| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model Series | CAP |
| Instrument Type | Rotational Viscometer |
| Mounting Style | Benchtop (Fixed) |
| Operating Environment | High-Temperature Capable |
| Viscosity Range | 20 – 1,500,000 mPa·s |
| Temperature Range | 5–235 °C |
| Torque Options | High Torque (ICI Standard): 181,000 dyne·cm |
| Low Torque | 7,970 dyne·cm |
| Speed Range | 5–1000 rpm (995 programmable increments) |
| Sample Volume | < 1 mL |
| Temperature Control | Peltier-based (L-Series: 5–75 °C |
| H-Series | 50–235 °C) |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CETR-UMT |
| Instrument Type | Nanoindentation and Scratch Tester |
| Maximum Indentation Depth | 75 mm |
| Effective Load Range | 1 mN to 1000 N |
| Load Resolution | 1 µN |
| Displacement Range | ±75 mm |
| Displacement Resolution | 0.1 nm |
| Maximum Friction Force | 1000 N |
| Indenter Types | Conical, Berkovich, Spherical, Cube-Corner, Flat Punch, Custom Tips |
| Thermal Drift | <0.1 nm/min (at 25 °C, stabilized) |
| [Brand | Aerospace Zongheng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Model | CTN-1 |
| Application | Building Materials Flame Retardancy Testing |
| Measurement Object | Non-combustible/Flame-Retardant Building Materials |
| Repeatability Error | ±0.1% |
| Power Supply | AC 220/380 V, 50–60 Hz, ~0.5 kW |
| Airflow Velocity | (0.260 ± 0.026) m/s |
| Airflow Accuracy | ±0.1 m/s |
| Timer Accuracy | <1 s/h |
| Differential Pressure Range | 0–100 Pa |
| Fuel Gas | ≥95% Methane |
| Test Duration | 10 min |
| Combustion Chamber Material | AISI 304 Stainless Steel |
| Dimensions (L×W×H) | 3020 mm × 1020 mm × 3930 mm] |
| Brand | Betop Scientific |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Model | Delta-NIR |
| Price Range | USD 28,000 – 70,000 |
| Wavelength Range | 900–1700 nm |
| Thickness Measurement Range | 10 µm – 3 mm |
| Accuracy | ±10 nm |
| Precision | ±3 nm |
| Incidence Angle | 90° |
| Sample Compatibility | Transparent or Semi-Transparent Materials |
| Measurement Modes | Reflectance and Transmittance |
| Spot Size | 2 mm (standard), optional micro-spot accessory available |
| In-Line Capability | Yes |
| XY Scanning | Optional |
| Compliance | ASTM E1548, ISO 21287, GLP/GMP-ready data traceability per FDA 21 CFR Part 11 (via optional software module) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | Dial Viscometer |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 1–8,000,000 mPa·s |
| Torque Accuracy | ±1% of Full Scale |
| Repeatability | ±0.2% of Full Scale |
| Speed Control | Manual Stepwise (0.3–100 rpm, model-dependent) |
| Calibration Traceability | NIST-Traceable Standard Fluids |
| Power Supply | Universal AC Input (100–240 VAC, 50/60 Hz) |
| Warranty | 2-Year Limited |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DIN Adapter (DAA) |
| Compliance | DIN 53019, ASTM D2196 Equivalent |
| Sample Volume | 16–20 mL |
| Geometry | Cylindrical Couette |
| Shear Rate Calculability | Yes |
| Included Components | 3 rotors + 2 sample cups |
| Viscosity Range (LV/T series) | 1.9–50,000 mPa·s |
| Viscosity Range (RV/HA/HB series) | 10.0–50,000 mPa·s |
| Mounting Compatibility | All Brookfield standard laboratory viscometers and rheometers (DV1, DV2, DV3, RV, HA, HB series) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DIN |
| Compliance | DIN 53019 / ASTM D2196 Equivalent |
| Sample Volume | 16–20 mL |
| Geometry | Cylindrical Couette-type |
| Shear Rate Definition | Well-defined, geometry-determined |
| Viscosity Range (by spindle/viscometer combination) | 1.0–50,000 mPa·s (cP) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DV-II+ Pro |
| Pricing | Available Upon Request |
| Torque | 673.7 dyn·cm |
| Speed Range | 0.01–200 rpm (54 programmable speeds) |
| Spindles | 4 standard spindles included |
| Viscosity Range | 15–2,000,000 cP |
| Display | Digital LCD showing viscosity (cP), % torque, temperature (°C), rotational speed (rpm), and spindle identification |
| Control Interface | Microprocessor-based touchpad control with RS-232 interface for PC connectivity |
| Temperature Sensing | Compatible with RTD temperature probes (e.g., PT100) for real-time thermal monitoring |
| Data Acquisition | Supports DV-Gather™ software for multi-curve overlay (up to 5 simultaneous datasets), synchronized temperature logging, and time-stamped data export |
| Output | RS-232 port for connection to chart recorders or thermal printers for scheduled hard-copy reporting |
| Power Supply | AC 220 V, 50 Hz |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DV-II+Pro |
| Pricing | Available Upon Request |
| Spindle Compatibility | LV/RV/HA/HB |
| Speed Range | 0.01–200 rpm (54 programmable speeds) |
| Viscosity Range (LV) | 1–6,000,000 cP |
| Viscosity Range (RV) | 100–40,000,000 cP |
| Viscosity Range (HA) | 200–80,000,000 cP |
| Viscosity Range (HB) | 800–3,204,000,000 cP |
| Accuracy | ±1% of full-scale reading |
| Repeatability | ±0.2% |
| Integrated RTD Temperature Sensor | Yes |
| Data Output Interface | RS-232 |
| Software Compatibility | RHEOCALC-32 (included), WinTherm (optional), WinGather (optional) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Instrument Type | Rotational Viscometer |
| Model | DV-II+Pro EXTRA |
| Bearing System | Precision Ball-Bearing Suspension (excludes LV models) |
| Speed Range | 0.1–200 rpm (54 programmable speeds) |
| Viscosity Accuracy | ±1.0% of reading |
| Repeatability | ±0.2% |
| Displayed Parameters | Viscosity (cP or mPa·s), Temperature (°C or °F), Shear Rate/Shear Stress, % Torque, Rotational Speed, Rotor ID, Timed Stop Countdown |
| Included Accessories | EZ-Lock Quick-Connect Rotor System, Q-Drive Vertical Positioning Stand, Integrated Temperature Probe, RheoCalc Software, DV Loader Software, Standard Rotor Set (4 for LV |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | DV-n+PRO |
| Instrument Type | Rotational Viscometer (Not Oscillatory) |
| Speed Range | 0.1–250 rpm |
| Viscosity Range | 1–32,000,000 cP (depending on spindle & model variant) |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.5% |
| Temperature Control | Integrated RTD probe (0–200 °C, ±0.1 °C) |
| Spindle Options | Standard #1–#7 |
| Data Interface | RS-232/USB |
| Compliance | Calibratable to NIST-traceable standard oils |
| Brand | SUNNY HENGPING INSTRUMENT |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 10–3.2×10⁸ mPa·s (model-dependent) |
| Display | High-Resolution TFT Color Screen |
| Speed Control | Stepless & Stepped (0.1–200 rpm) |
| Rotor Compatibility | Spindles #1–#4 (DV-1/DV-2), R2–R7 (DV-3/DV-4) |
| Accuracy (Newtonian fluids) | ±1% |
| Dimensions (L×W×H) | 325×280×370 mm |
| Optional Accessories | UL Adapter (SP-0), Small Sample Adapter |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Brookfield NEW DV1 |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 0.3–100,000 mPa·s (cP) |
| Speed Range | 0.3–100 rpm (18 programmable speeds) |
| Accuracy | ±1% of full-scale reading |
| Repeatability | ±0.2% |
| Display | Backlit LCD with large-font parameter readout |
| Interface | USB port for Wingather SQ software and direct label printer connectivity |
| Temperature Monitoring | Optional RTD probe support |
| Compliance | Designed to support ASTM D2196, ISO 2555, ISO 3219, USP <911>, and GLP/GMP data integrity requirements |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DV1 |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 1–2,000,000 mPa·s |
| Accuracy | ±1.0% of full-scale reading |
| Repeatability | ±0.2% |
| Speed Control | 18 programmable RPM settings (0.3–100 rpm) |
| Display | Large-font, multi-parameter digital LCD |
| Languages | English, Chinese, French, German, Spanish, Portuguese, Russian |
| Interface | USB (compatible with optional Wingather SQ software) |
| Temperature Measurement | Optional RTD probe (DVP-94Y, requires specification at time of order) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | DV2Plus |
| Instrument Type | Rotational Viscometer |
| Mounting Style | Benchtop (Fixed) |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 1–320 × 10⁶ mPa·s |
| Temperature Range | 0–300 °C |
| Compliance | ISO/IEC 17025 Calibration Available, NIST-Traceable Standards, FDA 21 CFR Part 11 Readiness (via optional software module) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DV2Plus |
| Viscosity Range (cP) | LV: 1–6M |
| RV | 100–40M |
| HA | 200–80M |
| HB | 800–320M |
| Speed Range | 0.1–200 rpm (740 programmable steps) |
| Accuracy | ±1.0% |
| Repeatability | ±0.2% |
| Display | 7″ color PCAP touchscreen (800 × 480 resolution) |
| Compliance | Optional 21 CFR Part 11 via DV360™ software |
| Connectivity | Bluetooth, USB-A, USB-B |
| Included Spindles | 4× LV, 6× RV/HA/HB (model-dependent) |
| Built-in Features | Gel time measurement, oscillatory test mode, digital leveling, viscosity test wizard, step-programmable method execution |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | DV2T |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 1 – 320 × 10⁶ mPa·s |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DV2T |
| Instrument Type | Portable Rotational Viscometer |
| Viscosity Range | 1–6,000,000 cP (mPa·s) |
| Temperature Accuracy | ±1.0% of full-scale reading |
| Speed Control | 200 programmable RPM settings (0.1–200 rpm) |
| Display | 5-inch full-color touchscreen |
| Compliance | ASTM D2196, ISO 2555, USP <911>, GLP/GMP-ready data logging |
| Interface | USB PC connectivity with optional PG Flash and Rheocalc T software support |
| Standard Spindles | LV (4), RV/HA/HB (6) depending on configuration |
| Operating Environment | Ambient temperature |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DV2T |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 1 to 320 × 10⁶ mPa·s (cP) |
| Speed Control | 0.01–200 rpm (200 programmable increments) |
| Accuracy | ±1.0% of full-scale reading |
| Repeatability | ±0.2% |
| Temperature Measurement | Integrated RTD probe (±0.1 °C typical) |
| Display | 5-inch full-color touchscreen |
| Compliance | FDA 21 CFR Part 11 (electronic signatures, user access levels, audit trail) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DV2T Gel Time Tester |
| Type | Rotational Viscometer with Gel Time Measurement Capability |
| Compliance | ASTM D2471, ISO 3219, USP <911> (Gelation Time) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | DV2T Gel Timer |
| Price | Upon Request |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 1–320 mPa·s (cP) |
| Display | 5-inch Full-Color TFT Touchscreen |
| Compliance | FDA 21 CFR Part 11 Ready |
| Accuracy | ±1.0% of full-scale reading |
| Repeatability | ±0.2% |
| Temperature Probe | Integrated RTD sensor (±0.1 °C) |
| Data Interface | USB-B to PC |
| Standard Accessories | LV-1 spindle, leveling bubble vial, PG Flash software |
| Optional Software | RheoCalcT (included with DV2T EXTRA configuration) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DV2TLV |
| Viscosity Range | 1–200 mPa·s |
| Instrument Type | Benchtop (Not Online) |
| Operating Environment | Ambient Temperature |
| Software | RheoCalc T v3.x |
| Compliance | FDA 21 CFR Part 11 (Electronic Signatures, User Access Control, Audit Trail) |
| Data Storage | Password-Protected Local Database |
| Test Modes | Single-Point, Ramp, Hold, Cycle |
| Mathematical Models | Bingham, Casson, Power Law, Herschel-Bulkley |
| Multi-Sample Comparison | Up to 5 Data Sets |
| Temperature Control | Not Integrated (Requires External Bath or Peltier Accessory) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DV3T |
| Pricing | Upon Request |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DV3T |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 1–1.6 × 10⁶ mPa·s (cP) |
| Display | 7-inch full-color touchscreen (multi-language support) |
| Temperature Probe | Built-in RTD sensor |
| Accuracy | ±1.0% of reading |
| Repeatability | ±0.2% |
| Connectivity | USB PC interface (included), optional PC control & automated data acquisition via PG Flash software |
| Compliance | Supports GLP/GMP documentation workflows, audit trail-ready for FDA 21 CFR Part 11–aligned environments (when used with validated software configuration) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DVNext |
| Instrument Type | Rotational Rheometer |
| Sample State | Liquid |
| Bearing Type | Mechanical Bearing |
| Minimum Speed | 0.01 rpm |
| Maximum Speed | 250 rpm |
| Sample Volume | 0.5–2.0 mL |
| Shear Rate Range | Up to 1875 s⁻¹ (with CP-52Z) |
| Torque Accuracy | ±1.0% of Full Scale |
| Repeatability | ±0.2% |
| Temperature Range | 0–100 °C |
| Geometry | Cone-and-plate |
| Control Interface | Integrated Touchscreen Display |
| Auto-Zero Function | Yes |
| Auto-Range Torque Measurement | Yes |
| Wetted Materials | 316 Stainless Steel |
| Optional Accessories | Luer fittings, embedded Pt100 temperature probe, cleaning adapters |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | DVNext |
| Instrument Type | Rotational Viscometer/Rheometer |
| Viscosity Range | 1–320M mPa·s |
| Display | 7-inch Full-Color Touchscreen |
| Compliance | 21 CFR Part 11, GAMP 5 |
| Temperature Accuracy | ±1% of full scale (with PT-100 probe) |
| Internal Storage | 150 MB |
| Connectivity | USB, LIMS-ready, optional Ethernet/Wi-Fi |
| Control Mode | Standalone or PC-controlled (RheocalcT software) |
| Spindle Coupling | Magnetic coupling system |
| Leveling | Digital auto-leveling |
| Test Modes | Single-step & multi-step programmable protocols |
| Yield Stress & Flow Curve Analysis | Built-in Casson, Bingham, Power Law, Thix Index models |
| Temperature Integration | Compatible with AP/SD series circulators and high-temperature systems |
| Accessories Support | Cone/plate geometry, UL adapter, small-volume adapter, gel time coupler, DIN/ISO adapters, spiral, T-bar, paddle rotors, roller bearing spindles (HA/HB), RV/HA/HB-1 spindles |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DVNext |
| Instrument Type | Rotational Viscometer/Rheometer |
| Mounting | Benchtop (Fixed) |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 1–320 million cP (mPa·s) |
| Temperature Control | External (via AP/SD Series Circulators or High-Temp Systems) |
| Temperature Accuracy | ±1 °C |
| Temperature Resolution | 1 °C |
| Speed Range | 0.01–250 RPM (2,600 programmable increments) |
| Compliance | FDA 21 CFR Part 11 (Regulatory-Ready Firmware & Audit Trail) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DVNext |
| Viscosity Range (LV) | 0.01–250 cP (mPa·s) |
| Viscosity Range (RV/HA/HB with Optional Spindles) | up to 320M cP |
| Speed Control | 2600 programmable RPM increments (0.01–250 RPM) |
| Display | 7-inch full-color touchscreen |
| Temperature Accuracy | ±1% of full scale (with PT-100 probe) |
| Data Storage | 150 MB internal |
| Compliance | 21 CFR Part 11, GAMP 5 |
| Connectivity | USB, optional LIMS integration |
| Accessories Supported | UL Adapter (1 cP min), Cone & Plate systems, AP/SD temperature baths, RheocalcT software, barcode scanner, gel timer module, DIN adapters, T-spindles, spiral adaptors, small sample adapters |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Pricing | Available Upon Request |
| Spindle Set | #1, #2, #3, #4 |
| Rotational Speeds | 6, 12, 30, 60 rpm |
| Viscosity Range | 10–1×10⁵ mPa·s |
| Accuracy | ±5% of full scale |
| Power Supply | 220 V AC, 50 Hz |