| Brand | OEM / Custom Manufacturer |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | Custom-Engineered (OK-TH Series) |
| Price | USD 2,600–12,500 (FOB, based on configuration) |
| Internal Dimensions Range | 40×50×40 cm to 100×100×100 cm |
| Temperature Range Options | 0 to +150°C |
| Humidity Range | 20–98% RH (optional: 5–98% RH or 10–98% RH) |
| Temp. Uniformity | ±0.5°C |
| RH Uniformity | ±2.5% RH |
| Temp. Stability | ±2.0°C |
| RH Stability | +2 to +3% RH |
| Resolution | 0.1°C / 0.1% RH |
| Ramp Rate | Heating ~4.0°C/min |
| Refrigeration System | Hermetic low-noise dual-stage compressor with eco-friendly refrigerants (R404A/R23) |
| Controller | Full-color TFT touchscreen interface with bilingual (English/Chinese) navigation |
| Construction | Interior & exterior chambers fabricated from SUS#304 stainless steel |
| Viewing Window | Multi-layer tempered glass with embedded conductive ITO film for anti-fog observation |
| Sealing | Dual-layer high-tension silicone gasket at door interface |
| Access Port | One Ø50 mm test port (left side), pre-installed with brass gland fitting |
| Safety Systems | Real-time fault detection, over-temperature/over-humidity cutoff, compressor high-pressure protection, phase-sequence monitoring, and emergency power disconnect |
| Key | Controller: Siemens PLC + color LCD touch panel |
|---|---|
| Temp. setpoint accuracy | ±0.1 °C |
| Temp. indication accuracy | ±0.1 °C |
| Sensor | PT100 Ω platinum RTD |
| Heating | independent Ni-Cr alloy resistive heaters |
| Refrigeration | French Tecumseh hermetic air-cooled single-stage or cascade compressor system |
| Air circulation | low-noise HVAC-grade motor with multi-blade centrifugal impeller |
| Internal dimensions | 600 × 500 × 500 mm (W×H×D) |
| External dimensions | 1500 × 2100 × 2250 mm (W×H×D) |
| Construction | SUS304 stainless steel interior & exterior |
| Insulation | high-density glass wool + rigid polyurethane foam |
| Door | single pneumatic-assisted access door |
| Accessories | cryo/heat-resistant silicone packing (−200 °C to +400 °C), dual-zone auto-switching mechanism, two adjustable stainless steel test trays |
| Compliance | Designed per IEC 60068-3-5, ASTM D3418, and ISO 16750-4 environmental stress testing protocols |
| Brand | OEM / Custom Manufacturer |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price Range | USD 14,000–25,000 (FOB) |
| Temperature Range | −70 °C to +150 °C |
| Humidity Range | 20–98% RH (optional: 5–98% RH) |
| Ramp Rates | 5–25 °C/min (selectable) |
| Temp. Uniformity | ±2 °C |
| Temp. Stability | ±0.5 °C |
| Humidity Uniformity | ±3.0% RH (at ≥75% RH) |
| Humidity Stability | ±2.5% RH |
| Internal Dimensions (W×H×D, cm) | 50×75×60 / 60×85×80 / 100×100×80 / 100×100×100 |
| Test Port | Ø50 mm (left-side, sealed feedthrough) |
| Refrigerant | R507/R23 (zero ODP, low GWP HFC blend) |
| Control System | 7-inch color LCD touchscreen, bilingual (EN/CN), PID auto-tuning, 96 programmable test profiles |
| Safety Protections | Overcurrent, ground fault, compressor high-pressure/overheat, door interlock, over-temperature, leakage current, phase failure detection |
| Compliance | GB/T 2423.1–2023, GB/T 2423.2–2023, GB/T 2423.22–2012, GJB 150.3A–2009, GJB 150.4A–2009, GB/T 10589–2018, GB/T 11158–2012, GB/T 10592–2023 |
| Brand | OEM / Custom Manufacturer |
|---|---|
| Origin | Imported |
| Supplier Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Frequency Range | 1–5000 Hz |
| Amplitude (p-p) | 0–5 mm adjustable |
| Acceleration Range | 0–20 g (0–196.13 m/s²) |
| Maximum Sinusoidal Force | 2000 kgf (19.6 kN) |
| Frequency Resolution | 0.01 Hz |
| Sweep Mode | Linear & Logarithmic |
| Programmable Test Profiles | Yes |
| Time Setting Range | 1 s to 999 h 59 min 59 s |
| Power Consumption | 3.8 kW |
| Cooling Method | Natural Air Cooling |
| Operating Ambient | −10 °C to +60 °C, 10–95% RH (non-condensing) |
| Sound Pressure Level | ≤60 dB(A) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Model | Custom-Configurable |
| Price | USD 2,600 (approx.) |
| Internal Dimensions (W×H×D, cm) | 40×50×40 to 100×100×100 |
| External Dimensions (W×H×D, cm) | 100×165×100 to 180×200×180 |
| Temperature Range | 0°C to +150°C (Standard) |
| Humidity Range | 20–98% RH (Standard) |
| Temperature Uniformity | ±0.5°C |
| Humidity Uniformity | ±2.5% RH |
| Temperature Fluctuation | ±2.0°C |
| Humidity Fluctuation | +2–3% RH |
| Resolution | 0.1°C / 0.1% RH |
| Ramp Rate | Heating ~4.0°C/min |
| Refrigeration System | Hermetic, Low-Noise Dual-Stage Compressor with Eco-Friendly Refrigerants (R404A/R23) |
| Controller | Color Touchscreen LCD with English/Chinese Interface |
| Construction Material | SUS#304 Stainless Steel (Interior & Exterior) |
| Viewing Window | Multi-Layer Tempered Glass with Conductive Film |
| Test Port | One Ø50 mm Port (Left Side) |
| Safety Protection | Real-Time Fault Detection, Auto Power Cut-off, Over-Temperature/Humidity/Pressure Alarms |
| Brand | OEM / Private Label |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pricing | USD 2,650 (excl. tax & freight) |
| Temperature Range | -40°C to +150°C (standard) |
| Humidity Range | 20%–98% RH |
| Temperature Uniformity | ±0.5°C (at 25°C, unloaded) |
| Humidity Uniformity | ±3% RH (at 60% RH, unloaded) |
| Ramp Rate | 1–3°C/min (air average, load-dependent) |
| Cooling Water Requirement | 10–28°C, 0.1–0.3 MPa |
| Compliance | GB/T 2423.1–2023, GB/T 2423.2–2023, IEC 60068-2-1, IEC 60068-2-2, GJB 1032A–2021, MIL-STD-2164A |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 11,200 (approx.) |
| Brand | OEM / Custom Manufacturer |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| High/Low Temperature Range Options | A / B / C Configurations |
| Temperature Uniformity | ±2.0 °C |
| Transfer Time | ≤8 s |
| Recovery Time | ≤5 min |
| Inner Chamber Material | SUS304 Mirror-Finish Stainless Steel |
| Outer Chamber Material | SUS304 Brushed Stainless Steel |
| Insulation | Rigid Polyurethane Foam + High-Density Glass Fiber |
| Refrigeration System | French Tecumseh Compressor + Japanese/Italian Critical Components |
| Refrigerants | R404A & R23 (EPA SNAP-Approved, Non-Ozone-Depleting) |
| Safety Protections | Compressor High-Pressure / Overheat / Overcurrent |
| Brand | OEM / Custom Manufacturer |
|---|---|
| Origin | Imported (EU/US/Japan Sourced Components) |
| Supplier Type | Authorized Distributor |
| Power Supply | Customizable per client specification |
| Internal Dimensions (W×H×D, mm) | 500×600×500 |
| Temperature Range | −40 °C to +150 °C / −60 °C to +150 °C / −70 °C to +150 °C |
| Temperature Fluctuation | ±0.5 °C |
| Temperature Uniformity | ±1.5 °C |
| Temperature Deviation | ≤2 °C |
| Ramp Rate | 3–25 °C/min (linear, programmable) |
| Load Capacity | 5–50 kg aluminum mass |
| Control System | PID-based Balanced Temperature & Humidity Control (BTHC) |
| Refrigeration | Dual-stage mechanical cascade system with R404A/R23 refrigerants |
| Construction | Mirror-finish SUS304 stainless steel interior, insulated with high-density polyurethane foam + glass wool |
| Compliance | GB/T 2423.1–1989, GB/T 2423.2–1989, IEC 60068-2-1, MIL-STD-2164A, GJB 1032–1990 |
| Brand | OEM / Custom-Branded |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pricing | USD 11,200 (FOB) |
| Brand | OEM / Third-Party Manufacturer |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | −40 °C to +130 °C |
| Humidity Range | 20 %RH to 98 %RH |
| Temperature Uniformity | ±2 °C |
| Humidity Uniformity | ±3.0 %RH (steady-state) |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Fluctuation | ±2.5 %RH (steady-state) |
| Heating Rate | ~2.5 °C/min (air, no-load, non-linear) |
| Cooling Rate | ~1 °C/min (air, no-load, non-linear) |
| Internal Dimensions (W×D×H) | 3000 × 1000 × 2000 mm |
| External Dimensions (W×D×H) | 3800 × 1300 × 2450 mm |
| Door | Single outward-opening, 1000 × 1900 mm |
| Observation Windows | Front (300 × 450 mm), Left Side (500 × 450 mm) |
| Refrigeration | Mechanical compression refrigeration with water-cooling |
| Power Supply | 380 V ±10 %, 50/60 Hz |
| Total Power Consumption | ~30 kVA |
| Heat Load Capacity | 8.5 kW |
| Compliance | GB10589, GB10592, GB10586, GB11158, GB2423.1–GB2423.4, GB2423.22, GB/T5170.2, GB/T5170.5 |
| Temperature Range | -40 °C to +100 °C |
|---|---|
| Humidity Range | 30–98 %RH |
| Temperature Uniformity | ±0.5 °C |
| Temperature Deviation | ≤2 °C |
| Humidity Deviation | +2 to –3 %RH |
| Ramp Rate | 0.5–1.2 °C/min |
| Compliance | GB10589, GB10592, GB11158, GB/T5170.2, GB/T5170.5, GB2423.1/2/22, GB2424.1 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | -60°C to 100°C, -35°C to 100°C, or -20°C to 100°C |
| Humidity Range | 15–95% RH |
| Temperature Stability | ±0.5°C |
| Humidity Stability | ±2% RH |
| Temperature Uniformity | ±2°C |
| Humidity Uniformity | ±3% RH |
| Temperature/Humidity Deviation | ≤±2°C / ≤±3% RH |
| Refrigerant | R404A & R23 (Zero Ozone Depletion Potential, HFC-based) |
| Construction | Modular PU-insulated sandwich panels |
| Inner Wall | SUS304 stainless steel |
| Outer Wall | Color-coated steel sheet |
| Structural Frame | Standard galvanized angle iron & channel steel |
| Cooling System | Hermetic or semi-hermetic compressors with finned-tube evaporator (serving dual function as dehumidifier) |
| Heating System | Stainless steel finned-tube electric heaters |
| Humidification System | Stainless steel sheathed steam generator |
| Safety Protections | Fuseless overcurrent protection, compressor overheat/overpressure/overcurrent cutoff, dry-run protection for heaters & humidifiers, low-water-level alarm, explosion-proof interior lighting, power failure memory function |
| Controller | Large LED display, multi-function programmable controller with data logging capability (optional RS485/USB/Ethernet interface) |
| Standard Port | One φ50 mm test port |
| Power Supply | AC 3-phase 5-wire 380 V / 50 Hz |
| Air Delivery | Ceiling-mounted low-velocity laminar airflow design |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | Custom-Configurable |
| Price | USD 2,600–12,500 (FOB, based on configuration) |
| Internal Dimensions (W×H×D, cm) | 40×50×40 to 100×100×100 |
| External Dimensions (W×H×D, cm) | 100×165×100 to 180×200×180 |
| Temperature Range | –70 °C to +150 °C (selectable sub-ranges: 0 °C/+150 °C |
| Humidity Range | 20–98 %RH (optional: 5–98 %RH or 10–98 %RH) |
| Heating Rate | ≥4.0 °C/min (typical, 25 °C to +150 °C) |
| Cooling Rate | ≥1.0 °C/min (typical, 25 °C to –40 °C) |
| Temperature Uniformity | ±0.5 °C (at steady state, per IEC 60068-3-5) |
| Humidity Uniformity | ±2.5 %RH |
| Temperature Fluctuation | ±2.0 °C |
| Humidity Fluctuation | +2 to +3 %RH |
| Resolution | 0.1 °C / 0.1 %RH |
| Refrigeration System | Dual-stage hermetic scroll compressors (EU/US-sourced), R404A/R23 cascade refrigerant blend |
| Controller | 7-inch color TFT LCD touchscreen, programmable logic controller (PLC)-based, bilingual (English/Chinese) interface with real-time trend logging |
| Construction | Interior & exterior chambers fabricated from SUS#304 stainless steel |
| Viewing Window | Triple-layer insulated tempered glass with integrated ITO conductive film for anti-fog operation |
| Test Port | One Ø50 mm pass-through port (left side), sealed with silicone gasket |
| Safety Systems | Over-temperature, over-humidity, compressor high-pressure, phase failure, motor overload, and door-open interlock protection |
| Compliance | Fully engineered to meet IEC 60068-2-1 (Cold), IEC 60068-2-2 (Dry Heat), IEC 60068-2-30 (Cyclic Damp Heat), MIL-STD-810H Method 502.7 / 501.7 / 507.6, GB/T 2423.1–2023, GB/T 2423.2–2023, GB/T 2423.3–2016, GB/T 2423.4–2008, GJB 150.3A–2009, GJB 150.4A–2009, GJB 150.9A–2009 |
| Key | Brand: OEM/ODM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | Custom-Engineered |
| Temperature Range | -70°C to +150°C |
| Humidity Range | 20–98% RH (optional: 5–98% RH) |
| Temp. Uniformity | ±0.5°C |
| Humidity Uniformity | ±2.5% RH |
| Temp. Stability | ±2.0°C |
| Humidity Stability | +2–3% RH |
| Resolution | 0.1°C / 0.1% RH |
| Heating Rate | ~4.0°C/min |
| Cooling Rate | ~1.0°C/min |
| Construction | Interior & Exterior – SUS#304 Stainless Steel |
| Viewing Window | Multi-layer laminated tempered glass with conductive ITO film |
| Test Port | Ø50 mm (left-side, sealed) |
| Compressor | Original European/American fully-hermetic low-noise dual-stage unit |
| Refrigerant | R404A/R23 (environmentally compliant) |
| Controller | Full-color touchscreen HMI with EN/CN language toggle |
| Compliance | MIL-STD-810G (Method 501.6, 502.6), IEC 60068-2-1 (Cold), IEC 60068-2-2 (Dry Heat), IEC 60068-2-78 (Steady-State Damp Heat), IEC 60068-2-30 (Cyclic Damp Heat), GB/T 2423.1–2001, GB/T 2423.2–2001, GB/T 2423.4–1993, GJB 150.3–1986, GJB 150.4–1986 |
| Key | Max Load: 100 kg (customizable) |
|---|---|
| Frequency Range | 1–5000 Hz (0.01 Hz resolution) |
| Sweep Range | 1–5000 Hz (duration: 1 s to 30 days) |
| Peak-to-Peak Amplitude | 0–5 mm |
| Max Acceleration | 20 g |
| Vibration Axes | Vertical + Horizontal |
| Waveform | Sinusoidal |
| Programmable Segments | Up to 15 segments, each with user-defined frequency/time |
| Octave Sweeps | 5-segment logarithmic (low→high, high→low, low→high→low, repeatable) |
| Table Surface | 50 × 50 cm (customizable) |
| Cabinet Dimensions (Vertical Mode) | 50 × 20 × 50 cm (L×H×W) |
| Power Supply | 220 V ±20%, 5 A, 2.2 kW |
| Control Modes | Programmable, sweep, logarithmic, octave, amplitude/acceleration regulation, time-based termination |
| Compliance | Designed for IEC 60068-2-6, IEC 60068-2-64, MIL-STD-810H, ISO 16750-3, GB/T 2423.10, GB/T 2423.3, GB/T 2423.17 |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Frequency Range | 1–5000 Hz |
| Max. Acceleration | <20 g |
| Max. Displacement (p-p) | 0–5 mm |
| Load Capacity | 100 kg |
| Vibration Waveform | Sine (Half- or Full-Cycle) |
| Axis Configuration | Vertical + Horizontal (Dual-Axis Simultaneous or Independent Control) |
| Control Resolution | Frequency ±0.1 Hz, Display Resolution: 0.01 Hz |
| Power Supply | AC 220 V ±10% / 50 Hz or AC 380 V ±10% / 50 Hz |
| Operating Temperature | 5–40 °C (24-hr avg ≤25 °C) |
| Relative Humidity | ≤85% RH |
| Brand | DahoMeter |
|---|---|
| Origin | Guangdong, China |
| Model | DA-300M109 |
| Instrument Type | Laboratory Benchtop Buoyancy-Based Density Meter |
| Sample Type | Solids (Rubber, Elastomers, Polymers, Composites, Ceramics, Metals, Powders) |
| Density Range | 0.001–99.999 g/cm³ |
| Density Resolution | 0.001 g/cm³ |
| Temperature Range | 0.0–100.0 °C |
| Minimum Sample Mass | 0.005 g |
| Maximum Capacity | 300 g |
| Measurement Medium | Water or User-Defined Liquid |
| Compliance | ASTM D297, GB/T 533, GB/T 9867, DIN 53516, ISO 4649, GB/T 1689, ISO 1817 |
| Data Output | RS-232C interface |
| Additional Functions | DIN Abrasion Volume, Akron Abrasion Loss, ARI Index, Volume Expansion Ratio, Foaming Ratio, Mass/Volume Change Rate, Binary Mixture Composition Estimation, Pass/Fail Auto-Judgment |
| Brand | Dantsin |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Galieo |
| Pricing | Upon Request |
| Brand | Davenport |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PETPlus |
| Pricing | Available Upon Request |
| Brand | DD KJ |
|---|---|
| Origin | Chongqing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YW-060 |
| Internal Volume | 60 L |
| Temperature Range (Chamber) | 35–55 °C |
| Temperature Range (Saturated Air Chamber) | 45–75 °C |
| Temperature Fluctuation | ≤ 0.5 °C |
| Temperature Uniformity | < 2 °C |
| Temperature Deviation | ±2 °C |
| Ramp-up Time to Operating Temperature | ≤ 60 min |
| Power Consumption | 1.0 kW |
| Supply Voltage | 220 V, 50 Hz |
| Internal Dimensions (W×D×H) | 600 × 400 × 400 mm |
| External Dimensions (W×D×H) | 1100 × 650 × 900 mm |
| Standard Accessories | V- and O-type Sample Racks |
| Compliance | ASTM B117, ISO 9227, JIS Z2243 |
| Brand | Defelsko |
|---|---|
| Origin | USA |
| Model | PosiTest F/G |
| Measurement Principle | Electromagnetic Induction (F-type) / Eddy Current (G-type) |
| F-Type Range | 0–2000 µm (0–80 mils) |
| G-Type Range | 0–200 µm (0–8 mils) |
| F-Type Accuracy | ±5 µm (≤100 µm), ±5% of reading (>100 µm) |
| G-Type Accuracy | ±1 µm (≤20 µm), ±5% of reading (>20 µm) |
| Probe Type | Permanent Magnet (F) / High-Frequency Eddy Current (G) |
| Compliance | ASTM D7091, ISO 2178, ISO 2360, SSPC-PA 2, GB/T 4956, GB/T 4957 |
| Power Source | None (magnet-driven) |
| Environmental Rating | IP65-equivalent robust housing |
| Calibration | NIST-traceable certificate supplied with each unit |
| Brand | Delta Instruments (delta17) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DELTA-gs001 |
| Price Range | USD 2,800 – 7,200 |
| Platform Dimensions | 700 mm × 800 mm |
| Max Load Capacity | 100 kg (customizable) |
| Peak Acceleration | Half-Sine: 30–600 g |
| Post-Peak Sawtooth | 30–100 g |
| Square Wave (optional) | 30–120 g |
| Pulse Duration | Half-Sine: 1–30 ms |
| Post-Peak Sawtooth | 6–18 ms |
| Square Wave (optional) | 6–18 ms |
| Acceleration Tolerance | ≤ ±10% |
| Velocity Change Tolerance | ≤ ±10% |
| Lateral Motion Ratio | ≤ 10% |
| Overall Dimensions | 1300 mm × 1200 mm × 2650 mm |
| Mass | 1800 kg |
| Data Acquisition Channels | 2 |
| Sampling Rate | 500 kHz |
| Max Measurable Acceleration | 5000 g |
| Input Voltage Range | ±10 V<sub>PEAK</sub> |
| Sensor Type | Piezoelectric Charge Output |
| Sensor Model | B&W 22100 |
| Sensitivity | 3.93 pC/g |
| Frequency Range | 0.5–12 kHz |
| Acceleration Range | ±2500 g |
| Operating Environment | −40 °C to +160 °C |
| Power Supply | 3-phase AC 380 V ±10%, 5 kVA |
| Compressed Air | 0.5–0.8 MPa |
| Ambient Temp | RT–40 °C |
| Relative Humidity | <85% RH at 25 °C |
| MTBF | ≥5000 h |
| Half-Sine Generator Duty Cycle | ≥8000 consecutive impacts |
| Storage Life (clean, ambient conditions) | ≥5 years |
| Compliance | GB/T 2423.5–1995, GJB 150.18A–2009, GJB 360B–2009, IEC 60068-2-27, MIL-STD-810H, MIL-STD-202G, GB/T 18287, GB 31241, JG 541–2005 |
| Software Functions | Shock Response Spectrum (SRS), Pulse Analysis, Damage Boundary Analysis, Time-Domain Impact Response Calculation, FFT, Force–Deformation Correlation (auxiliary) |
| Brand | DELTA Instruments |
|---|---|
| Model | DELTA-SBT50 |
| Type | Electro-Mechanical Shock Test Table |
| Max Load Capacity | 50–500 kg |
| Standard Waveform | Half-Sine Pulse |
| Compliance | GB/T 2423.5, GB/T 2423.6, IEC 60068-2-29, GB/T 31467.3, JJG 497 |
| Control System | PC-Based Closed-Loop Digital Control with Real-Time Acceleration Feedback |
| Pulse Duration Adjustment | Via Interchangeable Anvil Pads |
| Peak Acceleration Adjustment | Via Adjustable Drop Height |
| Automated Stop | After Predefined Impact Count or Time Duration |
| Data Acquisition | Integrated Accelerometer, Velocity Change (Δv), Pulse Width, and G-Value Normalization |
| Safety | Mechanical Locking Mechanism for Anvil Pad Replacement |
| Dual-Mode Operation | Shock (Single-Impact) and Bump/Collision (Repetitive Impact) Modes |
| Software Features | Real-Time Waveform Display, Tolerance Band Overlay, Exportable CSV/PDF Reports, Audit-Trail-Ready Logging (GLP-Compatible) |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | DELTA1111 |
| Quotation | Available upon Request |
| Test Standards | ISO 6925, CFR 1630/1631, BS 6307, BS 4790, GB/T 20394–2013, GB/T 11049–2008, GB/T 14768–2015 |
| Sample Size | 230 mm × 230 mm (8 specimens per test) |
| Heating Source | Hot Metal Nut Method & Hexamethylenetetramine (Urotropine) Pellet Method |
| Ignition | Automatic Pulse Ignition |
| Timing Range | Flame Application Time: 0–99 s/min |
| Flame Application & Withdrawal Interval | 1.0–999.9 s (digital preset) |
| Afterflame Time | 1.0–999.9 s (digital readout) |
| Repetition Cycles | 1–9999 (digital preset) |
| Test Chamber Dimensions | 300 mm × 300 mm × 300 mm (W×D×H) |
| Ventilation Hood Volume | 2 m³ with Auto-Exhaust & Explosion-Proof Lighting |
| Exhaust Duct Diameter | Ø110 mm |
| Control System | PLC + 7-inch HMI Touchscreen |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Stainless Steel Hot Plate | 230 mm × 230 mm × 6.5 ±0.5 mm, central aperture Ø205 mm |
| Desiccant | Color-Indicating Silica Gel GPE0038 |
| Safety Features | Interlocked Protective Door, Black Interior Finish, Observation Window with Integrated LED Illumination |
| Brand | Derui Testing |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DR-D201-225E |
| Temperature Range | −60 °C to +150 °C |
| Refrigeration Method | Compressor-Based Cooling |
| Explosion-Proof Design | Yes (Class I, Division 1 compliant per GB/T 3836.1–2021) |
| Temperature Fluctuation | ±0.5 °C (empty chamber) |
| Temperature Deviation | ±2.0 °C (loaded, steady-state) |
| Temperature Uniformity | ±2.0 °C (empty chamber) |
| Heating Rate | ≤60 min (−60 °C to +150 °C) |
| Cooling Rate | ≤45/60/80 min (varies by target temperature span) |
| Interior Dimensions | 500 mm × 750 mm × 600 mm (W × H × D), dual-layer configuration |
| Effective Volume | 225 L (total, split across two independent zones) |
| Brand | Derui Testing |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DR-H202-V25 |
| Quotation | Upon Request |
| Internal Dimensions (W×D×H) | 2500 × 2200 × 2000 mm |
| Temperature Range | −40 °C to +150 °C |
| Temperature Uniformity | ±2 °C |
| Temperature Control Resolution | 0.1 °C |
| Heating Rate | 3 °C/min |
| Key | Temperature Range: –40 °C to +150 °C (standard) |
|---|---|
| Humidity Range | 30–98% RH (standard) |
| Temperature Resolution | 0.01 °C |
| Humidity Resolution | 0.1% RH |
| Temperature Uniformity | ±0.5 °C |
| Temperature Deviation | ≤±2 °C |
| Humidity Deviation | ≤±2.5% RH |
| Heating Rate | 2.0–3.0 °C/min |
| Cooling Rate | 0.7–1.0 °C/min |
| Control System | TEMI880 color LCD touchscreen programmable controller |
| Power Supply | 380 V ±5%, 50 Hz, 3P+N+G (customizable to 220 V) |
| Interior Material | SUS304 stainless steel |
| Exterior Material | SUS304 stainless steel or A3 steel with electrostatic powder coating |
| Key | Brand: OEM/Third-party Manufacturer |
|---|---|
| Origin | Imported |
| Supplier Type | Distributor |
| Price | USD 5,300–12,800 (FOB) |
| Chamber Volume | 100–1000 L |
| Spectral Range | 300–1200 nm |
| Irradiance Control | 550 W/m² (300–800 nm) ±10% |
| Black Panel Temperature Range | 40–85°C |
| Cabinet Temperature Range | 0–150°C |
| Humidity Range (Light Cycle) | 20–75% RH |
| Humidity Range (Dark Cycle) | 20–98% RH |
| Temperature Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Temperature Accuracy | ±0.5°C |
| Humidity Accuracy | ±2.0% RH |
| Spray Duration | 1–999 min (intermittent/continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer mesh tray or 500 mm diameter rotating turntable (0–3 rpm) |
| Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ≈1500 h at nominal irradiance |
| Filter System | Daylight- and Window-glass-type optical filters |
| Construction | Interior – SUS304 stainless steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |