Petroleum Specialized Analytical Instruments
Filter
Showing 121–150 of 1348 results
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | SYD-8017 |
| Power Supply | AC (220 ± 10%) V, 50 Hz |
| Water Bath Temperature Range | Ambient to 90 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Pressure Gauge Accuracy | ±0.4 % |
| Dual-Port Test Configuration | Yes |
| Conformance | GB/T 8017 (Reid Vapor Pressure Method) |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SYD-8018D-1 |
| Pricing | Upon Request |
| Temperature Setpoint | 100.0 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Pressure Range | 0–1600 kPa |
| Pressure Sensor Accuracy | ±0.2% FS |
| Touchscreen | 10.1-inch Color LCD with Windows 7 OS |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Heating Power | 1400 W |
| Dimensions (W×D×H) | 630 mm × 280 mm × 380 mm |
| Net Weight | 50 kg |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | SYD-9168A |
| Test Mode | Vacuum (Reduced Pressure) |
| Temperature Range | 30 °C to 80 °C ±3 °C (for condenser cooling bath) |
| Temperature Accuracy | ±0.5 °C |
| Absolute Pressure Control Range | 2, 5, 10, 20, 50 mmHg |
| Pressure Measurement Range | 2.00–170.00 mmHg ±0.01 mmHg |
| Pressure Control Precision | <0.01 mmHg (at residual pressure <7.5 mmHg) |
| Cold Trap Temperature | ≤−40 °C (Peltier-cooled) |
| Heating Power | 0–500 W adjustable |
| Total Power Consumption | ≤1800 W |
| Compliance | GB/T 9168 |
| Brand | Checkfluid |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | KP |
| Pricing | Upon Request |
| Brand | Checkfluid |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | KST |
| Pricing | Upon Request |
| Valve Type | Industrial-standard 2 mm probe-style valve |
| Thread Options | Multiple NPT/BSP thread configurations available |
| Installation | Direct-mount, no adapter required |
| Nozzle Cap | Knurled anti-slip design |
| Surface Coating | Zinc-nickel plating (5–7× corrosion resistance vs. standard zinc) |
| Sample Contamination Risk | Minimal carryover volume |
| Sealing Mechanism | Patented elastomeric vacuum seal with automatic shut-off |
| Maximum Operating Pressure | 27.6 MPa (4000 psi) |
| Probe Compatibility | Requires compatible sampling probe (sold separately) |
| Brand | Checkfluid |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LP Series |
| Pricing | Upon Request |
| Brand | Checkfluid |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LTJ |
| Pricing | Upon Request |
| Brand | Checkfluid |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LTJ |
| Pricing | Upon Request |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | VISCO 370 |
| Measurement Principle | Capillary Viscometry (Ostwald/Ubbelohde/Cannon-Fenske) |
| Temperature Range | –40 °C to +150 °C |
| Temperature Stability | ±0.01 °C (DT-series bath) |
| Timing Resolution | 0.01 s |
| Timing Accuracy | ±0.01% (±1 digit) |
| Kinematic Viscosity Range | 0.35–1800 mm²/s (cSt) under pressure mode |
| Capillary Compatibility | Ubbelohde, Cannon-Fenske, micro-Ostwald, micro-Ubbelohde, dilution-type, and thermal conductivity viscometers |
| Calibration | ISO/ASTM-traceable capillaries with certified constants to four decimal places |
| Module Scalability | Up to 8 independent measurement units |
| Cleaning Options | Single- or dual-solvent automated rinsing with programmable solvent volume, rinse duration, and drying time |
| Software | WinVisco 4 (multi-language: EN/DE/FR/ES/CN), supports ASTM D445, ISO 3104, ISO 1628, USP <911>, and GLP-compliant audit trail |
| Data Output | PDF & CSV reports with timestamped filenames, full traceability, and user-level access control (3-tier permissions) |
| Compliance | Fully compliant with ASTM D445, ISO 3104, ISO 1628-1, DIN 51562, and FDA 21 CFR Part 11 (when configured with electronic signature and audit trail enabled) |
| Brand | Chinyee |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | APD500A |
| Pricing | Available Upon Request |
| Application | Fuel Oil, Crude Oil Residues, FCC Slurry Oil, Coker Drum Effluents |
| Sample Limitations | Not suitable for samples containing non-toluene-soluble solids (e.g., sludge), high-melting-point paraffins (>50 °C), or natural bitumens |
| Measurement Range | 0.5–15 wt% |
| Repeatability | ±2% RSD |
| Measurement Time | 30 s (excluding sample prep) |
| Optical Method | Dual-wavelength photometry using interference filters |
| Light Source | Tungsten-halogen lamp |
| Wavelengths | 750 nm and 880 nm |
| Detector | Silicon photodiode |
| Interface | RS-232C |
| Power Supply | 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 460 × 165 × 635 mm |
| Weight | 25 kg |
| Output | Integrated thermal printer + RS-232C port |
| Safety Certification | CE-compliant |
| Brand | CINRG |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CS-APC-2 |
| Product Category | Laboratory Instrument |
| Test Parameter | Contaminant Particles |
| Compliance | ASTM D7647-10 |
| Sample Processing Time | 4–5 min/sample |
| Solvent Consumption | 40 mL/sample |
| Autosampler Capacity | 102 samples (104-position tray |
| Sensor Model | KLOTZ LDS 45/50 Laser Sensor |
| Measurement Range | 1.5 µm – 100 µm |
| Flow Rate | 30 mL/min (calibrated) |
| Detection Thresholds | 25,000 particles/mL at ≥4 µm (neat oil), 50,000 particles/mL at ≥4 µm (1:1 dilution) |
| Volume Accuracy | ±2% (pre-dilution) |
| Customizable Reporting | User-defined pass/fail limits at 4 µm, 6 µm, and 14 µm |
| Data Export Fields | Solvent blank count, sample volume, dilution ratio, raw particle counts per channel |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | W-06-01 |
| Pricing | Available Upon Request |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 25755-xx |
| Density Range (25755-00/14) | 0.750–1.000 g/cm³ |
| Density Range (25755-04/20) | 1.000–1.300 g/cm³ |
| Density Range (25755-10) | 1.300–1.600 g/cm³ |
| Density Resolution | 0.001 g/cm³ |
| Density Accuracy | ±0.03 g/cm³ |
| Temperature Range (°C models) | 0–50 °C |
| Temperature Range (°F models) | 32–120 °F |
| Temperature Resolution | 0.1 °C or 0.1 °F |
| Temperature Accuracy | ±0.8 °C / ±0.5 °F |
| Max Sample Viscosity | 400 cP |
| Probe Immersion Depth | 5 in (127 mm) |
| Display | Dual-line backlit LCD |
| Power | 4 × AA batteries (included) |
| Probe Dimensions | 8 in L × 1.25 in dia (203 mm × 32 mm) |
| Instrument Dimensions | 4 in W × 8.25 in H × 1.5 in D (102 mm × 210 mm × 38 mm) |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 38000-X |
| Capacity Options | 8.32 mL (US), 83.2 mL (US), 100 mL (UK) |
| Volume Tolerance | ±1.2% (38000-02), ±0.5% (all other variants) |
| Tare Accuracy | ±0.2 g (8.32 mL cup), ±0.1 g (38000-02 variant) |
| Compliance | MIL-STD-45662A |
| Calibration Certificate | Optional (38000-16, 38000-26) |
| Material | 316 stainless steel |
| Dimensions | 26.5 × 25.4 mm (38000-02), 63.5 × 44.5 mm (38000-12/16), 78.3 × 44.5 mm (38000-22/26) |
| Water Mass at Fill | 47 g (8.32 mL), 213 g (83.2 mL), 243 g (100 mL) |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 38000-xx |
| Capacity | 8.32 mL (38000-00) / 83.2 mL (38000-10, 38000-14) / 100 mL (38000-20, 38000-24) |
| Tolerance | ±1.2% (38000-00) / ±1.5% (38000-10/14/20/24) |
| Height | 26.5 mm (38000-00) / 63.5 mm (38000-10/14) / 78.3 mm (38000-20/24) |
| Outer Diameter | 25.4 mm (38000-00) / 44.5 mm (38000-10/14/20/24) |
| Weight | 47 g (38000-00) / 213 g (38000-10/14) / 243 g (38000-20/24) |
| Standard Compliance | ASTM D189, ASTM D524, DIN 51709, IP 14, ISO 10370 |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 25750-60 |
| Density Range | 0–3 g/cm³ (or SGU) |
| Density Resolution | 0.01 g/cm³ (or SGU) |
| Temperature Range | 0–40 °C |
| Temperature Resolution | 0.1 °C |
| Sample Volume | 2 mL |
| Dimensions | 14.0 × 13.6 × 2.5 cm |
| Power | 1.5 V AA battery |
| Interface | Infrared output |
| Data Storage | 1024 readings |
| Display | Large LCD showing density, specific gravity, % concentration, and sample temperature |
| Key | Brand: PULUODY |
|---|---|
| Model | PLD-0232A |
| Temperature Control Range | 40 °C |
| Temperature Accuracy | ±0.5 °C |
| Timing Range | 0–100 min (user-adjustable) |
| Power Supply | AC 220 V |
| Max. Power Consumption | 1200 W |
| Construction | Stainless Steel Bath & Lid |
| Compliance | SH/T 0232 |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | CRYSTEX |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CS325 |
| Pricing | Available Upon Request |
| Brand | CSFriend |
|---|---|
| Origin | Hunan, China |
| Model | FDT-0234 |
| Flash Point Range | -30 °C to 50 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Measurement Precision | < 2 °C |
| Sample Volume | 2 mL (liquid), 4 mL (solid/semi-solid) |
| Ignition Method | Electronic spark igniter |
| Cooling System | Peltier thermoelectric cooling with external chilled water circulation |
| Power Supply | AC 220 V ±10 %, 50 Hz |
| Max. Power Consumption | ≤300 W |
| Operating Ambient | 5–30 °C, 30–80 % RH |
| Compliance | GB/T 5208 (Rapid Equilibrium Closed-Cup Method) |
| Brand | AYALYTICAL |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | CuDDI |
| Pricing | Contact for Quote |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | D1263 |
| Pricing | Upon Request |
| Origin | Czech Republic |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Deasphaltop |
| Pricing | Available Upon Request |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | A-1190 |
| Price Range | USD 4,200 – 7,000 |
| Test Method | Closed-Cup (Pensky-Martens) |
| Operation Mode | Fully Automatic |
| Compliant Standards | GB/T 261-2008, GB/T 21615-2008, ASTM D93 |
| Repeatability | ≤2 °C |
| Ignition Method | Electronic spark ignition and adjustable gas flame |
| Temperature Range | 10–40 °C (ambient operating), 0–350 °C (test range) |
| Resolution | 0.1 °C |
| Data Storage | 120 test records onboard |
| Interface | RS-232 & RS-485 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max. Power Consumption | ≤300 W |
| Relative Humidity | <85% RH |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | A1017 |
| Measurement Range | 10–2,000,000 mPa·s |
| Rotor Set | Four standard spindles (No. 1–4) |
| Speed Settings | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm (stepped, not continuously variable) |
| Accuracy | ±1% of full scale (F.S.) |
| Display | Backlit high-contrast LCD showing viscosity, spindle number, rotational speed, sample temperature, % torque, and maximum measurable viscosity at selected speed |
| Data Output | RS232 serial interface for PC connectivity |
| Printing | Integrated thermal or impact dot-matrix printer support (via parallel/RS232) |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Optional DC Input | 12 V / 1 A adapter |
| Operating Environment | 5–45 °C, ≤85% RH |
| Net Weight | 16 kg |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Delite A1018 |
| Price | USD 13,800 (FOB Beijing) |
| Viscosity Range | 1000–1,000,000 mPa·s |
| Temperature Control Range (Bath) | −60 °C to +25 °C |
| Sample Temp Accuracy | ±0.1 °C |
| Bath Temp Stability | ±0.1 °C |
| Rotational Speeds | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm |
| Included Rotors | LV-1, LV-2, LV-3, LV-4 (4 total) |
| Power Supply | AC 220 V ±10%, ≤1500 W |
| Interface | RS-232C, PT100 temperature probe port |
| Cooling Method | Imported hermetic compressor |
| Calibration | Certified reference oils (ASTM D2983, ISO 3104 compliant) |
| Dimensions | 480 × 580 × 610 mm |
| Weight | 85 kg |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Portable Instrument |
| Model | A1030 |
| Detection Target | Particulate Contaminants in Hydraulic & Lubricating Oils |
| Microscope Magnification | 100× |
| Particle Size Range | 5–150 µm |
| Cleanliness Rating Scales | NAS 1638 (Classes 00–12) and ISO 4406:2021 (Codes 1–24) |
| Filter Membrane Pore Sizes | 1.2 µm and 5 µm |
| Compliance Standard | DL/T 432–1992 |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | A1065 |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Accuracy | ±1 °C |
| Stirring Speed | 1500 rpm |
| Sample Capacity | 8 test tubes |
| Stirring Timer Range | 1–59 min |
| Sample Equilibration Timer | 1–59 min |
| Stirrer Shaft Pre-heat Timer | 1–59 min |
| Arm Dwell Time | 1–59 min |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max. Power Consumption | ≤2000 W |
| Dimensions (W×D×H) | 572 mm × 335 mm × 791 mm |
| Net Weight | 38 kg |
| Compliance Standards | GB/T 7305, GB/T 7605 |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | A1104 |
| Power Supply | AC 220 V, 50 Hz |
| Temperature Control Range | RT+10 °C to 300 °C (minimum setpoint 50 °C) |
| Temperature Stability | ±1 °C |
| Temperature Resolution | 0.1 °C |
| Rated Power | 1220 W |
| Test Stations | 4 glass vials |
| Rotation Speed | 5 rpm |
| Interior Chamber Dimensions | 425 × 400 × 345 mm |
| Overall Dimensions | 705 × 580 × 530 mm |
| Applicable Standards | SH/T 0301, ASTM D2619 |