Petroleum Specialized Analytical Instruments
Filter
Showing 151–180 of 451 results
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MINISCAN IR Vision Gasoline |
| Portability | Portable |
| Measurement Range | 70–110 (RON/MON) |
| Accuracy | ±0.5 |
| Analysis Time | <80 s |
| Sample Volume | 6 mL |
| Compliance | GB/T 33648–2017, ASTM D5845, ASTM D6277, EN 238, SH/T 0797, ASTM E1655, GB/T 29858 |
| Spectrometer Type | Temperature- and Laser-Stabilized Dual Interferometer with KBr-coated Ge Beamsplitter |
| Sample Cell | Thermoelectrically Controlled 2+1 Smart Cell Design |
| Density Measurement | Integrated TE-Controlled Digital Density Meter (±0.0001 g/cm³) |
| Data Output Units | v%, m% |
| Display | 10-inch Industrial TFT Touchscreen |
| Connectivity | 2× USB, 2× LAN |
| Power | 100–264 V AC / 47–63 Hz / 130 W or 12 V DC via Vehicle Adapter |
| Dimensions | 293 × 390 × 280 mm |
| Weight | 12 kg |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MINISCAN IR Vision Gasoline |
| Portability | Portable |
| Measurement Range | 70–110 (RON/MON) |
| Accuracy | ±1 ON |
| Analysis Time | 1 min |
| Sample Volume | 10 mL |
| Spectral Range | Mid-IR (KBr-coated Ge beam splitter) |
| Density Measurement | Integrated thermostatted densitometer, resolution ±0.0001 g/cm³ |
| Data Output Units | v%, m% |
| Display | 10-inch industrial-grade full-color touchscreen |
| Compliance | ASTM D5845, ASTM D6277, EN 238, SH/T 0797, ASTM E1655, GB/T 29858, GB/T 33648-2017 |
| Chemometric Engine | PLS (Partial Least Squares) with validated multivariate calibration models |
| Connectivity | 2× USB, 2× LAN |
| Power | 100–264 V AC, 47–63 Hz, 130 W |
| Dimensions | 293 × 390 × 280 mm |
| Weight | 12 kg |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MINISCAN IR VISION |
| Portability | Portable |
| Measurement Principle | Fourier Transform Infrared (FT-IR) Spectroscopy |
| Measurement Range | Octane Number (RON) 65–110, Cetane Number 20–80 |
| Optical Resolution | Better than 2 cm⁻¹ |
| Analysis Time | <30 s (single scan), ≤80 s (multi-scan averaging) |
| Sample Volume | 6 mL |
| Compliance | ASTM D5845, D6277, D7777, D7806, EN 238, EN 14078, ISO 15212 |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MINISCAN IR Vision |
| Application | Gasoline Octane Number (RON/MON), Diesel Cetane Number (CN) |
| Portability | Portable |
| Measurement Range | 70–110 |
| Measurement Accuracy | ±1 unit |
| Analysis Time | <5 min |
| Sample Volume | 6 mL |
| Compliance | GB/T 33648–2017, ASTM D5845, ASTM D6277, EN 238, SH/T 0797, EN 14078, ASTM D7806, GB/T 23801, ASTM E1655, GB/T 29858 |
| Spectral Technology | Fourier Transform Mid-Infrared (FT-MIR) with Dual Interferometer Architecture |
| Calibration Method | Partial Least Squares (PLS) Multivariate Quantitative Analysis |
| Integrated Density Measurement | Thermoelectrically Controlled Oscillating U-tube Densitometer |
| Operating Interface | 10-inch Industrial Capacitive Touchscreen (Multi-language: English, Chinese, German) |
| Data Storage | Internal SSD with Full Spectrum Archiving |
| Connectivity | 2× USB 3.0, 2× Gigabit Ethernet |
| Power Supply | 100–264 V AC, 47–63 Hz, 130 W |
| Optional Mobile Power | 12 V DC Vehicle Adapter |
| Dimensions | 293 × 390 × 280 mm |
| Weight | 12 kg |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MINITEST FFK |
| Product Type | Portable Instrument |
| Standard Compliance | DIN 51805 |
| Temperature Range | –60 to +30 °C |
| Temperature Accuracy | ±0.1 °C |
| Pressure Measurement Range | 0–300 kPa |
| Pressure Accuracy | ±0.1 kPa |
| Power Supply | 100–240 V AC, 50/60 Hz, 200 W |
| Dimensions (W×H×D) | 196 × 315 × 175 mm |
| Weight | 10 kg |
| Interface | RS232 |
| Display Languages | English, German |
| Cooling Method | Peltier-based thermoelectric control |
| Sample Handling | Standalone operation, no auxiliary equipment required |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MINITEST FFK |
| Application Standard | DIN 51805 |
| Temperature Range | –60 °C to +30 °C |
| Temperature Accuracy | ±0.1 °C |
| Pressure Range | 0–300 kPa |
| Pressure Accuracy | ±0.1 kPa |
| Power Supply | 100–240 V AC, 50/60 Hz, 200 W or 12 V DC / 10 A |
| Dimensions (W×H×D) | 196 × 315 × 175 mm |
| Weight | 10 kg |
| Interface | RS232 |
| Display Languages | English, German |
| Cooling Method | Peltier-based |
| Sample Compatibility | NLGI Grades 000–3 Greases |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MINITEST FFK |
| Test Principle | Corrosion-Resistant Capillary Extrusion (DIN 51805) |
| Temperature Range | −50 °C to +30 °C |
| Temp. Accuracy | ±0.1 °C |
| Pressure Range | 0–300 kPa |
| Pressure Accuracy | ±0.1 kPa |
| Dimensions | 196 × 315 × 175 mm |
| Weight | 10 kg |
| Power Supply | 100–240 V AC, 50/60 Hz, 200 W or 12 V DC (optional) |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MiniVAP ON-LINE |
| Analysis Method | Three-Stage Expansion Method |
| Pressure Range | 2–1000 kPa |
| Temperature Range | 20–60 °C |
| Repeatability (r) | 0.30 kPa |
| Reproducibility (R) | 0.7 kPa |
| Sample Throughput Cycle Time | 7 min |
| Power Supply | 100/120/230/240 V AC, 50/60 Hz, 65 W |
| Dimensions (W × H × D) | 650 × 1160 × 400 mm |
| Weight | 50 kg |
| Explosion Protection | Class I, Division 1, Group D (NFPA 496, US) / Zone 1, II 2 G Ex d IIB T4 (EN 50016, EU) |
| Vapor-to-Liquid Ratios (V/L) | 4:1 (gasoline & crude oil), 1:2 (LPG & NPG), 20:1 (LVR temperature mode) |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MINIVAP VP Vision |
| Analysis Method | Triple Expansion Method |
| Pressure Range | 0–2000 kPa |
| Temperature Range | 0–120 °C |
| Repeatability | ≤ 0.2 kPa (pure substance @ 37.8 °C) |
| Reproducibility | ≤ 0.5 kPa (pure substance @ 37.8 °C) |
| Sample Volume | 1 mL |
| Test Time | ~5 min (method-dependent) |
| Display | 10-inch industrial-grade touchscreen |
| Compliance | ASTM D5191, D6377, D6378, D6897, D5188, EN 13016-1+2, IP 394/409/481, JIS K2258-2, GOST 52340, SH/T 0769, SH/T 0794, GB/T 11509, GB/T 8017-2012 |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MINIVAP VP VISION |
| Analysis Method | Three-Stage Expansion Method |
| Pressure Range | 0 to 2000 kPa |
| Temperature Range | −100 to 300 °C |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MINIVAP VP VISION+ Crude Oil Package |
| Analysis Method | Three-stage Expansion Method |
| Compliance | ASTM D6377, ASTM D3700, GOST R 52340, EPA Method for TVP |
| Sample Volume | 250 mL (10 mL per test) |
| Maximum Operating Pressure | 7000 kPa |
| Material | High-grade stainless steel |
| Integrated Components | Pressure sensor, rupture disc, manual agitation plate, dedicated crude oil inlet interface |
| Filling Options | Manual or pressurized |
| Agitation | Built-in manual agitation plate with pressure monitoring |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MiniVAP VPS/VPSH |
| Analysis Method | Three-Stage Piston Expansion Method |
| Pressure Range | 0–1000 kPa |
| Temperature Range | 0–100 °C |
| Test Time | ~5 min per sample |
| Dimensions | 196 × 315 × 175 mm |
| Weight | 8 kg |
| Power Supply | 100–230 V AC, 50 Hz, 65 W |
| Optional DC Input | 12 V / 8 A |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MiniVAP VPSH+ Crude Oil Package |
| Application | Crude oil vapor pressure (RVP/TVPR) determination per ASTM D323, D6377, and ISO 3014 |
| Sample Handling | Mobile piston cylinder sampling system with pressurized transfer and mechanical agitation |
| Automation | Fully automated measurement cycle including purge, equilibration, pressure stabilization, and cleaning |
| Compliance | Designed to meet ASTM D6377 (TVPR), ASTM D323 (RVP), ISO 3014, and EN 13016-1 requirements |
| Operating Temperature | 37.8 °C (100 °F) controlled bath |
| Pressure Range | 0–200 kPa (0–29 psi) absolute |
| Resolution | 0.1 kPa |
| Repeatability | ≤0.5 kPa (per ASTM D6377) |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MobileLab |
| Power Supply | Dual 12 V DC (rechargeable battery) & 230 V AC input |
| Environmental Control | Independent HVAC panel with 20 air changes/hour |
| Mounting | Seismically damped instrument racks |
| Water System | Integrated sink with fresh/distilled water supply and dedicated waste container |
| Data Integration | Centralized software via RS-232/USB serial interface |
| Compliance Support | Designed for ASTM D93, D130, D2887, D445, ISO 3104, ISO 2719, EN 13016, GOST R 51105, and related fuel testing standards |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | ParaFuel™ |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Scan Time | Adjustable, default 30 s |
| Communication Interface | Standard TCP/IP Ethernet, optional Modbus TCP or 4–20 mA |
| Process Points | Up to 20 via multiplexed fiber-optic probes |
| Sample Temperature Range | Up to 150 °C |
| Sample Pressure Rating | Up to 7,000 kPa |
| Fiber Optic Cable Length | Standard 3 m, extendable to 200 m |
| Enclosure Rating | IP65 (dust- and water-resistant) |
| Hazardous Area Classification | CSA C1D2 (optional C1D1) |
| Desktop Unit Dimensions | 30.5 cm × 39.7 cm × 34.9 cm (12" × 15" × 13") |
| Data Storage | Automatic local logging + LIMS integration via TCP/IP |
| Software Platform | LTBus-based Windows application with audit trail, user access levels, and FDA 21 CFR Part 11–compliant electronic signatures (optional) |
| Brand | Grace |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | M3900 |
| Price | Upon Request |
| Brand | Grace |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M7355 |
| Pricing | Upon Request |
| Max Pressure | 20,000 psi |
| Full-Scale Range | ±30 mL |
| Pressure Control Accuracy | ±25 psi |
| Water Supply | Municipal tap water |
| Power | 120 V, 50/60 Hz |
| Dimensions | 19" W × 24" D × 47" H |
| Weight | 95 lb |
| Brand | Grace |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | M9200 |
| Quotation | Upon Request |
| Operating Temperature | Ambient to 177 °C |
| Maximum Working Pressure | 5000 psi |
| Shear Rate Range | 0–1500 s⁻¹ |
| Sample Volume | 115 mL |
| Intermediate Vessel Capacity | 500 mL, Rated to 6000 psi |
| Observation Chamber | Stereo Microscope with Sapphire Window |
| Foaming Gas Options | CO₂ or N₂ |
| Brand | Grace |
|---|---|
| Origin | USA |
| Model | M9250 / M9350 |
| Pressure Range | 0–150 psi |
| Flow Rate | 2–15 gal/min |
| Fluid Temperature | 60–90 °F |
| Mixing Tank Capacity | 15–30 gal |
| Differential Pressure Accuracy | ±0.1% of Full Scale |
| Brand | Grace |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M9300 |
| Price | Upon Request |
| Temperature Range | 21–177 °C |
| Maximum Operating Pressure | 5000 psi |
| Maximum Confining Pressure | 5000 psi |
| Maximum Back Pressure | 10,000 psi |
| Shear Rate Range | 0–1500 s⁻¹ |
| Brand | Grace |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | M9720 |
| Pricing | Available Upon Request |
| Max Temperature | 150 °C |
| Max Pressure | 20,000 psi |
| Construction Material | Hastelloy® C-276 |
| Particle Detection Limit | ≤5 µm |
| Pressure Accuracy | ±0.1% of Full Scale |
| Temperature Accuracy | ±0.2 °C |
| Brand | Green Lab |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | ADEM |
| Compliance | ASTM D1401, ISO 6614 |
| Automation Level | Fully Automated with Audit-Traceable Test Execution |
| Sample Volume | 40 mL per test (standard) |
| Temperature Control | ±0.5 °C over 54 °C and 82 °C test points |
| Test Duration | Up to 120 min with programmable endpoint detection |
| Data Output | CSV/Excel-compatible timestamped reports with operator ID, method version, and environmental log |
| Brand | Hengmei |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HM-NQ |
| Price | USD 2,500 (approx.) |
| Temperature Range | −70 °C to +51 °C |
| Compliant Standards | GB/T 510, ISO 3016, ASTM D97, ASTM D6749, SN/T 3017 |
| Detection Method | Automated Pneumatic Pressure Method |
| Sample Volume | 4.5 mL |
| Test Interval | 1 °C |
| Repeatability | ±1 °C |
| Temperature Sensor | Class A PT100 |
| Temperature Accuracy | ±0.1 °C |
| Applied Test Pressure | 310 Pa |
| Cooling Method | Semiconductor-based Thermoelectric Cooling |
| Heating Rate | 1–3 °C/min |
| Cooling Rate | 3–4 °C/min (from ambient to −40 °C), 0.8–1.1 °C/min near pour point |
| Display | 7-inch HD Touchscreen (1024×600) |
| OS | Android-based Embedded System |
| Data Storage | Unlimited (eMMC-dependent) |
| Connectivity | Cloud Upload, USB Export, Thermal Printer Support |
| Power Supply | AC 220 V ±10%, 50 Hz ±5% |
| Max Power Consumption | ≤350 W |
| Dimensions (L×W×H) | 440×370×390 mm |
| Net Weight | 19 kg |
| Brand | Beijing Hangfeng |
|---|---|
| Origin | Beijing, China |
| Model | HFN-B |
| Measurement Principle | Capillary Efflux (ASTM D445 / ISO 3104 compliant) |
| Temperature Control | 40 °C ± 0.1 °C |
| Sample Volume | 80 µL |
| Measurement Time | ≤ 30 s per test |
| Viscosity Range | 2–1000 mm²/s (cSt) at 40 °C |
| Calibration | Multi-point viscosity standard calibration (certified mineral oil standards) |
| Display | 7-inch capacitive touchscreen |
| Power | Rechargeable Li-ion battery (≥ 8 h continuous operation) |
| Cleaning | Solvent-free — dry wipe with lint-free industrial cloth |
| Compliance | Designed to support ASTM D445, ISO 3104, and ISO 2909 procedures for kinematic viscosity determination |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | HK-265 |
| Price | Upon Request |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Temperature Control Range | 20–100 °C |
| Temperature Stability | ±0.1 °C (optional ±0.01 °C with HK-265A configuration) |
| Heating Power | 1800 W |
| Illumination | LED with silicone diffuser panel |
| Sample Holders | 4 capillary viscometer clamps |
| Safety Features | Liquid-level protection sensor |
| Cooling Interface | Dedicated external chiller port |
| Operating Environment | 5–40 °C, ≤85% RH |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Model | HK-6536A |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Heating Power | 0–1000 W (continuously adjustable) |
| Bath Temperature Range | 0–60 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Voltage Regulation | Solid-State Phase-Angle Controller (stepless) |
| Stirring Method | Motor-Driven Stirring |
| Flask Capacity | 125 mL |
| Graduated Cylinder Capacity | 100 mL |
| Ambient Operating Conditions | 10–40 °C, ≤85% RH |
| Distillation Configuration | Single-Tube, Ambient Pressure |
| Compliance | GB/T 6536 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | HK-6536C |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Rated Power | 3800 W |
| Temperature Control | Digital PID Controller |
| Temperature Accuracy | ±0.5 °C |
| Condensate Bath Range | 0–60 °C |
| Air Bath Range | 1 °C to Ambient |
| Cooling Method | Forced-Air with Dual Electric Coolers |
| Stirring | Pump-Circulated Coolant |
| Heating Element | Quartz Tube Heaters |
| Thermometer Fixation | Silicone Rubber Stopper |
| Air Chamber | Auto-Temperature Regulation & Digital Display |
| Illumination | Dual LED Auxiliary Lighting |
| Operating Environment | 5–40 °C, RH ≤85% |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | SLFA-60 |
| Detection Target | Total Sulfur |
| Measurement Principle | X-ray Fluorescence (XRF) Spectrometry |
| Detection Range | 0–10 wt% S |
| Detection Limit | 5 ppm |
| Precision | ±5 ppm (at 1.0% S), ±1.6 ppm (at 0% S) |
| Sample Volume | 4–10 mL per analysis |
| Measurement Time | Adjustable from 10 to 600 seconds |
| Sample Capacity | 8-position automated rotary stage |
| Sample Holder | Disposable liquid-specific film-bottom cup |
| Calibration Flexibility | Up to 20 calibration points across 5 stored curves (linear/nonlinear) |
| Environmental Operating Range | 5–35 °C, 30–85% RH |
| Power Supply | AC 100–240 V ±10%, 50/60 Hz |
| Power Consumption | 150 VA |
| Interface | RS-232C standard serial port |
| Dimensions | 430 × 500 × 230 mm |
| Weight | ~24 kg |
| Compliance | ASTM D4294, ISO 8754, JIS K2541 & B7995, GB/T 17040–1997, GB/T 17060–1998, SN/T 0509–1995 |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HX-VIS1000 |
| Compliance Standard | GB/T 265 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% |
| Dimensions (W×D×H) | 545 × 370 × 500 mm |
| Weight | 18.4 kg |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Spectro Scientific |
| Type | Portable Mid-IR ATR Analyzer |
| Model | InfraCal 2 ATR-B |
| Detection Range | 0–100% biodiesel in diesel |
| Analysis Time | <30 s |
| Repeatability | ±0.2% (0–30%), ±1.0% (30–100%) |
| Compliant With | ASTM D7371, EN 14078 |
| Power | Rechargeable Li-ion battery (6+ hrs operation), 18 V DC input |
| Weight | 2.6 kg (net), 3.2 kg (with battery) |
| Dimensions | 17 × 19.8 × 13.2 cm |
| Operating Temperature | 5–40 °C |
| Wavelength | 5.7 µm (1745 cm⁻¹) |
| Interface | USB, RS-232 |
| Data Storage | Internal, password-protected, with operator/location/timestamp metadata |
| Display | Touchscreen LCD |
| Language Support | English, Spanish, French, Arabic |