| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | 2015i/2025i-D |
| Typical Configuration | EPA Reference/Equivalent Method PM₂.₅ and Coarse PM Sampler |
| Flow Control | Mass Flow Controller (MFC) |
| Fine Particle Flow Rate | 15.0 L/min ±2% |
| Coarse Particle Flow Rate | 1.67 L/min ±2% |
| Filter Format | Dual 47 mm membrane filters per sampling cycle |
| Filter Capacity | Up to 16 filter cassettes (32 total filters) |
| Data Logging Interval | 5-minute resolution |
| Internal Memory | 86 days of operational data (5-min intervals) + 32 filter cycle records |
| Communication Interfaces | RS-232, USB 2.0, Ethernet (10/100 Mbps), iPort™ embedded communications module |
| Operating Temperature Range | −40 °C to +50 °C |
| Regulatory Compliance | U.S. EPA Reference Method for PM₂.₅ (40 CFR Part 53), EPA Equivalent Method for PM₂.₅ and Coarse PM (PM₁₀–PM₂.₅), ISO 12103-1, ASTM D1739, EN 12341 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Models | Partisol 2025i, Partisol 2025i-D |
| Flow Control | Activol Mass Flow Controller |
| Volume Flow Range | 1.67–15 L/min |
| Flow Accuracy | ±2% of setpoint |
| Operating Temperature | −40 °C to +50 °C |
| Power Requirement | 1.5 A @ 240 VAC |
| Data Storage | 86 days at 5-minute intervals + 32 filter records |
| Compliance | U.S. EPA Reference Methods RFPS-0498-118 (PM₂.₅), RFPS-1298-127 (PM₁₀), RFPS-0509-176 (Coarse PM) |
| Safety Certification | CE / EN 61326 |
| Brand | Tianhong |
|---|---|
| Origin | Hubei, China |
| Model | TH-16E |
| Flow Rate | 16.67 L/min |
| Maximum Vacuum Pressure | >20,000 Pa |
| Flow Stability | ≤ ±1% |
| Maximum Flow Error | ≤ ±1% |
| Operating Duration at Max Flow & Load | 2–8 h |
| Motor Service Life at Max Flow & Load | ≥ 50,000 h |
| Compliance | HJ 93–2013, HJ/T 374–2007, HJ 618–2011, Q/WTH 03–2014 |
| Filter Capacity | 16 positions |
| Display | 7-inch capacitive touchscreen (Chinese UI) |
| Data Interface | USB 2.0 |
| Power Recovery | Automatic resume with blackout timestamp logging |
| Remote Monitoring | Ethernet/4G-enabled status and parameter query |
| Brand | Tianhong |
|---|---|
| Origin | Hebei, China |
| Model | TH-16Ea |
| Sampling Flow Rate | 16.67 L/min (constant flow) |
| Flow Range for Mass Concentration Measurement | 0–1000 µg/m³ |
| Filter Capacity | 16 filters per unattended cycle |
| Compliance | Designed for ISO 7708, EN 12341, EPA Method IO-3.3, and GB/T 37186–2018 compliant PM10/PM2.5 monitoring |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Operating Environment | −30 °C to +50 °C, IP55 rated enclosure |
| Data Storage | Internal flash memory ≥3 years (timestamped, audit-trail enabled) |
| Communication | USB 2.0 host port, optional GPRS module (LTE-M/NB-IoT compatible), optional analog/digital I/O for wind speed/direction sensors |
| NFC Interface | ISO/IEC 14443-A compliant embedded tag in filter holder |
| Brand | Tianhong |
|---|---|
| Model | TH-2000PM |
| Measurement Principle | Beta-ray attenuation (¹⁴C source) |
| Particle Size Cuts | TSP, PM₁₀, PM₂.₅, PM₁ |
| Operating Temperature | -30 °C to 50 °C |
| Relative Humidity Range | 0–90% RH (non-condensing) |
| Flow Control | PID-regulated mass flow controller with digital sensor |
| Data Storage | ≥1 year of 1-minute resolution data (internal flash + USB export) |
| Display | 7-inch capacitive touch screen (Chinese UI) |
| Communication Interfaces | RS-232, RS-485, 10/100 Mbps Ethernet, 4–20 mA analog output |
| Radiation Source | ¹⁴C (half-life: 5730 years |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Enclosure Rating | IP54 |
| Compliance | Meets technical requirements of HJ 653–2013 (China), compatible with GB/T 15432–1995 and ISO 10473:2000 for gravimetric equivalence validation |
| Brand | Tianhong |
|---|---|
| Model | TH-3150 |
| Origin | Hubei, China |
| Flow Range | 0.1–1.0 L/min |
| Maximum Vacuum Pressure | 30,000 Pa |
| Flow Stability | ≤5 % |
| Maximum Flow Error | ±0.5 % |
| Continuous Operation Time at Max Flow & Load | 10 h |
| Rated Service Life at Max Flow & Load | 6,000 h |
| Brand | Tianhong |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TH-GDA |
| Price Range | USD 7,000–14,000 (typical configuration includes PM2.5 sampler) |
| Flow Rate Range | 16.4–17.0 L/min |
| Vacuum Pressure | >50 Pa |
| Flow Stability | 16.7 L/min |
| Maximum Flow Error | ±0.1 L/min |
| Continuous Operation Duration at Max Flow & Backpressure | 24 hrs |
| Rated Service Life at Max Flow & Backpressure | ≥50,000 hrs |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | DS2.5 |
| Typical Configuration | PM2.5 Sampling System |
| Pump Type | Pulse-Driven Diaphragm Pump |
| Rated Lifespan | 10,000 hours continuous operation |
| Flow Rate Range | 0–6 L/min (adjustable) |
| Default Operating Flow | 5 L/min |
| Timer Function | 7-day programmable scheduler with 24-hour real-time clock |
| Power Supply | AC/DC input + sealed rechargeable battery (12 Ah) |
| Battery Runtime | ≥12 hours at 5 L/min |
| Low-Battery Protection | automatic shutdown with visual alert |
| Low-Flow Alert | automatic shutdown with visual alert |
| Flow Control | precision electronic mass flow regulation |
| Filter Holder | standard 47 mm membrane filter cassette |
| Inlet Cut-Point | 10 µm (PM₁₀) with optional PM₂.₅ cyclone or impactor |
| Enclosure Rating | NEMA 4X (weatherproof, dust-tight, corrosion-resistant) |
| Weight | 6.8 kg (15 lbs) including battery |
| Dimensions | 24.1 × 20.3 × 27.9 cm (H×W×D) |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | TE-1000 PUF |
| Flow Rate | 280 L/min (10 CFM) |
| Filter Medium | 4" Quartz Fiber Filter (TE-QMA4) |
| Sampling Modules | Dual-Stage Particulate & Gas Sampling Module (TE-1002) |
| Flow Control | Voltage-Regulated 2-Stage Vacuum Motor with Mechanical Timer (7-Day, TE-5007) |
| Pressure Gauge | 0–100" H₂O Magnehelic® (TE-1005) |
| Elapsed Time Indicator | TE-5010 |
| Motor | TE-116125 (220 V / 50 Hz, Start Current: 15 A, Running Current: 5 A) |
| Compliance | EPA Methods TO-4A, TO-9A, TO-13A |
| Sample Compatibility | LC-Ready SVOC Extracts (e.g., PCBs, PAHs, organochlorine pesticides) |
| Configuration | Integrated Field-Deployable Sampler with Anodized Aluminum Frame |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | TE-20-800X |
| Flow Rate | 28.3 L/min |
| Cut-Point Range (aerodynamic diameter) | 10.0 µm to 0.4 µm |
| Stage Count | 8 |
| Filter Diameter | 81 mm |
| Compliance | EPA, OSHA, ACGIH, USP <1117>, ISO 14644-1 (indirect), FDA 21 CFR Part 11 (with validated software) |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Import Status | Imported |
| Model | TE-323 |
| Typical Configuration | Multi-Channel Integrated Air Sampler |
| Power Options | 240 V AC, 50/60 Hz |
| Flow Rate Range | 1–300 mL/min |
| Sample Container | 6-L Silonite®-coated Electropolished Stainless Steel Canister |
| Fill Time | ≤40 min to 10 psi |
| Channel Capacity | Standard 3 channels (expandable to 8) |
| Display | Backlit LCD (4 × 20 characters) |
| Control System | Siemens PLC-based Embedded Controller |
| Condensate Trap | Integrated |
| Pressure Monitoring | Individual Stainless Steel Vacuum Gauge per Channel |
| Flow Control | Three-Way Solenoid Valves with Precision Mass Flow Regulation |
| Data Logging | Timestamped Event Logs with Channel-Specific Start/Stop/Alarm Records |
| Rack Mounting | 19-inch EIA Compliant |
| Footprint | Desktop or Rack-Mountable with Rubber Isolation Feet |
| Compliance | EPA Method TO-14A and TO-15 Certified Sampling Platform |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | TE-6070 |
| Flow Control Options | VFC (TE-6070VFC) or MFC (TE-6070MFC) |
| Flow Rate | 40 cfm (1.133 m³/min), adjustable 1.02–1.24 m³/min (MFC) |
| Filter Medium | 8″ × 10″ quartz fiber filter (TE-QMA) |
| EPA Certification | RFPS-0202-141 (Federal Register Vol. 67, p. 15566, April 2, 2002) |
| Operating Temperature | −30 to 50 °C |
| Relative Humidity | 0–100% RH |
| Altitude Limit | Up to 10,000 ft ASL |
| Power Supply | 220 V / 50 Hz |
| Motor Options | Brushed or brushless |
| Timer Options | Common (C), Digital (D), or Plus (P) control systems |
| Dimensions & Weight | Multiple configurations — e.g., 45.5″ × 22.5″ × 20″ / 50–74 lbs |
| Current Draw | 12 A (startup), 7 A (VFC), 5 A (MFC) |
| Brand | Tisch |
|---|---|
| Origin | USA |
| Model | TE-Wilbur |
| Sampling Flow Rate | 0–25 SLPM (standard operating flow: 16.67 L/min) |
| Dimensions | 508 × 508 × 254 mm |
| Weight | 21.3 kg (18.1 kg without battery) |
| Power | 120/240 VAC, 40 W |
| Operating Temperature | −25 °C to +50 °C |
| Flow Accuracy | ±0.75 L/min |
| Flow Repeatability | ±0.25 L/min |
| Flow Resolution | 0.01 L/min |
| Temperature Sensor (Ambient & Filter) | PT100 RTD, ±0.15 °C accuracy, 0.01 °C resolution |
| Barometric Pressure Sensor | 450–1238 mmHg, ±10.00 mmHg accuracy, 0.75 mmHg resolution |
| Communication | MODBUS RTU/TCP, USB 2.0, RJ45 Ethernet |
| Compliance | 40 CFR Part 53 Appendix L (FRM/FEM), ISO 9001 certified manufacturing |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3302A |
| Pricing | Available Upon Request |
| Dilution Ratios | 100:1 and 20:1 |
| Max Particle Loss | 7% |
| Sample Flow Rate | 5 L/min |
| Compressed Gas Requirement | None |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3306 |
| Pricing | Available Upon Request |
| 50% Cut-Point | 2.5 µm or 4.7 µm |
| Collection Filter | 47 mm diameter |
| Maximum Particle Loss | ≤3% |
| Sampling Flow Rate | 28.3 L/min |
| Vacuum Requirement | 28.3 L/min at 460 mmHg |