individual and averaged COF values |
| Compliance | Suitable for QC labs operating under ISO/IEC 17025, GLP, and packaging material validation per FDA 21 CFR Part 11 (when paired with compliant software) |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.163 |
| Standards Compliance | JIS C 3003, IEC 60172, IEC 60851-5 |
| Test Method | Springback Deflection Measurement |
| Operating Principle | Mechanical Resilience Assessment via Controlled Coiling and Release |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.171 |
| Standards Compliance | JIS A 5756, JIS K 6262, ASTM D395 (Method A & B), ISO 815 |
| Application | Compression set measurement of vulcanized and thermoplastic elastomers |
| Load Configuration | Fixed-height compression via precision-machined spacers |
| Test Specimen Dimensions | Standard cylindrical specimens (diameter 29.0 ± 0.5 mm, height 12.5 ± 0.5 mm) per ASTM D395 and ISO 815 |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.220 |
| Test Standards | JIS K7124-1, JIS Z1702, JIS Z1707, ASTM D1709, ISO 7765-1 |
| Drop Height (Method A) | 0.66 ± 0.01 m |
| Drop Height (Method B) | 1.50 ± 0.01 m |
| Dart Geometry (Method A) | Hemispherical, φ38 ± 1 mm, 40 g |
| Dart Geometry (Method B) | Hemispherical, φ50 ± 1 mm, 320 g |
| Max Dart Mass | 890 g (Method A), 1410 g (Method B) |
| Clamp Inner Diameter | φ125 ± 2 mm |
| Pneumatic Pressure Range | 0–1.0 MPa (graduated at 0.05 MPa intervals) |
| Power Supply | AC 100 V, 15 A, 50/60 Hz |
| Air Supply Requirement | ≥0.5 MPa |
| Dimensions (W×D×H) | ≈620 × 400 × 2150 mm |
| Weight | ≈55 kg |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.305-YPL |
| Applicable Standards | JIS K6404-11, P8112, P8131, TAPPI T403, T807, T810, ISO 2758, ISO 2759 |
| Pressure Range | Low-pressure configuration (typically up to 1.6 MPa / 232 psi) |
| Test Principle | Hydraulic diaphragm burst method with clamped specimen |
| Display | Digital readout |
| Compliance | Designed for GLP-compliant lab environments with manual data recording capability |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.315 |
| Test Principle | Pendulum-based Elmendorf tear method |
| Standards Compliance | JIS K7128-2, ISO 1974, TAPPI T414, ASTM D1922 (equivalent), ISO 6383-2 |
| Load Options | Standard and Low-Load configurations |
| Measurement Unit | mN (millinewtons) |
| Specimen Requirements | Pre-cut slit in rectangular strip (63 mm × 75 mm typical) |
| Readout | Analog arc scale with vernier or digital display (optional upgrade) |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.318 |
| Applicable Standards | JIS K5400, JIS K6549, JIS Z0208, TAPPI T448, TAPPI T464, ISO 2528 |
| Measurement Principle | Gravimetric Cup Method (Desiccant or Water-filled) |
| Temperature & Humidity Control | Requires External Environmental Chamber |
| Sample Format | Flat Sheet Specimens (Circular or Square, Typically 50–100 mm Diameter) |
| Compliance | Designed for Conformance with ASTM E96, ISO 2528, and JIS Z0208 Gravimetric Test Protocols |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.323-AUTO |
| Test Standards | JIS L1096, ASTM D726, TAPPI T460, ISO 5636-5, P8117 |
| Sample Size | 50 × 50 mm |
| Clamp Orifice Diameter | φ28.6 ± 0.1 mm (Effective Area: 642 mm²) |
| Outer Cylinder ID | φ82.6 mm |
| Inner Cylinder OD/ID | φ76.2 / φ74 mm |
| Inner Cylinder Height | 254 mm |
| Inner Cylinder Mass | 567 ± 0.5 g |
| Air Volume Range | 0–100 mL (25 mL graduations), 100–350 mL (50 mL graduations) |
| Timing Resolution | 0.1 sec (Digital Timer, Max 99999.9 sec) |
| Detection Method | Photoelectric Sensor |
| Power Supply | AC 100 V, 1-phase, 3 A, 50/60 Hz |
| Main Unit Dimensions/Weight | ≈ W150 × D230 × H420 mm / ≈ 20 kg |
| Control Panel Dimensions/Weight | ≈ W250 × D450 × H280 mm / ≈ 8 kg |
| Optional Accessories | Silicone Oil, Porous Plug Adapter (φ10 mm) |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.401 |
| Test Method | Calcium Chloride Desiccant Method (JIS L 1099 Type A-1) |
| Application | Textile Fabric Moisture Vapor Transmission Evaluation |
| Cup Type | Bolt-Tightened Sealed Permeation Cell |
| Compliance | JIS L 1099–2012 Annex A1 (Desiccant Method) |
| Dimensions | Standard 60 mm inner diameter test area |
| Material | High-Purity Stainless Steel (SUS316) body with fluoropolymer-sealed gasket |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | YL-8809A |
| Pricing | Upon Request |
| Sampling Thickness | 0.1–1.5 mm (foam tape), 0.1–0.25 mm (PET protective film), 0.1–0.6 mm (fabric tape) |
| Sampling Width | 15 mm, 24 mm, 25.4 mm (customizable) |
| Sampling Length | 300 mm |
| Sample Quantity per Cycle | 6 strips |
| Sampling Accuracy | ±0.1 mm |
| Dimensions (L×W×H) | 420 × 330 × 145 mm |
| Weight | 8 kg |
| Brand | Youyunpu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YP-DK3 |
| Price | USD 2,500 (FOB) |
| Brand | Yuelian / PW |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PW-212 |
| Pricing | Upon Request |
| Test Area | 100 ± 0.2 cm² |
| Specimen Area | 122.718 ± 0.2 cm² |
| Liquid Height | 10 mm (standard) |
| Water Volume | 100 ± 5 mL |
| Roller Length | 200 ± 0.5 mm |
| Roller Mass | 10 ± 0.5 kg |
| Cup Material | Full 304 stainless steel |
| Lid Material | Anodized magnesium-aluminum alloy (fully sealed, acid/alkali resistant) |
| Sealing Ring | Pure silicone |
| Lid Knob Sleeve | High-strength machined copper |
| Rotational Locking Mechanism | Copper alloy, wear-resistant |
| Dimensions (W × D × H) | 396 × 315 × 300 mm |
| Weight | 28 kg |
| Key | Brand: Yuelian/PW |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PW-6600 |
| Price | Upon Request |
| Load Range | 0–3000 N |
| Upper Platen Diameter | 124 mm |
| Lower Platen Diameter | 127 mm |
| Test Height Range | 83 mm |
| Accuracy | ±1% of reading |
| Test Speed | 12 mm/min |
| Return Speed | 12 mm/min |
| Display | 7-inch high-contrast TFT LCD with real-time force-displacement curve |
| Data Storage | 50 test records onboard |
| Interface | Ethernet port for PC connectivity |
| Software | Dedicated Windows-based testing software with report generation (A4), statistical analysis (mean, min/max, SD), and automatic unit conversion (ECT, RCT, PAT, FCT, CMT) |
| Weight | 34 kg |
| Dimensions (W×D×H) | 400 × 380 × 620 mm |
| Construction | Full stainless-steel frame with integrated fixture alignment points |
| Compliance | GB/T 2679.8, GB/T 6546, GB/T 6548, GB/T 2679.6 |
| Brand | Yuelian / PW |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PW-6602C |
| Power Supply | AC 220 V ±10%, 2 A, 50 Hz |
| Measurement Range | 250–5600 kPa |
| Resolution | 0.1 kPa |
| Indication Error | ±0.5% FS |
| Repeatability | ≤0.5% FS |
| Oil Feed Rate | (170 ± 5) mL/min |
| Clamping Force | ≤1200 kPa (adjustable) |
| Air Compressor Requirement | 0.6–0.7 MPa pressure, 0.02–0.3 m³/min displacement (not included) |
| System Seal Integrity | <10% FS pressure drop within 1 min |
| Display | 7-inch color TFT touch screen with bilingual (Chinese/English) UI |
| Printer | Integrated thermal printer module |
| Communication Interfaces | USB (optional), WAN port (optional) |
| Operating Environment | 10–30 °C ambient temperature, RH < 85% non-condensing |
| Dimensions (L×W×H) | 400 × 350 × 500 mm |
| Weight | ~40 kg |
| Compliance | ISO 2758, GB/T 454 |
| Brand | Yuelian / PW |
|---|---|
| Origin | Guangdong, China |
| Model | PW-6603 MIT |
| Fold Rate Range | 20–200 double folds/min |
| Fold Angle | 135° ± 2° |
| Tension Options | 4.9 N, 9.81 N, 14.7 N |
| Folding Radius | R0.38 mm ± 0.02 mm |
| Clamp Width | 15 ± 0.1 mm |
| Sample Width | 15 mm |
| Sample Length | >140 mm |
| Count Range | 1–99999 cycles |
| Display | 5-inch color touchscreen |
| Output | Thermal printer |
| Power Supply | 220 VAC, 50 Hz |
| Dimensions (Single-Station) | 330 × 290 × 510 mm |
| Weight (Single-Station) | 25 kg |
| Dimensions (5-Station) | 806 × 460 × 490 mm |
| Weight (5-Station) | 100 kg |
| Compliant Standards | ISO 5626, GB/T 2679.5, ASTM D2176, TAPPI T 511, BS ISO 5626, QB/T 1049 |
| Brand | YueLian / PW |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PW-6605 |
| Quotation | Available Upon Request |
| Measurement Range | Torque (0–500) mN·m, Force (0–10,000) mN |
| Accuracy | ±0.1% |
| Span Adjustment | 8 discrete spans (5, 10, 15, 20, 25, 30, 40, 50 mm) |
| Specimen Dimensions | Compatible with both legacy (38 × 70 mm) and updated standard (38 × 80 mm) |
| effective measurement length | 38 × 50 mm |
| Resolution | Force 0.01 mN, Angular 0.1° |
| Self-Calibration | Supported with included calibration weights and tools |
| Angular Velocity Control | 0.5–1000 °/min (adjustable) |
| Bending Duration | Programmable from 5–35 s |
| Bending Angle | Continuously adjustable from 1° to 92° |
| Interface | 5-inch or 7-inch capacitive touchscreen with hierarchical menu navigation |
| Sensor Interchangeability | Tool-free quick-swap sensor module |
| Thermal Printer | Integrated modular thermal printer |
| Overall Dimensions | 350 × 330 × 350 mm (W × D × H) |
| Optional PW-601 Precision Sampling Cutter | Specimen size 80 × 38 mm |
| blade material | Mo-V alloyed chromium steel, wire-EDM cut + CNC precision grinding + triple high-temp quenching |
| Brand | Yuelian / PW |
|---|---|
| Origin | Guangdong, China |
| Model | PW-6606 |
| Measurement Range | A-range 0–8000 mN, B-range 8000–16000 mN |
| Tear Distance | 43 ± 0.5 mm |
| Initial Tear Angle | 27.5 ± 0.5° |
| Tear Radius (Tear Arm Length) | 104 ± 1 mm |
| Sample Dimensions | (63 ± 0.5) mm × (50 ± 2) mm |
| Clamp Face Size | 25 × 15 mm |
| Maximum Clamping Area | 6.48 cm² |
| Clamp Spacing | 2.8 ± 0.3 mm |
| Clamp Torque Ratio | 2.2 : 0.7 |
| Knife Lever Ratio | 14 : 5.5 |
| Minimum Free Swing Count | ≥20 (min), ≥25 (mid), ≥35 (standard) |
| HMI | 5-inch Touchscreen with English/Chinese Interface |
| Compliance | GB/T 455, GB/T 16578.2, QB/T 1050, ISO 1974, TAPPI T414 |
| Brand | Yuelian / PW |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PW-6616 |
| Pricing | Available Upon Request |
| Measurement Range (ΔP = 1 kPa) | A-Type: 0–2500 mL/min, 0.01–42 μm/(Pa·s) |
| Units | μm/(Pa·s), CU, mL/min, s (Gurley) |
| Accuracy | A-Type: ±0.01 μm/(Pa·s), ±0.06 mL/min, ±0.1 s (Gurley) |
| Test Area | 10 cm² |
| Linearity Error | ≤1% |
| Adjustable Test Pressure Differential | 0.05–6 kPa |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Weight | ~30 kg |
| Display | Touchscreen with Bilingual (English/Chinese) UI |
| Compliance | GB/T 458, ISO 5636-2, QB/T 1667, GB/T 22819, GB/T 23227, ISO 2965, YC/T 172, GB/T 12655 |
| Brand | Yuelian / PW |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | PW-6617 |
| Price Range | USD 780–2,350 |
| Sample Size | 25.4 mm × 127 mm |
| Thickness Range | 0.1–5 mm |
| Impact Angle | 90° (standard energy release) |
| Release Mechanism | Fully Automatic Pneumatic Release |
| Measurement Range | 0–1000 J/m² (A-range: 0–500 J/m² |
| B-range | 500–1000 J/m²) |
| Accuracy | ±1 J/m² (A), ±2 J/m² (B) |
| Resolution | 0.001 J/m² |
| Units | J/m² and lbf/in² (interchangeable) |
| Encoder Resolution | 5000-pulse high-precision optical encoder |
| HMI | 7.0-inch capacitive touchscreen (bilingual: English/Chinese) |
| Printer | Integrated thermal printer module |
| Dimensions (W×D×H) | 500 × 400 × 650 mm |
| Weight | ~70 kg |
| Pneumatic Clamping | Yes |
| Compliance Standards | GB/T 26203, GB/T 25203, ASTM T569 pm-00, DIN ISO 16260, TAPPI UM403 |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | PW-6618 |
| Measurement Range | 0–10 N |
| Resolution | 0.01 N |
| Accuracy | ±1% FS |
| Repeatability | ≤1% FS |
| Cup Diameter Range | 30–150 mm |
| Cup Height Range | 15–120 mm |
| Test Speed | 50 ± 2.5 mm/min (adjustable from 1–200 mm/min) |
| Force Travel Distance | 9.5 ± 0.5 mm |
| Dimensions (L×W×H) | 380 × 260 × 290 mm |
| Net Weight | 18 kg |
| Brand | Yuelian / PW |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | PW-6621 |
| Pricing | Upon Request |
| Brand | YueLian / PW |
|---|---|
| Origin | Guangdong, China |
| Model | PW-CHL150-40A-FR6 |
| Temperature Range | −40 °C to +150 °C |
| Temp. Uniformity | ≤2 °C |
| Temp. Stability | ≤±0.5 °C |
| Temp. Accuracy | ±0.2 °C |
| Heating Rate | 3–5 °C/min (avg.) |
| Cooling Rate | 0.7–1 °C/min (avg.) |
| Folding Angle | 22.5° |
| Folding Speed | 0–100 ±3 cpm |
| Sample Size | 70 × 45 mm |
| Test Stations | 6 parallel |
| Internal Chamber Dimensions | 500 × 500 × 600 mm |
| Net Weight | 310 kg |
| Power Supply | AC 220 V |
| Brand | Yuelian / PW |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PW-Q63 |
| Quotation | Available Upon Request |
| Sampling Dimensions | 50 × 63 mm |
| Thickness Range | 0.1–1.0 mm |
| Overall Dimensions | 320 × 115 × 110 mm |
| Weight | ~9 kg |
| Blade Material | Chromium steel alloy with molybdenum and vanadium |
| Sampling Accuracy | ≤ ±0.1 mm |
| Compliance | TAPPI T414, QB/T 1050, GB/T 455–2002 (sampling specifications) |
| Brand | Yuelian |
|---|---|
| Model | PW-TCK-T03 |
| Measurement Range | 0–10.0 mm |
| Accuracy | ±0.002 mm |
| Resolution | 0.001 mm |
| Parallelism Between Measuring Surfaces | ≤0.002 mm |
| Contact Area | 200 ± 5 mm² |
| Platen Boss Diameter | 16 ± 0.15 mm |
| Probe Descent Speed | 0.1–15.0 mm/s (adjustable) |
| Dwell Time | 0.1–5 s (adjustable) |
| Contact Pressure | 100 ± 2 kPa (GB/T), 50 ± 2 kPa (TAPPI) |
| Display | 5-inch color touchscreen (English/Chinese UI) |
| Output | Thermal printer + USB-B interface |
| Power Supply | 220 VAC, 50 Hz |
| Dimensions | 260 × 350 × 430 mm |
| Weight | ~45 kg |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | S71CR |
| Price Range | USD 1,400 – 7,200 |
| Load Capacity Options | 10 N to 5 kN (dual-range configurable) |
| Stroke | 450 mm |
| Speed Range | 0.01–500 mm/min |
| Force Resolution | 1/500,000 full scale |
| Force Accuracy | Better than ±0.5% FS |
| Data Acquisition Rate | 50 Hz |
| Compliance | ASTM D3786, ISO 13934-1 (adapted for compressive resistivity), GB/T 2423.17 (salt mist compatibility support) |
| Brand | Yuelian |
|---|---|
| Model | YL-8809A |
| Application | Manual sampling of pressure-sensitive adhesive tapes, protective films, and release liners |
| Sample Thickness Range | 0.1–1.5 mm (foam tapes), 0.1–0.25 mm (PET protective films), 0.1–0.6 mm (fabric-backed tapes) |
| Adjustable Sample Width | 15 mm and 24 mm |
| Fixed Sample Length | 300 mm |
| Output per Cycle | 6 specimens |
| Dimensional Accuracy | ±0.1 mm |
| Overall Dimensions | 420 × 330 × 145 mm |
| Weight | 8 kg |