Physical Property Testing Instruments
Filter
Showing 3361–3390 of 4355 results
| Brand | PHYSIKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | CryoM |
| Quotation | Upon Request |
| Temperature Range | 1.5 K – 400 K |
| Magnetic Field Range | 9 T / 12 T / 14 T / 16 T |
| Brand | PHYSIKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PHY-CryoM |
| Pricing | Available Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | PICO-RHEED |
| Price | USD 220,000 (FOB Yokohama) |
| Key | Temperature Range: −40 °C to +150 °C (optional −120 °C to +150 °C) |
|---|---|
| Humidity Range | 30–98% RH (optional 5–98% RH) |
| Temp. Resolution | 0.01 °C |
| Humidity Resolution | 0.1% RH |
| Temp. Uniformity | ±0.5 °C |
| Temp. Deviation | ≤±2 °C |
| Humidity Deviation | ≤±2.5% RH |
| Heating Rate | 2.0–3.0 °C/min |
| Cooling Rate | 0.7–1.0 °C/min |
| Control System | TEMI880 color LCD touchscreen controller |
| Internal Construction | SUS304 stainless steel |
| Power Supply | 380 V ±5%, 50 Hz, 3P+N+G (custom 220 V available) |
| Brand | PMI Porometer / Porous Materials Inc. |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMP-60K-A-1 |
| Price | Upon Request |
| Pore Size Range | 3 nm – 500 µm (calculated per Washburn equation, dependent on mercury surface tension and contact angle) |
| Pressure Range | 0–60,000 psi (high-pressure station), 0–33,000 psi (dual-range configuration available) |
| Measurement Accuracy | Compliant with ASTM D4404 and ISO 15901-1 for mercury intrusion porosimetry |
| Sample Chamber Capacity | Standard 10 mL (customizable from 10–100 mL) |
| Number of Sample Stations | Single or dual chamber configuration |
| Intrusion Medium | High-purity mercury with isopropanol-assisted recovery system |
| Pressure Transducers | Triple-stage (low: 0–1000 Torr ≈ 20 psia |
| medium | 0–3000 psia |
| high | 0–60,000 psia) |
| Micrometered Dosing Tube Volume | Up to 2.1 cc (standard) |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 16,500 (approx.) |
| Compliance Standards | MIL-STD-810, GJB 150.18, GJB 360, IEC 60068-2-29, GB/T 2423.5–2012, GB/T 2423.6–2012 |
| Waveform Options | Half-sine, Trapezoidal, Post-peak Sawtooth |
| Control Mode | Closed-loop Acceleration Control for Collision Testing |
| Operating Pressure | 7–8 kgf/cm² (≈0.7–0.8 MPa) |
| Power Supply | AC 220 V ±5%, 50 Hz ±0.5 Hz, Single-phase Three-wire |
| Brand | Generic |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 16,500 (FOB) |
| Compliance | MIL-STD-810, IEC 60068-2-29, GB/T 2423.5–2022, GJB 150.18A–2012, GJB 360B–2009 |
| Brand | Porometer |
|---|---|
| Model | POROLIQ |
| Origin | Germany |
| Technology | Liquid-Liquid Displacement (LLP) |
| Measurement Principle | Capillary Flow Porometry via Immiscible Liquid Pair (e.g., Isopropanol/Water) |
| Minimum Detectable Pore Diameter | 2 nm |
| Data Acquisition Mode | Stepwise Pressure Ramp with Equilibrium Validation Algorithm |
| Compliance Framework | ASTM F316-22, ISO 15901-1, USP <801>, GLP/GMP-ready audit trail support |
| Brand | Porometer |
|---|---|
| Origin | Germany |
| Model | POROLUX BP |
| Pressure Range | 0–5 bar (0–75 psi) |
| Pore Size Detection Range | 0.13–300 µm |
| Measurement Principle | Bubble Point Method (Capillary Flow Porometry) |
| Compliance | ASTM F316-22, ISO 4003, USP <801> |
| Software | POROLUX Control Suite v3.x (GLP-compliant audit trail, user access levels, 21 CFR Part 11 ready) |
| Brand | Porometer |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | POROLUX Cito Series |
| Price Range | USD 14,000 – 140,000 |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Flow Range | 200 L/min |
| Pressure Range | 35 bar (500 psi) |
| Measurement Principle | Gas-Liquid Displacement Method (Capillary Flow Porometry) |
| Repeatability | ≤1% |
| Key | Brand: Porometer |
|---|---|
| Origin | Germany |
| Model | POROLUX Revo |
| Measurement Principle | Capillary Flow (Gas-Liquid Displacement) |
| Max Flow Rate | 200 L/min |
| Pressure Range | 35 bar (500 psi) |
| Repeatability | ≤1% |
| Minimum Pore Size | 13 nm |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Brand | Porometer |
|---|---|
| Model | POROLUX™ Revo X |
| Origin | Germany |
| Measurement Principle | Gas-Liquid Capillary Flow (Capillary Flow Porometry, CFP) |
| Pore Size Range | 80 nm – 500 µm |
| Bubble Point Pressure Range | 0–8 bar (0–116 psi) |
| Max. Gas Flow Rate | 200 L/min |
| Dual Auto-Switching Flow Sensors | 0–10 L/min & 0–200 L/min |
| Dual Auto-Switching Pressure Sensors | 0–1 bar & 0–10 bar |
| Sample Holder Diameter | 25 mm |
| Max. Sample Thickness | 3 mm |
| Measurement Modes | Bubble Point (BP x-mL, BP pCF), Mean Flow Pore Size, Minimum Pore Size, Pore Size Distribution, Cumulative Flow Distribution, Gas Permeability |
| Optional Modules | Liquid Permeability, Fluid Source Integration |
| Software | PoreSmart™ with Curve Fitting, Statistical Pore Quantification (Total Pore Count, Total Pore Area [% & µm²], Open Porosity, Calculated Permeability in Darcy) |
| Patented Measurement Method | MP² (Multi-Step Pressure Progression) Technology |
| Compliance Ready | ASTM F316-22, ISO 15709:2022, USP <801>, GLP/GMP Data Integrity Support (Audit Trail, Electronic Signatures, 21 CFR Part 11 Ready) |
| Brand | Tianyan (Shandong Tianyan) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TY-XXG2505 |
| Price | USD 2,950 (approx.) |
| Inspection Principle | Electromagnetic Yoke-Based Magnetic Particle Testing (MPI) with Directional Field Alignment for Ceramic Components |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Yoke Lifting Force | ≥10 kg (per ASTM E1444/E709) |
| Effective Penetration Depth | Up to 39 mm in ceramic tubing (verified per ISO 9934-1:2016 Annex B guidelines for non-ferromagnetic substrates with surface-breaking discontinuities) |
| Brand | POWEREACH |
|---|---|
| Model | JB04 |
| Origin | Shanghai, China |
| Light Source | 532 nm green laser (20 mW or 50 mW) |
| Laser Intensity Adjustment | 1–100% continuous |
| Objective Lens | Japanese MS-01 zoom objective, working distance 90 mm, magnification 700–1100 px/mm |
| Spatial Resolution | 2 µm |
| Incident Angle Range | 45°–60° |
| Polarization System | High-grade optical prism polarizer |
| Imaging Sensor | High-sensitivity CCD with electronic shutter |
| Image Acquisition | CG400 frame grabber card |
| Operating System Compatibility | Windows XP (32-bit), Windows 7 (32-bit) |
| Interface | RS232 serial port, native PCI slot required |
| Software | Proprietary GUI-based acquisition and analysis software |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Model | JBT07 Series |
| Measurement Range | 10–100 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.1 mN/m |
| Temperature Display Range | Ambient (20–25°C typical) |
| Temperature Resolution | ±0.1°C |
| Bubble Frequency Range | 0.06–66 bubbles/s (water reference) |
| Bubble Lifetime Range | 0.015–1 s (water reference) |
| Detection Method | Maximum Bubble Pressure (MBP) |
| Power Supply | AC 220 V / 110 V, 50 Hz |
| Power Consumption | 50 W |
| Interface | RS-232 Serial (DB9) |
| Brand | POWEREACH (Shanghai Zhongchen Digital Technology Equipment Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | JC2000C1 |
| Instrument Type | Benchtop Laboratory Contact Angle Measurement System |
| Measurement Modes | Static & Dynamic Contact Angle, Surface/Interfacial Tension (Sessile Drop & Pendant Drop), Surface Free Energy (Owens-Wendt Method) |
| Angular Range | 0–180° |
| Angular Resolution | 0.1° or 0.5° (selectable) |
| Image Magnification | 50–318 pixels/mm |
| Sample Stage Dimensions | 100 × 100 mm² |
| Vertical Stage Travel | 20 mm |
| Manual X/Y Stage Travel | 60 mm (X), 50 mm (Y) |
| Lens Translation Range | 40 mm (Z) |
| Imaging | USB Digital CCD Camera, 25 fps Real-Time Capture |
| Software | Proprietary Image Analysis Suite with Automated Tangent Fitting, Spline Curve Fitting (5-Point), Height-Method Calculation (3-/4-Point), and CMC/Surface Energy Modules |
| Brand | POWEREACH (Shanghai Zhongchen Digital Technology Equipment Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | JC2000C1 |
| Instrument Type | Benchtop Laboratory Goniometer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Resolution | 0.01° |
| Contact Angle Accuracy | ±0.1° or ±0.5° (selectable via tangent method) |
| Sample Stage Dimensions | 70 mm × 100 mm (fixed) |
| Maximum Sample Size (L×W×H) | ≤100 mm × ∞ × 25 mm |
| Maximum Sample Thickness | 25 mm |
| Image Magnification | 50–318 pixels/mm |
| Surface/Interfacial Tension Range (Pendant Drop Method) | 0.01–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Measurement Modes | Static contact angle, advancing/receding angle (via syringe infusion/withdrawal), dynamic contact angle, sessile drop, pendant drop, captive bubble |
| Software Analysis Methods | Tangent (3-/4-/5-point), circle/ellipse fitting, Young–Laplace curve fitting, Owens–Wendt two-liquid surface energy model |
| Imaging Capture Modes | Single-frame freeze, time-lapse (1–3600 s interval), high-speed video (30 fps) |
| Mechanical Adjustments | 4-axis manual stage (X/Y/Z + tilt) |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Benchtop Laboratory Goniometer |
| Measurement Principle | Video-based Optical Analysis with High-Resolution Imaging and Mathematical Droplet Contour Fitting |
| Contact Angle Range | 0–180° |
| Angular Resolution | 0.01° |
| Measurement Accuracy | ±0.1° or ±0.5° (selectable) |
| Sample Stage Dimensions | 70 mm × 100 mm |
| Vertical Stage Travel | 20 mm |
| Image Magnification | 70–420 pixels/mm |
| Camera | USB 2.0 Digital Industrial Camera with Sony CMOS Sensor |
| Optical System | 0.7×–4.5× Continuous Zoom Lens |
| Lighting | Adjustable High-Brightness LED Backlight |
| Measurement Modes | Sessile Drop, Pendant Drop, Captive Bubble, Tilting Plate |
| Contact Angle Analysis Methods | Tangent (θ), Height (θₕ), Elliptical Fitting, Young–Laplace Fitting, Five-Point Polynomial Fitting, Dual-Angle Asymmetric Analysis |
| Surface Tension Calculation | Axisymmetric Drop Shape Analysis (ADSA) via Pendant Drop Method |
| Surface Free Energy Models | Owens–Wendt (Two-Liquid), Wu Harmonic Mean, van Oss–Chaudhury–Good (vOCG), Acid–Base, Geometric Mean |
| Data Output | Excel (.xlsx), Image-Embedded Annotation, AVI Video Recording (25 fps), Audit-Trail-Ready Export Logs |
| Software Compliance | Supports GLP/GMP-aligned data integrity workflows |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JC2000D1 |
| Instrument Type | Benchtop Laboratory System |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Sample Stage Dimensions | 70 × 100 mm (expandable) |
| Image Magnification | 50–318 pixels/mm |
| Surface/Interfacial Tension Range (Pendant Drop Method) | 0.01–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Maximum Sample Size | 70 mm × 100 mm × 25 mm |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Model | JC2000E |
| Instrument Type | Benchtop Laboratory Goniometer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Resolution | 0.01° |
| Accuracy | ±0.1° |
| Sample Stage Dimensions | 100 mm × 100 mm |
| Image Magnification | 50–318 pixels/mm |
| Surface/Interfacial Tension Range (Sessile Drop & Pendant Drop Methods) | 0.01–2000 mN/m |
| Optical System | 0.7–4.5× Continuous Zoom Lens with Post-Magnification Optics |
| Camera Interface | USB 3.0 Digital CCD |
| Software | POWEREACH® V2.11 Image Analysis Suite |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Model | JC2000P |
| Instrument Type | Portable Video Optical Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Image Resolution | 1280×1024 pixels |
| Frame Rate | 30 fps |
| Light Source | Uniform High-Brightness LED with IR Filtering |
| Camera | 1.3-Megapixel USB 2.0 CCD with Real-Time Capture |
| Power Supply | USB 2.0 Bus-Powered or External AC 220 V / 50 Hz |
| Dimensions (W×D×H) | 240 × 200 × 300 mm (incl. handle) |
| Weight | 4 kg (incl. liquid reservoir) |
| Analysis Methods | θ/2 Method, Height Method (3-Point Planar / 4-Point Curved), 5-Point Curve Fitting (Advancing/Receding), Tangent Method |
| Measurement Modes | Static Contact Angle (Left/Right/Average), Dynamic Contact Angle, Droplet Volume & Diameter Quantification |
| Image Format | BMP |
| Video Format | AVI |
| Software | Proprietary Image Analysis Suite with Automated Edge Detection and Geometric Fitting Algorithms |
| Compliance | Designed for GLP-supporting workflows |
| Brand | POWEREACH (Shanghai Zhongchen Digital Technology Equipment Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | JC2000X1 |
| Instrument Type | Benchtop Dynamic Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.05° |
| Sample Stage Dimensions | 400 × 400 mm (Aerospace-Grade Aluminum) |
| Optical Magnification | 50–318 pixels/mm (0.7×–5× zoom) |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JC2000Y Series |
| Sample Stage | Circular, φ50–φ81 mm diameter, 5–30 mm thickness |
| Application Focus | Contact angle measurement on convex spherical lenses (glass & optical resin) |
| Compliance | Designed for ISO 19403-2, ASTM D7334, and GB/T 24368-2009 surface wettability testing protocols |
| Brand | POWEREACH |
|---|---|
| Model | JCJ04 |
| Type | Gravitational Sedimentation Particle Size Analyzer |
| Origin | Shanghai, China |
| Measurement Principle | Gravitational sedimentation (Stokes’ law-based) |
| Particle Size Range | 1–60 µm |
| Maximum Sample Mass Capacity | 0–100 g (selectable) |
| Sensitivity | 0.1 mg |
| Data Acquisition Interval | 0.5 s |
| Sample Vessel | 500 mL calibrated glass cylinder |
| Calibration Weights | 0.5 g, 10 g, 50 g, 100 g |
| Data Output | Real-time sedimentation curve, D10/D50/D90, mean diameter, particle size distribution histogram, cumulative distribution, error estimation |
| Software Functions | Auto-zero, tare, self-calibration, alarm threshold setting, curve storage/retrieval, statistical analysis, report generation & printing |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Model | JDF05 |
| Instrument Type | Coefficient of Friction Tester |
| Max. Friction Force | Not Specified |
| Friction Force Resolution | mN |
| Compliance | ASTM D1894, ISO 8295, GB/T 10006 |
| Software Interface | USB + RS232 (COM port required) |
| Data Acquisition | Real-time force-time curve, static/dynamic COF calculation |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Model | JDS05A |
| Instrument Type | Electromechanical Dual-Axis Tensile Testing System |
| Max Test Force per Axis | 500 N |
| Force Resolution | 1/10000 FS |
| Image Magnification | Up to 8 pixels/µm |
| Displacement Resolution | 0.001 mm |
| Travel Range | Not specified |
| Compliance | ASTM D5035, ISO 13934-1, GB/T 3923.1, AATCC 207 |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Model | JDS05B |
| Instrument Type | Electromechanical Dual-Axis Tensile Testing System |
| Max. Biaxial Load Capacity | 500 kg (≈4.9 kN per axis) |
| Load Resolution | 1/10,000 FS |
| Travel Range | Not specified |
| Displacement Resolution | Not specified |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JDS05C |
| Instrument Type | Electromechanical Triaxial Testing System |
| Max Biaxial Tensile Force | 4.0–5.0 kN (per axis) |
| Max Punching Force (Z-axis) | 2.0 kN |
| Displacement Resolution | 0.02 mm |
| Crosshead Speed Range | 0.8–2.0 mm/s |
| Max Travel per Axis | 300 mm |
| Load Cell Accuracy | ±1 N (with overload protection) |
| High-Speed Imaging | 30–200 fps CCD camera |
| Operating Environment | 8–30 °C, RH < 80% |
| Software Control | Real-time speed, stroke, and data acquisition via proprietary Windows-based interface |
| Compliance | Configurable to ASTM D5034, D5035, D638, ISO 13934-1, ISO 13935-1, GB/T 3923.1, and textile-specific GLP workflows |
| [Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JF99A |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Washburn Capillary Penetration Method |
| Contact Angle Range | 0–90° (calculated, relative) |
| Contact Angle Resolution | ±0.3° |
| Pressure Measurement Range | 0–330 mbar |
| Pressure Accuracy | ±0.16 mbar |
| Quartz Tube Dimensions | OD 10 mm / ID 8 mm or ID 6 mm |
| Sample Particle Size Requirement | ≤200 mesh (74 µm) |
| Surface Tension Range | 0.01–2000 mN/m |
| Image Magnification | 0.7×–5× (50–318 pixel/mm) |
| Stage Size | 120 × 120 mm |
| Power Consumption | <20 W |
| Dimensions (W×D×H) | 295 × 240 × 260 mm] |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Model | JJ2000B |
| Measurement Range | 10⁻⁶ mN/m to 100 mN/m |
| Resolution | 0.001 mN/m |
| Accuracy | <2% from 100 mN/m to 10⁻² mN/m |
| Rotational Speed Range | 2000–10,000 rpm |
| Speed Stability | ±0.1% |
| Capillary Inner Diameter | 2 mm / 4 mm |
| Temperature Control Range | Ambient to 95 °C |
| Camera | USB 2.0 industrial digital camera, 60 fps |
| Light Source | 12 V flat-panel lamp (70 × 19 mm) |
| Magnification Options | 1× and 2× T-shaped optical heads |
| Power Consumption | <50 W |