| Brand | SDM |
|---|---|
| Origin | Italy |
| Model | 2050 |
| Temperature Range | Ambient to 180 °C (±0.3 °C stability) |
| Power Supply | 220 V, 50/60 Hz |
| Heating Power | 3200 W |
| Dimensions | 58 × 46 × 54 cm |
| Weight | 27 kg |
| Compliance | ASTM D972, IP 183 |
| Bath Material | Stainless Steel |
| Control System | PID Digital Controller with PT100A Sensor |
| Safety Features | Overtemperature Alarm, Low-Level Liquid Warning Light |
| Stirring | Motorized Stainless Steel Agitator |
| Construction | Insulated Dual-Wall Bath with Stainless Steel Lid and Precision Flowmeter Mounting Ports |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | D2440 |
| Pricing | Upon Request |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 16900-7 |
| Temperature Range | Ambient +5 °C to 120 °C |
| Temperature Stability | ±0.1 °C |
| Test Positions | 6 |
| Bath Type | Liquid Immersion Bath |
| Compliant Methods | ASTM D2274, IP 388, ASTM D4310, ASTM D943, SH/T 0175 |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 15200-5 |
| Temperature Range | Ambient to 160 °C |
| Temperature Stability | ±0.1 °C |
| Bath Volume | 72 L |
| Test Positions | 2 |
| Rotation Speed | 100 rpm |
| Voltage | 220–240 V, 50/60 Hz |
| Power Consumption | 3.2 kW |
| Dimensions (W×D×H) | 113 × 78 × 88 cm |
| Weight | 87 kg |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 15400-4 |
| Bath Volume | 60 L |
| Test Temperature | 100 °C |
| Number of Bomb Positions | 4 |
| Maximum Bomb Charging Pressure | 1380 kPa |
| Cooling Method | Water-cooled bath |
| Voltage | 110/120 V or 220/240 V, 50/60 Hz |
| Power Consumption | 3 kW |
| Dimensions (W×D×H) | 135 × 83 × 77 cm |
| Weight | 87 kg |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 15400-5 |
| Bath Volume | 60 L |
| Operating Temperature | 100 °C ± 0.1 °C |
| Test Positions | 4 |
| Maximum Bomb Charging Pressure | 1380 kPa |
| Cooling Method | Dedicated Water-Cooled Quenching Trough |
| Voltage | 110/120 V or 220/240 V, 50/60 Hz |
| Power Consumption | 3 kW |
| Dimensions (W×D×H) | 135 × 83 × 77 cm |
| Weight | 87 kg |
| Compliance | ASTM D525, D873, IP 40, IP 138, ISO 7536, EN 7536, GB/T 8018, JIS K2287, NF M07-012/013, FTM 791-3352/3354, BS 2000-40/138 |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 15550-2 |
| Temperature Range | Ambient to 150 °C |
| Temperature Stability | ±0.1 °C |
| Bath Medium | Water or Oil |
| Bath Volume | 35 L |
| Power Rating | 1500 W |
| Voltage Options | 110/120 V or 220/240 V, 50/60 Hz |
| Dimensions (W×D×H) | 41 × 45 × 33 cm |
| Weight | 10 kg |
| Test Positions | 4 |
| Construction Material | Stainless Steel |
| Controller Type | Digital with Over-Temperature and Low-Level Safety Interlocks |
| Optional Accessory | Automated Pressure Monitoring Module |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 16670-0 |
| Heating Method | Solid (metal block) |
| Temperature Range | Ambient to 100 °C |
| Test Positions | 4 |
| Voltage | 200–240 V, 50/60 Hz |
| Power Consumption | 3 kW |
| Dimensions (W×D×H) | 30 × 60 × 28 cm |
| Weight | 65 kg |
| Compliance | ASTM D525, D873, D2274, D4310, D7462 |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SKY2101-IIA |
| Test Method Compliance | ASTM D525, GB/T 8018, ISO 7536, IP 40 |
| Temperature Setpoint | 100 °C ± 0.1 °C |
| Pressure Range | 0–1.6 MPa (±0.1% FS) |
| Heating System | Solid Metal Bath |
| Display | 12″ Color Touchscreen |
| Data Storage Capacity | ≥5000 Test Records |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max Power Consumption | ≤1800 W |
| Dimensions (W×D×H) | 370 × 520 × 645 mm |
| Net Weight | 60 kg |
| Ambient Operating Conditions | 5–35 °C, 20–80% RH |
| Oxygen Supply | ≥99.6% purity, 800–850 kPa |
| [Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SKY3012-III |
| Test Method Compliance | ASTM D2272, ASTM D2112, SH/T 0193, IP 229 |
| Temperature Control Accuracy | ±0.1°C at 140.0°C and 150.0°C |
| Sample Mass | 50 g ±0.5 g |
| Oxygen Bomb Rotation Speed | 100 rpm ±1 rpm |
| Oxygen Charging Pressure | 620 kPa ±1.4 kPa (max 680 kPa) |
| Pressure Measurement Range | 0–1.6 MPa, accuracy 0.1% FS |
| Oxygen Bomb Tilt Angle | 30° |
| Heating Medium | Solid metal bath |
| Power Supply | AC 220 V ±10%, 50/60 Hz, 1400 W |
| Dimensions (W×D×H) | 320 × 540 × 640 mm |
| Net Weight | 63 kg |
| Ambient Operating Conditions | 20–30°C, 20–80% RH] |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SYP2006 |
| Compliance | SH/T 0175, ASTM D2274 |
| Oxygen Flow Rate | 50 ± 5 mL/min (per channel) |
| Temperature Control | 95 ± 0.2 °C |
| Temperature Sensor | GB/T 514 compliant, 80–100 °C range, 0.1 °C graduation |
| Oxidation Duration | Programmable up to 16 h |
| Sample Capacity | 6 parallel oxidation tubes |
| Oxidation Tube Material | Borosilicate glass per SH/T 0175–94 |
| Filter Membrane | Cellulose ester, 50 mm diameter, 0.8 µm pore size |
| Evaporation Vessel | Borosilicate glass tall-form beaker, 200 mL |
| Heating Power | 3 kW (4 × 750 W tubular heaters) |
| Oxygen Stabilization | Integrated pressure-regulating valve upstream of flowmeters |
| Drying & Filtration System | Cylindrical assembly with stainless-steel mesh, silica gel, and degreased cotton |
| Dark Storage Cabinet | Metal enclosure for post-oxidation tube cooling |
| Footprint | Floor-standing configuration with four swivel leveling feet |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Quantum |
| Pricing | Upon Request |