| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LCM-2 |
| Pricing | Available Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LCM-3 |
| Pricing | Available Upon Request |
| Key | Max Load: 50 kN |
|---|---|
| Load Accuracy | ±1% FS |
| Speed Accuracy | ±1% |
| Resolution | 0.01 N |
| Test Speed Range | 10–500 mm/min |
| Compliance | GB/T 228.1–2022 (ISO 6892-1 equivalent) |
| Origin | Jilin, China |
| Configuration | Standalone benchtop system with integrated controller and thermal printer |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Instrument Type | Oxygen Bomb Calorimeter |
| Measurement Mode | Isoperibol |
| Temperature Range | 0–80 °C |
| Temperature Resolution | 0.0001 °C |
| Precision | ≤0.10% RSD |
| Single-Sample Analysis Time | ≤5.5 min |
| Heat Capacity Calibration Range | 35,000 kJ/kg |
| Outer Water Jacket Volume | 12 L |
| Inner Water Bucket Volume | 6 L |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Product Type | Imported Instrument |
| Model | AMH55 |
| Instrument Category | Microhardness Tester |
| Measurement Range | 0–2000 HV (typical for Vickers microhardness) |
| Total Test Force | 1–60 kgf |
| Test Space (X × Y) | 260 × 150 mm |
| Automation Level | Fully Automated / Semi-Automated / Lite Configurations Available |
| Software Platform | Cornerstone® v5.0+ |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TGA701 |
| Pricing | Available Upon Request |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | TGA801 |
| Price | Upon Request |
| Temperature Range | 100 °C to 1000 °C |
| Temperature Accuracy | ±0.5 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | Up to 15 K/min |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Temperature Range | −70°C to +180°C |
| Thermal Transition Time (5 min) | ≤15 s (air-to-air) |
| Recovery Time (after door opening) | ≤3 min |
| Control System | TEMI880 color touchscreen PLC controller (English/Chinese switchable) or TEMI300 membrane-key programmable controller (English only) |
| Refrigeration | Twin-stage or cascade refrigeration system with original French Tecumseh/Tecumseh-derived hermetic compressor |
| Heating | Nickel-chromium alloy wire heater |
| Humidification | Surface evaporation type |
| Air Circulation | Wide-band forced convection via centrifugal blower (top discharge / bottom intake) |
| Insulation | Polyurethane rigid foam (≥100 mm) + ultra-fine glass fiber |
| Inner Chamber Material | SUS304 stainless steel |
| Outer Chamber Material | Cold-rolled steel with electrostatic powder coating or optional SUS304 brushed finish |
| Door Seal | Dual-layer high-temp/low-temp resistant silicone rubber gasket |
| Standard Ports | One Ø50 mm test port (left side), dual-pane tempered observation window, two adjustable sample racks, fluorescent interior lighting, four swivel casters, integrated humidifier tank, RS485/RS232 communication interface |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 12,500 (FOB Shanghai) |
| Internal Dimensions (W×H×D) | 40×35×30 cm to 70×60×60 cm |
| Temperature Range | Hot Zone: RT to +200 °C |
| Cold Zone | RT to −70 °C |
| Test Zone | +60 °C to +150 °C (Hot Shock), 0 °C to −65 °C (Cold Shock) |
| Switching Mechanism | Pneumatic Air-Door Isolation (Static Specimen) |
| Recovery Time | <5 min |
| Temp. Uniformity | ±2.0 °C |
| Temp. Stability | ±0.5 °C |
| Refrigeration | Dual-Stage Cascade System (R404A/R23), Water-Cooled, German Semi-Hermetic Compressors |
| Construction | Interior – Mirror-Finish SUS304 Stainless Steel |
| Insulation | High-Density Fire-Retardant PU Foam |
| Compliance | GB/T 2423.1–2001, GB/T 2423.2–2001, GB/T 2423.22–2002, GJB 150.3–1986 / 150.4–1986 / 150.5–1986, IEC 60068-2-14 (Test N), MIL-STD-810G Method 503.5, EIA-364-32, QC/T 17–1992 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,100 (FOB) |
| Temperature Range | −70 °C to +150 °C |
| Humidity Range | 20–98% RH |
| Control Accuracy | ±0.5 °C / ±2.5% RH |
| Uniformity | ±1.5 °C / ±3% RH |
| Ramp Rate (Typical) | 1–3 °C/min (air average, unloaded, 25 °C ambient) |
| Compliance | GB/T 5170.2–1996, GB/T 5170.5–1996, GB 2423.1–1989, GB 2423.2–1989, GB 2423.22–1987, GB 10589–1989, GB 10592–1989, GB 11158–1989 |
| Brand | OK Instruments |
|---|---|
| Model Series | OK-STH-100 / OK-STH-225 / OK-STH-500 / OK-STH-800 / OK-STH-1000 |
| Internal Dimensions (D×W×H, mm) | 450×450×500 |
| External Dimensions (D×W×H, mm) | 1100×750×1000 |
| Temperature Range | −70 °C to +150 °C |
| Humidity Range | 20 %RH to 98 %RH |
| Temperature Uniformity | ±2 °C |
| Humidity Uniformity | ±3 %RH |
| Temperature Fluctuation | ±0.3 °C |
| Humidity Fluctuation | ±2.5 %RH |
| Control Resolution | 0.1 °C / 0.1 %RH |
| Heating System | Nickel-Chromium Alloy Tubular Heaters |
| Refrigeration System | Hermetic French Tecumseh or Semi-Hermetic German Copeland Compressors |
| Refrigerants | R23 / R404A |
| Cooling Method | Air-Cooled |
| Humidity Generation | Steam Humidification with Auto-Water Recovery & Filtration |
| Air Circulation | Wide-Band Forced Convection (Top-Exit / Bottom-Intake) |
| Controller | TEMI880 Korean LCD Touchscreen (Bilingual English/Chinese Interface) |
| Programmable Memory | 120 Programs × 999 Segments |
| Communication | RS-232 Serial Interface |
| Safety Protections | Over-Temperature Cut-Off, Dry-Run Prevention, Water-Level Monitoring, High-Pressure & Phase-Loss Protection, Leakage Current Detection, Thermal Fuse, and Self-Diagnostic Alarms |
| Insulation | High-Density Polyurethane Foam + Ultra-Fine Glass Wool |
| Interior Material | Mirror-Finish SUS304 Stainless Steel |
| Exterior Material | Brushed SUS304 Stainless Steel or Rust-Protected Cold-Rolled Steel |
| Standard Accessories | Single Observation Window, One Ø50 mm Test Port, Two Adjustable Sample Shelves, Fluorescent Illumination, Integrated Water Reservoir with Filtration |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 12,500 (FOB) |
| Chamber Configuration | Two-Zone or Three-Zone Thermal Shock System |
| Internal Volume Options | 49 L / 80 L / 150 L / 225 L |
| Temperature Range | High Zone: RT to +200 °C |
| Low Zone | RT to −70 °C |
| Test Zone | Thermal Shock from +60 °C to +150 °C (Hot Soak) and 0 °C to −65 °C (Cold Soak) |
| Switching Mechanism | Pneumatic Air-Door Isolation (Static Specimen) |
| Recovery Time | ≤5 min |
| Temperature Uniformity | ±2.0 °C |
| Control Accuracy | ±0.5 °C |
| Refrigeration | Dual-Stage Cascade System with Semi-Hermetic German Compressors |
| Refrigerants | R404A (HT Stage) / R23 (LT Stage) |
| Insulation | High-Density Fire-Retardant PU Foam (≥150 mm Thickness) |
| Interior Material | Mirror-Finish SUS304 Stainless Steel |
| Exterior | SUS304 Stainless Steel or Powder-Coated Steel |
| Cooling Water Requirement | External 10 m³/h Closed-Loop Cooling Tower (User-Supplied) |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz, 3-Phase 5-Wire |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 12,500 (FOB) |
| Internal Dimensions (W×H×D) | 40×35×30 cm to 70×60×60 cm |
| External Dimensions (W×H×D) | 145×180×140 cm to 190×170×270 cm |
| High-Temp Reservoir Range | RT to +200 °C |
| Low-Temp Reservoir Range | RT to −70 °C |
| Test Zone Temperature Range | Hot Shock (+60 °C to +150 °C) |
| Switching Mechanism | Pneumatic Air-Damper–Actuated Static Specimen Method |
| Preheat Time (RT → 150 °C) | ≈30 min |
| Precool Time (RT → −70 °C) | ≈85 min |
| Recovery Time | <5 min |
| Temperature Control Accuracy | ±0.5 °C |
| Temperature Uniformity | ±2.0 °C |
| Refrigeration System | Dual-Stage Cascade with Semi-Hermetic German Compressor (R404A/R23) |
| Inner Chamber Material | Mirror-Finish SUS#304 Stainless Steel |
| Outer Chamber Material | SUS#304 Stainless Steel or Powder-Coated Steel |
| Insulation | High-Density Fire-Retardant PU Foam |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz, 3-Phase 5-Wire |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 4,100 (FOB) |
| Temperature Range | 105–132 °C (Control Point) |
| Temp. Uniformity | ±2.0 °C |
| Temp. Stability | ±0.5 °C |
| Humidity Control Point | 100 % RH |
| Humidity Stability | ±2.5 % RH |
| Humidity Uniformity | ±5.0 % RH |
| Pressure Range | 0.05–0.196 MPa (0.5–2 kgf/cm²) |
| Heating Time | 35 min (RT → 132 °C) |
| Pressurization Time | 40 min (Ambient → 0.196 MPa) |
| PID Temperature Control Accuracy | ±0.1 °C |
| Safety Features | Dual Overheat Protection, Interlocked Door Switch, Mechanical Safety Valve, Auto-Water Replenishment, Saturated Steam Purge System |
| Construction | ABS Insulated Door, Integrated Silicone Gasket, Stainless Steel Chamber |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pricing | USD 2,650 (FOB) |
| Temperature Range | −40°C to +150°C |
| Humidity Range | 20%–98% RH |
| Control Accuracy | ±0.5°C / ±2.5% RH |
| Uniformity | ±1.5°C / ±3% RH |
| Ramp Rate (Typical) | 3–5°C/min (air average, unloaded, 25°C ambient) |
| Cooling Water Requirement | 10–28°C, 0.1–0.3 MPa |
| Refrigerant | R404A (CFC-free) |
| Compressor | Tecumseh/Taikang hermetic scroll type |
| Noise Level | <60 dB(A) |
| Compliance | GB/T 2423.1–2023, GB/T 2423.2–2023, IEC 60068-2-1:2022, IEC 60068-2-2:2022, GJB 1032A–2021, MIL-STD-2164A–2018 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Controller Options | TEMI880 Color Touchscreen (EN/CN Switchable) or TEMI300 Membrane Keypad (English Only) |
| Protection Systems | Compressor Overheat/Overcurrent/High-Pressure, Dry-Heater Burnout Prevention, Chamber Over-Temperature, Low-Water Detection |
| Standard Features | Dual-Layer Tempered Glass Viewing Window, φ50 mm Cable Port (Left Side), Two Adjustable Sample Racks, Fluorescent Interior Lighting, Four Casters with Brakes, Removable Humidity Water Tank, RS485/RS232 Communication Interface, PC-Based Control Software |
| Temperature Control | Balanced Temperature & Humidity Control System (BTSC) |
| Operating Ambient | +5°C to +35°C |
| Heating | Nickel-Chromium Alloy Wire Heaters |
| Humidification | Surface Evaporation Type |
| Air Circulation | Wide-Range Forced Convection (Top-Down Flow), Multi-Blade Centrifugal Fan |
| Condensation | Air-Cooled |
| Refrigeration | Original French Tecumseh Hermetic Compressor |
| Refrigeration Circuit | Twin-Stage or Single-Stage Low-Temperature Loop Design |
| Construction | Outer Shell – SUS304B Stainless Steel |
| Airflow Uniformity | ±0.5°C Temp Deviation Across Working Volume (per IEC 60068-3-5) |
| Recovery Time | ≤3 min After Door Opening (from −40°C to +85°C at 50% RH) |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 12,500 (FOB) |
| Internal Dimensions (W×H×D) | 40×35×30 cm to 70×60×60 cm |
| Temperature Range (Hot Zone) | RT to +200 °C |
| Temperature Range (Cold Zone) | RT to −70 °C |
| Test Zone Range | +60 °C to +150 °C (hot shock) |
| Switching Mechanism | Pneumatic air-door, static sample placement |
| Recovery Time | <5 min |
| Temperature Uniformity | ±2.0 °C |
| Control Accuracy | ±0.5 °C |
| Refrigeration | Dual-stage cascade system with semi-hermetic compressors (R404A/R23) |
| Insulation | High-density fire-retardant PU foam |
| Interior Material | SUS#304 mirror-finish stainless steel |
| Exterior Material | SUS#304 stainless steel or powder-coated steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz, 3-phase 5-wire |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 12,500 (FOB) |
| Internal Dimensions (W×H×D) | 40×35×30 cm to 70×60×60 cm |
| Temperature Range | High Zone: RT to +200°C |
| Low Zone | RT to −70°C |
| Test Zone | +60°C to +150°C (hot shock), 0°C to −65°C (cold shock) |
| Transfer Mechanism | Pneumatic air-door switching (stationary test specimen) |
| Recovery Time | <5 min |
| Temperature Uniformity | ±2.0°C |
| Control Accuracy | ±0.5°C |
| Refrigeration | Dual-stage cascade system with semi-hermetic German compressors |
| Refrigerant | R404A/R23 |
| Insulation | High-density fire-retardant PU foam |
| Interior Material | Mirror-finish SUS304 stainless steel |
| Exterior | SUS304 or powder-coated steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz, 3-phase 5-wire |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 12,500 (FOB) |
| Internal Dimensions (W×H×D) | 40×35×30 cm to 70×60×60 cm |
| Temperature Range | High Zone: RT to +200 °C |
| Low Zone | RT to −70 °C |
| Test Zone | +60 °C to +150 °C (hot shock) |
| Switching Method | Pneumatic damper–actuated air valve |
| Recovery Time | <5 min |
| Temp. Uniformity | ±2.0 °C |
| Temp. Control Accuracy | ±0.5 °C |
| Refrigeration | Dual-stage cascade system with semi-hermetic compressors (R404A/R23) |
| Construction | Interior—SUS304 mirror-finish stainless steel |
| Insulation | High-density fire-retardant PU foam |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz, 3-phase 5-wire |
| [Brand | Other brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General distributor |
| Price | USD 12,500 (approx.) |
| Internal Dimensions (W×H×D) | 40×35×30 cm to 70×60×60 cm |
| External Dimensions (W×H×D) | 145×180×140 cm to 190×170×270 cm |
| High-Temperature Storage Range | RT to +200°C |
| Low-Temperature Storage Range | RT to –70°C |
| Test Zone Temperature Range | Hot Shock (+60°C to +150°C) |
| Switching Mechanism | Pneumatic damper actuation with stationary test specimen |
| Preheating Time (RT → 150°C) | ~30 min |
| Precooling Time (RT → –70°C) | ~85 min |
| Temperature Recovery Time | <5 min |
| Temperature Control Accuracy | ±0.5°C |
| Temperature Uniformity | ±2.0°C |
| Refrigeration System | Dual-stage cascade refrigeration with semi-hermetic compressors (R404A/R23) |
| Inner Chamber Material | SUS#304 mirror-finish stainless steel |
| Outer Chamber Material | SUS#304 stainless steel or powder-coated steel |
| Insulation | High-density fire-retardant PU foam |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz, 3-phase 5-wire] |
| Brand | Lei-Tech (LEI-TECH) |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | LK-HXBPRO |
| Instrument Type | Benchtop |
| Cooling Method | Air-Cooled |
| Temperature Range | Ambient (RT) to 65 °C |
| Humidity Range | 5–95% RH (Controlled) |
| Temperature Uniformity | ±0.1 °C |
| Temperature Stability | ±0.1 °C |
| Humidity Uniformity | ±3% RH |
| Humidity Stability | ±3% RH |
| Chamber Dimensions (W×D×H) | 128 × 86 × 22 mm |
| Brand | Lei-Tech |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Electromechanical Tensile Tester |
| Max Test Load | 0.5 kN / 5 kN |
| Force Range | 0–500 N / 0–5000 N |
| Force Resolution | 0.1 N / 1 N |
| Stroke | 40 mm / 70 mm |
| Displacement Resolution | 1 µm / 10 µm |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Oscillating U-Tube Densimeter |
| Portability | Portable |
| Sample Phase | Liquid |
| Application Focus | Petroleum Products Density Measurement |
| Density Range | 0.6–2.2 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Temperature Control Range | 15–40 °C (Peltier-regulated) |
| Temperature Accuracy | ±0.03 °C |
| Minimum Sample Volume | 1.5 mL |
| Compliance | ASTM D4052, ISO 12185, IP 365, GB/T 1884 |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Oscillating U-Tube Densimeter |
| Portability | Portable |
| Sample Phase | Liquid |
| Application Focus | Petroleum Products Density Measurement |
| Density Range | 0.6–2.2 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Temperature Control Range | 15–40 °C (Peltier-regulated) |
| Temperature Accuracy | ±0.03 °C |
| Minimum Sample Volume | 1.5 mL |
| Compliance | ASTM D4052, ISO 12185, IP 365, GB/T 1884 |
| Brand | LEMIS / LEMIS Baltic |
|---|---|
| Model | DM-230.2A |
| Density Range | 0.6500–1.1000 g/cm³ |
| Density Accuracy | ±0.0005 g/cm³ (typical, per ISO 12185) |
| Operating Temperature Range | −40 to +85 °C |
| Submersion Depth | Up to 30 m |
| Data Storage Capacity | 998 measurements |
| Wireless Interface | Integrated Bluetooth® 4.2 for PC and portable printer connectivity |
| Calibration Compliance | Traceable to NIST and PTB standards |
| Hazardous Area Certification | ATEX II 2G Ex ib IIB T4 Gb / IECEx Ex ib IIB T4 Gb |
| Regulatory Listing | Registered in the State Register of Measuring Instruments (Eurasian Economic Union) |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LMSM300/450 |
| Price Range | USD 6,800 – 13,600 |
| Measurement Range | 20 µm – 125 mm |
| Max Sample Capacity | 25 kg |
| Max Sieve Stack Levels | 9 (standard) / 17 (with extension kit) |
| Adjustable Base Acceleration | 1.0 – >10.0 g |
| Timer Range | 1–99 min |
| Intermittent Drive Interval | 10–99 s |
| Preset Method Storage | 9 profiles |
| Max Amplitude | 2.50 mm |
| Sieve Diameter Compatibility | 45, 75, 100, 150, 200, 203, 250, 315, 390, 400, 450 mm |
| Drive Principle | Electromagnetic resonance generating combined circular and vertical 3D throwing motion |
| Compliance | DIN EN ISO 9001 calibration support, CE certified |
| Power Supply | 230 V, 50 Hz, 300 VA |
| Net Weight (instrument only) | 40 kg |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | LH-010, LH-225 |
| Temperature Range | RT+10°C to 200°C |
| Temperature Uniformity | ≤ ±1.5°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Heating Rate | ~50 min (20°C → 200°C) |
| Air Exchange Rate | 10–300 cycles/hour (adjustable) |
| Sample Rack Rotation Speed | 10–12 rpm |
| Compliance | JB/T 7444–1994, IEC 60540 |
| Temperature Range | –40 °C to +150 °C (optional down to –120 °C) |
|---|---|
| Humidity Range | 30–98% RH (optional 5–98% RH) |
| Temperature Resolution | 0.01 °C |
| Temperature Uniformity | ±0.5 °C |
| Temperature Deviation | ≤ ±2 °C |
| Humidity Resolution | 0.1% RH |
| Humidity Deviation | ≤ ±2.5% RH |
| Cooling Rate | 0.7–1.0 °C/min |
| Heating Rate | 2.0–3.0 °C/min |
| Control System | TEMI880 Color LCD Touchscreen Programmable Controller |
| Power Supply | 380 V ±5%, 50 Hz, 3P+N+G (220 V optional) |
| Interior Material | SUS304 Stainless Steel |
| Exterior Material | SUS304 Stainless Steel or A3 Steel with Electrostatic Powder Coating |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, and 5.0 µm |
|---|---|
| Flow Rate | 2.83 L/min (0.1 cfm) |
| Sampling Time | 1 sec to 99 min 59 sec |
| Sampling Modes | Single, Repeat, Continuous, Calculate, Remote |
| Data Storage Capacity | 500 records |
| Display | 20-character × 4-line LCD |
| Interface | RS-232C or RS-485 (user-selectable via menu), RJ-11 for network daisy-chaining |
| Communication Baud Rate | 9600 bps |
| Power Supply | 4×AA Ni-MH batteries (4.8 V, 1.6 Ah), AC adapter (100–240 V input), dedicated charger required |
| Battery Life | ~3 hours continuous operation |
| Dimensions | 115 W × 70 D × 211 H mm |
| Weight | 980 g (body only, excluding batteries) |
| Operating Environment | 10–35 °C, non-condensing |
| Compliance | ISO 14644-1, FS-209E, JIS B9921, ISO 9001 & ISO 14001 certified, JQA-2790 / JQA-EM1628 validated |