Physical Property Testing Instruments
Filter
Showing 991–1020 of 12254 results
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | Bettersize2000 |
| Price Range | USD 21,000–28,000 (FOB) |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.02–2000 µm |
| Repeatability | <0.5% (D50 of NIST-traceable standard reference material) |
| Measurement Time | ≤10 s per run |
| Laser Source | Imported fiber-coupled semiconductor laser (lifetime ≥25,000 h) |
| Optical System | Dual-lens design with auto-alignment |
| Detector Array | 90-element high-sensitivity photodiode array |
| Ultrasonic Power | 50 W |
| Circulation Tank Volume | 600 mL |
| Flow Rate | 3000–8000 mL/min |
| Operating System Compatibility | Windows XP/7/8/10 |
| Interface | USB 2.0/3.0 |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions & Weight | 800 × 500 × 410 mm, 45 kg |
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer | Bettersize Instrument Co., Ltd. |
| Model | Bettersize3000 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.01–3500 µm |
| Repeatability | ≤0.5% |
| Measurement Time | <10 s |
| Optical Principle | Mie Scattering (default), Fraunhofer Diffraction (optional), Dynamic Imaging |
| Detector Array | 96-element photodetector (forward, side, and backward angles) |
| Refractive Index Measurement | Yes (real & imaginary components) |
| Compliance | ISO 13320:2020, GB/T 19077–2024, GB/T 41949–2022, USP <429>, EP 2.9.38, ChP 0982, FDA 21 CFR Part 11 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | BFT |
| Pricing | Available Upon Request |
| Compliance | ASTM D4151 |
| Construction | Stainless Steel Enclosure with Tempered Glass Viewing Window |
| Ignition Source | No. 18 Needle Burner (Adjustable Flame Height) |
| Timing Resolution | 0.01 s |
| Accessories | Standardized Brushing Device, Sample Holder Assembly, Stainless Steel Specimen Clamps |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | XG5010 |
| Price Range | USD 28,000 – 70,000 |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | FD |
| Temperature Range | Ambient + 5 °C to 300 °C |
| Internal Volume | 20 L (FD 23) |
| External Dimensions (W×H×D) | 435 × 495 × 520 mm |
| Internal Dimensions (W×H×D) | 222 × 330 × 300 mm |
| Net Weight | 27 kg |
| Heating Technology | PAT.line™ Preheating Chamber |
| Air Circulation | Adjustable forced convection |
| Exhaust Valve | Manually adjustable |
| Controller | Time-programmable digital controller with optical overtemperature alarm |
| Safety | Dual-stage temperature safety device (DIN 12880 Class 2) |
| Standard Accessories | 2 chrome-plated wire shelves |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model Series | KB PRO / KBF / KBF PRO with ICH or ICH-LQC Illumination Modules |
| Temperature Range (No Humidity Control) | +18°C to +32°C |
| Temperature & Humidity Range (KBF Series) | +20°C to +50°C / 20–50% RH |
| Extended Temp/Humidity Range (KBF PRO Series) | +10°C to +50°C / 10–80% RH |
| Compliance | ICH Q1B Option 2 (Visible Light) and UV Supplement via Fluorescent Lamps |
| Illumination Types | LED (visible spectrum) + T8 Fluorescent (UV-A/UV-B) |
| Optional Light Dose Control (LQC) | Yes |
| Chamber Volumes | 260 L, 470 L, 720 L |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Chamber Volumes | 260 L, 470 L, 720 L, 1060 L, 1600 L |
| Temperature Range (KB PRO) | 0 °C to +50 °C (no humidity control) |
| Temperature Range (KBF) | 10 °C to +50 °C, Humidity Range: 10–50 % RH |
| Temperature Range (KBF PRO) | 10 °C to +50 °C, Humidity Range: 10–90 % RH |
| LED System | 16 modular strips, each with independently controllable warm white (3000 K), cool white (6500 K), and deep red (660 nm) channels |
| PAR Irradiance | Up to 1000 µmol·m⁻²·s⁻¹ (simulating full sunlight) |
| Control Interface | Touch-enabled external controller with programmable light recipes, twilight simulation, and fresh-air exchange mode |
| Compliance | Designed per IEC 61000-6-3 (EMC), EN 61010-1 (safety), and compatible with GLP/GMP documentation workflows |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KB PRO Series |
| Temperature Range | –20 °C to +100 °C |
| Temp. Uniformity at 37 °C | ±0.2 K |
| Temp. Stability at 37 °C | ±0.1 K |
| Max. Heat Compensation at 37 °C | 450–1000 W |
| Recovery Time (30 s door opening, 37 °C) | 2–6 min |
| Internal Volume | 127–1610 L |
| Power Supply | 208–240 V, 50/60 Hz |
| Rated Power | 1.0–1.8 kW |
| Net Weight | 135–443 kg |
| Noise Level (25 °C) | 46–52 dB(A) |
| Refrigerant | R-290 |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Manufacturer | BINDER GmbH |
| Type | Upright Environmental Test Chamber |
| Condensation Method | Water-Cooled |
| Temperature Range | 0 °C to +70 °C |
| Humidity Range | 10 % RH to 80 % RH |
| Temperature Uniformity | ±0.1 °C |
| Humidity Uniformity | ±1.5 % RH |
| Interior Dimensions (W×D×H) | 1011 mm × 1250 mm × 847 mm |
| Refrigerant | R-600a |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Manufacturer | BINDER GmbH |
| Type | Upright Environmental Test Chamber |
| Cooling Method | Water-Cooled |
| Temperature Range | 0 °C to +70 °C |
| Humidity Range | 10 % RH to 80 % RH |
| Temperature Uniformity | ±0.1 °C |
| Humidity Uniformity | ±1.5 % RH |
| Interior Dimensions (W×D×H) | 1521 mm × 1250 mm × 847 mm |
| Energy Efficiency Improvement | 40 % vs. Previous Generation |
| Refrigerant | R-600a |
| Control System | Touchscreen Controller with Real-Time Segmented Programming |
| Compliance | ICH Q1–Q5, DIN 12880 Class 3.3, GLP/GMP-Ready Data Logging |
| Data Interface | Ethernet, USB |
| Software | APT-COM™ Basic Edition |
| Optional Modules | ICH Photostability Light Unit (for models ≥260), Plant Growth LED Module (for models ≥260) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Manufacturer | BINDER GmbH |
| Type | Upright Environmental Test Chamber |
| Cooling Method | Water-cooled |
| Temperature Range | 0 °C to +70 °C |
| Humidity Range | 10 % RH to 80 % RH |
| Temperature Uniformity | ±0.1 °C |
| Humidity Uniformity | ±1.5 % RH |
| Interior Dimensions (W×H×D) | 656 mm × 1250 mm × 575 mm |
| Energy Efficiency Improvement | 40 % vs. previous generation |
| Refrigerant | R-600a |
| Control System | Touchscreen-based APT.line™ Programmable Controller with Ethernet & USB interfaces |
| Safety Class | Temperature Safety Device Class 3.3 (DIN 12880) |
| Construction | Stainless Steel Interior, HIT Insulated Double-Wall Exterior |
| Optional Modules | ICH Photostability Light Module, Plant Growth LED Module |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Manufacturer | BINDER GmbH |
| Type | Upright Environmental Test Chamber |
| Model | KBF 720 |
| Temperature Range | 0 °C to +70 °C |
| Humidity Range | 10 % RH to 80 % RH |
| Temperature Uniformity | ±0.1 °C |
| Humidity Uniformity | ±1.5 % RH |
| Interior Dimensions (W×H×D) | 1011 mm × 1250 mm × 575 mm |
| Refrigerant | R-600a |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Manufacturer | BINDER GmbH |
| Type | Imported Instrument |
| Model | KBF PRO 1060 |
| Temperature Range | −20 °C to +100 °C |
| Humidity Range | 10 % RH to 98 % RH |
| Temperature Uniformity | ±0.1 K |
| Humidity Uniformity | ±1 % RH |
| Interior Dimensions (W × D × H) | 1011 mm × 847 mm × 1250 mm |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Manufacturer | BINDER GmbH |
| Type | Benchtop Environmental Test Chamber |
| Cooling Method | Water-cooled |
| Temperature Range | −20 °C to +100 °C |
| Humidity Range | 10 % RH to 98 % RH |
| Temperature Uniformity | ±0.1 °C |
| Humidity Uniformity | ±1 % RH |
| Interior Dimensions (W×D×H) | 656 mm × 500 mm × 386 mm |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | KBF PRO 1600 |
| Instrument Type | Upright Chamber |
| Condensation Method | Water-Cooled |
| Temperature Range | −20 °C to +100 °C |
| Humidity Range | 10 % RH to 98 % RH |
| Temperature Uniformity | ±0.1 K |
| Humidity Uniformity | ±1 % RH |
| Interior Dimensions (W × D × H) | 1521 mm × 847 mm × 1250 mm |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Manufacturer | BINDER GmbH |
| Type | Upright Environmental Test Chamber |
| Cooling Method | Water-cooled |
| Temperature Range | -20 °C to +100 °C |
| Humidity Range | 10 % RH to 98 % RH |
| Temperature Uniformity | ±0.1 °C |
| Humidity Uniformity | ±1 % RH |
| Interior Dimensions (W×D×H) | 656 mm × 695 mm × 575 mm |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Manufacturer | BINDER GmbH |
| Type | Upright Environmental Test Chamber |
| Model | KBF PRO 470 |
| Temperature Range | −20 °C to +100 °C |
| Humidity Range | 10 % RH to 98 % RH |
| Temperature Uniformity | ±0.1 K |
| Humidity Uniformity | ±1 % RH |
| Interior Dimensions (W × H × D) | 656 mm × 1250 mm × 575 mm |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Imported |
| Model | KBF PRO 720 |
| Instrument Type | Upright |
| Temperature Range | -20 °C to +100 °C |
| Humidity Range | 10 % RH to 98 % RH |
| Temperature Uniformity | ±0.1 K |
| Humidity Uniformity | ±1 % RH |
| Interior Dimensions (W × D × H) | 1011 mm × 1250 mm × 575 mm |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KBF PRO |
| Temperature Range | −20 to 100 °C |
| Humidity Range | 10–98 % RH |
| Temp. Uniformity (25 °C / 60 % RH) | ±0.2 K (KBF PRO 130 & 260), ±0.3 K (KBF PRO 470–1600) |
| Temp. Stability (25 °C / 60 % RH) | ±0.1 K |
| Humidity Stability (25 °C / 60 % RH) | ±1 % RH |
| Recovery Time (25 °C / 60 % RH, 30 s door open) | 1 min |
| Recovery Time (40 °C / 75 % RH, 30 s door open) | 3–5 min |
| Internal Volume | 127–1610 L |
| Power Consumption | 1.6–1.9 kW |
| Refrigerant | R-290 (eco-friendly hydrocarbon) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KBF Series |
| Type | Benchtop Environmental Test Chamber |
| Temperature Range | 0–70 °C |
| Humidity Range | 10–80 % RH |
| Temp. Uniformity (25 °C / 60 % RH) | ±0.1–0.4 K |
| Humidity Stability (25 °C / 60 % RH) | ±1.5 % RH |
| Recovery Time (25 °C / 60 % RH, 30 s door open) | 1–3 min |
| Power Consumption | 1.3–1.7 kW |
| Internal Volume | 127–1610 L |
| Refrigerant | R-600a |
| Compliance | DIN 12880, ICH Q1–Q5, GLP/GMP-ready |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Manufacturer | BINDER GmbH |
| Product Type | Imported Laboratory Environmental Chamber |
| Model | KBF-S ECO 400 |
| Temperature Range | 0 °C to +70 °C |
| Humidity Range | 10 % RH to 80 % RH |
| Temperature Uniformity | ±0.1 K at 25 °C / 60 % RH |
| Humidity Uniformity | ±0.1 % RH at 25 °C / 60 % RH |
| Interior Dimensions (W × D × H) | 485 mm × 650 mm × 1268 mm |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Manufacturer | BINDER GmbH |
| Type | Upright Environmental Test Chamber |
| Model | KBF-S ECO 720 |
| Cooling Method | Water-Cooled Peltier (Thermoelectric) |
| Temperature Range | 0 °C to +70 °C (at ambient ≤24 °C) |
| Humidity Range | 10 % RH to 80 % RH |
| Temperature Uniformity | ±0.1 K (at 25 °C / 60 % RH and 40 °C / 75 % RH) |
| Humidity Uniformity | ±0.3 % RH (at 25 °C / 60 % RH and 40 °C / 75 % RH) |
| Heating Rate | 0.17 °C/min |
| Internal Volume | 700 L |
| Chamber Dimensions (W×D×H) | 973 × 576 × 1250 mm |
| External Dimensions (W×D×H) | 1250 × 885 × 1925 mm |
| Power Supply | 200–230 V, 50/60 Hz, 1.2 kW |
| Noise Level | 48 dB(A) |
| Energy Consumption | 130 Wh/h (at 40 °C / 75 % RH) |
| Compliance | DIN 12880:2007, ICH Q1A |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Chamber Type | Upright |
| Model Families | KBF, KBF P, KBF LQC, KMF |
| Temperature Range (dry) | 0–70 °C |
| Temperature Range (humidified) | 10–70 °C |
| Humidity Range | 10–80 % RH |
| Brand | BINDER |
|---|---|
| Origin | Germany (Manufactured under BINDER quality standards |
| Model | KBF115 |
| Instrument Type | Upright Environmental Test Chamber |
| Temperature Range (with humidity control) | 10–90 °C |
| Humidity Range | 10–90 % RH |
| Temperature Uniformity (at 37 °C, with humidity) | ±1.0 °C |
| Temperature Fluctuation (heating mode) | ±0.1 °C |
| Humidity Fluctuation | ±1.5 % RH |
| Heating Rate to 37 °C | 23 min |
| Cooling Rate from RT to 10 °C | 35 min |
| Recovery Time (30 s door opening, back to 37 °C) | 5 min |
| Internal Volume | 115 L |
| Internal Dimensions (W×H×D) | 600×480×400 mm |
| Stainless Steel Shelves (standard) | 2 pcs (20 kg load per shelf) |
| Refrigerant | R134a |
| Safety Class | Independent temperature safety device Class 3.1 (DIN 12880) |
| Controller | MCS microprocessor-based controller with 25 programmable protocols (100 segments each, max. 500 total segments) |
| Interface | RS422 for APT-COM® data logging and remote monitoring |
| Humidity Sensor | Capacitive, maintenance-free |
| Humidification | Electrode-type, compatible with tap water (conductivity 200–500 µS/cm) |
| Defrost System | Automatic, designed for continuous long-term operation |
| Door | Single, double-glazed internal glass door with condensate collection tray |
| Inlet Port | 30 mm silicone-sealed access port (right side) |
| Power Supply | 230 V ±10 %, 50/60 Hz, 1.7 kW |
| Net Weight | 115 kg |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Manufacturer | BINDER GmbH |
| Type | Benchtop Environmental Test Chamber |
| Cooling Method | Water-cooled |
| Temperature Range | 0 °C to +70 °C |
| Humidity Range | 10 % RH to 80 % RH |
| Temperature Uniformity | ±0.1 K |
| Humidity Uniformity | ±1.5 % RH |
| Interior Dimensions (W×D×H) | 656 mm × 500 mm × 386 mm |
| Refrigerant | R-600a |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Manufacturer | BINDER GmbH |
| Type | Upright Environmental Test Chamber |
| Cooling Method | Water-Cooled |
| Temperature Range | 0 °C to +70 °C |
| Humidity Range | 10 % RH to 80 % RH |
| Temperature Uniformity | ±0.1 K |
| Humidity Uniformity | ±1.5 % RH |
| Interior Dimensions (W×D×H) | 656 mm × 695 mm × 575 mm |
| Energy Efficiency Improvement | 40 % vs. previous generation |
| Refrigerant | R-600a |
| Inner Chamber Material | Stainless Steel (AISI 304) |
| Control System | Touchscreen Controller with APT-COM™ Basic Software Integration |
| Compliance | ICH Q1, Q5C, DIN 12880 Class 3.3, ISO 17025-relevant environmental monitoring capability |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | LIT MK 240 |
| Temperature Range | −40 °C to +110 °C (extendable to +120 °C with dual safety cut-off) |
| Temperature Uniformity | ±0.1 K to ±1.2 K (dependent on setpoint) |
| Temperature Stability | ±0.1 K to ±0.5 K |
| Heating Rate (IEC 60068-3-5) | 5 K/min |
| Cooling Time (110 °C → −40 °C) | 160 min |
| Average Cooling Rate (IEC 60068-3-5) | 3.5 K/min |
| Thermal Compensation at 25 °C | 3000 W |
| Rated Voltage | 400 V or 480 V AC, 3~ |
| Frequency | 50/60 Hz |
| Nominal Power | 5.6 kW |
| Fuse Rating | 16 A |
| Internal Volume | 228 L |
| Net Weight (empty) | 375 kg |
| Max. Load Capacity | 70 kg |
| Shelf Load per Rack | 30 kg |
| Viewing Window | 508 mm × 300 mm (heated, LED-lit) |
| Internal Dimensions (W×H×D) | 735 mm × 700 mm × 443 mm |
| External Dimensions (W×H×D) | 1335 mm × 1929 mm × 925 mm |
| Rear Clearance | 300 mm |
| Side Clearance | 200 mm |
| Sound Pressure Level | 62 dB(A) |
| Safety Systems | Dual independent Class 2 temperature cut-offs (DIN 12880), CO/H₂/O₂/temperature gas monitoring, CO₂ fire suppression, reinforced door lock, reversible stainless-steel pressure relief valve, APT.line™ pre-heating chamber, condensation protection programming, fluorine-free refrigerant R-452A |
| Control Interface | Touchscreen controller with time-segment & real-time programming, APT-COM™ Basic software, Ethernet interface, USB data export (open CSV format), internal datalogger, 230 V socket on right-side panel |
| Standard Equipment | 1 stainless-steel shelf, compressed-air-cooled refrigeration unit |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | LIT MK 720 |
| Temperature Range | –40 °C to +110 °C |
| Temperature Uniformity (±K) | 0.1–0.5 |
| Temperature Stability (±K) | 0.3–2.0 |
| Avg. Heating Rate (IEC 60068-3-5) | 4 K/min |
| Avg. Cooling Rate (IEC 60068-3-5) | 3.4 K/min |
| Internal Volume | 734 L |
| Max. Load Capacity | 160 kg |
| Net Weight | 570 kg (LIT MK 720-400V) / 522 kg (LIT MK 720-480V-C) |
| Power Supply | 400 V, 3~ |
| Refrigerant | R-452A |
| Sound Pressure Level | 65–67 dB(A) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model Series | M, MK, MKT |
| Application Scope | Thermal Stress Testing, Stability & Durability Evaluation, Material Aging (per EN 60811-1-2 / IEC 60811-1-2) |
| Compliance | ISO 17025-accredited laboratory use, GLP/GMP-compatible operation, FDA 21 CFR Part 11-ready software options available |
| Cooling Method | Dual-circuit refrigeration with cascade system (for MKT series down to –70 °C) |
| Temperature Range | –70 °C to +180 °C (MKT), –40 °C to +180 °C (MK), –20 °C to +180 °C (M) |
| Uniformity | ±0.3 °C (at 100 °C, load-free) |
| Control System | BINDER CTC Advanced Touchscreen Controller with programmable ramp/soak profiles, real-time data logging, and Ethernet interface |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | MDL |
| External Dimensions (L×H×W) | 834×800×685 mm |
| Internal Dimensions (L×H×W) | 600×435×435 mm |
| Temperature Range | +5 °C above ambient to 350 °C |
| Internal Volume | 115 L |
| Temperature Uniformity | ≤ ±0.5 °C |
| Airflow Rate | 400 L/min |
| Heating Power | 9.0 kW |
| Safety Class | Dual independent temperature safety device (DIN 12880, Class 2) |
| Fresh Air Filter | EU6 (F6), particle retention ≥1 µm |
| Rear Exhaust Port | Ø100 mm |
| Shelves | 2 chrome-plated adjustable shelves |
| Controller | MCS microprocessor-based controller with 25 stored programs, 100 segments per program, up to 500 total segments |
| Display | User-friendly LCD with intuitive menu navigation |
| Data Logging | Built-in electronic chart recorder with multiple real-time graphical display options |
| Real-Time Clock | Integrated |
| Ramp Function | Programmable via on-board editor |
| Door Seal | High-temperature silicone gasket |