| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | MK Series |
| Temperature Range | –40 °C to +180 °C |
| Internal Volume | 56–1020 L |
| Temperature Uniformity | ±0.1 K to ±2.0 K (depends on setpoint) |
| Temperature Stability | ±0.1 K to ±0.5 K (depends on setpoint) |
| Heating Rate (IEC 60068-3-5) | up to 5.5 K/min |
| Cooling Rate (IEC 60068-3-5) | up to 4.5 K/min |
| Refrigerant | R-452A (non-ozone-depleting) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Manufacturer | BINDER GmbH |
| Type | Imported Industrial Environmental Test Chamber |
| Model | MK 56 |
| Temperature Range | −40 °C to +180 °C |
| Cooling Method | Compressor-Based Refrigeration |
| Explosion-Proof | Standard (Non-Explosion-Proof) |
| Temperature Fluctuation | ±0.1 °C to ±0.5 °C |
| Temperature Uniformity | ±0.5 °C to ±1.5 °C |
| Average Heating Rate (per IEC 60068-3-5) | 5.0 °C/min |
| Average Cooling Rate (per IEC 60068-3-5) | 5.0 °C/min |
| Internal Chamber Dimensions | 720 mm × 778 mm × 1445 mm |
| Controller Interface | Touchscreen with APT Line™ Preheating Cavity Technology |
| Data Logging | Internal Recorder with USB Export |
| Viewing Window | Heated, LED-Illuminated Safety Glass |
| Condensation Protection | Programmable Interval & Real-Time Control |
| Alarm System | Optical and Acoustic Fault Diagnostics |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Manufacturer | BINDER GmbH |
| Type | MKF 115 |
| Temperature Range | -40 °C to +180 °C |
| Temperature Fluctuation | ±0.1–0.5 °C |
| Temperature Uniformity | ±0.1–2.0 °C |
| Heating Rate | 5.3 °C/min |
| Cooling Rate | 90 min (from +180 °C to -40 °C) |
| Interior Dimensions (W×H×D) | 980 × 1725 × 865 mm |
| Humidity Range | 10–98 %RH |
| Refrigerant | R-452A (non-ozone-depleting) |
| Chamber Construction | Stainless steel interior |
| Preheating Chamber Technology | APT.line™ |
| Controller | Intuitive touchscreen with interval & real-time programming |
| Data Logging | Internal recorder, USB export (open-format CSV), Ethernet interface |
| Safety | Dual-stage temperature safety device (DIN 12880 Class II), optical alarm |
| Accessories | Heated LED-illuminated observation window, 50 mm access port with silicone plug, 4 casters (2 braked), stainless steel shelf, integrated 20 L water reservoir |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | MKF Series |
| Temperature Range | −70 °C to +180 °C (−94 °F to +356 °F) |
| Humidity Range | 10–90 % RH (MKF 240 only) |
| Internal Volume | 228–734 L |
| Temperature Uniformity | ±0.1–±1.0 K |
| Temperature Stability | ±0.1–±0.5 K |
| Heating Rate (−40 °C → 180 °C) | 1.1–5.5 min |
| Cooling Rate (180 °C → −40 °C) | 0.6–5.2 min |
| Refrigerant | R404a |
| Compliance | DIN EN 60068-3-5, IEC 60068-3-6, GLP/GMP, FDA 21 CFR Part 11 (via APT-COM) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model Series | MKF / MK / MKT |
| Internal Volume Options | 53 L, 115 L, 240 L, 400 L, 720 L |
| Temperature Range | MK/MKF: −40 °C to +180 °C |
| MKT | −70 °C to +180 °C |
| M-Series | +5 °C above ambient to +300 °C |
| Humidity Range (MKF only) | 10–98 % rH |
| Control System | MB1 4-channel touchscreen controller (25 programs × 100 segments) |
| Cooling Technology | DCT® Direct Cooling Technology |
| Preconditioning Chamber | APT-Line® |
| Air Circulation | Digitally adjustable high-power turbine |
| Compliance | DIN EN 60068-3-5, IEC 60068-3-6, ISO 16750-4, ASTM D4329, USP <1151> (environmental stress testing), GLP-compliant data logging via APT-COM software |
| Interface | RS422 for APT-COM v3.x integration |
| Insulation | High-efficiency vacuum-insulated door & polyurethane foam walls |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | MKF115, MK115, MKT115 |
| Temperature Range | -70 °C to +180 °C |
| Thermal Shock Range | -70 °C to +180 °C |
| Temperature Stability | ±0.1 °C to ±0.6 °C |
| Heating Rate | 5.3 °C/min |
| Cooling Rate | 4.2 °C/min |
| Humidity Control (MKF/MKFT only) | 10–98 % RH |
| Integrated Water Reservoir | 20 L |
| Programmable Condensation Protection | Yes |
| APT.line™ Preheating Technology | Standard |
| MCS Controller with 4 Zero-Voltage Switch Outputs | Standard |
| Heated & LED-Illuminated Viewing Window | Standard |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Manufacturer | BINDER GmbH |
| Model | MKFT 720 |
| Temperature Range | −70 to +180 °C |
| Humidity Range | 10–98 %RH |
| Refrigeration System | Dual-stage compression refrigeration |
| Temperature Uniformity | ±0.1 to ±0.5 °C (at setpoint, steady state) |
| Temperature Deviation | ±0.3 to ±2.0 °C (across working chamber) |
| Heating Rate | up to 4.8 °C/min (typical, empty chamber) |
| Cooling Rate | 180 → −70 °C in ≤120 min (empty chamber) |
| Integrated Water Reservoir | 20 L |
| Control Interface | APT Line™ touchscreen controller with interval & real-time programming |
| Data Logging | Internal recorder with USB export capability |
| Viewing Window | Heated, double-glazed, LED-illuminated |
| Preconditioning Technology | APT Line™ preheating chamber |
| Alarm System | Optical and acoustic fault diagnostics |
| Safety Certification | Complies with IEC 61010-1, EN 60529 (IPX1), CE-marked for EU use |
| Explosion Protection | Standard (non-explosion-proof) configuration |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | MKFT |
| Temperature Range | –70 °C to +180 °C |
| Humidity Range | 10–98 % RH |
| Temperature Uniformity | ±0.1–2.0 K (depending on setpoint and chamber size) |
| Temperature Fluctuation | ±0.1–0.5 K |
| Humidity Fluctuation | ≤±2.5 % RH |
| Heating Rate (IEC 60068-3-5) | up to 5.5 K/min |
| Cooling Rate (IEC 60068-3-5) | up to 4.2 K/min |
| Internal Volumes | 115 L / 228 L / 734 L |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | MKFT115 / MKFT240 / MKFT720 |
| Temperature Range | –70 °C to +180 °C |
| Humidity Range | 10 % RH to 98 % RH |
| Internal Volume | 115 L / 228 L / 734 L |
| Refrigerant | R-452A |
| Humidity Control | Capacitive Sensor + Steam Humidification |
| Controller | MCS Touchscreen with Real-Time & Segment Programming |
| Data Logging | Integrated Internal Recorder + USB Export |
| Compliance | DIN 12880, IEC 60068-3-5, IEC 60068-3-6, MIL-STD-810G (climate profiles), GLP/GMP-ready audit trail support via optional software |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | MKT |
| Temperature Range | -70 °C to +180 °C |
| Compliance | DIN 12880 Class 2 Temperature Safety Device, IEC 60068, MIL-STD-810 |
| Humidity Control | Capacitive Hygrometer + Steam Humidification (MKT models) |
| Refrigerant | R-452A |
| Controller | MCS Touchscreen with Real-Time Clock, Ramp Function, Internal Data Logger |
| Interface | Ethernet, USB, 230 V Socket on Right Side |
| Safety | Optical & Acoustic Fault Diagnostics, Heated Viewing Window with LED Lighting, Silicone-Sealed Access Ports (50 mm for MKT 115/240 |
| Castors | 4, 2 with Brakes |
| Internal Volume | 115 L / 228 L / 734 L (MKT 115 / MKT 240 / MKT 720) |
| Net Weight | 305 kg / 380 kg / 610 kg |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Manufacturer | BINDER GmbH |
| Product Type | Imported Environmental Test Chamber |
| Model | MKT 240 |
| Temperature Range | −70 °C to +180 °C |
| Refrigeration Method | Dual-stage compression refrigeration |
| Explosion-Proof Design | Standard (non-explosion-proof) |
| Temperature Stability | ±0.1–0.4 °C (dependent on setpoint) |
| Temperature Uniformity | ±0.1–1.0 °C (dependent on setpoint) |
| Heating Rate (IEC 60068-3-5) | 5.0 °C/min (average) |
| Cooling Rate (IEC 60068-3-5) | 4.2 °C/min (average) |
| Internal Chamber Dimensions | 1115 mm × 925 mm × 1935 mm (W × D × H) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | WIC 1 |
| Configuration | Upright Walk-In Chamber |
| Temperature Range | 10–50 °C |
| Humidity Range | 20–93 %RH |
| Temperature Uniformity | ≤ ±0.5 °C |
| Temperature Stability | ≤ ±0.5 °C |
| Humidity Uniformity | ≤ ±2.5 %RH |
| Humidity Stability | ≤ ±2.5 %RH |
| Heating Rate | 1–3 °C/min |
| Interior Volume | 16–30 m³ |
| Insulation U-Value | 0.21 W/(m²·K) |
| Construction | Fully Stainless Steel Interior |
| Lighting | Sensor-Activated LED System |
| Refrigerant | Environmentally Compliant (R-513A or Equivalent) |
| Compliance | ICH Guidelines (Q1, Q5), ISO 14644-1 Class 8, USP <1151>, FDA 21 CFR Part 11 Ready (with optional software package) |
| Brand | Binsfeld |
|---|---|
| Origin | USA |
| Model | TT10K |
| Transmitter Dimensions | 25 mm × 41 mm × 64 mm |
| Transmitter Weight | 85 g |
| Operating Temperature | −30 °C to +85 °C |
| Battery Life | 24 h (9 V Li battery, 350 Ω bridge, 25 °C) |
| Excitation Voltage | 2.5 VDC ±0.1% |
| Supply Voltage (Transmitter) | 7.5–18 VDC |
| Transmit Current (Active) | 40 mA typical, 50 mA max |
| Transmit Current (Standby) | 4 mA typical, 5 mA max |
| Gain Range | 500–16,000 (6 selectable steps) |
| Frequency Response | 0–500 Hz (−3 dB at 500 Hz), adjustable low-pass filtering |
| Output Delay | 4.2 ms typical (500 Hz filter setting) |
| Sampling Rate | 2400 samples/sec |
| ADC Resolution | 14-bit |
| Output Options | ±10 VDC analog (field-adjustable gain 0.25× to 4.0×), RS-232 serial (DB9) |
| Transmission Band | 902–925 MHz |
| Line-of-Sight Range | ≥6 m (20 ft) |
| Centrifugal Tolerance | 3000 g (e.g., 5700 RPM on 102 mm shaft) |
| Strain Gauge Compatibility | Full-bridge, 350 Ω standard (1000 Ω optional) |
| Bridge Excitation | 2.5 VDC |
| Bias Error | ±0.25% of reading or ±0.16% FS (at gain = 4000, 25 °C) |
| Remote Control | IR-based, up to 3 m line-of-sight, enables channel selection, gain/FS adjustment, shunt calibration, and standby activation without disassembly |
| Brand | Binsfeld |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TPM2 |
| Pricing | Upon Request |
| Brand | Binsfeld |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TT |
| Pricing | Upon Request |
| Brand | Binsfeld |
|---|---|
| Country of Origin | USA |
| Model | TT-10K |
| Max Torque Capacity | 10,000 N·m |
| Torque Measurement Range | 0–10,000 N·m |
| Torque Resolution | 1% of full scale |
| Torsional Angle Range | 0–360° |
| Motor Power Rating | 1 kW |
| Operating Temperature | −30 °C to +85 °C |
| RF Frequency Band | 902–925 MHz (16 programmable channels) |
| Transmission Distance | Up to 6 m (20 ft) |
| Sampling Bandwidth | DC to 500 Hz (−3 dB) |
| ADC Resolution | 14-bit |
| Transmitter Power Supply | 7.5–18 VDC, max 50 mA @ 350 Ω bridge |
| Battery Life | 24 h (9 V Li battery, 25 °C, 350 Ω bridge) |
| Centrifugal Acceleration Tolerance | 3000 g |
| Output Options | ±10 VDC analog (field-adjustable), RS-232 digital |
| Remote Control Range | 3 m (10 ft) |
| Brand | Binsfeld |
|---|---|
| Origin | USA |
| Model | TT-R |
| Sensor Input | Full-bridge strain gauge (350 Ω, optional other resistances), 4 VDC excitation |
| Strain Range | ±500 με (full-bridge, 4-arm, torsion or bending) |
| Resolution | 14-bit |
| Frequency Response | DC to 1000 Hz (–3 dB) |
| Operating Environment | –40 °C to +85 °C, 0–90% RH (non-condensing) |
| Power Supply | 11–16 VDC, nominal 0.5 A, max 2 A (AC option available) |
| Output Signals | Four isolated 4–20 mA analog outputs (torque, speed, power, direction) |
| Telemetry Architecture | Non-contact inductive power coupling and digital RF data transmission |
| Mechanical Configuration | Rotating torque ring (integrated transmitter) + stationary power ring & master control unit |
| Size Series | Outer diameters increment in 2-inch steps for scalable shaft diameter coverage |
| Brand | Binsfeld |
|---|---|
| Origin | USA |
| Model | TT10K-LP |
| Operating Frequency | 903–925 MHz |
| Transmitter Dimensions | 17 mm × 26 mm × 51 mm |
| Transmitter Weight | 31 g |
| Battery Life (Active Mode) | 48 h (9 V Li battery, 350 Ω bridge, 25 °C) |
| Standby Current | 0.5 mA typical |
| Excitation Voltage | 3 VDC ±0.1% (bridge), 6–25 VDC (transmitter input) |
| Gain Range | 500–16,000 (6 selectable steps) |
| Bandwidth | 0–500 Hz (−3 dB at 500 Hz), programmable filtering |
| Output | ±10 VDC analog + RS-232 digital (DB9) |
| IP Rating | IP67 (transmitter with optional housing) |
| Operating Temperature | −30 to +85 °C |
| Resolution | 14-bit ADC |
| Bias Error | ±0.25% of reading (gain = 4000, 25 °C) |
| Signal Delay | 4.2 ms typical (500 Hz filter) |
| Sampling Rate | 2400 samples/sec |
| Strain Gauge Compatibility | Full-bridge, 350 Ω standard (1000 Ω supported) |
| Remote Control | IR-based, up to 3 m range, enables gain adjustment, shunt calibration, channel selection, and standby mode activation |
| Channel Capacity | 16 simultaneous systems |
| Centrifugal Acceleration Tolerance | 2000 g (steady-state) |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Flex |
| Instrument Type | Benchtop Video-Based Optical Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Sample Stage Dimensions | 105 mm × 105 mm |
| Image Magnification | Configurable Lens Options |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.1 mN/m (high range), ±0.01 mN/m (low range) |
| Camera Resolution | 1984 × 1264 pixels |
| Max Frame Rate | 3009 fps |
| Light Source | High-Power Monochromatic LED |
| Software | OneAttension v5.x |
| Compliance | Fully compatible with GLP/GMP workflows |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Attension Theta Flow |
| Instrument Type | Benchtop Video-Based Optical Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.01° |
| Sample Stage Dimensions | Unlimited × 100 × 320 mm (L×W×H) |
| Image Magnification | Selectable Options |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.1 mN/m, ±0.01 mN/m |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Sigma 700 |
| Measurement Range | 1–2000 mN/m |
| Resolution | 0.0001 mN/m (static), 0.001 mN/m (dynamic) |
| Accuracy | ±0.01 mN/m |
| Temperature Control Range | −20 to +200 °C |
| Temperature Accuracy | ±0.01 °C |
| Measurement Methods | Du Noüy Ring, Wilhelmy Plate, Dynamic Contact Angle, CMC, Surface Free Energy, Washburn Penetration, Adhesion Force, Sedimentation, Density |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Sigma 701 |
| Measurement Range | 1–2000 mN/m |
| Resolution (Surface Tension) | 0.001 mN/m |
| Accuracy (Surface Tension) | ±0.01 mN/m |
| Temperature Control Range | −20 to +200 °C |
| Temperature Resolution | 0.01 °C |
| Measurement Methods | Du Noüy Ring Method, Wilhelmy Plate Method |
| Density Range | 0–2.2 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Force Resolution | 0.05–0.1 µN |
| Contact Angle Range | 0–180° |
| Contact Angle Resolution | 0.01° |
| Motorized Stage Speed | 0.01–500 mm/min |
| Stage Positioning Accuracy | 0.016 µm |
| Dimensions (W×D×H) | 33.3 × 24.4 × 62 cm |
| Weight | 13–16 kg |
| Power Supply | 85–264 VAC, 47–440 Hz, 13 W |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Sigma 702ET |
| Measurement Range | 1–1000 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.01 mN/m |
| Temperature Control Range | −20 to +200 °C |
| Temperature Resolution | 0.01 °C |
| Measurement Methods | Du Noüy Ring Method & Wilhelmy Plate Method |
| Compliance | ASTM D971, IEC 62961 |
| Density Measurement Range | 0–2.2 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Force Resolution | 0.1 µN |
| Sample Stage Speed | 0.01–500 mm/min |
| Positional Accuracy | ±0.26 µm |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Sigma 703D |
| Measurement Range | 1–1000 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.01 mN/m |
| Temperature Display Range | −20 to +200 °C |
| Temperature Display Accuracy | ±0.01 °C |
| Measurement Methods | Du Noüy Ring Method, Wilhelmy Plate Method |
| Density Range | 0–2.2 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Force Resolution | 0.1 µN |
| Weight | 11 kg |
| Dimensions (W×D×H) | 33.3 × 24.4 × 62 cm |
| Power Supply | 85–264 VAC, 47–440 Hz, 13 W |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Flex |
| Instrument Type | Video-Based Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Resolution | 0.01° |
| Contact Angle Accuracy | ±0.01° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Sample Stage Dimensions | 100 mm × 320 mm |
| Maximum Sample Size (L×W×H) | 763 × 230 × 435 mm |
| Stage Load Capacity | 26 kg |
| Imaging System | USB 3.0 Digital Camera with 8× Zoom, High-Intensity Monochromatic LED Illumination |
| Image Resolution | 1936 × 1216 (optional Theta Flow high-speed camera available) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Flow with 3D Topography Module |
| Instrument Type | Benchtop Video-Based Optical Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.01° |
| Contact Angle Resolution | 2592 × 2048 (5.3 MP) |
| Surface Tension Range | 0.01–2000 mN/m |
| Surface Tension Accuracy | ±0.01 mN/m |
| Sample Stage Dimensions | Unlimited (L) × 100 mm (W) × 320 mm (D) |
| Max Sample Size | Unlimited (L) × 320 mm (W) × 22 mm (H) |
| Imaging Sensor | 5.3 MP CMOS, 2592 × 2048 pixels |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Flow HPC High Pressure Chamber |
| Instrument Type | Benchtop Laboratory System |
| Contact Angle Range | 0.1–179.9° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 2592 × 2048 (5.3 MP) |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Sample Stage Dimensions | Unlimited × 100 mm × 320 mm |
| Maximum Sample Size | 765 mm × 230 mm × 435 mm |
| Stage Load Capacity | 29 kg |
| Imaging Sensor | 5.3 MP CMOS, 2592 × 2048 pixels |
| Pressure Control | Automated via integrated precision pump |
| Temperature Range | Ambient to elevated temperatures (optional sub-ambient cooling available) |
| Chamber Design | Piston-driven high-pressure cell with corrosion-resistant wetted materials (e.g., Hastelloy C-276, sapphire windows) |
| Fluid Handling | Dual-path intelligent injection valve for direct syringe-based dispensing and in-line cleaning without pump priming |
| Surface Activity Preservation | Piston displacement maintains constant bulk-phase surfactant concentration during pressure ramping |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Flow |
| Instrument Type | Benchtop Dynamic Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Contact Angle Accuracy | ±0.01° |
| Contact Angle Resolution | 2592 × 2048 (5.3 MP) |
| Imaging System | USB 3.0 Digital Camera with 8× Optical Zoom & High-Power Monochromatic LED Illumination |
| Sample Stage Dimensions | 765 mm × 230 mm × 435 mm (W × D × H) |
| Maximum Sample Weight | 29 kg |
| Environmental Monitoring | Integrated Temperature & Humidity Sensors |
| Software Platform | OneAttension v4.x with Audit Trail, CFR 21 Part 11 Compliance Options |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Flow Wafer |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | Contact angle, surface tension, interfacial tension, surface free energy |
| Contact Angle Accuracy | ±0.1° |
| Sample Stage Sizes | 2", 3", 4", 5", 6", 8", 12" wafers |
| Image Resolution | 2592 × 2048 (5.3 MP) |
| Surface/Interfacial Tension Accuracy | ±0.1 mN/m (derived via pendant/sessile drop analysis) |
| Maximum Sample Diameter | 12-inch silicon wafer |
| Stage Load Capacity | 500 g |
| Automated Functions | Motorized XYZ translation + programmable rotation (0–360°), four independent software-controlled dispensers with disposable tips |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Lite |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Resolution | 0.01° |
| Contact Angle Accuracy | ±0.1° (standard), ±0.01° (high-precision mode) |
| Surface & Interfacial Tension Range | 0.01–2000 mN/m |
| Surface & Interfacial Tension Accuracy | ±0.1 mN/m (standard), ±0.01 mN/m (high-precision mode) |
| Camera Resolution | 1936 × 1216 pixels |
| Sample Stage Dimensions (L×W×H) | 495 × 130 × 310 mm |
| Max. Sample Weight Capacity | 5 kg |
| Image Magnification | Fixed optical path with high-magnification telecentric lens system |
| Measurement Modes | Static CA, Advancing/Receding CA, Roll-off Angle, Surface Free Energy (Owens-Wendt, Wu, van Oss), Interfacial Tension, Batch Analysis, Roughness-Corrected CA, Single-Fiber CA |
| Software | OneAttension v4.x (FDA 21 CFR Part 11 compliant audit trail option available) |