| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AD1748 |
| Pricing | Upon Request |
| Power Supply | 220 V / 50 Hz, 1500 W |
| Dimensions (L×W×H) | 850 × 750 × 1100 mm |
| Weight | 140 kg |
| Temperature Control Accuracy | ±0.5 °C at 48.9 °C |
| Temperature Resolution | 0.1 °C |
| Rotational Speed | 0.33 rpm |
| Air Flow Range | 0–1200 L/h (calibrated glass rotameter, 250 mm scale) |
| Air Pressure Range | 0–400 kPa (adjustable regulator with analog gauge) |
| Water Level Control | Automatic (optional AD1748-A00) |
| Air Diffusion | 20 alumina-based air diffusers in circular array |
| Compliance | ASTM D1748, IP 366 |
| Origin | Switzerland |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported |
| Model | D130 |
| Pricing | Upon Request |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | D873 |
| Pricing | Upon Request |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Standard Compliance | ASTM D86, IP 123, ISO 3405 |
| Model | 1000 Series |
| Configuration | Atmospheric Distillation Only |
| Heating Control | Electronically Adjustable Heating Plate |
| Condenser Type | Water-Cooled Chromium-Plated Copper Tube Assembly |
| Construction Material | Stainless Steel (Heater & Condenser Units) |
| Distillation Flask Options | 100 mL (Type A), 125 mL (Type B), 200 mL (Type C), 250 mL (Type D) |
| Receiver Flask Options | 25 mL (Type A), 100 mL (Type B), 200 mL (Type C) |
| Temperature Measurement | ASTM/IP Certified Thermometers (e.g., ASTM 2C, 3C, 105C–107C) |
| Origin | Switzerland |
|---|---|
| Type | ASTM D92 Cleveland Open Cup Flash Point Tester |
| Temperature Range | +79 °C to +400 °C |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Probe | PT100 Platinum Sensor (1/10 DIN Class) |
| Sample Cup | ASTM D92 / IP 36–compliant dimensions and fill level markings |
| Heating System | Electronic heater with overtemperature protection |
| Repeatability & Reproducibility | Meets or exceeds ASTM D92 and IP 36 requirements |
| Dimensions (W×D×H) | 48 × 37 × 61 cm |
| Weight | 32 kg |
| Power Supply | 220 V ±15 %, 50/60 Hz |
| Ambient Operating Limit | ≤35 °C |
| Safety Certification | CE-marked |
| Origin | Switzerland |
|---|---|
| Type | ASTM D86 Compliant Manual Atmospheric Distillation System |
| Model | 1000 Series |
| Configuration | Modular (Heating Unit 990/A + Condensation Unit 990/B) |
| Compliance | ASTM D86, IP 62–88, ISO 3405 |
| Heating Control | Electronically Adjustable Stainless Steel Heating Plate |
| Condenser | Chrome-Plated Copper Tubing with Water-Circulated Jacket |
| Visibility | Front-Mounted Tempered Glass View Window |
| Bottle Capacity Options | 100 mL (Type A), 125 mL (Type B), 200 mL (Type C), 250 mL (Type D) |
| Receiver Volumes | 25 mL (Type A), 100 mL (Type B), 200 mL (Type C) |
| Temperature Measurement | ASTM/IP Calibrated Thermometers (ASTM 2C to 107C / IP 62C to 88C) |
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | D1160 |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Type | Automated Distillation Apparatus |
| Model | 3025 |
| Temperature Range | 0–420 °C |
| Volume Resolution | 0.01 mL |
| Distillation Rate Programmable | 2–15 mL/min |
| Compliance | ASTM D86, D850, D1078, D2892 |
| Receiver Chamber Heating | up to 60 °C |
| Safety Systems | Integrated N₂ fire suppression, optical level detection, real-time diagnostics |
| Software | LIMS-integrated, GLP-compliant data logging, ASTM repeatability/reproducibility calculation |
| Network Capacity | Up to 32 units via Ethernet |
| Power Supply | 230 V, 50/60 Hz, 10 A |
| Dimensions (L×W×H) | 53.3 × 54.6 × 70.5 cm |
| Net Weight | 91 kg |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | D2274 |
| Pricing | Available Upon Request |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Standard Compliance | ASTM D942, DIN 51808, IP 142 |
| Model | D942 |
| Maximum Pressure Rating | 180 psi |
| Sample Capacity | 185 mL |
| Construction Material | Electropolished 18/8 Stainless Steel |
| Temperature Control | Digital PID Controller with PT100 Sensor, Over-Temperature Alarm |
| Bath Insulation | Dual-layer stainless steel housing with integrated heater |
| Brand | Fuland (csfriend) |
|---|---|
| Origin | Hunan, China |
| Model | FDY-0808 |
| Application Category | Laboratory Instrument for EV Thermal Management Fluid Evaluation |
| Compliance Standard | GB/T 29743.2 Annex C |
| Temperature Range | 0–100 °C (±1 °C accuracy) |
| Flow Rate | ≥30 L/min (adjustable, resolution 0.1 L/min) |
| Pressure Range | 0–500 kPa |
| Maximum Runtime | 9999 h (programmable, supports 1064 h continuous test cycles) |
| Data Storage Capacity | >200 test records |
| Pump Type | High-Temperature Automotive Electronic Water Pump (head ≥11 m, inlet/outlet diameter 20 mm) |
| Test Components | Aluminum Battery Cold Plate (≥1 m²), Aluminum Motor Housing with Integrated Cooling Channels, Aluminum Electronic Control Cooling Module |
| Fluid Path Material | Stainless Steel Fittings with Visual Observation Window |
| Thermal Insulation | Multi-layer External Jacket (reduces surface temperature & external thermal radiation) |
| Brand | Furand (csfriend) |
|---|---|
| Model | FDR-2271 |
| Instrument Class | 0.05 |
| pH Range | 0.00–14.00 pH |
| mV Range | −1800.0 to +1800.0 mV |
| Temperature Range | −5.0 to 105.0 °C |
| pH Resolution | 0.01 pH |
| mV Resolution | 0.1 mV |
| Temperature Resolution | 0.1 °C |
| pH Accuracy | ±0.01 pH ±1 digit |
| mV Accuracy | ±0.03% FS |
| Temperature Accuracy | ±0.3 °C ±1 digit |
| Burette Capacity Tolerance | ±0.025 mL (10 mL), ±0.035 mL (20 mL) |
| Burette Resolution | 1/10000 (10 mL), 2/10000 (20 mL) |
| Burette Fill/Dispense Time | 50 ±10 s (full scale) |
| Repeatability | 0.2% RSD |
| Endpoint Detection Sensitivity | ±2 mV |
| Drift Stability | ±0.3 mV ±1 digit / 3 h |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Dimensions (W×D×H) | 340 × 400 × 400 mm |
| Weight | 10 kg |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP737 |
| Pricing | Upon Request |
| Measurement Range | 0.0 °C to 1372 °C |
| Temperature Resolution | 0.1 °C (0.0–999.9 °C), 1 °C (>999.9 °C) |
| Temperature Accuracy | ±0.2% of reading |
| Ambient Operating Temperature | ≤30 °C |
| Relative Humidity | 10–70% RH |
| Storage/Transport Temperature | −25 °C to +55 °C |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Max. Power Consumption | ≤2 kW |
| Dimensions (H×W×D) | 500 mm × 400 mm × 360 mm (main unit) |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP656 |
| Heating Power | 200 W |
| Temperature Control Accuracy | ≤ ±1 °C |
| Magnetic Stirring Power | 3 W |
| Electric Stirring Power | 30 W |
| Magnetic Stirring Speed Range | 0–2400 rpm |
| Electric Stirring Speed Range | 0–3000 rpm |
| Total Power Consumption | ≤ 1200 W |
| Supply Voltage | AC 220 V ±10%, 50 Hz ±10% |
| pH Measurement Range | 0.00–14.00 pH |
| pH Accuracy | ±0.02 pH |
| pH Resolution | 0.01 pH |
| pH Repeatability | ≤1% |
| pH Stability | ±1% F.S./4 h |
| pH Response Time (T90) | <1 min at 25 °C |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Compensation Range | 0.1–60.0 °C |
| Sample Temperature Range | 5–60 °C |
| Operating Ambient Temperature | 5–40 °C |
| Relative Humidity | ≤85% |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERAFLASH |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automatic |
| Applicable Standards | ASTM D6450, ASTM D7094, SH/T 0768 |
| Repeatability | Excellent |
| Ignition Method | Electric Arc Ignition |
| Temperature Range | −25 °C to 420 °C (standard configuration: 0 °C to 200 °C |
| Sample Volume | 1 mL (ASTM D6450), 2 mL (ASTM D7094) |
| Cooling/Heating Technology | Patented PBT (Peltier-Based Thermoregulation) |
| Data Storage Capacity | >100,000 test reports with full audit trail |
| Power Supply | 85–264 V AC or 12 V DC |
| Sample Throughput | Up to 12 samples/hour |
| Temperature Accuracy | ±0.1 °C |
| Integrated Pollution Monitoring | CPT (Contamination Prevention Technology) |
| Optional Modules | EF01-HTM (high-temp module, up to 420 °C), EF02 LT (low-temp module, −40 °C to 120 °C with external chiller) |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERAFLASH |
| Detection Method | Closed Cup |
| Operation Mode | Automatic |
| Temperature Range | −40 °C to 200 °C (optional high-temp module up to 420 °C |
| LT module with external cooling | −40 °C to 120 °C) |
| Ignition Source | Electric Arc |
| Repeatability | ±4.1 °C |
| Compliance Standards | ASTM D6450, ASTM D7094, SH/T 0768–2005 |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | Eraflash S10 |
| Detection Method | Closed-Cup (ASTM D93 / ISO 2719 / IP 34 / GB/T 261 / SH/T 0768) |
| Temperature Range | −25 °C to 200 °C (optional high-temp module up to 420 °C) |
| Temperature Accuracy | ±0.1 °C |
| Test Duration | 3–5 min per sample (including cup cleaning) |
| Sample Volume | 1 mL or 2 mL |
| Auto-sampler Capacity | 10 positions |
| Data Storage | 100,000 test records |
| Display | 7-inch full-color capacitive touchscreen (Chinese UI) |
| Interfaces | 3× USB, 1× Ethernet, 1× RS232, LIMS-compatible serial protocol |
| Power Supply | 85–263 VAC, 47–63 Hz, 70 W |
| DC Option | 12 V / 4 A |
| Dimensions | 220 × 320 × 280 mm |
| Weight | 8 kg |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | Eraflash X |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automatic |
| Temperature Range | 18 °C to 370 °C |
| Ignition Method | Electric Arc Ignition |
| Repeatability | High |
| Compliant Standards | ASTM D7094, SH/T 0768 |
| Sample Volume | 2 mL |
| Cooling/Heating Technology | Peltier-Based Thermoelectric (PBT) |
| Data Storage Capacity | >100,000 test reports |
| Throughput | Up to 12 samples/hour |
| Temperature Accuracy | ±0.1 °C |
| Power Supply | 85–264 V AC or 12 V DC |
| Pollution Control | CPT Electrode Protection & Self-Cleaning Ignition System |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | CRUDE |
| Analysis Method | Three-Stage Expansion Method |
| Pressure Range | 0–2000 kPa |
| Temperature Range | −20 to 120 °C |
| Compliance | ASTM D6377, D6378, D5191, D5188, D6897, GB/T 11059, SH/T 0769, SH/T 0794, SN/T 2932, EN 13016 |
| Sample Handling | Heated high-viscosity module, integrated oscillator, pure-sampling valve, automatic liquid/gas purge |
| Brand | ERALYTICS |
|---|---|
| Origin | Imported |
| Model | ERASPEC DIESEL |
| Measurement Principle | Mid-IR Fourier Transform Infrared (FTIR) Spectroscopy |
| Measurement Items | Cetane Number (CN), Cetane Index (CI), Fatty Acid Methyl Esters (FAME), Total Aromatics, Polycyclic Aromatic Hydrocarbons (PAH), Distillation Temperatures (T85, T90, T95), Cetane Improvers, Biodiesel Content, Fatty Acid Ethyl Esters (FAEE), Rapeseed Oil, Dimethoxymethane (DMM), etc. |
| Sample Volume | 10 mL |
| Analysis Time | ≤ 60 s |
| Portability | Fully Portable (Lab & Field-Deployable) |
| Spectral Range | 631–45890 cm⁻¹ |
| Spectral Resolution | 2 cm⁻¹ (data acquisition at 0.5 cm⁻¹) |
| Wavelength Accuracy | < 0.01 cm⁻¹ |
| Signal-to-Noise Ratio | > 10,000:1 |
| Density Measurement Accuracy | ±0.0001 g/cm³ |
| Data Storage Capacity | ~6,000 results |
| Power Supply | 85–264 VAC, 47–63 Hz, 70 W |
| DC Input | 12 V / 8 A (vehicle-compatible) |
| Dimensions | 290 × 350 × 340 mm |
| Weight | 9.7 kg |
| Compliance | GB/T 33648–2017 (detection of illegal diesel additives), EN 14078, GB 23801 |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERASPEC |
| Portability | Portable |
| Detection Principle | Mid-Infrared Spectroscopy |
| Measurement Range (Octane Number) | 70–105 |
| Accuracy | ±0.1 ON |
| Analysis Time | 60 seconds |
| Sample Volume | 10 mL |
| Compliance | GB/T 33648–2017 (Illicit Additives), ASTM D6227 (Benzene), ASTM D5845 (Oxygenates) |
| Spectral Range | 631–45,890 cm⁻¹ |
| Spectral Resolution | 2 cm⁻¹ |
| Wavenumber Accuracy | < 0.01 cm⁻¹ |
| Signal-to-Noise Ratio | > 10,000:1 |
| Built-in Density Measurement | ±0.0001 g/cm³ |
| Data Storage Capacity | ~6,000 results |
| Interface Options | 5× USB, 1× Ethernet, 1× RS232, LIMS-ready |
| Power Supply | 85–264 VAC / 47–63 Hz / 70 W or 12 VDC / 8 A (vehicle power) |
| Dimensions | 290 × 350 × 340 mm |
| Weight | 9.7 kg |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERASPEC JET |
| Application | Gasoline Octane Number and Diesel Cetane Number Analysis |
| Portability | Portable |
| Measurement Principle | Fourier Transform Infrared (FTIR) Spectroscopy |
| Measurement Range | 0–170 (Octane/Cetane Scale) |
| Accuracy | ±0.01 |
| Measurement Time | 60 s |
| Sample Volume | 10 mL |
| Spectral Range | 4000–400 cm⁻¹ |
| Data Points | Up to 3000 per spectrum |
| Density Measurement Accuracy | ±0.0001 g/cm³ (integrated Anton Paar density module) |
| Dimensions | 220 × 320 × 280 mm |
| Weight | 8 kg |
| Power Supply | 85–263 VAC, 47–63 Hz, 70 W |
| DC Input | 12 V / 4 A (vehicle-compatible) |
| Storage Capacity | ≥2000 test records |
| Interfaces | 3× USB, 1× Ethernet, 1× RS232, LIMS-ready |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERASPEC OIL |
| Compliance | ASTM E2412, D2688, D7412–D7418, D7624 |
| Measurement Principle | Mid-IR Absorption Spectroscopy with Fixed-Path Transmission Cell |
| Sample Volume | 10 mL |
| Flow Path Cell Thickness | 100 µm |
| Viscosity Range | 0–2000 cSt (at 20 °C) |
| Analysis Time | 60–120 s (viscosity-dependent) |
| Warm-up Time | ≤30 s |
| Auto-sampling | Integrated precision peristaltic pump |
| Auto-cleaning | Solvent or next-sample flush |
| Display | 7-inch capacitive touchscreen |
| Connectivity | Ethernet (RJ45), USB 2.0, RS-232 |
| Data Storage | ≥3000 full spectral reports with metadata |
| Remote Access | Yes, via Ethernet-enabled diagnostic and service interface |
| Alarm Logging | Timestamped event tracking with result correlation |
| Software Compliance | Audit-trail capable |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERASPEC OIL |
| Product Type | Portable Instrument |
| Detection Parameters | Oxidation, Nitration, Sulfation, Ester Degradation, Phosphorylation, Anti-wear Additives, Antioxidants, Water, Ethylene Glycol, Gasoline, Diesel, TAN, TBN, Viscosity (40 °C & 100 °C) |
| Compliance | ASTM E2412, ASTM D7412, D7414, D7415, D7418, D7624, JOAP, DIN 51452, DIN 51453 |
| Sample Volume | 10 mL |
| Spectral Range | 450–7000 cm⁻¹ |
| Data Points | 16,384 |
| Measurement Time | 60 s |
| Display | 7″ Color Touchscreen |
| Power Supply | 85–264 V AC / 12 V DC (7 A) |
| Dimensions | 22 × 32 × 28 cm |
| Weight | 8 kg |
| Interfaces | 5× USB, 1× Ethernet, 1× RS232, LIMS-ready |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | PYNN ERASPEC |
| Sample Volume | 10 mL |
| Measurement Time | 1 min |
| Spectral Range | 4000–400 cm⁻¹ |
| Spectral Resolution | 3000 data points per scan |
| Density Accuracy | ±0.0001 g/cm³ (integrated Anton Paar density module) |
| Power Supply | 85–263 VAC, 47–63 Hz, 70 W |
| DC Power Option | 12 V / 4 A |
| Dimensions | 220 × 320 × 280 mm |
| Weight | 8 kg |
| Connectivity | 3× USB, 1× Ethernet, 1× RS232, LIMS interface |
| Data Storage | ≥2000 test records |
| Display | 6.5″ color touchscreen (Chinese UI) |
| Compliance | ASTM D1655, ASTM D7462, ASTM D7845, ISO 13739, IP 359, DEF STAN 91-91 |
| Brand | ERALYTICS |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | ERAVAP |
| Analysis Method | Three-Stage Expansion Method |
| Pressure Range | 0–2000 kPa |
| Temperature Range | −20–120 °C |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERAVAP Online |
| Analysis Method | Three-Stage Expansion Method |
| Pressure Range | 0–2000 kPa |
| Temperature Range | 0–120 °C |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERAVISC X |
| Standards Compliance | ASTM D445, ASTM D7042, ASTM D4052, ASTM D5002, ISO 3104, ISO 23581, ISO 12185, ISO 2909, ASTM D2270, NB/SH/T 0870, SH/T 0604, SN/T 3518 |
| Viscosity Range | 1–1000 mm²/s |
| Density Range | 0–3 g/cm³ |
| Temperature Range (Viscosity) | 15–100 °C |
| Temperature Range (Density) | 0–100 °C |
| Repeatability | Equivalent to ASTM D445 & D7042 (viscosity), ±0.00001 g/cm³ (density) |
| Resolution | 0.01 mm²/s (viscosity), 0.00001 g/cm³ (density) |
| Temp. Accuracy | ±0.02 °C |
| Measurement Time | 60 s (viscosity), 15 s (density, post-equilibration) |
| Sample Volume | 3 mL |
| FillingProof™ Bubble Detection | Yes |
| Integrated Drying Pump | Yes |
| Data Storage Capacity | >100,000 test records |
| Interfaces | Ethernet, 4× USB (front/rear), RS-232 |
| Display | 8.4″ industrial-grade color touchscreen |
| Power | 85–264 V AC, 47–463 Hz, max. 150 W |
| Dimensions | 15.5 × 26 × 28 cm |
| Weight | 8 kg |
| Origin | Norway |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | F-100 |
| Pricing | Upon Request |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 000-001-305 |
| Test Method Compliance | ASTM D2670, D2625, D3233, D5620 |
| Load Range | 200–3000 lbf (±2% FS) |
| Rotational Speed | 290 ± 10 rpm |
| Torque Measurement | 0–100 in-lb (±2% FS) |
| Wear Resolution | 0.001 inch (0.025 mm) per 14.4 ratchet clicks |
| Operating Temperature | Ambient to 100 °C |