Particle/Powder Analysis Instruments
Filter
Showing 211–240 of 340 results
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | SediGraph III Plus |
| Measurement Principle | X-ray sedimentation |
| Measurement Range | 0.1–300 µm |
| Repeatability | < 1% RSD |
| Accuracy | < 1% error vs. NIST-traceable standards |
| Analysis Time | 3–15 minutes per sample |
| Sample Volume | 50 mL dispersion |
| Compliance | ISO 13317-3, ASTM B761, ASTM C28 (Advanced Ceramics) |
| Automation | Unattended analysis of up to 18 samples |
| Optional Integration | MasterTech Auto-sampler for process monitoring and cloud data export |
| Brand | Microtrac |
|---|---|
| Origin | Germany |
| Model | AEROTRAC II |
| Dispersion Method | Dry Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.5–2,000 µm |
| Repeatability | ≤1% |
| Measurement Time | 10–15 seconds |
| Optical Principle | Static Laser Diffraction with Full-Range Mie Theory Processing |
| Laser Source | Semiconductor Laser |
| Auto-Focusing | Yes |
| Trigger Mode | Automatic Pulse Detection |
| Software Platform | Windows-Compatible Analysis Suite |
| Optional Accessories | PD-10S Dry Spray Module, SC-13 Wet Dispersion Unit, MB-600 Motorized Translation Stage |
| Compliance | Designed for ASTM E799, ISO 13320, and USP <429> alignment |
| Brand | Microtrac |
|---|---|
| Origin | Germany |
| Model | NANOTRAC FLEX |
| Particle Size Range | 0.3 nm – 10 µm |
| Size Reproducibility | ≤1% RSD |
| Temperature Control Range | 10–35 °C |
| Temperature Stability | ±0.1 °C (with optional Peltier module) |
| Detection Method | Dynamic Light Backscattering (180° geometry) with full-range Mie theory-based data inversion |
| Sample Volume | as low as 2 µL |
| Sample Concentration Limit | up to 40 vol.% (non-dilutive measurement) |
| Zeta Potential Range | –3000 mV to +3000 mV (when coupled with STABINO ZETA) |
| Molecular Weight Estimation | via hydrodynamic diameter and Debye plot correlation |
| Optical Architecture | Fixed-focal-length fiber-optic probe with laser amplification detection |
| Data Processing Algorithm | Frequency Power Spectrum (FPS), not conventional Photon Correlation Spectroscopy (PCS) |
| Brand | Microtrac |
|---|---|
| Origin | Germany |
| Model | NANOTRAC WAVE II |
| Zeta Potential Range | ±200 mV |
| Temperature Operating Range | 0–90 °C (programmable ramp) |
| pH Resolution | 0.1 |
| Temperature Accuracy | ±0.1 °C |
| Particle Size Range | 0.3 nm – 10 µm |
| Concentration Range | 100 ppb – 40 % w/v |
| Detection Angle | 180° (backscatter) |
| Repeatability | ≤1% |
| Theoretical Basis | Full-range Mie theory with non-spherical particle correction factor |
| Compliance | ISO 13321, ISO 13099-2:2012, ISO 22412:2008 |
| Software Compliance | FDA 21 CFR Part 11 (electronic signatures, audit trail, user access control) |
| Brand | Microtrac |
|---|---|
| Origin | Germany |
| Model | S3500 Series |
| Dispersion Method | Dry & Wet |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range (Laser Diffraction) | 0.01–2,800 µm |
| Image Analysis Range | 0.75–2,000 µm |
| Repeatability | <1% |
| Measurement Time (Laser Diffraction) | 10–30 s |
| Measurement Time (Dynamic Image Analysis) | ~60 s |
| Light Source | Patented Triple-Solid-State Laser (Laser Diffraction) / High-Intensity Stroboscopic LED (Image Analysis) |
| Detection Angle Range | 0.02°–163° |
| Detector Array | 151 logarithmically spaced silicon photodiodes |
| Image Sensor | 5 MP, 2456 × 2058 resolution, 15 fps (optional high-speed camera available) |
| Software Compliance | Fully compliant with FDA 21 CFR Part 11 (audit trail, electronic signatures, data integrity controls) |
| Brand | Microtrac |
|---|---|
| Origin | Germany |
| Model | S3500SI |
| Measurement Principle | Laser Diffraction & Dynamic Image Analysis |
| Size Range (Laser Diffraction) | 0.01–2800 µm |
| Size Range (Dynamic Imaging) | 0.75–2000 µm |
| Repeatability | ±0.1% |
| Light Source | Triple Solid-State Red Lasers (635 nm) + High-Intensity Stroboscopic LED |
| Detector Array | 151 Logarithmically Spaced Silicon Photodiodes, Acceptance Angle: 0.02°–163° |
| Imaging Sensor | 5 MP CMOS, Resolution: 2456 × 2058 |
| Analysis Time (LD) | 10–999 s |
| Analysis Time (Imaging) | 60 s per field |
| Software Compliance | FDA 21 CFR Part 11, Audit Trail, Electronic Signatures, Data Integrity Controls |
| Brand | Microtrac |
|---|---|
| Origin | Germany |
| Model | STABINO ZETA |
| Zeta Potential Range | ±3000 mV |
| pH Range | 1–14 |
| Operating Temperature Range | 0–90 °C |
| pH Resolution | ±0.1 |
| Temperature Resolution | ±0.1 |
| Measurement Principle | 180° Dynamic Light Scattering and Heterodyne Doppler Electrophoresis |
| Repeatability | ≤1% error |
| Brand | Microtrac |
|---|---|
| Origin | Germany |
| Model | SYNC |
| Dispersion Method | Dry & Wet |
| Instrument Type | Laboratory Laser Diffraction + Dynamic Image Analysis Hybrid System |
| Measurement Range | 0.01–4000 µm |
| Repeatability | <1% |
| Measurement Time | 10–30 s |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PQ001 |
| Pricing | Available Upon Request |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PQ001 |
| Pricing | Available Upon Request |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PQ001-Powder |
| Pricing | Available Upon Request |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | PQ001-NMR |
| Measurement Scope | In-situ wettability analysis of particle suspensions in native liquid media |
| Brand | Occhio |
|---|---|
| Origin | Belgium |
| Model | 500nano HR |
| Measurement Principle | Static image analysis with high-resolution CMOS imaging and collimated blue backlighting |
| Measurement Mode | Dry dispersion (integrated vacuum dispersion system) and reflective mode |
| Particle Size Range (dry) | 0.4–2000 µm |
| Pixel Resolution | 0.38–4.7 µm/pixel |
| Camera | 6.6 MP or 10 MP progressive-scan industrial CMOS |
| Optical System | Zoom telecentric lens |
| Light Source | 440 nm collimated blue LED |
| Field of View | 836 × 1140 µm @ 0.38 µm/pixel to 10266 × 1400 µm @ 4.7 µm/pixel |
| Software | Callisto 2D |
| Compliance Options | IQ/OQ/PQ validation support |
| Dimensions (W×D×H) | 540 × 540 × 720 mm (standard) |
| Weight | 38.5 kg / 43.5 kg |
| Brand | Occhio |
|---|---|
| Origin | Belgium |
| Model | SIEVECAL |
| Application | Automated optical calibration and metrological analysis of test sieves per ASTM E11, ISO 3310-1, and DIN EN ISO 3310-1 |
| Imaging Resolution | 1.2 µm (pixel-limited) |
| Sieve Diameter Support | 200–300 mm (8–12 inch) |
| Aperture Size Range | 20 µm – 12.5 mm |
| Measurement Parameters | Feret X/Y diameters, maximum inscribed circle diameter, wire thickness (X/Y), aperture area, blockage ratio, statistical distribution (mean, min, max, σ) |
| Compliance Standards | ASTM E11-13, ISO 3310-1:2016, DIN EN ISO 3310-1 |
| Analysis Time | ≤120 s per sieve |
| Optical System | Collimated 450 nm blue LED backlight + telecentric zoom lens + USB3 monochrome camera (1.3 MP) |
| Automation Level | Fully motorized XY translation + 360° continuous rotation stage |
| Software | Occhio SIEVECAL Suite with audit-trail-capable reporting, GLP-compliant data storage, and CFR 21 Part 11–ready configuration options |
| Brand | Endecotts |
|---|---|
| Origin | United Kingdom |
| Model | OCTAGON DIGITAL 2000 |
| Base Height | 210 mm |
| Diameter | 410 mm |
| Sieve Diameter | 200 mm (8 in) |
| Sieve Capacity | 8 full-height or 16 half-height sieves |
| Compliance | EC Machinery Directive, BS 410:2019 compliant test sieve manufacturer |
| Brand | Octopus |
|---|---|
| Origin | Germany |
| Model | SAMILLA FIM LO |
| Application Field | Pharmaceutical |
| Instrument Type | Dynamic |
| Measurement Range | 200 nm – 2 mm |
| Camera Options | 12 MP monochrome or color camera |
| Sample Dispersion Method | Wet dispersion |
| Image Resolution | 12 MP |
| Measured Parameters | Full particle size and shape metrics (e.g., area, perimeter, circularity, aspect ratio, convexity, solidity, Feret diameters, intensity, texture) |
| Module Architecture | HiRes-FIM (High-Resolution Flow Imaging Microscopy), Light Obscuration (LO), Pump (MACRO/MICRO1/MICRO2/HYBRID), Auto-Clean |
| Brand | Octopus |
|---|---|
| Origin | Germany |
| Model | SAMILLA-FIM |
| Application Field | Pharmaceutical |
| Instrument Type | Dynamic |
| Measurement Range | 200 nm – 2 mm |
| Camera Options | 12 MP monochrome or color camera |
| Dispersion Method | Wet dispersion |
| Image Resolution | 12 MP |
| Measurement Parameters | Full particle size and shape characterization (equivalent spherical diameter, aspect ratio, circularity, convexity, solidity, elongation, roundness, etc.) |
| Brand | OFITE |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 365-10 |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.34–500 µm |
| Data Storage | 128 MB Flash Memory (≥40,000 samples) |
| Battery Life | Up to 6 hours |
| Dimensions (H×D×W) | 17.7 × 29 × 44.3 cm |
| Weight | 7.5 kg |
| Ultrasonic Probe | 25 W, 40 kHz |
| Compliance | ISO 13320-1 |
| Brand | Otsuka Electronics |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | ELSZ-neo SE |
| Price | Upon Request |
| Particle Size Range | 0.6 nm – 10 µm |
| Temperature Control Range | 0–90 °C |
| Particle Sizing Method | Dynamic Light Scattering (Photon Correlation Spectroscopy) |
| Sample Concentration Range | Zeta Potential: 0.001–40% w/v |
| Particle Size | 0.00001% (0.1 ppm) – 40% w/v*¹ |
| Zeta Potential Measurement Range | No practical upper limit |
| Zeta Potential Principle | Electrophoretic Light Scattering (Laser Doppler Velocimetry) |
| Particle Size Principle | Dynamic Light Scattering (DLS) |
| Optical Configuration | Heterodyne for Zeta Potential |
| Light Source | Narrow-band Diode Laser |
| Detector | High-Sensitivity APD |
| Standard Cell | Flow-through Cell for Simultaneous Zeta & Size |
| Optional Accessories | Fluorescence Cut-off Filter, Flat-sample Electrode Cell for High-Salt Surface Zeta, Temperature Gradient Module |
| Power Supply | 100 V ±10%, 250 VA |
| Dimensions (W×D×H) | 330 × 565 × 245 mm |
| Weight | 22 kg |
| Brand | Palas |
|---|---|
| Origin | Germany |
| Model | U-SMPS 1700 |
| Particle Size Range | 2–400 nm |
| Particle Concentration Range | 0–10⁸ particles/cm³ |
| Classification Channels | Up to 128 (logarithmic or linear stepping) |
| Measurement Time per Scan | As low as 30 s |
| Compliance | ISO 15900 (Differential Mobility Analysis), EN 13274-6, ASTM F3233 |
| Interface Options | USB, LAN, WLAN, RS-232/485 |
| Display | 7-inch capacitive touchscreen GUI |
| Data Logging | Integrated high-resolution time-stamped recorder |
| Interoperability | Compatible with third-party DMAs, CPCs (e.g., TSI, Grimm), and electrometers |
| Brand | PAMAS |
|---|---|
| Origin | Germany |
| Model | S40 |
| Instrument Type | Optical Particle Counter |
| Measurement Principle | Light Obscuration (LO) |
| Particle Size Channels | 8 user-configurable thresholds |
| Compliance Standards | ISO 4406:1987 / ISO 4406:1999 / SAE AS4059D / NAS1638 |
| Power Supply | 90–230 V AC, 50 Hz |
| Weight | ~9 kg |
| Dimensions | 300 × 140 × 300 mm |
| Display | Backlit touchscreen LCD |
| Data Interface | RS-232C (ASCII 8-bit) |
| Internal Storage | 500 measurement records |
| Sampling Pressure Range | 0–420 bar |
| Viscosity Limit | ≤200 cSt (unpressurized), ≤350 cSt (pressurized), ≤1000 cSt (lubricating oil systems) |
| Brand | Particle Metrix |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ZetaView® Evolution |
| Zeta Potential Range | ±500 mV |
| pH Range | 1–13 |
| Operating Temperature Range | 5°C to 55°C |
| pH Resolution | 1–13 |
| Temperature Resolution | 0.1°C |
| Size Accuracy | ±5 nm |
| Size Repeatability | ±2 nm |
| Brand | POWEREACH |
|---|---|
| Model | JCJ04 |
| Type | Gravitational Sedimentation Particle Size Analyzer |
| Origin | Shanghai, China |
| Measurement Principle | Gravitational sedimentation (Stokes’ law-based) |
| Particle Size Range | 1–60 µm |
| Maximum Sample Mass Capacity | 0–100 g (selectable) |
| Sensitivity | 0.1 mg |
| Data Acquisition Interval | 0.5 s |
| Sample Vessel | 500 mL calibrated glass cylinder |
| Calibration Weights | 0.5 g, 10 g, 50 g, 100 g |
| Data Output | Real-time sedimentation curve, D10/D50/D90, mean diameter, particle size distribution histogram, cumulative distribution, error estimation |
| Software Functions | Auto-zero, tare, self-calibration, alarm threshold setting, curve storage/retrieval, statistical analysis, report generation & printing |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | POWEREACH (Shanghai Zhongchen Digital Technology Equipment Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | JN01A |
| Zeta Potential Measurement Principle | Mass-Exchange Electrophoresis |
| Sample Concentration Range | High-concentration dispersions (undiluted, slurry-state) |
| pH Range | Not specified |
| Compliance | Designed for ASTM D4187, ISO 13099-2, and GLP-compliant workflows requiring raw-state dispersion analysis |
| Interface | RS232 (COM port) + USB |
| Software | JN01.exe (Windows XP / 32-bit Windows 7 compatible) |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JS94 |
| Measurement Principle | Microelectrophoresis (Video-Based Particle Tracking) |
| Compliance | GB/T 32668–2016 (National Standard for Colloidal Particle Zeta Potential Analysis – Electrophoretic Method) |
| Power Consumption | <150 W |
| Input Voltage | 220 V, 50 Hz |
| Operating Temperature Range | Ambient to 35 °C |
| Zeta Potential Accuracy | Systematic error ≤5% |
| pH Range | 1.6–13.0 (typical operational range: 2.0–12.0) |
| Sample Volume per Test | 0.5 mL |
| Optical Magnification | Up to 1200× |
| Imaging System | USB Digital CCD with Customized Micrometer Grid Calibration |
| Electrode Configuration | Integrated Ag, Pt, and Ti/POM electrodes in open-cell electrophoresis chamber |
| Voltage Control | Adjustable DC bias with polarity reversal (0.30–1.20 s interval) |
| Temperature Compensation | Real-time thermistor-based ambient temperature sampling |
| Software Platform | Unified cross-model analysis suite with GLP-compliant data logging and audit trail capability |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JS94H-3H10X |
| Zeta Potential Range | ±200 mV (typical, dependent on sample conductivity) |
| pH Range | 1.6–13.0 (optimal 2.0–12.0) |
| Operating Temperature | 20–35 °C |
| Temperature Resolution | 0.1 °C |
| Optical Resolution | 3 pixels/µm |
| System Accuracy | ±5% relative error (per GB/T 32668-2016 validation protocol) |
| Particle Size Applicability | 0.5–20 µm (aqueous dispersions) |
| Power Consumption | <150 W |
| Input Voltage | 220 V AC, 50 Hz |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JS94H2-3H10X |
| Zeta Potential Range | ±200 mV (typical, dependent on sample conductivity) |
| pH Range | 1.6–13.0 (optimal 2.0–12.0) |
| Operating Temperature | 20–35 °C |
| Temperature Resolution | 0.1 °C |
| Optical Resolution | 3 pixel/µm |
| Particle Size Range | 0.5–20 µm |
| Power Consumption | <150 W |
| Input Voltage | 220 V, 50 Hz |
| Compliance | GB/T 32668–2016 |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JS94J-1K20X |
| Zeta Potential Range | ±200 mV (typical, dependent on sample conductivity) |
| pH Range | 1.6–13.0 (optimal 2.0–12.0) |
| Operating Temperature | 20–35 °C |
| Temperature Resolution | 0.1 °C |
| Optical Resolution | 12 pixel/μm |
| System Accuracy | ≤5% systematic error |
| Particle Size Applicability | 0.1–10 μm (aqueous dispersions) |
| Power Consumption | <150 W |
| Input Voltage | 220 V, 50 Hz |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JS94J2-1K20X |
| Zeta Potential Range | ±200 mV (typical, per GB/T 32668-2016 calibration protocol) |
| pH Range | 1.6–13.0 (standard operation: 2.0–12.0) |
| Operating Temperature | 20–35 °C |
| Temperature Resolution | 0.1 °C |
| Optical Resolution | 12 pixel/μm |
| Microscope System | WDK Japan high-magnification optical module, working distance 7 mm |
| System Accuracy | ≤5% relative error (per ISO 13099-2:2012 validation methodology) |
| Particle Size Applicability | 0.1–10 μm (aqueous & organic dispersions) |
| Power Consumption | <150 W, 220 V / 50 Hz |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JS94K-3H20X |
| Zeta Potential Range | ±200 mV (typical, inferred per ISO 13099-2) |
| pH Range | 1.6–13.0 (standard operation 2.0–12.0, resolution 0.1) |
| Temperature Range | Ambient to 35 °C (measurement resolution 0.1 °C) |
| Particle Size Compatibility | 0.2–50 µm (aqueous dispersions) |
| Optical Resolution | 1.93–12 pixels/µm (motorized zoom optical system) |
| Power Consumption | <150 W |
| Compliance | GB/T 32668–2016, ISO 13099-2:2012, ASTM D7825–14 |