Particle/Powder Analysis Instruments
Filter
Showing 121–150 of 340 results
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | BI-DNDC |
| Pricing | Available Upon Request |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | PFT |
| Instrument Type | Powder Flow Tester |
| Measurable Parameters | Cohesive Strength, Internal Friction Angle, Wall Friction Angle |
| Vertical Load Range | 7 kg (±0.6% FSR) |
| Axial Speed | 0.1 mm/s (adjustable up to 1 mm/s) |
| Displacement Accuracy | ±0.3 mm |
| Torque Range | ±7.0 N·m (±1.2% FSR) |
| Hopper Rotation Speed | 1–5 rpm |
| Temperature Sensing | –20°C to 120°C |
| Humidity Sensing | 10–95% RH (±5% accuracy) |
| Dimensions (W×D×H) | 36.2 × 39.7 × 67.6 cm |
| Weight | 34 kg |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PFT |
| Price Range | USD 65,000 – 105,000 |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ACOS |
| Pricing | Upon Request |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | In-Line Laser Particle Size Analyzer |
| Measurement Range | Particle Size: 0.6 nm – 3 µm |
| Dynamic Concentration Range | 0.1 ppm – 40% (w/v) |
| Repeatability | Configurable per application protocol |
| Measurement Duration | User-Defined |
| Brand | Brookhaven Instruments |
|---|---|
| Origin | USA |
| Model | BI-200SM |
| Particle Size Range | 1 nm – 6 µm |
| Molecular Weight Range | 500 – 10⁹ Da |
| Hydrodynamic Size Range | 10 – 1000 nm |
| Scattering Angle Range | 8°–162°, ±0.01° |
| Temperature Control Range | −20 °C to 80 °C (optional −20 °C to 150 °C), ±0.1 °C |
| Laser Wavelength Options | 632.8 nm, 532 nm, 514.5 nm, 488 nm |
| Aperture Wheel Sizes | 100 µm, 200 µm, 400 µm, 1 mm, 2 mm, 3 mm |
| Correlator | TurboCorr digital photon correlator |
| Brand | Brookhaven Instruments |
|---|---|
| Origin | USA |
| Model | BI-DCP / BI-XDC |
| Measurement Principle | Centrifugal & Gravitational Sedimentation |
| Repeatability | 1% |
| Accuracy | ±2% |
| Particle Size Range (BI-DCP) | 0.01–45 µm |
| Particle Size Range (BI-XDC) | 0.01–100 µm |
| Detection Method | Visible Light (BI-DCP) / X-ray (BI-XDC) |
| Sample Introduction | Layered (LIST mode) or Homogeneous (HOST mode) |
| Rotational Speed Range | 500–15,000 rpm (BI-DCP) |
| Speed Stability | ±0.01% |
| Disk Material | Standard PMMA or Corrosion-Resistant Alternative |
| Data Storage | Built-in extinction curve database (BI-DCP) |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Model | BI-MwA |
| Molecular Weight Range | 500–10⁹ Da |
| Hydrodynamic Size Range | 10–1000 nm |
| Scattering Volume | 20 nL |
| Sample Cell Volume | 100 µL |
| Maximum Back Pressure | 3.5 MPa (500 psi) |
| Detection Angles | 8 fixed angles (35°, 50°, 75°, 90°, 105°, 130°, 145° + reference angle) |
| Detector | High-Sensitivity CCD |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | BI-ZTU |
| Pricing | Available Upon Request |
| pH Range | 2–12 |
| Sample Cell Option | Flow-Through Cell |
| Pump Tubing | 1 mm (0.04") ID, Compatible with Teflon®, PEEK®, and EPDM® |
| Included Accessories | Integrated pH Electrode + Four 100 mL Reagent Bottles |
| Drive System | Four Independent Peristaltic Pumps |
| Brand | Brookhaven Instruments |
|---|---|
| Origin | USA |
| Model | BioDLS |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Online Laser Particle Size Analyzer |
| Particle Size Range | 0.5 nm – 3 µm (sample-dependent) |
| Molecular Weight Range | 4 × 10² – 2 × 10⁷ Da (sample-dependent) |
| Concentration Range | 0.1 – 100 mg/mL (sample-dependent) |
| Sample Volume | 2 µL |
| Throughput | Up to 768 samples per run (2 × 384-well plates) |
| Temperature Control | Sample cell: 5–90 °C |
| Storage plate | Ambient to 4 °C |
| Laser Source | 35 mW, 635 nm solid-state laser (optional 30 mW, 850 nm) |
| Scattering Angle | 90° |
| Detector | Avalanche Photodiode (APD) |
| Correlator | 522 physical channels, 10¹⁰ linear channels, dynamic sampling/delay range: 25 ns – 1310 s |
| Interface | USB 2.0 & 1.1 |
| Software | Windows XP/Vista compatible |
| Dimensions (w/d/h) | 300 × 510 × 630 mm (28 kg, no storage cooler) |
| Operating Environment | 10–75 °C, 0–95% RH (non-condensing) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FOQELS |
| Pricing | Upon Request |
| Brand | Brookhaven Instruments |
|---|---|
| Origin | USA |
| Model | 173Plus |
| Particle Size Range | 0.3 nm – 10 μm |
| Concentration Range | 0.1 ppm – 40% w/v |
| Typical Accuracy | ±1% |
| Sample Volume | 10–3000 μL (with 10 μL & 50 μL micro-cells) |
| Molecular Weight Range | 342 – 2×10⁷ Da |
| Temperature Control | −5°C to 120°C (±0.1°C stability) |
| pH Range | 1–14 |
| Laser Source | 40 mW solid-state laser (optional 5 mW He-Ne) |
| Detector | Avalanche Photodiode (APD) |
| Correlator | 4×10¹¹ linear channels, dual-channel cross-correlation support |
| Scattering Angles | 13°, 90°, and 173° (motorized, software-selectable) |
| Optional Modules | Micro-rheology, Zeta Potential, In-line Process Monitoring, Automated Titrator, Dielectric Constant Meter, Viscometer, 21 CFR Part 11 Compliant Software |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Model | NanoBrook 173Plus |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Particle Size Analyzer |
| Measurement Range | 0.3 nm – 10 µm |
| Repeatability | ±1% |
| Measurement Time | 1–2 min |
| Scattering Angles | 15°, 90°, 173° |
| Concentration Range | 0.1 ppm – 40% w/v |
| Temperature Control | −5 °C to 120 °C (±0.1 °C) |
| Laser Source | 40 mW Solid-State Laser (optional 5 mW He-Ne) |
| Detector | APD |
| Correlator | 4×10¹¹ Linear Channels, Dual-Channel Cross-Correlation Support |
| Sample Volume | 0.01–3 mL (with optional 50 µL and 10 µL micro-cells) |
| Molecular Weight Range | 342–2×10⁷ Da |
| pH Range | 1–14 |
| Software Compliance | 21 CFR Part 11 Ready |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Model | NanoBrook 90Plus |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.3 nm – 15 µm |
| Repeatability | ±1% |
| Measurement Time | 1–2 min |
| Temperature Control Range | −5 °C to 110 °C (±0.1 °C) |
| Sample Volume | 10–3000 µL |
| Laser Source | 40 mW Solid-State Laser |
| Detector | PMT or APD |
| Correlator | 4×10¹¹ Linear Channels, 4-Channel Input, Dual Cross-Correlation Support |
| Scattering Angles | 15° and 90° Options |
| Zeta Potential Option | Available |
| Software Compliance | 21 CFR Part 11 Audit Trail Mode |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NanoBrook 90plus PALS |
| Dispersion Method | Wet Dispersion |
| Particle Size Range | 0.3 nm – 15 µm |
| Repeatability | ±1% |
| Measurement Time | 1–2 min |
| Zeta Potential Measurement Principle | Phase Analysis Light Scattering (PALS) |
| Temperature Control Range | −5 °C to 110 °C (±0.1 °C) |
| Scattering Angles | 15° and 90° |
| Laser Source | 40 mW Solid-State Laser (He-Ne Optional) |
| Detector | APD or PMT |
| Correlator | 4×10¹¹ linear channels, 4-channel input, dual cross-correlation support |
| Electrophoretic Mobility Range | 10⁻¹¹ – 10⁻⁷ m²/V·s |
| Conductivity Range | 0 – 30 S/m |
| pH Range | 1 – 14 |
| Sample Volume | 10 µL – 3 mL (with 10 µL & 50 µL micro-cells) |
| Molecular Weight Range | 342 – 2×10⁷ Da |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NanoBrook 90Plus Zeta |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Size Range | 0.3 nm – 15 µm |
| Repeatability | ±1% |
| Measurement Time | 1–2 min |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Model | NanoBrook Omni |
| Dispersion Method | Wet Dispersion |
| Particle Size Range | 0.3 nm – 15 µm |
| Repeatability | <1% |
| Measurement Time | 1–2 min |
| Scattering Angles | 13°, 90°, 173° |
| Zeta Potential Technique | Hardware-Based Phase Analysis Light Scattering (PALS) |
| Concentration Range | 0.1 ppm – 40% w/v |
| Temperature Control | −5 °C to 120 °C (±0.1 °C) |
| Sample Volume | 10 µL – 3 mL |
| Laser Source | 40 mW Solid-State Laser (optional 5 mW He-Ne) |
| Detector | APD |
| Correlator | 4×10¹¹ linear channels, 4-channel input, dual cross-correlation support |
| Electrophoretic Mobility Range | 10⁻¹¹ – 10⁻⁷ m²/V·s |
| Conductivity Range | 0 – 30 S/m |
| pH Range | 1 – 14 |
| Molecular Weight Range | 342 – 2×10⁷ Da |
| Optional Compliance | 21 CFR Part 11 Software Module |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Model | NanoBrook ZetaPALS |
| pH Range | 1–14 |
| Temperature Range | −5 to 110 °C |
| pH Resolution | 0.1 |
| Temperature Resolution | 0.1 °C |
| Accuracy | ±1% |
| Repeatability | ±1% |
| Electrophoretic Mobility Range | 1×10⁻¹¹ to 1×10⁻⁷ m²/V·s |
| Particle Size Range (optional DLS) | 0.001–100 µm |
| Sample Volume | 0.018–1.5 mL |
| Conductivity Range | 0–30 S/m |
| Electric Field Strength | 0–3.2 kV/m |
| Laser Source | 40 mW solid-state laser (wavelength & power customizable) |
| Detector | PMT or APD |
| Electrode Material | Palladium (corrosion-resistant open-cell capillary electrode optional) |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Model | NanoBrook ZetaPlus |
| Zeta Potential Range | ±500 mV |
| pH Range | 1–14 |
| Temperature Range | −5 to 110 °C |
| pH Resolution | 0.1 |
| Temperature Resolution | 0.1 °C |
| Accuracy | ±1% |
| Repeatability | ±1% |
| Particle Size Range (Electrophoretic Mode) | 0.001–100 µm |
| Sample Volume | 0.18–1.5 mL |
| Conductivity Range | 0–20 S/m |
| Electrophoretic Mobility Range | 1×10⁻¹⁰ to 1×10⁻⁷ m²/V·s |
| Electric Field Strength | 0–3.2 kV/m |
| Electrode Material | Palladium (corrosion-resistant, open-cell design) |
| Laser Source | 35 mW solid-state laser (optional 5 mW He–Ne) |
| Detector | PMT or APD |
| Automated Trend Analysis | time-, temperature-, pH-, and conductivity-dependent |
| Brand | Brookhaven Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NanoDLS |
| Dispersion Method | Wet & Dry Dispersion |
| Instrument Type | Online Laser Particle Size Analyzer |
| Measurement Range | 0.5 nm – 3 µm (refractive index dependent) |
| Repeatability | ≤1% (typical) |
| Measurement Time | <10 s per acquisition (configurable) |
| Sample Volume | 2.5 µL |
| Max Operating Pressure | 400 bar (5,880 psi) |
| Concentration Range | 0.1–100 mg/mL |
| Temperature Control Range | 25–80 °C |
| Laser Source | 35 mW, 638 nm solid-state laser |
| Detector | Avalanche Photodiode (APD) |
| Scattering Angle | 90° |
| Interface | USB 2.0 & 1.1 |
| Data Output | Hydrodynamic diameter distribution (intensity-, number-, and volume-weighted), Gaussian & multimodal fitting, real-time aggregation kinetics plots |
| Operation Mode | Auto-sampling or manual injection |
| Optional Integration | BI-MwA multi-angle static light scattering module for SEC-MALS coupling |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | WFA-840D / WFA-860D / WFA-840E |
| Stirring Positions | 4 / 6 / 4 |
| Speed Range (rpm) | 10–300 / 10–300 / 0–200 |
| Speed Resolution | 1 / 1 / 1 rpm |
| Speed Accuracy | ±1 / ±1 / — rpm |
| Display | LED / LED / Scale + Knob |
| Backlight | Yes / Yes / Yes |
| Timer Range | 0–99 h or 0–999 min / OFF or 0–99 h or 0–999 min / 0–30 min or Continuous |
| Power Consumption | 11 W / 19 W / 6 W |
| Brand | Colloidal Dynamics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ZetaProbe |
| Price Range | USD 68,000–136,000 |
| Zeta Potential Range | ±300 mV |
| pH Range | 1–13 |
| Operating Temperature Range | 5–50 °C |
| pH Resolution | 0.1 |
| Temperature Resolution | 0.1 °C |
| Accuracy | ±1% of reading (typical) |
| Repeatability | ±0.01 mV (standard deviation over 10 measurements) |
| Brand | Colloidal Dynamics |
|---|---|
| Origin | USA |
| Model | ZetaProbe |
| Sample Concentration Range | 0.5–60 vol% |
| Zeta Potential Measurement Range | ±500 mV (typical) |
| Particle Size Range for Zeta Measurement | 1 nm – 50 µm |
| pH Range | 0.5–13.5 |
| Conductivity Range | 0–5 S/m |
| Sample Volume | 20–250 mL |
| Measurement Time | <30 s per reading |
| Titration Resolution | 1 µL |
| IEP Detection | Automated via Multi-Point Titration |
| Data Export Format | Native CSV and Excel-Compatible .xls |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VASCO |
| Price Range | USD 26,000–39,000 (FOB) |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.01–3500 µm |
| Repeatability | <5% |
| Measurement Time | 30 seconds |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DC24000 UHR |
| Price Range | USD 110,000–138,000 (FOB) |
| Particle Size Range | 5 nm – 75 µm |
| Size Measurement Repeatability | ±0.5% RSD |
| Operating Temperature | Ambient (15–30 °C) |
| Light Source Wavelength | 405 nm (violet diode laser) |
| Measurement Principle | High-Speed Centrifugal Sedimentation (HSCS) |
| Sample Mass Range | 0–10 ng |
| Sample Concentration | Matrix-independent (no dilution requirement) |
| Zeta Potential Capability | Not integrated |
| Typical Analysis Time | 1–3 minutes per run |
| Molecular Weight Determination | Not supported |
| Brand | DT Instruments |
|---|---|
| Origin | USA |
| Model | DT-100 / DT-110 |
| Measurement Principle | Ultrasonic Attenuation Spectroscopy (UAS) |
| Particle Size Range | 5 nm – 1000 µm |
| Sample Concentration Range | 0.1–50% v/v (undiluted) |
| Operating Frequency Range | 1–100 MHz |
| Minimum Sample Volume (DT-110) | < 5 mL |
| Dispersion Media Compatibility | Aqueous, polar, and non-polar liquids |
| Data Management | Microsoft Access-based database |
| Calibration-Free Operation | Yes |
| Adjustable Transducer Gap | Yes |
| Compliance Context | Supports GLP/GMP-aligned workflows |
| Brand | DT Instruments |
|---|---|
| Origin | USA |
| Model | DT-300 / DT-310 |
| Measurement Principle | Electroacoustic (Colloid Vibration Current, CVI) |
| Zeta Potential Range | Unlimited (down to ±0.1 mV) |
| Sample Concentration | 0.1–50% v/v (no dilution required) |
| Minimum Sample Volume | 2 mL |
| Measurable Parameters | Zeta potential, dynamic electrophoretic mobility, Debye length, particle size distribution (via optional ultrasound attenuation spectroscopy), rheological properties (viscoelastic moduli), solid content, porosity |
| Software Platform | Microsoft Access-based database with audit trail capability |
| Optional Module | Automated titration system (DT-310 only) |
| Compliance Context | Designed for GLP/GMP-aligned laboratories |
| Brand | DT (USA) |
|---|---|
| Origin | USA |
| Model | RUFUTO-871 |
| Measurement Range | 1–20 and 1–200 (dimensionless) |
| Accuracy | ±2% |
| Calibration | With deionized water or reference liquids of known permittivity |
| Probe Type | Open-ended coaxial probe |
| Sample Compatibility | Aqueous solutions, polar and non-polar organic solvents, solvent mixtures |
| Brand | DT (USA) |
|---|---|
| Origin | USA |
| Model | DT-1202 |
| Particle Size Range | 5 nm – 1000 µm |
| Zeta Potential Measurement Range | Unlimited (±0.1 mV accuracy) |
| Concentration Range | 0.1–50 vol% |
| pH Range | 0.5–13.5 |
| Conductivity Range | 0.0001–10 S/m |
| Temperature Range | <50 °C |
| Max. Viscosity | 20,000 cP |
| Frequency Range | 1–100 MHz |
| Minimum Sample Volume | 2 mL |
| Titration Resolution | 0.1 µL |
| Simultaneous Measurement | Particle Size + Zeta Potential in One Cell |
| Optional Modules | Rheology, pH, Conductivity, Temperature, Auto-Titration, Non-Aqueous Systems |
| Brand | DT Instruments |
|---|---|
| Origin | USA |
| Model | DT-330 |
| Measurement Principle | Electroacoustics (Colloid Vibration Current, CVI) & Electrophoretic Acoustics (ESA) |
| Sample Concentration Range | 0.1–50 vol% (no dilution required) |
| Minimum Sample Volume | 2 mL |
| Zeta Potential Range | No theoretical lower limit |
| Compatible Solvents | Aqueous, polar, and non-polar media |
| Porosity Measurement | Yes (via high-frequency conductivity probe) |
| Surface Zeta Potential on Porous Solids | Yes |
| Output Parameters | Dynamic electrophoretic mobility, Debye length, surface charge density, solid content, rheological properties |
| Compliance Context | Designed for GLP/GMP-aligned labs |
| Brand | DT (USA) |
|---|---|
| Origin | USA |
| Model | DT-600 |
| Measurement Principle | Ultrasonic Spectroscopy (1–100 MHz) |
| Sample Concentration Range | 0.1–50 vol% (no dilution required) |
| Viscosity Range | 0.5–100 cP (±3% accuracy) |
| Longitudinal Modulus (G*) Measurement | 1–100 MHz |
| Solvent Compatibility | Aqueous, polar, and non-polar media |
| Zeta Potential & Particle Size | Direct measurement in concentrated dispersions |
| Isoelectric Point (IEP) Determination | Model-independent, no Debye-Hückel or Smoluchowski approximation required |
| Titration Function | Integrated automated potentiometric titration module |
| Data Management | Microsoft Access-based local database with audit-ready export |